• Title/Summary/Keyword: Measurement Quality

Search Result 4,470, Processing Time 0.033 seconds

A Statistical Software for Measurement Systems Analysis (측정시스템 분석용 통계소프트웨어의 개발)

  • 이승훈;이종환
    • Journal of Korean Society for Quality Management
    • /
    • v.28 no.1
    • /
    • pp.175-195
    • /
    • 2000
  • In this study, we developed a statistical software for measurement systems analysis. This software is patterned after the Measurement Systems Analysis Reference Manual developed by the Automotive Industry Action Group (AIAG). This software includes stability analysis, bias and linearity analysis, and gage R&R studies. This software was developed by using Delphi(version 4.0) and can be implemented on MS Windows 95 or higher level.

  • PDF

A Technique and software of analysis and control for measurement process

  • Zhao, Fengyu;Xu, Jichao;Bergman, Bo
    • International Journal of Quality Innovation
    • /
    • v.1 no.1
    • /
    • pp.97-105
    • /
    • 2000
  • In this paper, a two-section method for measuring is introduced and the variation sources of measurement process are analysed. Measuring is a special process in general process. Various variation source must be firstly decomposed so that the statistical distribution law of measuring process can be established, and then implement monitoring control of the measuring process. A special method to obtain the measuring variation is discussed, and a monitoring control technique for measuring process is studied based statistical distribution. Towards the end, we briefly introduce software design for the analysis and control of a measurement process.

  • PDF

Empirical Comparison of Measurement Methods for Educational Service Quality

  • Kang, Sung;Choi, Kyung-Ho
    • Journal of the Korean Data and Information Science Society
    • /
    • v.19 no.3
    • /
    • pp.801-809
    • /
    • 2008
  • Nowadays almost all universities are endeavoring to improve the quality of education offered. The quality of education that is provided should be measured beforehand. This study examined three methods, SERVQUAL, SERVPERF and Lee and Yun(2004)'s method of measuring service quality: SERVQUAL, SERVPERF are well known and the most commonly used measurement of the quality of education offered and the Lee and Yun(2004)'s method measures service quality using fuzzy numbers. As a result of this research, SERVQUAL was proven to be the most efficient method to measure the quality of education offered. Even though, more actual analysis related to this study should be followed, the research is meaningful in a way that it provided clues and reasons for the study.

  • PDF

Measurement of Cortisol in Human Serum by Isotope Dilution Liquid Chromatography/Mass Spectrometry and a Comparison through a Proficiency Testing

  • Lee, Hwa-Shim;Shin, Hye-Sun;Park, Sang-Ryoul;Park, Chang-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.5
    • /
    • pp.1149-1154
    • /
    • 2010
  • Liquid chromatography/mass spectrometry using isotope dilution method has been established as a primary method for the measurement of cortisol in human serum. Verification of this method was accomplished by the participation in Consultative Committee for Amount of Substance-Metrology in Chemistry (CCQM) pilot study. Two levels of cortisol certified reference materials were prepared and certified by the established method. They were used as sample materials for the proficiency testing. The expanded uncertainty in the measurement of cortisol in human serum was approximately 1.2% at 95% confidence level. The results of the proficiency testing showed a good precision among the participants, but some bias to the certified values. This means that commercial field laboratories should keep traceability chain to SI unit through available reference measurement procedures and/or available reference materials.

Time Synchronization of the Monitoring Data for the VoIP User Assessment of Voice Quality Measurement (인터넷전화 이용자 체감품질 측정을 위한 측정데이터 간의 시간동기화)

  • Kweon Tae-Hoon;Hwang Hyae-Jeong;Lee Seog-Ki;Song Han-Chun;Won Seung-Young
    • The Journal of the Korea Contents Association
    • /
    • v.5 no.4
    • /
    • pp.227-236
    • /
    • 2005
  • We study, in terms of VoIP user assessment of voice quality, the synchronization of measurement system is important. Commonly the synchronization system uses NTP(Network Time Protocol) or GPS(Global Positioning System), these synchronization method has time error of distance, system overhead of data processing, and system specialized clock error. we propose and implement the synchronization method to correct time error between two measurement system in the internet. So the time synchronization of systems can get time error, then user assessment of voice quality become reliable.

