• Title/Summary/Keyword: Measurement Indicator

Search Result 495, Processing Time 0.025 seconds

Implementation of the Module Risk Levels Measurement Tools for Web Application (웹 어플리케이션의 모듈위험수준 측정 도구의 구현)

  • Kim, Jee-Hyun;Park, Chel
    • Journal of the Korea Society of Computer and Information
    • /
    • v.7 no.2
    • /
    • pp.87-94
    • /
    • 2002
  • This paper implemented the tools to measure the risk of the modules for the web application project written in ASP, using the Indicator of the Module Risk Levels. The Indicator of that is developed by GSFC group in NASA based on structural programming language and gives us software product quality metrics. The implemented tools examined with the ASP projects of the practical business. As the results the data shows the module risk levels easily, and then the data affects the maintenance to improve the application quality.

  • PDF

A two-stage damage detection method for truss structures using a modal residual vector based indicator and differential evolution algorithm

  • Seyedpoor, Seyed Mohammad;Montazer, Maryam
    • Smart Structures and Systems
    • /
    • v.17 no.2
    • /
    • pp.347-361
    • /
    • 2016
  • A two-stage method for damage detection in truss systems is proposed. In the first stage, a modal residual vector based indicator (MRVBI) is introduced to locate the potentially damaged elements and reduce the damage variables of a truss structure. Then, in the second stage, a differential evolution (DE) based optimization method is implemented to find the actual site and extent of damage in the structure. In order to assess the efficiency of the proposed damage detection method, two numerical examples including a 2D-truss and 3D-truss are considered. Simulation results reveal the high performance of the method for accurately identifying the damage location and severity of trusses with considering the measurement noise.

Intra- and inter-rater reliability of muscle thickness measurement of the tibialis anterior using different inward pressures

  • Lee, Seong-Joo;Lim, Ji Young;Lee, Chang-Hyung;Park, Dae-Sung
    • Physical Therapy Rehabilitation Science
    • /
    • v.8 no.4
    • /
    • pp.218-224
    • /
    • 2019
  • Objective: This reliability study examined the effects of applying varying induced inward pressures using a transducer placed at 0° neutral ankle position (NEU) and 15° ankle dorsiflexion (DF) on tibialis anterior (TA) muscle thickness using a custom-made device with a force indicator during rehabilitative ultrasound imaging. Design: Cross-sectional study. Methods: Twenty-four healthy subjects were recruited in this study. Two examiners measured the muscle thickness of the TA at 0° NEU and 15° DF in 3 conditions of inward pressures (1.0 N, 2.0 N, and 4.0 N) using a custom-made holder. The muscle thickness was measured three times for each of the conditions arranged in random order. For intra- and inter-rater reliability, the intraclass correlation coefficients (ICCs) with 95% confidence intervals, standard error of measurement, minimal detectable change, and coefficient of variation were analyzed. One-way repeated measures analysis of variance was conducted for investigating changes of TA muscle thickness according to the inward pressures of the transducers. Results: The intra-rater reliability of TA muscle thickness measurement was excellent (ICC3,1: 0.92-0.96) for all conditions (at both ankle joint angles per varying inward pressure). Likewise, the inter-rater reliability of TA muscle thickness measurement was excellent (ICC2,1: 0.89-0.97) under same conditions. The mean of TA thickness showed the trend of decreasing significantly with increased inward pressures at all ankle joint angles (p<0.05). Conclusions: Use of this custom-made device with a force indicator is useful to accomplish the high intra- and inter-rater reliability of TA muscle thickness measurement at both ankle joint angles in reducing the measurement error.

The Use of Sticker Type Temperature Indicator in Stellate Ganglion Block (성상신경절 차단시 부착형 피부온도계의 사용 경험)

  • Yoon, Duck-Mi;Oh, Hung-Kun;Keiji, Ishizaki;Fujita, Tatsushi
    • The Korean Journal of Pain
    • /
    • v.7 no.1
    • /
    • pp.49-52
    • /
    • 1994
  • Measurement of skin temperature is most frequently used to evaluate effect of sympathetic block. Sticker type skin temperature indicator, $ProChecker^{(R)}$, uses metamocolor, which changes the darkness of the color by giving and taking of electrons in response to temperature. We examined the accuracy of this skin temperature indicator in pain clinic patients who were treated with stellate ganglion block. Ten minutes before, and 10~20 minutes after stellate ganglion block, skin temperature on both dorsum of hand were measured using both $ProChecker^{(R)}$ and thermography concurrently. The results showed that skin temperature measured by $ProChecker^{(R)}$ was feasible, in correlation to thermography. Sticker type temperature indicator ($ProChecker^{(R)}$) is concluded as a useful monitor of skin temperature during nerve block in outpatient clinics.

