• Title/Summary/Keyword: Measurement Indicator

Search Result 495, Processing Time 0.034 seconds

Comparison of the Frequency Bands for the Wireless Sensor Networks in the Building Environment

  • Lee, Eunae;Lee, Jeongmin;Kim, Dong Sik
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.8 no.2
    • /
    • pp.23-30
    • /
    • 2016
  • In this paper, for the pratical building envoronments, the propagation properties of the electromagnetic waves of the sub-1GHz bands, including the 447MHz, 868MHz, and 715MHz, and the 2.4GHz band are experimentally observed in therms of the received signal strength indicator (RSSI) value. The compasion of the frequency bands can be utilized to efficiently construct the wireless sensor networks (WSN) for the building automation control. In order to measure the RSSI values in the building, an RSSI measurement system is first designed, in which the master part can transmit data packets and measure the corresponding RSSI values, and the slave part can respond the received data packets. Using the measurement system, the RSSI values are then experimentally measured at four types of building enviroments. From the experimental result analysis, we could notice that the sub-1GHz, especially the 447MHz band, showd a good communication performance for the building environment and could provide an efficient WSN construction when the data rate is relatively low.

Feasibility of simultaneous measurement of cytosolic calcium and hydrogen peroxide in vascular smooth muscle cells

  • Chang, Kyung-Hwa;Park, Jung-Min;Lee, Moo-Yeol
    • BMB Reports
    • /
    • v.46 no.12
    • /
    • pp.600-605
    • /
    • 2013
  • Interplay between calcium ions ($Ca^{2+}$) and reactive oxygen species (ROS) delicately controls diverse pathophysiological functions of vascular smooth muscle cells (VSMCs). However, details of the $Ca^{2+}$ and ROS signaling network have been hindered by the absence of a method for dual measurement of $Ca^{2+}$ and ROS. Here, a real-time monitoring system for $Ca^{2+}$ and ROS was established using a genetically encoded hydrogen peroxide indicator, HyPer, and a ratiometric $Ca^{2+}$ indicator, fura-2. For the simultaneous detection of fura-2 and HyPer signals, 540 nm emission filter and 500 nm~ dichroic beamsplitter were combined with conventional exciters. The wide excitation spectrum of HyPer resulted in marginal cross-contamination with fura-2 signal. However, physiological $Ca^{2+}$ transient and hydrogen peroxide were practically measurable in HyPer-expressing, fura-2-loaded VSMCs. Indeed, distinct $Ca^{2+}$ and ROS signals could be successfully detected in serotonin-stimulated VSMCs. The system established in this study is applicable to studies of crosstalk between $Ca^{2+}$ and ROS.

The Current State of and Barriers to Quality Measurement, and Quality Managers' Reported Evaluation on Quality Indicators in Korea (국내 질 향상부서 중심의 질 지표 측정 현황, 장애요인과 평가)

  • Hwang Jee-In
    • Health Policy and Management
    • /
    • v.15 no.4
    • /
    • pp.26-45
    • /
    • 2005
  • The purposes of this study were to Identify the .level of measurement on quality Indicators and evaluate the existing indicators in order to determine the priority of quality indicators' application in Korean general hospitals. A survey was conducted using a questionnaire. The subjects were quality managers working at general hospital having over 300 beds. The criteria were relevance, reliability, precision, impact, application, and preference to evaluate quality indicators. According to these six criteria, each indicator was evaluated on a five point scale(5: excellent, 1: poor). The response rate was $40.4\%$. The hospitals have monitored the average of 3.8 indicators(median 4). The indicators such as return to operating room, unplanned readmission, cancellation of booked operations, death, hospital infection, cesarean section rate, volume per disease or procedure, readmission, re-operation, blood transfusion, and post-procedural complications were frequently measured. The top ten quality indicators in the evaluation by its relevance, validity, reliability, impact, preference and application were decubitus ulcer, clean wound infection, fall, unplanned return to operation room, transfusion reactions, foreign body left In during procedure, unplanned readmission, wound infection after contaminated surgery, postoperative hemorrhage/hematoma, and cesarean section rate in order. The high priority quality indicators frequently measured could be used as primary national indicators. Standardized guidelines about monitoring indicators and the utilization will preliminarily be needed to compare and reuse the data for various purposes and improve the quality of care continuously.

