• Title/Summary/Keyword: Measurement Angle

검색결과 2,166건 처리시간 0.033초

Feasibility study on the contact angle measurement by laser beam projection

  • Ahn, Seon-Hoon;Kim, Seong-Hun;Shin, Kyung-In;IM, Seung-Soon
    • 한국섬유공학회:학술대회논문집
    • /
    • 한국섬유공학회 2003년도 The Korea-Japan Joint Symposium
    • /
    • pp.103-103
    • /
    • 2003
  • A newly developed contact angle measurement instrument by laser beam projection allows for rapid and direct determination of contact angles. From the result of comparative experiment and questionnaire, the laser contact angle.

  • PDF

Image Processing에 의한 MEMS소자의 미세한 각도측정 (Angle Measurement of MEMS Devices Image Processing)

  • 고진환;김호성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2198-2200
    • /
    • 2000
  • This paper reports on the measurement of angle between micro mirror and substrate in. the Micro Optical Cross Connect(MOXC). MOXC consists of beam collimators and $N{\times}N$ micro mirrors that are fabricated by using MEMS technology. Using subpixel level image processing, it is possible to measure the angle with the resolution of 0.27$^{\circ}$.

  • PDF

빔폭을 고려한 선형간섭계 안테나 설계 (Design of Linear Interferometer Antenna Regarding Beamwidth)

  • 최익환
    • 한국전자파학회논문지
    • /
    • 제27권8호
    • /
    • pp.693-700
    • /
    • 2016
  • 본 논문에서는 구성 안테나의 수신 영역을 빔 폭 내로 한정하고, 각도 측정 모호성이 없는 선형간섭계 안테나 설계를 위한 수식을 제안하였다. 수식을 이용하여 구성 안테나 간격과 각도 모호성과의 관계를 설명하고, 선형간섭계 설계를 위한 운용주파수, 각도 정확도, 빔폭, 측정 확률을 계산하여 고각과 방위각 측정을 위한 총 5개의 구성 안테나로 이루어진 선형간섭계 안테나를 설계, 제작, 측정한 결과를 제시하였다. 각도 측정 정확도는 방위각, 고각 각각 $0.01^{\circ}$, $0.016^{\circ}$ 이며, 계측 값의 99 % 이상이 모호성 없이 정확히 측정되었다. 이로써 제안한 수식과 설계 과정이 유효함을 확인할 수 있었다.

Enhancement of Tracking Performance of Laser Tracking System for Measuring Position Accuracy of Robots

  • Hwang, Sung-Ho;Choi, Gyeong-Rak;Lee, Ho-Gil;Shon, Woong-Hee;Kim, Jin-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.61.5-61
    • /
    • 2001
  • The laser tracking system(LTS) presents the most promising technique for dynamic position measurement of industrial robots. This system combine the advantage of high accuracy with a contactless measurement technique. It is the measurement system of position in three dimensions using distance data obtained by laser interferometer and real time angle by tracking mirror assembly. After measuring the tracking error of the beam projected on the center of retroreflector in robot end effector, this system tracks the end effector continuously by adjusting tracking mirror angle to minimize this error ...

  • PDF

Requirements in terms of measurement area for viewing angle optical characterization of liquid crystal displays

  • Leroux, Thierry;Bignon, Thibault;Boher, Pierre
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.602-605
    • /
    • 2005
  • In this paper, we present a model to calculate the influence of the measurement spot diameter MSD on the viewing angle measurements using a conoscopic instrument. This model is verified experimentally using an EZContrast instrument and the requirements for next generation of displays are presented. We show that last generation of EZContrast XL88W and L80W allowing measurement spot diameter up to 6mm can fulfill the requirements for all the FPD generations up to 80 inches diagonal.

  • PDF

한국인 사체에서의 정상 종골의 실측: 예비보고 (Measurement of Normal Calcaneus in Korean Cadavers: A Preliminary Report)

