L-spine Bone SPECT/CT에서 획득된 저선량 CT 영상을 이용한 용적 골밀도 결과의 유용성 (Usefulness of volumetric BMD measurement by using low dose CT image acquired on L-spine Bone SPECT/CT)

  • 고현수;박순기;김은혜;최종숙;정우영;이동윤
    • 핵의학기술
    • /
    • 제27권2호
    • /
    • pp.99-109
    • /
    • 2023
  • Purpose: CT scan makes up for the weak point of the nuclear medicine image having a low resolution and also were used for attenuation correction on image reconstruction. Recently, many studies try to make use of CT images additionally, one of them is to measure the bone mineral density(BMD) using Quantitative CT(QCT) software. BMD exams are performed to scan lumbar and femur with DXA(Dual-Energy X-Ray Absorptiometry) in order to diagnose bone disease such as osteopenia, osteoporosis. The purpose of this study is to identify the usefulness of QCT_BMD analyzed with low dose CT images on L-spine Bone SPECT/CT comparing with DXA_BMD. Materials and Methods: Fifty five women over 50 years old (mean 66.4 ± 9.1) who took the both examinations(L-spine Bone SPECT/CT with SIEMENS Intevo 16 and DXA scan with GE Lunar prodigy advance) within 90 days from April 2017 to July 2022, BMD, T-score and disease classification were analyzed. Three-dimensional BMD was analyzed with low dose CT images acquired on L-spine Bone SPECT/CT scan on Mindways QCT PROTM software and two-dimensional BMD was analyzed on DXA scan. Basically, Lumbar 1-4 were analyzed and the patients who has lesion or spine implants on L-spine were excluded for this study. Pearson's correlation analysis was performed in BMD and T-score, chi-square test was performed in disease classification between QCT and DXA. Results: On 55 patients, the minimum of QCT_BMD was 18.10, maximum was 166.50, average was 82.71 ± 31.5 mg/cm3. And the minimum of DXA-BMD was 0.540, maximum was 1.302, average was 0.902 ± 0.201 g/cm2, respectively. The result shows a strong statistical correlation between QCT_BMD and DXA_BMD(p<0.001, r=0.76). The minimum of QCT_T-score was -5.7, maximum was -0.1, average was -3.2 ± 1.3 and the minimum of DXA_T-score was -5.0, maximum was 1.7, average was -2.0 ± 1.3, respectively. The result shows a statistical correlation between QCT T-score and DXA T-score (p<0.001, r=0.66). On the disease classification, normal was 5, osteopenia was 25, osteoporosis was 25 in QCT and normal was 10, osteopenia was 25, osteoporosis was 20 in DXA. There was under-estimation of bone decrease relatively on DXA than QCT, but there was no significant differences statistically by chi-square test between QCT and DXA. Conclusion: Through this study, we could identify that the QCT measurement with low dose CT images QCT from L-Spine Bone SPECT/CT was reliable because of a strong statistical correlation between QCT_BMD and DXA_BMD. Bone SPECT/CT scan can provide three-dimensional information also BMD measurement with CT images. In the future, rather than various exams such as CT, BMD, Bone scan are performed, it will be possible to provide multipurpose information via only SPECT/CT scan. In addition, it will be very helpful clinically in the sense that we can provide a diagnosis of potential osteoporosis, especially in middle-aged patients.

정모두부방사선사진에서 하악골 우각부 영상확대 및 이의 보정에 관한 3차원 CT영상 연구 (Three-dimensional CT image study on the correction of gonial angle width enlarged on frontal cephalogram)

  • 황현식;은춘선;황정현;임회정
    • 대한치과교정학회지
    • /
    • 제35권4호
    • /
    • pp.251-261
    • /
    • 2005
  • 두부방사선규격사진은 작은 크기의 방사선원에서 방사상으로 방사선이 퍼져나감으로써 피사체의 확대와 왜곡이 불가피하다는 단점이 있다. 본 연구는 두 장의 방사선사진을 서로 직각으로 촬영한 후 방사선의 기하학적 성질을 이용하여 좌우 우각부간 폭경을 계산할 경우 실제 폭경의 산출이 가능한지 알아보고자 시행되었다. 성인 40명을 연구대상으로 하여 두부자세재현기를 이용하여 측모두부방사선사진과 정모두부방사선사진을 서로 직각으로 촬영한 후 측모사진과 정모사진에서의 확대율을 이용하여 실제 우각부 폭경을 산출한 다음 계측치 및 산출치를 3차원 CT영상에서의 계측치와 각각 비교 분석하였다. 연구결과 정모두부방사선사진에서 우각부 폭경은 작게는 7.92mm 크게는 11.31mm까지. 평균 9.10mm의 확대를 보였다. 측모 및 정모두부방사선사진을 이용하여 얻은 우각부 폭경 보정치를 3차원 CT영상에서 얻은 기준치와 비교한 결과 평균 0.14mm의 작은 오차를 보였으며 통계적으로 유의한 차이를 보이지 않아 측모 및 정모두부방사선사진 촬영 시 두부자세재현기를 이용하여 서로 직각으로 촬영할 경우 실제 우각부 폭경을 계산을 통해 산출할 수 있음을 보여주었다. 한편 이부편위량과 보정오차는 통계적으로 유의한 상관성을 보이지 않아 안면비대칭이 심한 경우에도 본 보정 방법이 유용하게 사용될 수 있음을 보여 주었다.

