• Title/Summary/Keyword: Measurement Current Source

Search Result 249, Processing Time 0.026 seconds

The Measurement of the Harmonic Currents in the Household & Office Appliances (가정.사무용 기기의 고조파 전류 측정)

  • Seo, J.C.;Kang, Y.C.;Kim, S.S.;Nam, S.R.;Park, J.K.;Myoung, S.H.;Kang, Y.S.;Choi, H.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.149-151
    • /
    • 1996
  • This paper reports the measurement results of the harmonic currents in the household and office appliances. The harmonic currents of 10 items are measured up to 20th order using the no distortion source. These results can be used as a raw data in determining the harmonic current limit in the household and office appliances.

  • PDF

Effects of Gradient Switching Noise on ECD Source Localization with the EEG Data Simultaneously Recorded with MRI (MRI와 동시에 측정한 뇌전도 신호로 전류원 국지화를 할 때 경사자계 유발 잡음의 영향 분석)

  • Lee H. R.;Han J. Y.;Cho M. H.;Im C. H.;Jung H. K.;Lee S. Y.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.2
    • /
    • pp.108-115
    • /
    • 2003
  • Purpose : To evaluate the effect of the gradient switching noise on the ECD source localization with the EEG data recorded during the MRI scan. Materials and Methods : We have fabricated a spherical EEG phantom that emulates a human head on which multiple electrodes are attached. Inside the phantom, electric current dipole(ECD) sources are located to evaluate the source localization error. The EEG phantom was placed in the center of the whole-body 3.0 Tesla MRI magnet, and a sinusoidal current was fed to the ECD sources. With an MRI-compatible EEG measurement system, we recorded the multi channel electric potential signals during gradient echo single-shot EPI scans. To evaluate the effect of the gradient switching noise on the ECD source localization, we controlled the gradient noise level by changing the FOV of the EPI scan. With the measured potential signals, we have performed the ECD source localization. Results : The source localization error depends on the gradient switching noise level and the ECD source position. The gradient switching noise has much bigger negative effects on the source localization than the Gaussian noise. We have found that the ECD source localization works reasonably when the gradient switching noise power is smaller than $10\%$ of the EEG signal power. Conclusion : We think that the results of the present study can be used as a guideline to determine the degree of gradient switching noise suppression in EEG when the EEG data are to be used to enhance the performance of fMRI.

  • PDF

Comparative Measurement of Radioactivity with Standard Gamma-ray Ionization Chamber System (표준 감마선 전리함 장치에 의한 방사능 비교 측정)

  • Park, Tae-Soon;Woo, Dong-Ho;Oh, Pil-Jae;Hwang, Sun-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.9 no.1
    • /
    • pp.11-18
    • /
    • 1984
  • A Standard gamma-ray ionization chamber system was developed with a well type ionization chamber and micro current measuring circuit. Micro current was measured by the automatic Townsend balance with stepwise compensation method. For gamma emitting nuclides such as $^{241}Am,\;^{133}Ba,\;^{60}Co,\;^{134}Cs,\;^{137}Cs,\;and\;^{22}Na$ relative calibration factors to $^{226}Ra$ reference source were calculated and detection .efficiency curve was determined as a fudnction of gamma energy.

  • PDF

A Study on the Analysis of Harmonic Injection and Emission for Power System (전력계통 고조파 유입 유출 분석에 관한 연구)

  • Wang, Yong-Peel;Jeong, Jong-Won;Kim, Se-Dong;Kwak, No-Hong;Jeon, Young-Soo;Park, Sang-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.203-205
    • /
    • 2007
  • A method is proposed in this paper to determine the harmonic contributions of a customer at the point of common coupling. The method can quantify customer and utility responsibilities for limit violations caused by either harmonic source changes or harmonic impedance changes. It can be implemented in current power quality monitors and digital revenue meters. The method is comparison of measurement phase angles between harmonic voltage and current. The proposed method has been applied to the test system. The study results have indicated the accuracy of harmonic injection and emission for customer and utility.

  • PDF

Rapid Thermal Alloy of Fabricated Diode by Rapid Thermal Diffusion (고속 열확산에 의해 제작된 다이오드의 Rapid Thermal Alloy)

  • 이동엽;이영희
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.2
    • /
    • pp.63-67
    • /
    • 1992
  • Shallow $p^{+}-n,n^{+}-p$ diodes have been fabricated using rapid thermal diffusion by solid diffusion source and rapid thermal alloying with pure Aluminum. Diode area and junction depth are designed about 2.83$[\times}10^{-3}cm^{2}$ and 250nm, respectively. Electrical characteristics of $p^{+}-n$ diode show that the ideality factor is 1.04 and reverse current density is 29.3nA/$cm^{2}$, respectively. On the other hand, those of $n^{+}-p$ diode show that the ideality factor is 1.05 and reverse current density is 85.2pA/$cm^{2}$. The reverse currents are measured at 5V reverse bias after rapid thermal alloying for all the measurement.

