• 제목/요약/키워드: Measurement Program

검색결과 2,491건 처리시간 0.043초

KTX 견인, 재동성능용 계측시스템 구축 (Development of Measurement System for Traction and Braking Performances in KTX)

  • 김석원;한영재;김영국;박찬경;최강윤;김종영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(I)
    • /
    • pp.216-223
    • /
    • 2003
  • In this paper, we introduce the software and hardware of the measuring system for performances of traction and braking in KTX(Korea Train eXpress). The measuring system focuses on the verification of the performance and acquisition of test data. The software controls the hardware of the measuring system, performs the analysis and calculation of measurement data and acts as interface between users and the hardware. For this purpose, three programs, such as a measuring program, a back-up program and a post-processing program, have developed.

  • PDF

논문 : 비선형 GPA 를 이용한 기본 훈련기 터보프롭엔진의 최적계측변수 선정에 관한 연구 (Papers : A Study for Optimal Measurement Parameter Selection of Turboprop Engine for Basic Trainer using Non - Linear GPA)

  • 공창덕;임강택;기자영;오성환
    • 한국항공우주학회지
    • /
    • 제30권1호
    • /
    • pp.105-113
    • /
    • 2002
  • 본 연구에서는 터보프롭 엔진의 정상상태 성능해석 프로그램을 개발하고 비 장창 및 장착조건에서 성능이 해석되었다. 개발프로그램의 검증을 위해 GASTURB 8.0프로그램의 해석결과와 엔진 제작사의 주어진 성능자료를 비교하였다. 개발 프로그램은 GASTURB 8.0과의 비교 결과 5%내의 오차를 나타내어 프로그램의 신뢰성을 확인할 수 있었다. 성능진단을 위해 선형 및 비선형 GPA프로그램을 개발하였으며, 최적계측변수의 선정을 위한 연구를 수행하였다. 계측변수의 종류의 수가 진단의 정확성에 미치는 영향을 알아보기 위하여 선형 및 비선형 GPA프로그램은 다양한 변수를 이용하여 해석 되었다. 그 결고 적절하게 선택된 계측변수는 보다 적은 계측장비로도 신뢰성있고 경제적인 손상 탐지가 가능함을 확인하였다.

원자로 내부배럴집합체 상부면 측정위치 선정 (Selection of Measurement Locations at Inner Barrel Assembly Top Plate in the Reactor)

  • 고도영;김규형;김성환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.734-738
    • /
    • 2012
  • A comprehensive vibration assessment program for the Advanced Power Reactor 1400 reactor vessel internals is established in accordance with the United States Nuclear Regulatory Commission Regulatory Guide 1.20 Revision 3. This paper is related to instruments and measurement locations based on the vibration and stress response analysis results at the inner barrel assembly top plate in the reactor. The analysis results of the inner barrel assembly top plate in the reactor show that the deterministic stress and deformation due to the reactor coolant pump induced pressure pulsations are larger than the random stress and deformation induced by the flow turbulence. The selection of the instruments and measurement locations at Inner barrel assembly top plate in the reactor is essential requirements and very important study process for the vibration and stress measurement program in comprehensive vibration assessment program for the Advanced Power Reactor 1400 reactor vessel internals.

  • PDF

APR1400 내부배럴집합체 상부판 구조해석 및 측정위치 (Structural Analysis and Response Measurement Locations of Inner Barrel Assembly Top Plate in APR1400)

  • 고도영;김규형;김성환
    • 한국소음진동공학회논문집
    • /
    • 제22권5호
    • /
    • pp.474-479
    • /
    • 2012
  • A comprehensive vibration assessment program for the advanced power reactor 1400(APR1400) reactor vessel internals is established in accordance with the united states nuclear regulatory commission regulatory guide 1.20 revision 3. This paper is related to instruments and measurement locations based on the vibration and stress response analysis results of the inner barrel assembly top plate in APR1400. The analysis results of the inner barrel assembly top plate in the reactor show that the deterministic stress and deformation due to the reactor coolant pump induced pressure pulsations are larger than the random stress and deformation induced by the flow turbulence. The selection of the instruments and measurement locations at inner barrel assembly top plate in the reactor is essential requirements and very important study process for the vibration and stress measurement program in comprehensive vibration assessment program for APR1400 reactor vessel internals.

