• Title/Summary/Keyword: Measured displacement

Search Result 1,726, Processing Time 0.029 seconds

Vibration and Noise Level on the Training Ship Pusan 403 (실습선 부산 403호의 진동과 소음)

  • Park, Jung Hee
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.23 no.2
    • /
    • pp.8-8
    • /
    • 1987
  • This paper describes on the distribution of the vibration and the noise produced on a skipjack pole and line training ship M/S Pusan 403 (243GT, 1,000ps) under the cruising or drifting condition. The vibration and the noise level were measured by use of protable vibration analyzer (B and K 3513) and sound level meter (B and K 2205), and so the vibration level was converted into dB unit. The check points were set through every decks and around important places of the ship. The results obtained can be summarized as follows: 1. The vibration and the noise level 1) On the main deck, both the vibration and the noise level were highest at the vertically above the main engine, whereas the vibration level was the lowest in the bow store and the noise level beneath the bridge. 2) Under cruising condition, the vibration level around the cylinder head of main engine, port side of the engine room, on the shaft tunnel was 80, 67, 65 dB and the noise level 104, 87, 86 dB, respectively. 3) The vibration level on the vertical line passing through the bridge was the highest at the orlop deck with 60 dB and the lowest on the bridge deck with 55 dB, whereas the noise level the highest at the compass deck with 75 dB and the lowest at the orlop deck with 53 dB. 4) The vibration and the noise level on the open decks were the highest with 65 dB and 84 dB on the boat deck, whereas the vibration level was the lowest at the lecture room with 51 dB and the noise level the lowest at the fore castle deck with 57 dB. 5) On the orlop decks, both the vibration and the noise level were the highest at the engine room with 65 dB and 85 dB, and the lowest at bow store with 54 dB and 52 dB, respectively. Comparing with the vibration level and the noise level, the vibration level was higher than the noise level in the bow part and it was contrary in the stern part of the ship. 2. Vibration analysis 1) The vibration displacement and the vibration velocity were the greatest at the cylinder head of main engine with 100μm and 11mm/sec, and were the smallest at the compass deck with 3μm and 0.07mm/sec. They were also attenuated rapidly around the frequency of 100Hz and over. 2) The vibration acceleration was the greatest at the cylinder head with the main frequency of 1KHz and the acceleration of 1.1mm/sec super(2), and the smallest at the compass deck with 30KHz and 0.05mm/sec super(2).

Vibration and Noise Level on the Training Ship Pusan 403 (실습선 부산 403호의 진동과 소음)

  • 박중희
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.23 no.2
    • /
    • pp.54-60
    • /
    • 1987
  • This paper describes on the distribution of the vibration and the noise produced on a skipjack pole and line training ship M/S Pusan 403 (243GT, 1,000ps) under the cruising or drifting condition. The vibration and the noise level were measured by use of protable vibration analyzer (B and K 3513) and sound level meter (B and K 2205), and so the vibration level was converted into dB unit. The check points were set through every decks and around important places of the ship. The results obtained can be summarized as follows: 1. The vibration and the noise level 1) On the main deck, both the vibration and the noise level were highest at the vertically above the main engine, whereas the vibration level was the lowest in the bow store and the noise level beneath the bridge. 2) Under cruising condition, the vibration level around the cylinder head of main engine, port side of the engine room, on the shaft tunnel was 80, 67, 65 dB and the noise level 104, 87, 86 dB, respectively. 3) The vibration level on the vertical line passing through the bridge was the highest at the orlop deck with 60 dB and the lowest on the bridge deck with 55 dB, whereas the noise level the highest at the compass deck with 75 dB and the lowest at the orlop deck with 53 dB. 4) The vibration and the noise level on the open decks were the highest with 65 dB and 84 dB on the boat deck, whereas the vibration level was the lowest at the lecture room with 51 dB and the noise level the lowest at the fore castle deck with 57 dB. 5) On the orlop decks, both the vibration and the noise level were the highest at the engine room with 65 dB and 85 dB, and the lowest at bow store with 54 dB and 52 dB, respectively. Comparing with the vibration level and the noise level, the vibration level was higher than the noise level in the bow part and it was contrary in the stern part of the ship. 2. Vibration analysis 1) The vibration displacement and the vibration velocity were the greatest at the cylinder head of main engine with 100$\mu$m and 11mm/sec, and were the smallest at the compass deck with 3$\mu$m and 0.07mm/sec. They were also attenuated rapidly around the frequency of 100Hz and over. 2) The vibration acceleration was the greatest at the cylinder head with the main frequency of 1KHz and the acceleration of 1.1mm/sec super(2), and the smallest at the compass deck with 30KHz and 0.05mm/sec super(2).