A New Method on the Measurement of Catalase Activity of Panax ginseng C.A. Meyer Tissues (인삼조직에서 Catalase Activity측정에 관한 새로운 Method)

  • Yang, Deok-Cho;Chae, Quae;Yoon, Jae-Jun;Lee, Sung-Jong;Lee, Ae-Ra
    • Journal of Ginseng Research
    • /
    • v.9 no.2
    • /
    • pp.154-162
    • /
    • 1985
  • We report a newassay method on the measurement of the catalase activity, whose utilzation value is considered to be remarkable in the field of plant biochemistry. We named this method as a De-Coupling method. The essence of de-coupling method is the separation between the enzyme reaction and the indicator reaction. The optimum condition of the enzyme reaction was found to be following: on addition of 1 ml of substrate (H2O2: 20mM) to the fixture of the crude extract of enzyme (volume: 0.2 ml) and the ammonium phosphate buffer (volume: 1.8 ml; 0.93 M phosphate, 1.6M NHB, 2.5 M methanol, pH 7.0). After 30, 60 and 90 seconds of the enzyme reactions are proceeded, the reactions are terminated by 25% of tai-chloro-acetate (final concentration of 5%), respectively. The precipitated materials by tai-chloro-acetate was removed by the centrifugation (2000g, 10minutes). Formaldehyde produced in the enzymatic reaction was reacted with 2ml of acetylacetone (60mM). The indicator reaction -(HANTSCH REAKT10N)- in which lutidine is formed, was proceeded for 60 minutes at $25^{\circ}C$.

  • PDF

Statistical Analysis of Work Performance Indicator (작업 성과지표의 통계적 분석 방법에 관한 연구)

  • Moon, Hyo-Gi;Yu, Jung-Ho;Kim, Chang-Duk
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.947-952
    • /
    • 2007
  • The construction project is composed of individual trade which is consists of each activity. and the performance of each activity is the lowest level to influence the project performance. Consequently, It is essential to measure and evaluate the performance of the each assignment. But the existing performance measurement have mainly focussed on company level and project level. Therefore, this paper select PPC as the indicator of a activity and, suggests the analysis method of indicators for a goal-oriented management and continuous improvement through a statistical control techniques.

  • PDF

Development of Measurement Model of Educational Activities Quality of Students in Pedagogical Higher Education: Theoretical Methodical Aspect

  • Ponomarova, Halyna F.;Stepanets, Ivan O.;Vasylenko, Olena M.
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.10
    • /
    • pp.91-96
    • /
    • 2022
  • Article materials reflect the results of scientific research and generalization of experience concerning quality measurement of student's educational activities in the context of innovative development of the educational process, which is ensured by introducing educational innovations. The main point of monitoring of higher education students' activities and also phenomenon of education quality, particularly its results, are determined in the research. Guided by the scientific theory and personal experience of scientific and pedagogical activities, the attempt to single out the key components, important indicators and to introduce component indicator model of quality of higher education students' activities on the qualimetry base has been performed. Methodical solutions concerning the application of the developed model to determine the dynamics of pedagogical students' educational achievements by particular educational components in the process of innovative development of educational process are proposed. The advanced studies that relate to the development of methods for monitoring the quality of pedagogical higher education students' activities on the basis of systemic, competence and qualimetry approaches taking into account the levels of education and chosen specialties have been decided.