3차원 인체 스캔 데이터의 정확도 검증에 관한 연구 - Cyberware의 WB4 스캐너를 중심으로 - (The Verification of Accuracy of 3D Body Scan Data - Focused on the Cyberware WB4 Whole Body Scanner -)

  • 박선미;남윤자
    • 한국의상디자인학회지
    • /
    • 제14권1호
    • /
    • pp.81-96
    • /
    • 2012
  • The purpose of this study is to provide fundamental information for standardization of 3D body measurement. This research analyzes errors occurring in the process of extracting body size from 3D body scan data. First, as a result of analyzing basic state of the 3D body scanner's calibration, the point number of each section was almost the same, while the right and left as well as the front and back coordinates of the center of gravity are not, showing unstable data. Nevertheless, the latter does not influence on the size of cylinder such as width and circumference. Next, we analyzed point coordinates variations of scan data on a mannequin nude by life casting. The result was great deflection in case of complicated or horizontal sections including the reference point beyond proper distance from centers of four cameras. In case of the mannequin's size, accuracy proves comparatively high in that measurement errors in height, width, depth, and length dimension occurred all within allowable errors, only except chest depth, while there were a lot of measurement errors in a circumference dimension. Secondly, analysis of accuracy of automatic extraction identification program algorithm presented that a semi-automatic measurement program is better than an automatic measurement program. While both of them ate very acute in parts related to crotch, they are not in armpit related parts. Therefore, in extracting of human body size from 3D scan data, what really matters seems to parts related to armpits.

  • PDF

중소기업 수출역량강화사업의 성과지표에 관한 연구 (A Study on the Performance Indicators of SME's International Marketing Program)

  • 한민정;안병수
    • 통상정보연구
    • /
    • 제16권3호
    • /
    • pp.141-158
    • /
    • 2014
  • 본 연구는 중소기업의 해외시장 개척을 돕기 위한 "중소기업 수출역량강화사업"의 성과관리가 적정하게 이루어지고 있는지를 살펴보고 개선방안을 모색함에 연구 목적을 두고 있다. 동 사업은 중소기업이 해당 사업을 통해 해외 진출의 기반을 갖추고 궁극적으로 홀로 설 수 있도록 하는 것을 정책목표로 하고 있다. 이에 논리모델을 기반으로 현행 수출역량강화사업에 대한 성과관리 평가 지표들을 분석한 결과 정량지표중심으로 구성되어 정성지표가 부족하며, 과정에 대한 평가가 부족하고 단기적 결과에만 중점을 두고 있는 것으로 나타났다. 따라서 향후 성과측정을 위한 지표는 결과와 과정에 대한 평가가 균형을 맞추고 중장기적 결과도 함께 포함하는 방향으로 개선해야 할 것이다.

  • PDF

사진 영상을 이용한 머리척추각 자동 측정 프로그램 개발 (Development of an Automatic Measuring Program for the Craniovertebral Angle Using Photographic Image)

  • 예수영;김종순
    • PNF and Movement
    • /
    • 제22권1호
    • /
    • pp.1-11
    • /
    • 2024
  • Purpose: The prevalent use of mobile devices may contribute to musculoskeletal disorders, such as forward head posture (FHP), among users. The measurement of the craniovertebral angle (CVA) using photographic images is frequently employed in assessing FHP. Although manual CVA measurement using photographic images is reliable in clinical settings, computer programs or mobile applications to support tele-physical therapy are not yet fully developed. Therefore, in the current study, we propose an automatic method for extracting CVA from photographic images of FHP subjects to facilitate tele-physical therapy. Methods: To develop the automatic CVA measuring computer program, photographic images were obtained from 10 FHP participants. The location information obtained from the markers attached to the tragus and the spinous process of the seventh cervical vertebra were used as coordinates. Using these coordinates, straight line 1 was generated by connecting the seventh spinous process of the cervical vertebra and the tragus, while straight line 2 was drawn parallel to the coordinate obtained from the seventh spinous process of the cervical vertebra. The arc tangent function was used to calculate the angle between the two straight lines. The automatic CVA measurement computer program utilizing photographic images was developed using MATLAB (ver. 2016b). Results: The results showed that the automatic CVA measurement computer program demonstrated stable repeatability and high accuracy. Conclusion: The proposed approach was able to automatically estimate the CVA using photographic images. The developed computer program can potentially be used for easier and more reliable clinical assessment of FHP.

