• Title/Summary/Keyword: Measurement Angle

Search Result 2,166, Processing Time 0.029 seconds

The Effect of Thoracic Joint Mobilization on the Changes of the Thoracic Kyphosis Angle and Static and Dynamic Balance

  • Jeong, Hae-Jin;Kim, Byeong-Jo
    • Biomedical Science Letters
    • /
    • v.25 no.2
    • /
    • pp.149-158
    • /
    • 2019
  • The objective of this study was to evaluate the effects of thoracic mobilization (TM) on the angle of thoracic kyphosis, and static and dynamic balances by application period. The subjects of this study were 18 adult males and females (${\geq}20years\; old$) who had the angle of thoracic kyphosis equal to or higher than $40^{\circ}$. A pre-test was conducted for all subjects and TM was carried out. Data were collected before the intervention, 3 weeks after the intervention, and 6 weeks after the intervention. It was measured three times per measurement and mean values were used for the analysis. The results of this study showed that the angle of thoracic kyphosis significantly (P<.05) decreased after applying TM. However, the migration area ($mm^2$) of the center of pressure (COP) in the static balance did not vary significantly. In the case of the dynamic balance, when eyes were open, the migration area ($mm^2$) of the COP significantly (P<.05) decreased after 3 weeks. When eyes were open, the migration area ($mm^2$) of the COP significantly (P<.05) decreased after 3 weeks and 6 weeks. Therefore, an intervention for improving the human body alignment and balance should be applied for a long-term, rather than a short-term, in order to be effective.

Estimation of Road Surface Condition and Tilt Angle to Improve the Safety of Mobility Aids for the Elderly (노인용 보행보조기의 안전성 향상을 위한 노면 상태 및 기울기 추정)

  • Park, Gi-Dong;Kim, Jong-Hwa;Choi, Jin-Kyu
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.17 no.3
    • /
    • pp.149-155
    • /
    • 2022
  • This paper proposes a method for estimating the road surface condition and tilt angle using an inertial measurement unit (IMU) to improve the safety in the use of mobility aids for the elderly. The measurements of the accelerometers of the IMU usually include the accelerations caused by not only the gravitational force but also linear and rotational motions. Thus, the gravitational accelerations are first extracted using several physical constraints and then incorporated into the Kalman filter to estimate the tilt angle. In addition, because the magnitudes of the accelerations produced by the rotational motions (roll and pitch motions) vary with the road surface condition, a criterion based on such accelerations is presented to classify the condition of the road surface. The obtained road surface condition and tilt angle are finally combined to provide the safety information (e.g., safe, warning, and danger) for the user to improve the walking safety. Experiments were carried out and the results showed that the proposed method can provide the condition of the road surface, the tilt of the road surface, and the safety information correctly.

GA-LADRC based control for course keeping applied to a mariner class vessel (GA-LADRC를 이용한 Mariner class vessel의 선수각 제어)

  • Jong-Kap AHN
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.59 no.2
    • /
    • pp.145-154
    • /
    • 2023
  • In this study, to control the heading angle of a ship, which is constantly subjected to various internal and external disturbances during the voyage, an LADRC (linear active disturbance rejection control) design that focuses more on improving the disturbance removal performance was proposed. The speed rate of change of the ship's heading angle due to the turn of the rudder angle was selected as a significant factor, and the nonlinear model of the ship's maneuvering equation, including the steering gear, was treated as a total disturbance. It is the similar process with an LADRC design for the first-order transfer function model. At this time, the gains of the controller included in LADRC and the gains of the extended state observer were tuned to RCGAs (real-coded genetic algorithms) to minimize the integral time-weighted absolute error as an evaluation function. The simulation was performed by applying the proposed GA-LADRC controller to the heading angle control of the Mariner class vessel. In particular, it was confirmed that the proposed controller satisfactorily maintains and follows the set course even when the disturbances such as nonlinearity, modelling error, uncertainty and noise of the measurement sensor are considered.

