• Title/Summary/Keyword: Measurement Angle

Search Result 2,166, Processing Time 0.03 seconds

3D Depth Measurement System based on Parameter Calibration of the Mu1ti-Sensors (실거리 파라미터 교정식 복합센서 기반 3차원 거리측정 시스템)

  • Kim, Jong-Man;Kim, Won-Sop;Hwang, Jong-Sun;Kim, Yeong-Min
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.125-129
    • /
    • 2006
  • The analysis of the depth measurement system with multi-sensors (laser, camera, mirror) has been done and the parameter calibration technique has been proposed. In the proposed depth measurement system, the laser beam is reflected to the object by the rotating mirror and again the position of the laser beam is observed through the same mirror by the camera. The depth of the object pointed by the laser beam is computed depending on the pixel position on the CCD. There involved several number of internal and external parameters such as inter-pixel distance, focal length, position and orientation of the system components in the depth measurement error. In this paper, it is shown through the error sensitivity analysis of the parameters that the most important parameters in the sense of error sources are the angle of the laser beam and the inter pixel distance.

  • PDF

Newly Designed HRTF Measurement System and its Analysis (머리전달함수 측정시스템의 개발과 분석)

  • Lee, Yun-Jae;Park, Young-Jin;Park, Youn-Sik
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.2
    • /
    • pp.202-205
    • /
    • 2010
  • When we render 3D sound images using headphones or speakers, the main key of this technology is the Head-related transfer function (HRTF) database. Even though there are various HRTF databases, they have some drawbacks such as detrimental effects caused by imperfect measuring environment and insufficient measurement points. Moreover there is no database with Korean subjects. We are planning to develop the HRTF database for Korean. As a first step to establish the HRTF database aimed at Korean, the new HRTF measurement system with minimized aforementioned drawbacks is designed. In this paper, the newly designed HRTF measurement system is introduced and the overall effects caused by the diffraction of the apparatus, especially the headrest and backrest of the chair, are analyzed. The backrest of the chair does not distort the HRTFs significantly while the headrest makes significant distortion on the HRTFs and it could have significant effects on directional perception. We determined acceptable head rotation angle and head position of the subject for accurate HRTF measurement based on the experiments with B&K HATS. We conclude that the 3 degrees of the head rotation and the 1.5cm front/back/left/right shift of the head do not distort the HRTFs significantly.

Development of Material Deformation Measurement System using Machine Vision (머신 비전을 활용한 재료 변형 측정 기술 개발)

  • E. B. Mok;W. J. Chung;C. W. Lee
    • Transactions of Materials Processing
    • /
    • v.32 no.1
    • /
    • pp.20-27
    • /
    • 2023
  • In this study, the deformation of materials was measured using the video and tracking API of OpenCV. Circular markers attached to the material were selected the region of interests (ROIs). The position of the marker was measured from the area center of the circular marker. The position and displacement of the center point was measured along the image frames. For the verification, tensile tests were conducted. In the tensile test, four circular markers were attached along the longitudinal and transverse directions. The strain was calculated using the distance between markers both in the longitudinal and transverse direction. As a result, the stress-strain curve obtained using machine vision is compared to the stress-strain curve obtained from the DIC results. RMSE values of the strain from the machine vision and DIC were less than 0.005. In addition, as a measurement example, a bending angle and springback measurement according to bending deformation, and a moving position measurement of a punch, a blank holder, and a die by time change were performed. Using the proposed method, the deformation and displacement of the materials were measured precisely and easily.

Subtalar Distraction Bone Block Arthrodesis (Five Cases) (거골하 신연 골편 관절 유합술)

  • Yoo, Chong-Il;Eun, Il-Soo;Jung, Yong-Wook
    • Journal of Korean Foot and Ankle Society
    • /
    • v.8 no.1
    • /
    • pp.101-106
    • /
    • 2004
  • Purpose: To determine the efficacy of the SDBBA (Subtalar distraction bone block arthrodesis) procedure on patients with late complication of intra-articular calcaneal fractures including subtalar joint arthritis and anterior ankle impingement syndrome. Materials and Methods: Five cases in which the SDBBA procedure was implemented were followed for more than one year. All five patients were male with an average age of 56. Clinically, the American Orthopedic Foot and Ankle Society (AOFAS) ankle-hindfoot score and the pain score were assessed. Radiographically, the talocalcaneal height and the talar inclination angle were determined. Results: All five patients achieved subtalar joint fusion. The average pre-operative AOFAS score was 22.8 scores (range, 8-32 scores). At last follow-up, these scores improved to an average of 72.4 scores (range, 64-82 scores). The average pre-operative pain score was 8.2 scores (range, 7-10 scores). At last follow-up, these scores improved to an average of 13.2 (range, 12-15 scores). The average pre-operative talocalcaneal height was 72.8 mm (range, 70-77 mm), average post-operative talocalcaneal height improved to 79.8 mm (range, 78-84 mm). At final follow-up, these measurement was slightly decreased to average 78.6 mm (range, 74-83 mm). The average pre-operative talar inclination angle was 13.2 degrees (range, 12-15 degrees), average post-operative talar inclination angle improvedto 19.2 degrees (range, 15-24 degrees). At final follow-up, these measurement was slightly decreased to average 18.6 degrees (range, 12-24 degrees). Four patients achieved successful outcomes. One patient developed a wound infection with subsequent sural neuropathy as well as collapse of the bone graft. Conclusion: This study shows that the SDBBA procedure successfully restores the talocalcaneal height and tibio-talar relationship. This procedure is useful in surgically managed patients with talo-calcaneal height loss and anterior ankle impingement syndrome due to the late complications of calcaneal intra-articular fractures.