Determination of Background Gray-level for Accurate Measurement of Particles in using Image Processing Method (영상처리 기법을 이용한 입경 측정시 배경 명도가 측정 정밀도에 미치는 영향)

  • Koh, Kwang-Uoong;Lee, Sang-Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.4
    • /
    • pp.599-607
    • /
    • 2000
  • In this study, experiments have been performed to examine the effects of background gray-level on the depth-of-field and on the in-focus criteria. The normalized value of contrast(VC) and the gradient indicator(GI) were used as the in-focus criteria for the small and the large size-ranges of particles, respectively. The slightly larger number of pixels were detected with the brighter background. The maximum of the normalized value of contrast(VCmax) is decreased with the brighter background and its deviation from that with the background gray-level of 160 turned out to be about $pm$15% when the background gray-level changes from 100 to 200. However, the maximum gradient indicator(GImax) changes with the background gray-level within only $pm$5%. The depth-of-field for the VC-applicable particle-size range is largely dependent on the background gray-level. On the other hand, the depth-of-field for the GI-applicable particle-size range changes only slightly with the background gray-level. To keep the normalized standard deviation of the particle size within 0.1, the background gray-level should be set 160$pm$20 for both the VC-applicable and GI-applicable ranges which cover the particle size between $10{\mu}m$ and $300{\mu}m$.

Accuracy Evaluation of a Non-Contact Rotational Torque Measurement System by Using Telemeter (원격전송장치를 이용한 비접촉식 회전 토크 측정장치의 정확도 평가)

  • Kim, G.S.;Joo, J.W.;Kwon, Y.H.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.1
    • /
    • pp.63-70
    • /
    • 1994
  • This paper presents manufacturing and evaluation of a non-contact rotational torque measurement system which consists of torque cell, telemeter system, transmitter and receiver coil, transmitter, receiver and telemeter indicator. Static calibration test results show that the system has a maximum uncertaintry of 05% or less. A standar calibration system for rotational torque is used to evaluate the measurement system, As a result, the maximum uncertainty for measuring rotational torque by this system is 2% or less. We may conclude that the measurement system is sufficient to measure rotational torque of shaft in industry.

  • PDF

Improved Adaptive Smoothing Filter for Indoor Localization Using RSSI

  • Kim, Jung-Ha;Seong, Ju-Hyeon;Ha, Yun-Su;Seo, Dong-Hoan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.2
    • /
    • pp.179-186
    • /
    • 2015
  • In the indoor location estimation system, which has recently been actively studied, the received signal strength indicator contains a high level of noise when measuring the signal strength in the range between two nodes consisting of a receiver and a transceiver. To minimize the noise level, this paper proposes an improved adaptive smoothing filter that provides different exponential weights to the current value and previous averaged one of the data that were obtained from the nodes, because the characteristic signal attenuation of the received signal strength indicator generally has a log distribution. The proposed method can effectively decrease the noise level by using a feedback filter that can provide different weights according to the noise level of the obtained data and thus increase the accuracy in the distance and location without an additional filter such as the link quality indicator, which can verify the communication quality state to decrease the range errors in the indoor location recognition using ZigBee based on IEEE 802.15.4. For verifying the performance of the proposed improved adaptive smoothing filter, actual experiments are conducted in three indoor locations of different spatial sections. From the experimental results, it is verified that the proposed technique is superior to other techniques in range measurement.

A Study on Evaluation Criteria for quantitatively OSS Selection (정량적인 OSS 선정을 위한 평가지표 연구)

  • Lee, Hoo-Jae;Kim, Doo-Yeon;Choi, Il-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1863-1871
    • /
    • 2012
  • Utilization of the former OSS was mainly focused on the usage of system applications such as operating system and DBMS. However, nowadays many companies are trying to make use of OSS based on the application rather than the system software. However, selection of base OSS is the most important to develop of application for utilizing OSS. The scope of existing OSS evaluation studies is covered the entire OSS quality. Thus existing studies of evaluation of OSS selection is insufficient. Also, the result of assessment is based on qualitative measurement rather than quantitative ones. In this paper, we derives only the indicators for selection among the existing OSS assessment indicators and suggests the assessment indicator that is capable of quantitative assessment in accordance with the characteristics of the project. The proposed assessment indicator is divided into an initial assessment indicator that can be assessed with only the information within the OSS community, and the detailed assessment indicator through metrics to make quantitative measurements possible. In this way, an objective basis can be provided through quantitative scores & indicators when selecting OSS.