  • PDF

Development of the Nursing Process Based Performance Measurement Tool for Medication Management and Blood Transfusion (투약과 수혈간호의 간호과정 적용 평가도구 개발)

  • Kim, Keum Soon;Kim, Jin A;Kwon, So Hi;Song, Mal Soon
    • Journal of Korean Clinical Nursing Research
    • /
    • v.16 no.1
    • /
    • pp.177-196
    • /
    • 2010
  • Purpose: This study was conducted to develop the nursing process based performance measurement tool and the evidence based care standards for nursing care in medication management and blood transfusion. Methods: The care standards and performance measurement tool were drafted through comprehensive review of relevant literature, national guidelines, hospital protocols, and standards of recognized international accrediting bodies. The proposed care standards and performance measurement tool were reviewed by the panel of experts and refined based on the panel's suggestions. Final care standards and performance measurement tool were validated by surveying the hospital nurses. Results: All items of the performance measurement tool for medication management and blood transfusion were evaluated appropriate. All contents of care standards and the measurable elements except the evaluation of discharge education were appropriate. The performance measurement tool developed in this study was found to be acceptable as a tool to evaluate quality of nursing care in medication management and blood transfusion. Conclusion: The outcomes of this study including the performance measurement tool and evidence based care standards would be the important indicators to monitor whether necessary nursing care is implemented and be the useful primary resources to improve quality of nursing care services.

Optimization Methodology of Quality Measurement of Digital Correlator (디지털 상관기 성능 측정의 최적화 기법)

  • Yeom, Jae-Hwan;Jeong, Goo-Young;Roh, Duk-Gyoo;Oh, Se-Jin;Kim, Kwang-Dong;Lee, Chang-Hoon
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.371-372
    • /
    • 2006
  • In this paper, we propose a method that measures quality of digital correlator. Quality of digital correlator in field of image composition of radio astronomy have as important position for acquisition of radio wave image with high precision. Digital correlator should have wide bandwidth and high precision to study on deep space. Digital correlator, therefore, should be designed to have high speed processing and high precision. But, real time measurement of quality of digital correlator using acquisition data is difficult to compare accuracy of result because digital correlator should process a large quantity of data with high speed. Measurement method of quality, also, has intricate implementation of experiment equipment. this paper present methods that compose experiment equipment without external installation easily and verify quality of digital correlator perfectly.

  • PDF

System Design for Real-Time Measuring of Power Quality and Harmonics Distortion using Digital Signal Processor (Digital Signal Processor를 이용한 실시간 전력 요소와 왜율 측정 시스템 설계)

  • kim, Geun-Jun;Kang, Bongsoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.7
    • /
    • pp.1283-1289
    • /
    • 2016
  • Electrical energy is the essential resource for modern society. Recently, the demand for power was significantly increased. Increase of power demand has lead to a decrease in the power quality. Power quality in modern society has been an important factor that can cause a major problem throughout the home and general industry. Therefore, we need a system for preventing the power quality problems. To avoid power issues, it is important that the measurement of the power quality and initial response. In this paper, we propose real-time power quality measurement system and harmonics monitoring system. We design the system using DM240001 board include dsPIC33FJ256GP710A of microchip. This system can adapt three-phase three-wire system. And optimized the algorithm, we can measure momentary changes of the power system. In addition, designed system can measure harmonics distortion like to VTHD, ITHD and ITDD for 31th harmonics.

A basic plan for the development of standardized measurement technology to improve quality of life (삶의 질 제고를 위한 측정기술표준화 발전 방안)

  • Nam, Sang-Sung
    • Proceedings of the Korea Technology Innovation Society Conference
    • /
    • 2015.11a
    • /
    • pp.580-593
    • /
    • 2015
  • The quality of life is emphasized as one of the important issue in modern society. Such attention to quality of life started getting more attention lately as it is coupled with the country's competitiveness. In spite the quality of life is very significant, the level of the quality of life in the country is not satisfactory. So, the purpose of this study was to analyze the Korean standard measuring technology in terms of the QOL. First, We identified constructs of the QOL on the basis of several studies to derive an analytical framework. Then, We analyzed the distribution of the measurement standard technology in the country in accordance with the framework. The results of the analysis, many of the current measurement technologies described it regardless of the quality of life. Even if the technologies are relevant. they showed a state biased to the economic QOL. This means that QOL was not considered in the measurement technology standard. Therefore the further improved will be needed.

  • PDF