  • PDF

A Theoretical Model for the Analysis of Residual Motion Artifacts in 4D CT Scans (이론적 모델을 이용한 4DCT에서의 Motion Artifact 분석)

  • Kim, Tae-Ho;Yoon, Jai-Woong;Kang, Seong-Hee;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.145-153
    • /
    • 2012
  • In this study, we quantify the residual motion artifact in 4D-CT scan using the dynamic lung phantom which could simulate respiratory target motion and suggest a simple one-dimension theoretical model to explain and characterize the source of motion artifacts in 4DCT scanning. We set-up regular 1D sine motion and adjusted three level of amplitude (10, 20, 30 mm) with fixed period (4s). The 4DCT scans are acquired in helical mode and phase information provided by the belt type respiratory monitoring system. The images were sorted into ten phase bins ranging from 0% to 90%. The reconstructed images were subsequently imported into the Treatment Planning System (CorePLAN, SC&J) for target delineation using a fixed contour window and dimensions of the three targets are measured along the direction of motion. Target dimension of each phase image have same changing trend. The error is minimum at 50% phase in all case (10, 20, 30 mm) and we found that ${\Delta}S$ (target dimension change) of 10, 20 and 30 mm amplitude were 0 (0%), 0.1 (5%), 0.1 (5%) cm respectively compare to the static image of target diameter (2 cm). while the error is maximum at 30% and 80% phase ${\Delta}S$ of 10, 20 and 30 mm amplitude were 0.2 (10%), 0.7 (35%), 0.9 (45%) cm respectively. Based on these result, we try to analysis the residual motion artifact in 4D-CT scan using a simple one-dimension theoretical model and also we developed a simulation program. Our results explain the effect of residual motion on each phase target displacement and also shown that residual motion artifact was affected that the target velocity at each phase. In this study, we focus on provides a more intuitive understanding about the residual motion artifact and try to explain the relationship motion parameters of the scanner, treatment couch and tumor. In conclusion, our results could help to decide the appropriate reconstruction phase and CT parameters which reduce the residual motion artifact in 4DCT.

Structural Safety Test and Analysis of Type IP-2 Transport Packages with Bolted Lid Type and Thick Steel Plate for Radioactive Waste Drums in a NPP (원자력발전소의 방사성폐기물 드럼 운반을 위한 볼트체결방식의 두꺼운 철판을 이용한 IP-2형 운반용기의 구조 안전성 해석 및 시험)

  • Lee, Sang-Jin;Kim, Dong-hak;Lee, Kyung-Ho;Kim, Jeong-Mook;Seo, Ki-Seog
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.3
    • /
    • pp.199-212
    • /
    • 2007
  • If a type IP-2 transport package were to be subjected to a free drop test and a penetration test under the normal conditions of transport, it should prevent a loss or dispersal of the radioactive contents and a more than 20% increase in the maximum radiation level at any external surface of the package. In this paper, we suggested the analytic method to evaluate the structural safety of a type IP-2 transport package using a thick steel plate for a structure part and a bolt for tying a bolt. Using an analysis a loss or dispersal of the radioactive contents and a loss of shielding integrity were confirmed for two kinds of type IP-2 transport packages to transport radioactive waste drums from a waste facility to a temporary storage site in a nuclear power plant. Under the free drop condition the maximum average stress at the bolts and the maximum opening displacement of a lid were compared with the tensile stress of a bolt and the steps in a lid, which were made to avoid a streaming radiation in the shielding path, to evaluate a loss or dispersal of radioactive waste contents. Also a loss of shielding integrity was evaluated using the maximum decrease in a shielding thickness. To verify the impact dynamic analysis for free drop test condition and evaluate experimentally the safety of two kinds of type IP-2 transport packages, free drop tests were conducted with various drop directions. For the tests we examined the failure of bolts and the deformation of flange to evaluate a loss or dispersal of radioactive material and measured the shielding thickness using a ultrasonic thickness gauge to assess a loss of shielding integrity. The strains and accelerations acquired from tests were compared with those by analyses to verify the impact dynamic analysis. The analytic results were larger than the those of test so that the analysis showed the conservative results. Finally, we evaluated the safety of the type IP-2 transport package under the stacking test condition using a finite element analysis. Under the stacking test condition, the maximum Tresca stress of the shielding material was 1/3 of the yielding stress. Two kinds of a type IP-2 transport package were safe for the free drop test condition and the stacking test condition.