  • PDF

Optimal design of a flexure hinge-based XY AFM scanner for minimizing Abbe errors and the evaluation of pitch measuring uncertainty of a nano-accuracy AFM system (XY 스캐너의 아베 오차 최소화를 위한 최적 설계 및 나노 정밀도의 원자 현미경 피치 측정 불확도 평가)

  • Kim Dong-Min;Lee Dong-Yeon;Gweon Dae-Gab
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.6 s.183
    • /
    • pp.96-103
    • /
    • 2006
  • To establish of standard technique of nano-length measurement in 2D plane, new AFM system has been designed. In the long range (about several tens of ${\mu}m$), measurement uncertainty is dominantly affected by the Abbe error of XY scanning stage. No linear stage is perfectly straight; in other words, every scanning stage is subject to tilting, pitch and yaw motion. In this paper, an AFM system with minimum offset of XY sensing is designed. And XY scanning stage is designed to minimize rotation angle because Abbe errors occur through the multiply of offset and rotation angle. To minimize the rotation angle optimal design has performed by maximizing the stiffness ratio of motion direction to the parasitic motion direction of each stage. This paper describes the design scheme of full AFM system, especially about XY stage. Full range of fabricated XY scanner is $100{\mu}m\times100{\mu}m$. And tilting, pitch and yaw motion are measured by autocollimator to evaluate the performance of XY stage. As a result, XY scanner can have good performance. Using this AFM system, 3um pitch specimen was measured. The uncertainty of total system has been evaluated. X and Y direction performance is different. X-direction measuring performance is better. So to evaluate only ID pitch length, X-direction scanning is preferable. Its expanded uncertainty(k=2) is $\sqrt{(3.96)^2+(4.10\times10^{-5}{\times}p)^2}$ measured length in nm.

Electrocardiogram-Gated Multi-Angle Doppler Optical Coherence Tomography (심전도 게이트를 사용한 다관점 도플러 광 단층촬영법)

  • Ahn, Yeh-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.7
    • /
    • pp.685-691
    • /
    • 2011
  • The aim of this study is to point out the uniqueness of Doppler optical coherence tomography (DOCT) for use in a probe station for (in vivo) visualization of microscale flow and structure and to maximize the effectiveness of DOCT by overcoming its limitations. Conventional DOCT produces images of only one of the velocity components that is parallel to the incident light. In this study, a multi-angle DOCT to quantify a velocity vector field is proposed; this is an extension from a velocity scalar field to a vector field. Quantifying an instantaneous three-dimensional velocity field in a pulsating flow is another challenge because of its limited frame rate. The in-vivo pulsating blood flow is measured by using an electrocardiogram-gated multi-angle DOCT in a hamster cheek pouch model. It is shown that the aliasing problem caused by a relatively low frame rate is resolved by using this method of measurement.

Surface pressure measurement on a wing of SWIM by using PSP (PSP를 이용한 항공기 형상 모형 날개 표면 압력 측정)

  • Jung, Hye-Jin;Kwon, Kijung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.4
    • /
    • pp.337-345
    • /
    • 2008
  • this study, three dimensional surface pressure distributions of SWIM whose main wing has NACA4412 airfoil with NACA0012 flaps were experimentally measured by pressure sensitive paint. Surface pressures on suction and pressure sides of the wing were measured by changing an angle of attack at a Reynolds number of 3.1x105 in KARI 1m subsonic wind tunnel. The experimental results showed that as an angle of attack increases minimum pressure region on a suction side moved from the wing root to the tip and low pressure region around trailing edge of the wing tip which causes wing tip vortex was observed. Although low pressure region at the tip still observed at an angle of attack 15 deg., other area on a suction side showed flat pressure distribution in a span-wise direction. It was also observed that the mean value of pressure coefficients was about 0.077 through a comparison between PSP and pressure taps at the same test conditions.