  • PDF

Analysis of Harmonic Incoming and Outgoing for Transmission System (송전계통 고조파 유입/유출 분석)

  • Wang, Y.P.;Choi, S.Y.;Kwak, N.H.;Jeon, Y.S.;Park, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.561-562
    • /
    • 2007
  • A method is proposed in this paper to determine the harmonic contributions of a customer at the point of common coupling. The method can quantify customer and utility responsibilities for limit violations caused by either harmonic source changes or harmonic impedance changes. It can be implemented in current power quality monitors and digital revenue meters. The method is comparison of measurement phase angles between harmonic voltage and current. The proposed method has been applied to the test system. The study results have indicated the accuracy of harmonic injection and emission for customer and utility.

  • PDF

Characterization of a Remote Inductively Coupled Plasma System (원격 유도결합 플라즈마 시스템의 특성 해석)

  • Kim, Yeong-Uk;Yang, Won-Kyun;Joo, Jung-Hoon
    • Journal of Surface Science and Engineering
    • /
    • v.41 no.4
    • /
    • pp.134-141
    • /
    • 2008
  • We have developed a numerical model for a remote ICP(inductively coupled plasma) system in 2D and 3D with gas distribution configurations and confirmed it by plasma diagnostics. The ICP source has a Cu tube antenna wound along a quartz tube driven by a variable frequency rf power source($1.9{\sim}3.2$ MHz) for fast tuning without resort to motor driven variable capacitors. We investigated what conditions should be met to make the plasma remotely localized within the quartz tube region without charged particles' diffusing down to a substrate which is 300 mm below the source, using the numerical model. OES(optical emission spectroscopy), Langmuir probe measurements, and thermocouple measurement were used to verify it. To maintain ion current density at the substrate less than 0.1 $mA/cm^2$, two requirements were found to be necessary; higher gas pressure than 100 mTorr and smaller rf power than 1 kW for Ar.

Application of Fluorescence Excitation Emission Matrices for Diagnosis and Source Identification of Watershed Pollution : A Review (유기물 형광분석법을 활용한 유역 오염 진단 및 오염원 추적: 문헌 연구)

  • Kandaddara Badalge Nipuni Dineesha;Jin Hur;Byung Joon Lee
    • Journal of Korean Society on Water Environment
    • /
    • v.39 no.1
    • /
    • pp.87-101
    • /
    • 2023
  • The constituents of a watershed control a wide range of ecosystem processes, such as, carbon sequestration, nutrient retention, and biodiversity preservation. Maintenance of a healthy watershed is advantageous to humans in many direct and indirect ways. Dissolved organic matter fluorescence analysis is one of the most commonly utilized parameters for water quality measurement, pollution source tracking, and determination of the ecological state of a watershed. Throughout the recent decades, the advancement in data processing, instrumentation, and methods has resulted in many improvements in the area of watershed study with fluorescence analysis. The current trend of coupling advanced instrumentations and new comparative parameters, such as, microplastics of different types, antibiotics, and specific bacterial contaminants have been reported in watershed studies. However, conventional methodologies for obtaining fluorescence excitation emission matrices and for calculating the fluorescence and spectral indices are preferred to advanced methods, due to their easiness and simple data collection. This review aims to gain a general understanding of the use of dissolved organic matter fluorescence analysis for diagnosis and source identification of watershed pollutions, by focusing on how the studies have utilized fluorescence analysis to improve existing knowledge and techniques in recent years.

32-Channel Bioimpedance Measurement System for the Detection of Anomalies with Different Resistivity Values (저항률이 다른 내부 물체의 검출을 위한 32-채널 생체 임피던스 측정 시스템)

  • 조영구;우응제
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.6
    • /
    • pp.503-510
    • /
    • 2001
  • In this paper. we describe a 32-channel bioimpedance measurement system It consists of 32 independent constant current sources of 50 kHz sinusoid. The amplitude of each current source can be adjusted using a 12-bit MDAC. After we applied a pattern of injection currents through 32 current injection electrodes. we measured induced boundary voltages using a variable-gain narrow-band instrumentation amplifier. a Phase-sensitive demodulator. and a 12-bit ADC. The system is interfaced to a PC for the control and data acquisition. We used the system to detect anomalies with different resistivity values in a saline Phantom with 290mm diameter The accuracy of the developed system was estimated as 2.42% and we found that anomalies larger than 8mm in diameter can be detected. We Plan to improve the accuracy by using a digital oscillator improved current sources by feedback control, Phase-sensitive A/D conversion. etc. to detect anomalies smaller than 1mm in diameter.

  • PDF

Minimization Method of Measurement Noise for Satellite Clock Anomaly Detection (위성시계 이상검출을 위한 측정잡음 최소화 기법)

  • Seo, Kiyeol;Park, Sanghyun;Jang, Wonseok;Kim, Youngki
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.23 no.6
    • /
    • pp.505-510
    • /
    • 2013
  • In order to detect and identify the GPS clock anomaly in the Differential GPS real environment, this paper addresses a method for minimizing the measurement noise of reference receivers. It estimates the real measurement noise that removed the uncommon error source from pseudorange measurement to minimize the measurement noise. Based on the output of two reference receivers, it first removes the uncommon errors, then optimizes the measurement noise by applying the correction data. Finally, it detects and identifies the satellite clock anomaly using the minimized measurement noise. The method will increase the availability of current DGPS reference system.