Study on Evaluation Method of Flow Characteristics in Steady Flow Bench(4) - Velocity Profile(2) (정상유동 장치에서 유동 특성 평가 방법에 대한 연구(4) - 유속분포(2))

  • Park, Chanjun;Sung, Jaeyong;Ohm, Inyong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.2
    • /
    • pp.242-254
    • /
    • 2016
  • This paper is the forth investigation on the evaluation methods of flow characteristics in a steady flow bench. In the previous works, it was concluded that the assumption of the solid rotation might cause serious problems and both of the eccentricity and the velocity profile distort the flow characteristics when using the ISM at 1.75B plane. Also particle image velocimetry (PIV) measurement at this position showed that the real velocity profile was far from the assumption of ISM evaluation. In this paper, the planar velocity profiles were measure from 1.75B to 6.00B position by PIV and the characteristics were examined according to the valve angles and lifts for further investigations about the effect of the position on the velocity profile. The results show that $26^{\circ}$ valve angle is always an unique exceptional case in all aspects. If the valve angle is $21^{\circ}$ and below, the planar velocity profiles according to the lift and the position are similar to each other, however, the tangential velocity curves along with the radial direction have common tendencies up to $16^{\circ}$ angle. Also the well arranged swirl behaviors are generally observed at the position above 3.00B and the velocity contour lines come closer to the concentric circle as the valve lift increases. In addition, the gradient of tangential velocity along with the radial direction from the swirl center becomes stable and constant as the position goes downstream. Concurrently the velocity gradient is larger to the eccentric direction of the center. In the meantime the tangential velocity curves along with the radial direction are irregular and various at 1.75B, however, they become regular and reach higher level as the evaluation position goes downstream. At this time the curves of 4.50B are the best fitted to the ideal one. On the other hand in an exceptional case, $26^{\circ}$, the velocity contours are very complicated over 6mm valve lift regardless the position and the gradient increases to the opposite direction of the eccentric center. Also, 6.00B is a best fitting position in the geometrical cylinder center base. With respect to the swirl center, the distribution range of centers for 1.75B is different to that for the other positions and the eccentricities of this plane are larger regardless the valve angle. After 1.75B, there is no certain tendency in the center position change according to the valve angle and lift. Additionally, the eccentricities are not sufficiently small to neglecting the effect on ISM measurement.

The Effect of Flexion-distraction Technique and Drop Technique on Pain and Sacral Angle of Patients with Lumbar Spine Herniated Intervertebral Disc (굴곡-신연기법과 낙차 교정법이 허리 척추사이원반 탈출증 환자의 시각적 상사 척도 및 엉치뼈 각에 미치는 영향)

  • Oh, Hyun-Ju;Choi, Seok-Joo;Lee, Kwan-Sub;Choi, Ji-Oun
    • Journal of Korean Physical Therapy Science
    • /
    • v.25 no.3
    • /
    • pp.9-16
    • /
    • 2018
  • Background: In order to find out the effect of therapy methods through Flexion-distraction technique and drop technique on pain, sacral angle of patients with lumbar herniated intervertebral disc targeting patients with lumbar herniated intervertebral disc due to L5-S1. Method: This study was to present the directivity of the therapy method for lumbar herniated intervertebral disc by comparing and analyzing the spinal decompression therapy and provide an effective treatment method to patients with lumbar herniated intervertebral disc by identifying the therapeutic effect of Flexion-distraction technique and drop technique. The research period is March 1, 2018 to June 30, 2018 and subjects are the patients diagnosed as lumbar herniated intervertebral disc due to L5-S1 by their doctor through clinical findings and medical equipment such as X-ray, CT, MRI etc. Among patients who visited and hospitalized in S Orthopaedics located in Daegu and 30 female patients with sacral angle of more than $30^{\circ}$ were randomly classified into 15 people and we carried out treatment three times a week for 8 weeks for 15 people in the experimental group applying Flexion-distraction technique and drop technique and 15 people in the control group applying spinal decompression therapy to compare and analyze the changes in pain, sacral angle of patients with lumbar herniated intervertebral disc. Result: According to the results of this study, changes in the Visual Analogue Scale showed statistically significant differences in both the experimental group and control group(p<.05), while there was statistically significant difference in the comparison between groups before and after measurement of experimental group (p<.05). In the comparison within two groups of sacral angle, both groups showed statistically significant difference(p<.05) but there was no statistically significant difference in the comparison of scores between groups before and after measurement of each group(p>.05). Discussion: All those results the above proved that we need to confirm various benefits of the therapy with the flexion-distraction technique and drop technique, and the findings of the concerned study will possibly become useful information when doctors actually work on a therapy to treat patients with the lumbar herniated intervertebral disc.