  • PDF

Evaluation of the Usefulness of the Self-developed Kw-infrared Reflective Marker in Non-coplanar Treatment (비동일면 치료 시 자체 제작한 Kw-infrared Reflective Marker의 유용성 평가)

  • Kwon, Dong-Yeol;Ahn, Jong-Ho;Park, Young-Hwan;Song, Ki-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.25-32
    • /
    • 2010
  • Purpose: In radiotherapy that takes into account respiration using a RPM (Real time Position Management, Varian, USA) system, which can treat in consideration of the movement of tumor, infrared reflective markers supplied by manufacturers cannot obtain respiratory signal if the couch rotates at a certain angle or larger. In order to solve this problem, the author developed the 3D infrared reflective marker named 'Kw-marker' that can obtain respiratory signal at any angle, and evaluate its usefulness. Materials and Methods: In order to measure the stability of respiratory signal, we put the infrared reflective marker on the 3D moving phantom that can reproduce respiratory movement and acquired respiratory signal for 3 minutes under each of 3 conditions (A: $couch\;0^{\circ}$, a manufacturer's infrared reflective marker B: $couch\;0^{\circ}$, Kw-marker C: $couch\;90^{\circ}$, Kw-marker). By analyzing the respiratory signal using a breath analysis program (Labview Ver. 7.0), we obtained the peak value, valley value, standard deviation, variation value, and amplitude value. In order to examine the rotation error and moving range of the target, we placed a B.B phantom on the 3D moving phantom, and obtained images at a couch angle of $0^{\circ}$ and $90^{\circ}$ using OBI, and then acquired the X, Y and Z values (mm) of the ball bearing at the center of the B.B phantom. Results: According to the results of analyzing the respiratory signal, the standard deviation at the peak value was A: 0.002, B: 0.002 and C: 0.003, and the stability of respiration for amplitude was A: 0.15%, B: 0.14% and C:0.13%, showing that we could get respiratory signal stably by using the Kw-marker. When the couch rotated $couch\;90^{\circ}$, the mean rotation error of the ball bearing, namely, the target was X: -1.25 mm, Y: -0.45 mm and Z: +0.1 mm, which were within 1.3 mm on the average in all directions, and the difference in the moving range of the target was within 0.3 mm. Conclusion: When we obtained respiratory signal using the Kw-marker in non-coplanar treatment where the couch rotated, we could acquire respiratory signal stably and the Kw-marker was effective enough to substitute for the manufacturer's infrared reflective marker. When the rotation error and moving range of the target were measured, there was little difference, indicating that the displacement of the reflector movement in couch rotation is the cause of change in the scale and amplitude of respiratory signal. If the converted value of amplitude height according to couch angle is studied further and applied, it may be possible to perform non-coplanar phase-based gating treatment.

  • PDF

Evaluation on Usefulness of Abdomen and Chest Motion Control Device (ABCHES) for the Tumor with a Large Respiratory Motion in Radiotherapy (호흡으로 인한 움직임이 큰 종양의 방사선치료 시 Abdomen and Chest Motion Control Device (ABCHES)의 유용성 평가)