보상 알고리즘을 적용한 변압기 보호용 전류차동 계전방식 (Current Differential Relaying Algorithm for Power Transformer Protection Operating in Conjunction with a CT Compensating Algorithm)

  • 강용철;박종민;이미선;장성일;김용균;소순홍
    • 전기학회논문지
    • /
    • 제56권11호
    • /
    • pp.1873-1878
    • /
    • 2007
  • Current differential relays may maloperate during magnetic inrush and over-excitation because a significant differential current is produced. To prevent maloperation, the relays adopt some harmonic components included in the differential current. The harmonic restraints may increase the security of a relay but cause the operating time delay of a relay when an internal fault occurs. Moreover, the operating time delay is more increased if a current transformer (CT) is saturated. This paper describes a current differential relaying algorithm for power transformer protection with a compensating algorithm for the secondary current of a CT. The comparative study was conducted with and without the compensating algorithm. The performance of the proposed algorithm was investigated when the measurement CT (C400) and the protection CT (C400) are used. The proposed algorithm can compensate the distorted current of a CT and thus reduce the operating time delay of the relay significantly for an internal fault with CT saturation.

레이저 스페클을 이용한 CT 시험편의 변형장 측정 (Measurement of Deformation field in CT specimen using Laser speckle)

  • 전문창;강기주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.192-197
    • /
    • 2001
  • To obtain $A_2$ experimentally in the $J-A_2$ theory, deformation field on the lateral surface of a CT specimen was to be determined using Laser speckle method. The crack growth was measured using direct current potential drop method and most procedure of experimental and data reduction was performed according to ASTM Standard E1737-96. Laser speckle images during crack propagation were monitored by two CCD cameras to cancel the effect of rotation and translation of the specimen. An algorithm to pursue displacement of a point from each image was developed and successfully used to measure $A_2$ continuously as the crack tip was propagated. The effects of specimen thickness on J-R curve and $A_2$ were explored.

  • PDF

CT-based quantitative evaluation of radiation-induced lung fibrosis: a study of interobserver and intraobserver variations

  • Heo, Jaesung;Cho, Oyeon;Noh, O Kyu;O, Young-Taek;Chun, Mison;Kim, Mi-Hwa;Park, Hae-Jin
    • Radiation Oncology Journal
    • /
    • 제32권1호
    • /
    • pp.43-47
    • /
    • 2014
  • Purpose: The degree of radiation-induced lung fibrosis (RILF) can be measured quantitatively by fibrosis volume (VF) on chest computed tomography (CT) scan. The purpose of this study was to investigate the interobserver and intraobserver variability in CT-based measurement of VF. Materials and Methods: We selected 10 non-small cell lung cancer patients developed with RILF after postoperative radiation therapy (PORT) and delineated VF on the follow-up chest CT scanned at more than 6 months after radiotherapy. Three radiation oncologists independently delineated VF to investigate the interobserver variability. Three times of delineation of VF was performed by two radiation oncologists for the analysis of intraobserver variability. We analysed the concordance index (CI) and inter/intra-class correlation coefficient (ICC). Results: The median CI was 0.61 (range, 0.44 to 0.68) for interobserver variability and the median CIs for intraobserver variability were 0.69 (range, 0.65 to 0.79) and 0.61(range, 0.55 to 0.65) by two observers. The ICC for interobserver variability was 0.974 (p < 0.001) and ICCs for intraobserver variability were 0.996 (p < 0.001) and 0.991 (p < 0.001), respectively. Conclusion: CT-based measurement of VF with patients who received PORT was a highly consistent and reproducible quantitative method between and within observers.