The Study of Appropriate X-ray Tube Angle for the Anterior-posterior Chest Radiography Using S-align Function (S-align 기능을 이용한 흉부 전·후 방향 검사 시 적절한 X선관 각도에 관한 연구)

  • Park, Myeong-Ju;Joo, Young-Cheol;Kim, Min-Suk;Yuk, Jeong-Won;Kim, Han-Yong;Kim, Dong-Hwan
    • Journal of radiological science and technology
    • /
    • v.45 no.4
    • /
    • pp.299-304
    • /
    • 2022
  • This study uses the 'S-align' function to present a reference value of the X-ray tube angle for the realization of an image similar to that of the chest PA image during chest AP radiography. This study targeted dummy phantom and used a 17"×17" DR image receptor. The irradiation conditions were 110 kVp, 160 mA, 50 ms, and the distance between the central X-ray and the image receptor was set to 180 cm and 110 cm, respectively. The end of the catheter was placed at the 11th thoracic height to indicate the nasogastric tube. In the case of lung apex length measurement, the mean value of measurement was 30.53±0.47 in PA. T 0°, TCA 5~25°, TCE 5~15° were 21.07±0.29, 27.60±0.21, 34.13±0.44, 39.86±0.31, 45.96±0.61 mm, 54.13±0.37 mm, 16.16±0.46 mm, 9.81±0.35 mm, 2.75±0.30 mm, respectively. For the depth of the catheter end, the average value measured at PA was 6.70±0.31 mm. T 0°, TCA 5~25°, TCE 5~15° were 15.72±0.38 mm, 24.10±0.50 mm, 29.24±0.86 mm, 34.35±0.35 mm, 41.06±1.08 mm, 48.07±0.38 mm, 12.85±0.25 mm, 7.92±0.36 mm, 3.01±0.39 mm, respectively. The length of the lung apex was similar to that of chest PA when the angle of incidence was adjusted from 5° to 10° in the leg direction, and the depth of the catheter tip was most similar when the X-ray tube angle was incident at 10° in the head direction. Therefore, To change the X-ray tube angle according to the purpose of the examination during the chest AP radiography using 'S-align' function is considered necessary.

Intra-Rater and Inter-Rater Reliability of Various Forward Head Posture Measurements

  • Yoo, Won-Gyu;Kim, Min-Hee;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.12 no.4
    • /
    • pp.41-47
    • /
    • 2005
  • The purpose of this study was to determine the intra-rater and inter-rater reliability of various forward head posture measurements. Ten healthy adults (age, $20.4{\pm}2.2$ yrs; height, $164.0{\pm}5.5$ cm; weight, $58.7{\pm}7.3$ kg) participated in the study. They were free of injury and neurologic deficits in the upper extremities and neck at the time of testing. The subjects were asked to perform head forward posture by under the guidance of physical therapists. Markers were placed on the C7 spinous process, mastoid process, tragus of the ear, outer canthus, and forehead. Measurement 1 for forward head posture assessment was measured as the angle between the horizontal line through C7 and the line connecting the C7 spinous process with the tragus of the ear. Measurement 2 was measured as the angle between the C7 spinous process, the mastoid process and the outer canthus. Measurement 3 was measured as two kinds of angles the HT (head tilt) angle is between the line from the midpoint of forehead to the tragus line and Y-axis at the tragus point. The NF (neck flexion) angle is between the line from the tragus to the C7 line and the Y-axis at the C7. Intra-rater, inter-rater reliability and coefficient of variation was assessed by comparing the measured values from three kinds of measurements of forward head posture. The intra-rater reliability was indicated by intraclass correlation coefficients [ICC(1,1)] and inter-rater reliability was shown by intraclass correlation coefficients [ICC(3,k)]. The results of study were as follows: ICC(1,1) values for intra-rater reliability of three measurements were in the 'excellent' category. ICC(3,k) values for inter-rater reliability of three measurements were also in the 'excellent' category. The coefficient of variation of method 2 had a lower value than method 1 and method 3. This data means that the measured value of method 2 was less scattered. Further research is needed to determine whether the validity of all measurements is revealed in the 'excellent' category.