  • Cho, Yoon-Jin;Jeon, Mi-Jin;Shin, Dong-Bong;Kim, Jong-Dae;Kim, Sei-Joon;Ha, Jin-Sook;Im, Jung-Ho;Lee, Ik-Jae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.85-93
    • /
    • 2012
  • Purpose: It is essential to minimize the respiratory-induced motion of involved organs in the Tomotherapy for tumor located in the chest and abdominal region. However, the application of breathing control system to Tomotherapy is limited. This study was aimed to investigate the possible application of the ABCHES system and its efficacy as a means of breathing control in the tomotherapy treatment. Materials and Methods: Five subjects who were treated with a Hi-Art Tomotherapy system for lung, liver, gallbladder and pancreatic tumors. All patients undertook trained on two breathing methodes using an ABCHES, free breathing methode and shallow breathing methode. When the patients could carry out the breathing control, 4D-CT scan was a total of 10 4D tomographic images were acquired. A radiologist resident manually drew the tumor region, including surrounding nomal organs, on each of CT images at the inhalation phase, the exhalation phase and the 40% phase (mid-inhalation) and average CT image. Those CT images were then exported to the Tomotherapy planning station. Data exported from the Tomotherapy planning station was analyzed to quantify characteristics of dose-volume histograms and motion of tumors. Organ motions under free breathing and shallow breathing were examined six directions, respectively. Radiation exposure to the surrounding organs were also measured and compared. Results: Organ motion is in the six directions with more than a 5 mm displacement. A total of 12 Organ motions occurred during free breathing while organ motions decreased to 2 times during shallow breathing under the use of Abches. Based on the quantitative analysis of the dose-volume histograms shallow breathing showed lower resulting values, compared to free breathing, in every measure. That is, treatment volume, the dose of radiation to the tumor and two surrounding normal organs (mean doses), the volume of healthy tissue exposed to radiation were lower at the shallow breathing state. Conclusion: This study proposes that the use of ABCHES is effective for the Tomotherapy treatment as it makes shortness of breathing easy for patients. Respiratory-induced tumor motion is minimized, and radiation exposure to surrounding normal tissues is also reduced as a result.

  • PDF

Combined Reconstruction of Posterior Cruciate Ligament and Posterolateral Corner with a Fresh Frozen Achilles Tendon Allograft (한 개의 신선동결 동종아킬레스건을 이용한 후방십자인대 및 후외방구조의 동시 재건술)

  • Kyung, Hee-Soo;Oh, Chang-Wug;Lee, Hyun-Joo;Ihn, Joo-Chul
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.8 no.2
    • /
    • pp.102-108
    • /
    • 2009
  • Purpose: The purpose of this study is to report a result of the technique that reconstruct posterior cruciate ligament (PCL) and posterolateral corner (PLC) simultaneously using a fresh-frozen Achilles tendon allograft. Materials and Methods: Forty two patients (45 legs) underwent PCL and PLC reconstruction were included. There were 38 males and 4 females. Mean age was 39 years. Used graft was a fresh frozen Achilles tendon allograft, which was divided by two size, larger one (${\emptyset}$ 10 mm) for PCL reconstruction and smaller one (${\emptyset}$ 8 mm) for PLC reconstruction. Arthroscopic reconstruction of the PCL was performed using transtibial, single incision, and single bundle technique with 10mm fresh frozen Achilles allograft tendon first. After PCL reconstruction, reconstruction procedure for posterolateral instability was performed using modified figure of "8" technique using smaller gtaft. For clinical evaluation, range of motion, posterior drawer test, varus stress test, prone external rotation (dial) test, Lysholm score, Tegner activity scale and posterior stress radiograph were used. Mean follow up period was 25 months. Results: Preoperatively posterior drawer test was 5 cases in grade II and 40 cases in grade III posterior instability. At final follow-up 22 cases returned within normal condition, 18 cases grade I and 5 cases grade II posterior instability. Though all patients showed positive result over 10 degrees in dial and varus stress test preoperatively, but only 9 cases showed positive both test at final follow-up. The range of motion deficit over $10^{\circ}$ flexion was 3 cases. Lysholm score was improved from mean 50 preoperatively to mean 83(p<0.05) and Tegner activity scale improved from mean 2.1 preoperatively to mean 4.6(p<0.05). In posterior stress radiographs, posterior displacement was improve from mean 16mm preoperatively to 4.1mm after treatment(p<0.05). All patients had improved compared to their pre-operative status as measured by physical examination such as posterior drawer test, varus stress test, dial test. Conclusion: We had successful results by combined reconstruction of the PCL & PLC with a fresh frozen Achilles tendon allograft in patients with PCL and posterolateral rotatory instability at a time.