  • 김정한;곽희철;김전교;정양환
    • 대한족부족관절학회지
    • /
    • 제18권1호
    • /
    • pp.14-18
    • /
    • 2014
  • Purpose: The purpose of this report is to evaluate the measured values of normal Korean calcaneus by conduct of a cadaveric study. Materials and Methods: A total of 42 calcanei were obtained from Korean cadavers. A digital goniometer was used for measurement of B$\ddot{o}$hler's angle, Gissane angle, posterior facet articular inclination angle, and Fowler-Philip angle of calcaneus. A vernier caliper was used for measurement of the maximal antero-posterior length, maximal transverse width, and maximal height of calcaneus. Results: The average B$\ddot{o}$hler's angle, Gissane angle, posterior facet articular inclination angle, and Fowler-Philip angle was $32.3^{\circ}{\pm}5.0^{\circ}$, $114.4^{\circ}{\pm}8.2^{\circ}$, $61.2^{\circ}{\pm}4.4^{\circ}$, and $60.3^{\circ}{\pm}7.6^{\circ}$. The average maximal antero-posterior length, maximal transverse width, and maximal height of calcaneus was $74.2{\pm}3.0mm$, $43.0{\pm}4.0mm$, and $42.5{\pm}3.0mm$. Conclusion: The measured values of normal Korean calcaneus were lower than the values reported in the international literature. Therefore, development of appropriate instruments reflecting the anatomical characteristics of Koreans will be needed.

Improved Angle-of-View Measurement Method for Display Devices

  • Lee, Eun-Jung;Chong, Jong-Ho;Yang, Sun-A;Lee, Hun-Jung;Shin, Mi-Ok;Kim, Su-Young;Choi, Dong-Wook;Lee, Seung-Bae;Lee, Han-Yong;Berkeley, Brian H.
    • Journal of Information Display
    • /
    • 제11권1호
    • /
    • pp.17-20
    • /
    • 2010
  • With the increasing demand for a better FPD image quality, better evaluation metrics and advanced display quality measurement methods are required to meet these needs. There are many measurement methods for evaluating the viewing angle of various display devices, but these methods, which include luminance drop, color shift, and contrast ratio decrease, are imperfect considering that human perception does not completely correlate to them. In this paper, a new method of measuring the perceptual angle of FPDs is proposed, considering human visual perception, which uses the color space of the color appearance model.

Improved Method for Angle-of-View Measurement of Display Devices

  • Lee, Eun-Jung;Chong, Jong-Ho;Yang, Sun-A;Lee, Hun-Jung;Shin, Mi-Ok;Kim, Su-Young;Choi, Dong-Wook;Lee, Seung-Bae;Lee, Han-Yong;Berkeley, Brian H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.979-982
    • /
    • 2009
  • With increasing demand for better FPD image quality, better evaluation metrics and advanced display quality measurement methods are required to meet these needs. There are many measurement methods to evaluate viewing angle of the various different display devices. However, these methods, which include luminance drop, color shift, and contrast ratio decrease, are imperfect considering that human perception does not completely correlate to these methods. In this paper, we propose a new method for measuring perceptual angle of FPDs considering human visual perception, which uses color space of the color appearance model.

  • PDF

The Iron loss Estimation of IPMSM According to Current Phase Angle

  • Cho, Gyu-Won;Kim, Dong-Yeong;Kim, Gyu-Tak
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1345-1351
    • /
    • 2013
  • Variable iron loss as function of current phase angle of Interior Permanent Magnet Synchronous Motor(IPMSM) was calculated through Curve Fitting Method(CFM). Also, a magnetic flux density distribution of iron core according to current phase angle was analyzed, and an iron loss calculation was performed including harmonic distortion. The experiment was performed by production of non-magnetizing model for the separation of mechanical loss, and the iron loss was calculated by the measurement of input using power analyzer and output power using dynamometer. Some error was generated between experimental results and calculation value, but an iron loss diminution according to current phase angle followed a same pattern. So, errors were generated by measurement, vibration, noise, harmonic distortion loss, etc.

음향파워 측정 시 오차에 대한 고찰 (A Study on the Errors at the Measurement of Sound Power)

  • 나혜중;임병덕
    • 한국소음진동공학회논문집
    • /
    • 제22권10호
    • /
    • pp.917-924
    • /
    • 2012
  • Noise power of large machineries, such as textile looms, winders, and twisting machines, is often measured in a reverberant space because they cannot be installed and operated in an anechoic chamber due to their size, weight, and operating conditions. Factors affecting the measurement error of an in-situ noise power measurement include the nonuniform reverberation time and the direction of sound intensity vector which is usually regarded as normal to the measurement surface. In this study errors due to these factors are estimated with the aid of numerical simulation based on the ray-tracing technique. The averaging of reverberation times measured at several points on the measurement surface is suggested to reduce the errors from nonuniform absorption. Also the direction cosine of each surface element is taken into account, which as a whole is represented as a solid angle of the measurement surface.