치과 임플란트 수술 계획시 CT를 이용한 상악동 체적 및 치조골량 측정 (Measurement of maxillary sinus volume and available alveolar bone height using computed tomography)

  • 이재학;한원정;최영희;김은경
    • Imaging Science in Dentistry
    • /
    • 제33권1호
    • /
    • pp.35-41
    • /
    • 2003
  • Purpose: To aid in determining the volume of graft bone required before a maxillary sinus lift procedure and compare the alveolar bone height measurements taken by panoramic radiographs to those by CT images. Materials and Methods : Data obtained by both panoramic radiographs and CT examination of 25 patients were used in this study. Maxillary sinus volumes from the antral floor to heights of 5 mm, 10 mm, 15 mm, and 20 mm, were calculated. Alveolar bone height was measured on the panoramic images at each maxillary tooth site and corrected by magnification rate (PBH). Available bone height (ABH) and full bone height (FBH) was measured on reconstructed CT images. PBH was compared with ABH and FBH at the maxillary incisors, canines, premolars, and molars. Results: Volumes of the inferior portion of the sinuses were 0.55 ± 0041 ㎤ for 5 mm lifts, 2.11 ± 0.68 ㎤ for 10 mm, 4.26 ± 1.32 ㎤ for 15 mm, 6.95 ± 2.01 ㎤ for 20 mm. For the alveolar bone measurement, measurements by panoramic images were longer than available bone heights determined by CT images at the incisor and canine areas, and shorter than full bone heights on CT images at incisor, premolar, and molar areas (p<0.001). Conclusion: In bone grafting of the maxillary sinus floor, 0.96 ㎤ or more is required for a 5 mm-lift, 2.79 ㎤ or more for a 10 mm-lift, 5.58 ㎤ or more for a 15 mm-lift, and 8.96 ㎤ or more for a 20 mm-lift. Maxillary implant length determined using panoramic radiograph alone could result in underestimation or overestimation, according to the site involved.

  • PDF

안와파열골절 급성기의 CT영상을 이용한 계측학적인 연구 (Measurement Analytical Study of Computed Tomography of the Orbital Structure in Acute Blow-out Fracture)

  • 정성호;신승한;박승하;구상환
    • Archives of Plastic Surgery
    • /
    • 제34권1호
    • /
    • pp.44-51
    • /
    • 2007
  • Purpose: Blow-out fracture is one of the most common fractures in facial trauma. It is diagnosed by Computed Tomography(CT) scan, which is considered as the most effective diagnostic tool. Since, the Picture Archiving Communication System(PACS) has been provided recently to many hospitals, doctors are more familiar with imaging software of PACS. Because this software has many useful measuring tools, doctors can measure orbital structure easily and make a plan for treatment with its data. Therefore, authors intended to analyze the data of orbital structure measured with PACS imaging software and evaluate its usefulness. Methods: The charts and CT images of 100 patients, which were 50 patients with medial wall fracture and 50 patients with floor fracture, were reviewed. Patients were selected by pre-determined criteria and their CT images were measured with image software of PACS. 'Extraocular muscle thickness', 'Defect ratio'(ratio of defect area to normal area) and 'Globe position index' were measured and analyzed statistically. Results: The thickness of inferior rectus muscle and medial rectus muscle was simultaneously increased in acute-stage of blow-out fracture. The medial rectus muscle was more thickened in medial wall fracture and inferior rectus was more thickened in floor fracture, respectively. In acute blow-out fracture, globe position is exophthalmic rather than enophthalmic. Especially in floor fracture, numerical value summed up thickness of all extraocular muscle is correlated to the defect ratio and globe position index. Conclusion: Clinicians can decide globe position or presume defect ratio in inferior wall fracture by measurement of CT image in acute blow-out fracture using PACS.