  • PDF

Medial Gastrocnemius Ultrasound Imaging of Delayed Onset Muscle Soreness over time (시간경과에 따른 지연성근통증 내측 비복근의 초음파 영상)

  • Lee, Wan-Hee;Cho, Ki-Hun;Lee, Kyoung-Suk;Kim, Mi-Hwa
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.6
    • /
    • pp.2632-2640
    • /
    • 2012
  • The purpose of this study was to investigate whether medial gastrocnemius ultrasound imaging of the Delayed Onset Muscle Soreness (DOMS) has the possibilities as a measurement method. This study was conducted from April 21th 2011 to April 30th 2011. Thirty-five healthy subjects were included based on the absence of regular physical activity, and no history of recent trauma, musculoskeletal pathology, cardiovascular disease or drug intake. All subjects induced DOMS through climbing for 5 hours and we measured the visual analogue scale (VAS), creatine kinase (CK) and maximal voluntary isometric contraction (MVlC) of ankle plantar flexor prior to DOMS and at 24, 48 and 72 hours post DOMS and these measurements were compared with pennation angle of medial gastrocnemius measured by ultrasound imaging. Results of this study were as following. VAS, CK, and MVIC of ankle plantar flexor were found significant difference related measurement period (p<0.05) and pennation angle of medial gastrocnemius were found significant difference related measurement period (p<0.05). Furthermore, we confirmed that the flow of change between variables related measurment period was consistent. Through this study, we think that measuring the changes in pennation angle of medial gastrocnemius over time using ultrasound imaging will be able to be used as a new method measuring DOMS.

A Study on the Improvement of Indoor Thermal and Air Environment Made by Ceiling Cassette Type Cooling and Heating Unit in Classrooms (천장 카세트형 냉·난방기에 의해 형성되는 학교 교실의 실내 열환경 및 공기환경의 개선에 대한 연구)

  • Chang, Hyun-Jae;Lee, Ha-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.141-148
    • /
    • 2012
  • Ceiling cassette type air conditioner has been a main stream as a heating/cooling system recently in school, Korea. In this study, indoor thermal environments made by ceiling cassette type air conditioner were investigated by CFD simulation. Concentrations of $CO_2$ were investigated by a field measurement. Indoor thermal environment with the velocity inlet angle of $45^{\circ}$ from the ceiling in heating season was very ununiform so that thermal area was divided into two parts those the one is window side which is cold, and the other is corridor side which is hot. In cooling season under the same condition, there are areas too hot or too cold. If the velocity inlet angle is set in $30^{\circ}$ from the ceiling, indoor thermal environments was improved greatly in cooling season and heating season, too. Also, from the field measurement of $CO_2$ concentrations, it was suggested to install ventilators with proper air volume considered the number of class students.

Evaluation of manual workload in repetitive wrist and finger motion (반복적인 손목 및 손가락 작업에서의 수작업 부하 평가)

  • Gwon, O-Chae;Yun, Myeong-Hwan
    • Journal of the Ergonomics Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.103-120
    • /
    • 1999
  • The purpose of this study was to evaluate the manual workload in repetitive wrist and finger motion. To evaluate manual workload, angular displacement of the joint, EMG of the muscle and subjective rating were studied. Both wrist motion and finger motion were studied. A screw-driving task was used for the wrist motion experiment. A keyboard typing task was used for the finger motion experiment. All finger joint angles and wrist angles were measured by an angle-measuring glove($CyberGlove^{TM}$, Virtual Technologies, Inc.). Surface EMG was recorded from FCU muscle and FDS muscle simultaneously with the angle measurement. Subjective ratings of exertion were also recorded using the modified Borg's CR-10 scale. Repetition rates of 0.5, 1, 2 motions per second were used with each task. As a result, manual workload increased with increasing repetitiveness. Peak spectral magnitude and frequency components corresponded closely with joint angular displacement amplitudes and repetition rates. Results of the correlation analysis showed that there were significant correlation among EMG, frequency-weighted motion and subjective measurement. Both EMG and frequency-weighted filtering showed consistent workload estimation with increasing task frequency. Subjective ratings showed slight over-estimation of the workload as the task frequency is increased.

  • PDF