  • PDF

A STUDY OF THE STRESS DISTRIBUTION OF THE ABUTMENT AND SUPPORTING TISSUES ACCORDING TO THE SLOPES AND TYPES OF CHIDING FLAMES OF THE LAST ABUTMENT IN DISTAL EXTENSION REMOVABLE PARTIAL DENTURE USING THREE DIMENSIONAL FINITE ELEMENT ANALYSIS METHOD (국소의치 최후방 지대치 유도면의 기울기와 형태가 지대치 및 지지조직의 응력분산에 미치는 영향)

  • Kim, Yang-Kyo;Lee, Cheong-Hee;Jo, Kwang-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.5
    • /
    • pp.581-596
    • /
    • 1999
  • The purpose of this study was to investigate the stress distribution of the abutment and sup-porting tissues according to the slopes and types of the guiding plane of distal extension removable partial dentures. The 3-dimensional finite element method was used and the finite element models were prepared as follows. Model I : Kratochvil type guiding plane with $90^{\circ}$ to residual ridge Model II : Kratochvil type guiding plane with $95^{\circ}$ to residual ridge Model III : Kratochvil type guiding plane with $100^{\circ}$ to residual ridge Model IV : Krol type guiding plane with $90^{\circ}$ to residual ridge Distal extension partial denture which right mandibular first and second molar were lost was used and the second premolar was prepared as primary abutment with RPI type retainer. Then 150N of compressive force was applied to central fossae of the first and second molars and von Mises stress and displacement were measured. The results were as follows 1. Model I and Model IV showed a similar stress distribution pattern and the stress was concentrated on the apex of the root of the abutment. 2. The stress was increased and concentrated on mesial side of the root of the abutment in Model II. The stress was concentrated on buccal and mesiobuccal side of the root of the abutment in Model IV. 3. In Model I, the root of the abutment displaced and twisted a little in clockwise. In Model IV, the root of the abutment displaced to distolingually at apical region of the root and mesiobuccally at cervical region of the root. 4. In Model II, the root of the abutment displaced to mesiolingually at apical region of the root and more displaced and twisted in counterclockwise at cervical region of the root. In Model III, the root of the abutment displaced to mesiobucally at apical region of the root and more displaced and twisted in clockwise at cervical region of the root.

  • PDF

Effects of Insamjungchuntang on the Respiratory System in Experimental Animals (인삼정천탕(人蔘定喘湯)이 호흡기계(呼吸器系)에 미치는 영향(影響))

