• Title/Summary/Keyword: Measurement Angle

Search Result 2,166, Processing Time 0.031 seconds

Measurement and Analysis of Liquid Film Thickness of Pressure-Swirl Spray for Direct-Injection Gasoline-Engines (직접분사식 가솔린엔진용 고압 스월분무의 액막두께 측정 및 해석)

  • Moon, Seok-Su;Abo-Serie, Essam;Oh, Hee-Chang;Bae, Choong-Sik
    • Journal of ILASS-Korea
    • /
    • v.12 no.4
    • /
    • pp.211-219
    • /
    • 2007
  • The liquid film thickness inside a pressure-swirl nozzle was measured, and then the measured liquid film thickness was compared with the results from previous empirical equations. The liquid film inside the nozzle was visualized using extended transparent nozzles and a microscopic imaging system, and then the measurement error was evaluated using optical geometry analysis. The high injection pressures up to 7MPa were adopted to simulate the injection conditions of the direct-injection spark-ignition engines. The totally different two injectors with different fuels, nozzle lengths, nozzle diameters and swirlers were utilized to obtain the comprehensive equations. The results showed that the liquid film thickness very slightly decreased at high injection pressures and the empirical equations overestimated the effect of injection pressure. Most of empirical equations did not include the effect of nozzle length and swirler angle, although it caused significant change in liquid film thickness. A new empirical equation was suggested based on the experimental results with the effects of fuel properties, injection pressure, nozzle diameter, nozzle length and swirler angle.

  • PDF

The Characteristics of Wiper Blade Rubber with Surface Treatments (와이퍼 블레이드 고무의 표면 처리에 따른 특성)

  • Rho, Seung-Baik;Lim, Mi-Ae;Park, Jin-Kyu;Son, Jeon-Ik
    • Elastomers and Composites
    • /
    • v.33 no.1
    • /
    • pp.27-36
    • /
    • 1998
  • The surface of wiper blade(W/B) rubber was chlorinated by chemical treatment method using the hydrochloric acid(HCI) and sodium hypochlorite(NaOCl). From the results of contact angle measurement, friction coefficient measurement, and ATR-IR spectra, the surface characteristics of chlorinated W/B rubber with time of chlorination were studied. Contact angles for W/B rubber with increasing time of chlorination and chlorine concentration were measured for the water and ethylene glycol. From the results, contact angle fell rapidly with increasing time of chlorination and chlorine concentration, reaching a constant value after about 10min. And the wettability of W/B rubber surface by means of chlorination has been improved. For an unchlorinated W/B rubber, the friction coefficient with time of chlorination decreased from 1.27 to 0.20~0.23 on full chlorination. As the results it was considered that abrasion resistance of W/B rubber surface has been also improved. The values of pH and $Cl^-$ ion concentration in a chlorine treatment solution decreased as the extent of chlorination of W/B rubber surface increased. From the results of ATR-IR spectra, it was observed that C=C double band of W/B rubber surface transformed into C-Cl band, but quantitative determination of the extent of chlorination was not feasible because of the complexity of chlorination reactions.

  • PDF

Development of the Precise Multi-Position Alignment Method using a Pitch Motion (피치운동을 이용한 정밀 다위치 정렬기법 개발)

  • Lee, Jung-Shin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.708-715
    • /
    • 2010
  • In Strapdown Inertial Navigation System, alignment accuracy is the most important factor to determine the performance of navigation. However by an existing self-alignment method, it takes a long time to acquire the alignment accuracy that we want. So, to attain the desired alignment accuracy in as little as $\bigcirc$ minutes, we have developed the precise multi-position alignment method. In this paper, it is proposed a inertial measurement matching transfer alignment method among alignment methods to minimize the alignment error in a short time. It is based on a mixed velocity-DCM matching method be suitable to the operating environment of vertical launching system. The compensation methods to reduce misalign error, especially azimuth angle error incurred by measurement time-delay error and body flexure error are analyzed and evaluated with simulation. This simulation results are finally confirmed by experimentations using FMS(Flight Motion Simulator) in Lab and the integration test to follow the fire control mission.