The Posture Estimation of Mobile Robots Using Sensor Data Fusion Algorithm (센서 데이터 융합을 이용한 이동 로보트의 자세 추정)

  • 이상룡;배준영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.11
    • /
    • pp.2021-2032
    • /
    • 1992
  • A redundant sensor system, which consists of two incremental encoders and a gyro sensor, has been proposed for the estimation of the posture of mobile robots. A hardware system was built for estimating the heading angle change of the mobile robot from outputs of the gyro sensor. The proposed hardware system of the gyro sensor produced an accurate estimate for the heading angle change of the robot. A sensor data fusion algorithm has been developed to find the optimal estimates of the heading angle change based on the stochastic measurement equations of our readundant sensor system. The maximum likelihood estimation method is applied to combine the noisy measurement data from both encoders and gyro sensor. The proposed fusion algorithm demonstrated a satisfactory performance, showing significantly reduced estimation error compared to the conventional method, in various navigation experiments.

Reliability and Convergent Validity of Standing Posture Measurement Using a Mobile Application in Forward Head Posture (전방머리자세 성인을 대상으로 모바일 어플리케이션을 이용한 자세정렬 측정의 신뢰도 및 수렴 타당도 연구)

  • Kang, Hyojeong;Kim, Minkyu;Yang, Hoesong;Lee, Wanhee
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.3
    • /
    • pp.173-180
    • /
    • 2020
  • Purpose : The aim of this study was to assess the intra- and inter-rater reliability and validity of measurements of head, neck, and pelvis posture using a mobile application in subjects with forward head posture. Methods : Forty-eight volunteers (22 men, 26 women) participated in this study. Two raters independently examined whole body picture images in a lateral standing posture with arms crossed using a CA-Smart Posture Reminder (CA-SPR), and a rater took and calculated posture images twice to assess reliability. We measured five parameters: craniovertebral angle 1 (CVA1), anterior shoulder translation (AST), pelvic tilt (PT), knee angle (KA), and ankle angle (AA) in the subject's sagittal plane using CA-SPR. We examined whole spine X-ray images in the same position to assess validity. We measured four variables in the subjects: CVA2, translation distance (AHT), anterior pelvic plane (APP), and sacral slope (SS). The intra- and inter-rater reliability were calculated using the intraclass correlation coefficient (ICC). Convergent validity was calculated using Pearson's correlation coefficient. Results : The intra-rater reliability (ICC=.889 -.989) and inter-rater reliability (ICC=.800 -.980) were excellent for all variables measured using CA-SPR. The variables measured using CA-SPR and X-ray were significantly positively correlated (r=.623, p<.01). However, the correlation of the variables in the pelvis was not statistically significant. Conclusion : This study shows that a mobile application (CA-SPR) is a useful tool for measuring head and neck posture in subjects with forward head posture. However, further study is needed to measure pelvic variables when using a mobile application.

Study on Evaluation Method of Flow Characteristics in Steady Flow Bench(5)-Effect of Evaluation Position (정상유동 장치에서 유동 특성 평가 방법에 대한 연구(5) - 평가위치의 영향)

  • Cho, Siehyung;Ohm, Inyong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.25 no.2
    • /
    • pp.179-189
    • /
    • 2017
  • This paper is the fifth investigation on the methods of evaluating flow characteristics in a steady flow bench. In previous studies, several assumptions used in the steady flow bench were examined and it was concluded that the assumption of the solid rotation may lead to serious problems. In addition, though the velocity profiles were improved as the measuring position went downstream, the distributions were far from ideal regardless of the valve angle and evaluation position. The eccentricities were also not sufficiently small to disregard the effect on impulse swirl meter (ISM) measurement. Therefore, the effect of these distribution and eccentricity changes according to the positions needs to be analyzed to discuss the method of flow characteristics estimation. In this context, the effects of evaluation position on the steady flow characteristics were studied. For this purpose, the swirl coefficient and swirl ratio were assessed and compared via measurement of the conventional ISM and calculation based on the velocity by particle image velocimetry(PIV) from 1.75B, 1.75 times bore position apart from the cylinder head, to the 6.00B position. The results show that the swirl coefficients by ISM strictly decrease and the curves as a function of the valve lift become smooth and linear as the measuring position goes downstream. However, the values through the calculation based on the PIV are higher at the farther position due to the approach of the tangential velocity profile to ideal. In addition, there exists an offset effect between the velocity distribution and eccentricity in the low valve lift range when the coefficients are estimated based on the swirl center. Finally, the curve of the swirl ratio by ISM and by PIV evaluation as a function the measuring position intersect around 5.00B plane except at $26^{\circ}$ valve angle.