Development of a Web-Based Program for Cross-Calibration and Record Management of Radiation Measuring Equipment

  • Park, So Hyun;Lee, Rena;Kim, Kyubo;Ahn, Sohyun;Lim, Sangwook;Cho, Samju
    • 한국의학물리학회지:의학물리
    • /
    • 제30권2호
    • /
    • pp.59-63
    • /
    • 2019
  • Purpose: To manage radiation measurement equipment, a web-based management program has been developed in this study. Materials and Methods: This program is based on a web service and Java Server Pages (JSP) and employs compatibility and accessibility. Results: The first step in the workflow has been designed to create accounts for each user or organization and to log in. The program consists of two parts: fields for listed instruments, and measurement information. The instruments for measuring radiation listed in this program are as follows: ionization chambers, survey meters, thermometers, barometers, electrometers, and phantoms. Instrument properties can be put in the recording fields and browsing for associated instruments can be performed. The main part of the program is the cross-calibration for each ion chamber. For instance, the ionization chamber to be used as a relative dosimeter can be registered by cross-calibration data with a reference chamber calibrated by an accredited laboratory. This program supports methods using the central axis transfer theory for cross-calibration for the ionization chambers. The reference and field ionization chambers were placed in a solid water phantom along the beam central axis at two different depths, and then the positions were switched. Each measured value was used for calculating the cross-calibration factor. Conclusions: Because many instruments are used and managed in radiation oncology departments, systematic, traceable recording is very important. The web-based program developed in this study is expected to be used effectively in the maintenance of radiation measurement instruments.

Automatic Hand Measurement System from 2D Hand Image for Customized Glove Production

  • Han, Hyun Sook;Park, Chang Kyu
    • 한국의류산업학회지
    • /
    • 제18권4호
    • /
    • pp.468-476
    • /
    • 2016
  • Recent advancements in optics technology enable us to realize fast scans of hands using two-dimensional (2D) image scanners. In this paper, we propose an automatic hand measurement system using 2D image scanners for customized glove production. To develop the automatic hand measurement system, firstly hand scanning devices has been constructed. The devices are designed to block external lights and have user interface to guide hand posture during scanning. After hands are scanned, hand contour is extracted using binary image processing, noise elimination and outline tracing. And then, 19 hand landmarks are automatically detected using an automatic hand landmark detection algorithm based on geometric feature analysis. Then, automatic hand measurement program is executed based on the automatically extracted landmarks and measurement algorithms. The automatic hand measurement algorithms have been developed for 18 hand measurements required for custom-made glove pattern making. The program has been coded using the C++ programming language. We have implemented experiments to demonstrate the validity of the system using 11 subjects (8 males, 3 females) by comparing automatic 2D scan measurements with manual measurements. The result shows that the automatic 2D scan measurements are acceptable in the customized glove making industry. Our evaluation results confirm its effectiveness and robustness.

APR1400 원자로 내부구조물 종합진동평가 측정센서 선정 (Selection of Measuring Sensors for Reactor Vessel Internals Comprehensive Vibration Assessment Program in Advanced Power Reactor 1400)

  • 고도영;이재곤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 추계학술대회 논문집
    • /
    • pp.433-438
    • /
    • 2010
  • Reactor vessel internals comprehensive vibration assessment program(RVI CVAP) is one of the necessary tests to ensure the safety of nuclear power plants. RVI CVAP of U.S. Nuclear Regulatory Commission Regulatory Guide 1.20(U.S. NRC R.G. 1.20) consists of the analysis, measurement, and inspection. One of the core technologies of the measurement program for RVI CVAP is to select suitable sensors. We analyzed RVI design data of Palo Verde nuclear generating station(U.S.) and Yonggwang nuclear generating station(Korea) and investigated measuring sensors used in both of them; moreover, we investigated sensors used for measurement of RVI CVAP for the last 20 years throughout the world. Based on these results, we selected the most suitable sensors for RVI CVAP in Advanced Power Reactor 1400(APR1400).

  • PDF