An Experimental Study on Angled Injection and Droplet Size Characteristics of Liquid Jets in Subsonic Crossflow

  • Kim, Min-Ki;Song, Jin-Kwan;Hwang, Jeong-Jae;Yoon, Young-Bin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.486-491
    • /
    • 2008
  • The spray characteristics and drop size measurements have been experimentally studied in liquid jets injected into subsonic crossflow. With water as fuel injection velocity, injection angle and atomizer internal flows were varied to provide of jet operation conditions. The injector internal flow was classified as three modes such as a non-cavitation flow, cavitation, and hydraulic flip flows. Pulsed Shadowgraph Photography measurement was used to determine the spatial distribution of the spray droplet diameter in a subsonic crossflow of air. And this study also obtains the SMD(Sauter Mean Diameters) distribution by using PLLIF(Planar Liquid Laser Induced Fluorescence) technique. The objectives of this research are getting a droplet distribution and drop size measurement of each condition and compare with the other flows effect. As the result, This research have been showed the droplet size were spatially dependent on air-stream velocity, fuel injection velocity, injection angle effects and normalized distance from the injector exit length.(x/d, y/d)There are also different droplet size characteristics between cavitation, hydraulic flip and the non-cavitation flows.

  • PDF

Real-time Measurement of Full Field Retardation Near Quarter Wavelength

  • Liu, Longhai;Zeng, Aijun;Yuan, Qiao;Zhu, Linglin;Fang, Ruifang;Huang, Huijie
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.457-461
    • /
    • 2012
  • A real-time method to measure full field retardation near quarter wavelength is proposed. The circularly polarized beam passes through a sample with a large aperture. The measuring beam then goes through a quarter-wave plate and is then split by a Wollaston prism. An image with two sub-images is then detected by a high-speed image sensor. The full field retardation near quarter wavelength can be obtained in real time by processing the image. The measured retardation is independent of the fast axis angle of the sample and the fluctuation of the initial intensity. In experiments, a wedge waveplate is measured with different fast axis angle and initial intensity, and the full field retardations are acquired. The maximum and standard deviation of the full field retardation is $1.5^{\circ}$ and $0.4^{\circ}$. The validity of the method is verified.

Visual Measurement of Rotational Displacements by Using Two Different Moire Fringes Simultaneously Generated by Repeated Sinusoidal Gratings (반복사인격자에서 동시에 생기는 두 가지 무아레 무늬를 이용한 회전변위의 가시적 측정)

  • Jeong, Youn-Hong;Oh, Jeong-Hyo;Jo, Jae-Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.4
    • /
    • pp.302-309
    • /
    • 2008
  • We present the precise visual measurement method of rotational displacements using two different moire fringes simultaneously generated by repeated sinusoidal gratings. We investigate the variation of moire fringes depending on rotational displacements through computer simulation and experiment using a rotator in detail. The moire fringes are composed of the wide linear fringe part with a long period and the narrow linear fringe part with a short period. These parts are superior to the angle detection of more than 12 degrees and less than 12 degree, respectively. Additionally, the method can be visually used in the determination of the rotational direction by observing the moire fringe's direction.

A Study on the Improvement of Smoke Probe Performance in Diesel Vehicles Using Korean 147 Test Method (한국형 147검사 방법을 이용한 디젤자동차의 매연프로브 성능 향상 연구)

  • Kim, Jae-Yeol;Chae, Il-Seok;Kim, Sang yu;Yang, Dong Hee
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.7
    • /
    • pp.25-32
    • /
    • 2021
  • In the previous study, a study was conducted to improve the exhaust gas intake efficiency by improving the existing soot measurement probe in the shape and angle of the exhaust port. As a result, it can be seen that the smoke measurement performance according to the shape and angle is improved. In previous studies, the performance of the soot probe was not confirmed for the Korean KD 147 mode, which has a low suction flow rate and a long inspection time. So, we would like to confirm the improvement of the smoke probe performance of the Korean KD 147 mode, which is close to the actual driving conditions. The probe used in this study is another type of probe, and has a circular ring shape instead of a rib and variable center position unit, so the probe center hole is located close to the center of the exhaust pipe.