  • Kim, Ho-Soon;Shin, Jo-Young
    • The Journal of Internal Korean Medicine
    • /
    • v.19 no.1
    • /
    • pp.409-427
    • /
    • 1998
  • Insamjungchuntang has been used in Korea for many centuries as a treatment for respiratory disease. The effect of Insamjungchuntang on tracheal smooth muscle is not known. The purpose of the present study is to determine the effect of Insamjungchuntang on histamine and acetylcholine induced tracheal smooth muscle contraction in rats and guinea pigs. Guinea pig (500 g, male) and Sprague Dawley rats (200 g, male) were killed by $CO_2$ exposure and a segment (8-10 mm) of the thoracic trachea from each rat and guinea pig was cut into equal segments and mounted 'in pairs' in a tissue bath. Contractile force was measured with force displacement transducers under 0.5 g loading tension. The dose of histamine (His) and acetylcholine (Ach) which evoked 50% of maximal response $(ED_{50})$ was obtained from cumulative dose response curves for histamine and acetylcholine$(10^{-7}{\sim}10^{-4}\;M)$. Contractions evoked by His ($ED_{50}$) and Ach $(ED_{50})$ were inhibited significantly by Insamjungchuntang. In guinea pig tracheal smooth muscle, the mean percent inhibition of acetylcholine induced contraction was $38.58\(p<0.05)\;after\;10{\mu}l/ml$ Insamjungchuntang, $90.75\(p<0.01)\;after\;30{\mu}l/ml$. Insamjungchuntang and $133.17\(p<0.01)\;after\;100{\mu}l/ml$ Insamjungchuntang. In rat tracheal smooth muscle, the mean percent inhibition of acetylcholine induced contraction was $10.0\(p<0.05)\;after\;10{\mu}l/ml$ Insamjungchuntang, $80.71\(p<0.01)\;after\;30{\mu}/ml$ Insamjungchuntang and $118.29\(p<0.01)\;after\;100{\mu}l/ml$ Insamjungchuntang. Also, in guinea pig tracheal smooth muscle, the mean percent inhibition of histamine induced contraction was $45.5\(p<0.01)\;after\;10{\mu}l/ml$ lnsamjungchuntang, and $93.17\(p<0.01)\;after\;30{\mu}l/ml$. lnsamjungchuntang $134.50\(p<0.01)\;after\;100{\mu}l/ml$ Insamjungchuntang. In rat tracheal smooth muscle, the mean percent inhibition of histamine induced contraction was $37.83\(p<0.01)\;after\;10{\mu}l/ml$ lnsamjungchuntang, $90.5\(p<0.01)\;after\;30{\mu}l/ml$ Insamjungchuntang and $135.17\(p<0.01)\;after\;100{\mu}l/ml$ Insamjungchuntang. Propranolol $(10^{-7}\;M)$ slightly but significantly attenuated the inhibitory effects of Insamjungchuntang. Following treatment with propranolol, the mean percent inhibition caused by $100{\mu}l/ml$. Insamjungchuntang fell to 46.42% in guinea pig induced by acetylcholine contraction and by $100{\mu}l/ml$ Insamjungchuntang fell to 5.43% (p<0.05) in rat induced by acetylcholine contraction and the mean percent inhibition caused by $100{\mu}l/ml$ Insamjungchuntang fell to 49.0% in guinea pig induced by histamine contraction and by $100{\mu}l/ml$ Insamjungchuntang fell to 48.6% (p<0.05) in rat induced by histamine contraction. Indomethacin and methylene blue $(10^{-7}\;M)$ did not significantly alter the inhibitory effect of lnsamjungchuntang. Also, I could find the effects of lnsamjungchuntang and Insamjungchuntanggamorphine on the tracheal smooth muscle in guinea pig and rat did not change significantly. These results indicate that Insamjungchuntang can relax histamine and acetylcholine-induced contraction of guinea pig and rat tracheal smooth muscle, and that this inhibition involves sympathetic effects.

  • PDF

Experimental Evaluation of Bi-directionally Unbonded Prestressed Concrete Panel Impact-Resistance Behavior under Impact Loading (충돌하중을 받는 이방향 비부착 프리스트레스트 콘크리트 패널부재의 충돌저항성능에 대한 실험적 거동 평가)

  • Yi, Na-Hyun;Lee, Sang-Won;Lee, Seung-Jae;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.5
    • /
    • pp.485-496
    • /
    • 2013
  • In recent years, frequent terror or military attacks by explosion or impact accidents have occurred. Examplary case of these attacks were World Trade Center collapse and US Department of Defense Pentagon attack on Sept. 11 of 2001. These attacks of the civil infrastructure have induced numerous casualties and property damage, which raised public concerns and anxiety of potential terrorist attacks. However, a existing design procedure for civil infrastructures do not consider a protective design for extreme loading scenario. Also, the extreme loading researches of prestressed concrete (PSC) member, which widely used for nuclear containment vessel, gas tank, bridges, and tunnel, are insufficient due to experimental limitations of loading characteristics. To protect concrete structures against extreme loading such as explosion and impact with high strain rate, understanding of the effect, characteristic, and propagation mechanism of extreme loadings on structures is needed. Therefore, in this paper, to evaluate the impact resistance capacity and its protective performance of bi-directional unbonded prestressed concrete member, impact tests were carried out on $1400mm{\times}1000mm{\times}300mm$ for reinforced concrete (RC), prestressed concrete without rebar (PS), prestressed concrete with rebar (PSR, general PSC) specimens. According to test site conditions, impact tests were performed with 14 kN impactor with drop height of 10 m, 5 m, 4 m for preliminary tests and 3.5 m for main tests. Also, in this study, the procedure, layout, and measurement system of impact tests were established. The impact resistance capacity was measured using crack patterns, damage rates, measuring value such as displacement, acceleration, and residual structural strength. The results can be used as basic research references for related research areas, which include protective design and impact numerical simulation under impact loading.