  • PDF

Centralized Kalman Filter with Adaptive Measurement Fusion: its Application to a GPS/SDINS Integration System with an Additional Sensor

  • Lee, Tae-Gyoo
    • International Journal of Control, Automation, and Systems
    • /
    • v.1 no.4
    • /
    • pp.444-452
    • /
    • 2003
  • An integration system with multi-measurement sets can be realized via combined application of a centralized and federated Kalman filter. It is difficult for the centralized Kalman filter to remove a failed sensor in comparison with the federated Kalman filter. All varieties of Kalman filters monitor innovation sequence (residual) for detection and isolation of a failed sensor. The innovation sequence, which is selected as an indicator of real time estimation error plays an important role in adaptive mechanism design. In this study, the centralized Kalman filter with adaptive measurement fusion is introduced by means of innovation sequence. The objectives of adaptive measurement fusion are automatic isolation and recovery of some sensor failures as well as inherent monitoring capability. The proposed adaptive filter is applied to the GPS/SDINS integration system with an additional sensor. Simulation studies attest that the proposed adaptive scheme is effective for isolation and recovery of immediate sensor failures.

Minimizing the Measurement Error from Gas Compositions of Gas Vent in Sanitary Landfill (쓰레기 매립지 가스 포집관에서 가스조성에 따른 계측오차의 최소화)

  • 이해승;이문형
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.1
    • /
    • pp.28-35
    • /
    • 2002
  • A methods of minimizing the measurement error brought from gas compositions was proposed by Hot wire Anemometer which don't have measurement resistance to calculate of gas vent in sanitary landfill. It was determined measurement error to compared velocity at the center of pipe to calculate using rotor meter and density gas compositions with velocity at the center of pipe to calculate using water head indicator which don't have measurement resistance. Considering the methods of minimizing gas velocity in sanitary landfill using hot wire anemometer and rotor meter, it was found to minimize within 10% as error of gas vent in sanitary landfill.

An Analysis on the Reduction of Measurement Time Using Interpolation Algorithm in Near-field RCS Measurements for Aircraft Shape (항공기 형상에 대한 근전계 RCS 측정에서 내삽 알고리즘을 이용한 측정시간 단축에 대한 분석)

  • Park, Homin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.339-346
    • /
    • 2022
  • The importance of stealth technology is increasing in modern warfare, and Radar Cross Section(RCS) is widely used as an indicator of stealth technology. It is useful to measure RCS using an image-based near-field to far-field transformation algorithm in short-range monostatic conditions. However, the near-field measurement system requires a longer measurement time compared to other methods. In this work, it is proposed to reduce the measured data using an interpolation method in azimuth angular domain. The calculated far-field RCS values according to the sampling rate is shown, and the performance of the algorithm applied with interpolation in the angular domain is presented. It is shown that measurement samples can be reduced several times by using the redundancy in the angular domain while producing results similar to the conventional method.

Determination of the Dissociation Constant of Thymol Blue with Diode-Laser/Fiber-Optic Thermal Lensing Spectroscopy

  • 김성호;노영순
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.8
    • /
    • pp.822-824
    • /
    • 1998
  • The simple and convenient measurement of the dissociation constant of an indicator, thymol blue, was achieved by using a portable diode-laser/fiber-optic thermal lensing spectroscopy, which consisted of a visible diode laser, a photodiode, and an optical fiber. It gives comparable results to the cited value obtained from a conventional UV/VIS spectroscopy.

Long term structural health monitoring for old deteriorated bridges: a copula-ARMA approach

  • Zhang, Yi;Kim, Chul-Woo;Zhang, Lian;Bai, Yongtao;Yang, Hao;Xu, Xiangyang;Zhang, Zhenhao
    • Smart Structures and Systems
    • /
    • v.25 no.3
    • /
    • pp.285-299
    • /
    • 2020
  • Long term structural health monitoring has gained wide attention among civil engineers in recent years due to the scale and severity of infrastructure deterioration. Establishing effective damage indicators and proposing enhanced monitoring methods are of great interests to the engineering practices. In the case of bridge health monitoring, long term structural vibration measurement has been acknowledged to be quite useful and utilized in the planning of maintenance works. Previous researches are majorly concentrated on linear time series models for the measurement, whereas nonlinear dependences among the measurement are not carefully considered. In this paper, a new bridge health monitoring method is proposed based on the use of long term vibration measurement. A combination of the fundamental ARMA model and copula theory is investigated for the first time in detecting bridge structural damages. The concept is applied to a real engineering practice in Japan. The efficiency and accuracy of the copula based damage indicator is analyzed and compared in different window sizes. The performance of the copula based indicator is discussed based on the damage detection rate between the intact structural condition and the damaged structural condition.