A Study of the Thickness Characteristics of the Liquid Sheet Formed by an Impinging Jet onto a Plate (평판 충돌 제트로 생성되는 액막의 두께 분포 특성 연구)

  • Kim, M.S.;Oh, J.H.;Jeong, H.M.;Kang, B.S.
    • Journal of ILASS-Korea
    • /
    • v.27 no.2
    • /
    • pp.77-83
    • /
    • 2022
  • In this study, the thickness of the liquid sheet formed by a low speed impinging jet onto a flat plate was measured by the direct contact method. The spatial distribution characteristics of the sheet thickness in the radial and circumferential directions, and the effects of jet velocity and liquid viscosity were analyzed. The measurement results were compared with the theoretical predictions. The wavy surface was observed in the case of low viscosity water, but not in the high viscosity aqueous glycerol solutions. The sheet thickness increased as the circumferential angle increased or the distance from the impinging point increased, but the thickness decreased as the circumferential angle increased around the impinging point. As the jet speed increased, the sheet thickness decreased, and the sheet thickness increased as the liquid viscosity increased. Comparison with the theoretical predictions showed that the measurement results agreed well in the case of low viscosity water or high viscosity liquids around the impinging point. The distribution characteristics of the sheet thickness can provide useful means for prediction of spray characteristics in splash plate injectors.

Numerical analysis of the venturi flowmeter in the liquid lead-bismuth eutectic circuit after long-term operation

  • Zhichao Zhang;Rafael Macian-Juan;Xiang Wang
    • Nuclear Engineering and Technology
    • /
    • v.56 no.3
    • /
    • pp.1081-1090
    • /
    • 2024
  • The liquid Lead-bismuth eutectic is used as the coolant for Gen-IV reactor concepts. However, due to its strong corrosive and high operating temperature, it is difficult to accurately measure the flow rate in long-term operating conditions. Venturi flowmeter is a simple structured flowmeter, which plays a very important role in the flow measurement of high-temperature liquid metals, especially since the existing flowmeters are difficult to be competent. It has the advantages of easy maintenance and stable operation. Therefore, it is necessary to study the operating conditions of the venturi flowmeter under high-temperature conditions. This work performs a series of simulations of the fluid-solid interaction between the flow liquid metal and venturi flowmeter with COMSOL software, including the dimensional sensitivity analysis of the venturi flowmeter to explore the most suitable structure and parameters for liquid heavy metal, the sensitivity analysis of the geometric parameters of the venturi tube on the varying conditions. It shows that when the contraction angle of the venturi flowmeter is 33°, the diffusion angle is 13°, the diameter of the throat is 8 mm, and the temperature of the lead-bismuth eutectic is 733.15 K, it is most suitable for the measurement in the lead-bismuth circuit.

The Effect of Second Toe Valgus on Correction Loss of Hallux Valgus Angle in Surgical Treatment (무지외반증 수술에서 제 2족지의 외반 정도가 무지 외반각 교정소실에 미치는 영향)

  • Kang, Suk Woong;Song, Moo Ho;Kim, Yeong Joon;Oh, Young Kwang;Yoo, Seong Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.21 no.4
    • /
    • pp.135-138
    • /
    • 2017
  • Purpose: The purpose of this study is to determine the correlation between the correction loss of hallux valgus angle and the severity of valgus angle of the second toe. Materials and Methods: We selected 312 cases from 268 surgical patients with hallux valgus deformity receiving distal chevron osteotomy. For a radiological evaluation, we analyzed the changes in the hallux valgus angles, first to second intermetatarsal angles, and valgus angle of the second toe post index operations. All patients were women; the mean age was 46 years. The mean follow-up period was 17 months. Results: The mean hallux valgus angle was $33.6^{\circ}$ preoperatively (range, $25.7^{\circ}{\sim}44.8^{\circ}$), $13.1^{\circ}$ (range, $8.4^{\circ}{\sim}16.4^{\circ}$) after 4 weeks of postoperative period, and $17.1^{\circ}$ (range, $9.4^{\circ}{\sim}28.5^{\circ}$) at their final follow-up. The mean valgus angle of the second toe was $8.4^{\circ}$ preoperatively (range, $2.0^{\circ}{\sim}25.8^{\circ}$) and $8.3^{\circ}$ (range, $1.7^{\circ}{\sim}24.9^{\circ}$) at the final follow-up. Preoperatively, there was a positive correlation between the valgus angle of the second toe and hallux valgus angle (r=0.747, p=0.001). The correction loss of hallux valgus angle had a significant correlation with the severity of valgus angle of the second toe (r=0.802, p=0.001). Conclusion: The existence of the second toe valgus deformity may present itself as a cause of correction loss of hallux valgus angle. The preoperative measurement of the second toe valgus angle may be a good predictor of correction loss; therefore, thorough preoperative warning on the possibility of correction loss should be conducted to maximize patient satisfaction after the procedure.