Effectiveness of Computed Tomography for Blow-out Fracture

  • Rhee, Seung-Hyun;Kim, Tae-Seup;Song, Jae-Min;Shin, Sang-Hoon;Lee, Jae-Yeol
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제36권6호
    • /
    • pp.273-279
    • /
    • 2014
  • Purpose: This study assessed the association between eye symptoms (enophthalmos or diplopia) and site of damage, volume, deviated inferior rectus muscle (IRM) and type of fracture with computed tomography (CT). The intent is to anticipate the prognosis of orbital trauma at initial diagnosis. Methods: Forty-five patients were diagnosed with fractures of the inferior wall of one orbit. Fracture area, volume of displaced tissue, deviated IRM, and type of fracture were evaluated from coronal CT by one investigator. The association of those variables with the occurrence of eye symptoms (diplopia and enophthalmos) was assessed. Results: Of 45 patients, 27 were symptom-free (Group A) and 18 had symptoms (Group B) of enophthalmos and/or diplopia. In Group B, 12 had diplopia, one was enophthalmos, and five had both. By CT measurement, group A mean area was $192.6mm^2$ and the mean volume was $673.2mm^3$. Group B area was $316.2mm^2$ and volume was $1,710.6mm^3$. The volume was more influential on symptom occurrence. Each patient was categorized into four grades depending on the location of IRM. Symptom occurrence and higher grade were associated. Twenty-six patients had trap-door fracture (one side, attached to the fracture), and 19 had punched-out fracture (both sides detached). The punched-out fracture was more strongly associated with symptoms and had statistically significantly higher area and volume. Conclusion: In orbital trauma, measurement of fracture area and volume, evaluation of the deviated IRM and classification of the fracture type by coronal CT can effectively predict prognosis and surgical indication.

Energy Spectrum Measurement of High Power and High Energy (6 and 9 MeV) Pulsed X-ray Source for Industrial Use

  • Takagi, Hiroyuki;Murata, Isao
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.93-99
    • /
    • 2016
  • Background: Industrial X-ray CT system is normally applied to non-destructive testing (NDT) for industrial product made from metal. Furthermore there are some special CT systems, which have an ability to inspect nuclear fuel assemblies or rocket motors, using high power and high energy (more than 6 MeV) pulsed X-ray source. In these case, pulsed X-ray are produced by the electron linear accelerator, and a huge number of photons with a wide energy spectrum are produced within a very short period. Consequently, it is difficult to measure the X-ray energy spectrum for such accelerator-based X-ray sources using simple spectrometry. Due to this difficulty, unexpected images and artifacts which lead to incorrect density information and dimensions of specimens cannot be avoided in CT images. For getting highly precise CT images, it is important to know the precise energy spectrum of emitted X-rays. Materials and Methods: In order to realize it we investigated a new approach utilizing the Bayesian estimation method combined with an attenuation curve measurement using step shaped attenuation material. This method was validated by precise measurement of energy spectrum from a 1 MeV electron accelerator. In this study, to extend the applicable X-ray energy range we tried to measure energy spectra of X-ray sources from 6 and 9 MeV linear accelerators by using the recently developed method. Results and Discussion: In this study, an attenuation curves are measured by using a step-shaped attenuation materials of aluminum and steel individually, and the each X-ray spectrum is reconstructed from the measured attenuation curve by the spectrum type Bayesian estimation method. Conclusion: The obtained result shows good agreement with simulated spectra, and the presently developed technique is adaptable for high energy X-ray source more than 6 MeV.

건강검진에서 지방간 진단의 상복부초음파검사와 간 Hounsfield Units 측정값과의 정확성 분석 (Fatty Liver Diagnostics from Medical Examination to Analyze the Accuracy Between the Abdominal Ultrasonography and Liver Hounsfield Units)

  • 오왕균;김상현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권2호
    • /
    • pp.229-235
    • /
    • 2017
  • 상복부초음파검사에서 간실질의 에코 음영증가와 불명확한 혈관경계 등으로 지방간을 진단하는데, 여러 연구들에 의하면 지방간 진단에 84~95%의 특이도와 60~90%의 민감도를 가지나 결과가 검사자에 의존적이어서 차이가 있을 수 있고 지방의 침윤 상태의 정량적인 측정이 불가능하다. 건강검진의 상복부초음파검사와 흉부 전산화단층촬영(computed tomography; CT) 검사를 같은 날에 시행한 수검자중 초음파검사에서 지방간을 진단 받은 환자의 흉부 전산화단층촬영 영상에서 간(Liver) Hounsfield Units(HU)를 측정하여 지방간 진단의 정확성을 연관분석 하고자 하였다. 연구대상 수검자 720명 중 가정의학과 전문의에게 검사를 받고 지방간 판정을 받은 자는 448명으로 62.2%였다. 지방간 판정자의 CT영상에서 간 HU를 측정한 결과 40 HU 이하의 측정값은 720명 중 175명으로 24.3%이며, 초음파에서 진단 받은 448명에 175명 중 173명이 포함되어 98.9%가 일치하였다. 이는 지방간을 초음파로 진단 시 검사자의 주관적 경험과 능력이 병변을 진단하는데 크게 영향을 미친 것으로 생각되며 검진 CT검사에서 간 HU를 측정하여 40 HU 이하는 영상저장을 통하여 지방간 진단 시 참고자료로 활용될 수 있을 것으로 사료된다.