• Title/Summary/Keyword: Measured Rate System

Search Result 2,502, Processing Time 0.051 seconds

A Study on the Double-Wall Greenhouse Filled with Styrene Pellets (입자충전형 이중벽 온실에 관한 연구)

  • 이석건;이종원;이현우
    • Journal of Bio-Environment Control
    • /
    • v.4 no.1
    • /
    • pp.59-67
    • /
    • 1995
  • This study was conducted to develope the automatic insulation system which control inside temperature of the greenhouse. For this purpose, the double- wall greenhouse and system which could automatically supply and discharge styrene pellets were constructed and abrasion of the pellets, blower ability, insulating property, transmittance and shading effect were analyzed by the experiments. The results obtained from this study can be summarized as follows : 1. It took an hour and fifteen minutes to supply and discharge about 2㎥ pellets in the experimental greenhouse. However, it is possible to reduce the operation time by proper selection of the blower and exhaust port, and by proper control of the supply and return pipe. 2. It was founded that the indirect delivery way was more profitable than the direct one in the supply and return of pellets. 3. When the transmittance was measured between 10 a.m. and 3 p.m., the average light transmissivity rate was 67%. 4. In winter nighttime, the inside temperature of the double- wall greenhouse with out the pellets was higher than the outside temperature by 3.4$^{\circ}C$ on an average. However, the inside temperature of the double - wall greenhouse with insulated area 73% was higher than the outside by one 6.6$^{\circ}C$ on an average, and the inside temperature of the greenhouse with insulated area 100% was higher than outside one by 13.5$^{\circ}C$ on an average. Therefore, it was proved that the insulating ability of the double - wall greenhouse in nighttime was excellent. 5. When the outside temperature was 36.9$^{\circ}C$ on an average, the inside temperature of the double- wail greenhouse with insulated area 100% was 3$0^{\circ}C$ on an average. As the inside temperature was lower than the outside one by 7$^{\circ}C$ on an average, we could know that the shading effects of the double- wall greenhouse were excellent in summer daytime.

  • PDF

The Clinical Effect and Construction of a Stereotactic Whole Body Immobilization Device (전신 정위 고정장치 제작과 임상효과에 대한 연구)

  • 정진범;정원균;서태석;최경식;진호상;지영훈
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.30-38
    • /
    • 2004
  • Purpose: To develop a whole body frame for the purpose of reducing patient motion and minimizing setup error for extra-cranial stereotactic radiotherapy, and to evaluate the repositioning setup error of a patient in the frame. Materials and Methods: The developed whole body frame is composed of a base plate, immobilizer, vacuum cushion, ruler and belts. The dimension of the base plate is 130 cm in length, 50 cm in width and 1 cm in thickness. The material used in the base plate of the frame was bakelite and the immobilizer was made of acetal. In addition, Radiopaque angio-catheter wires were engraved on the base plate for a coordinate system to determine the target localization. The measurement for radiation transmission and target localization is peformed in order to test the utilization of the frame. Also, a Matlab program analyzed the patients setup error by using the patient's setup images obtained from a CCTV camera and digital record recorder (DVR). Results: A frame that is useful for CT simulation and radiation treatment was fabricated. The frame structure was designed to minimize collisions from the changes in the rotation angle of the gantry and to maximize the transmission rate of the Incident radiation at the lateral or posterior oblique direction. The lightening belts may be used for the further reduction of the patient motion, and the belts can be adjusted so that they are not in the way of beam direction. The radiation transmission rates of this frame were measured as 95% and 96% at 10 and 21 MV, respectively. The position of a test target on the skin of a volunteer is accurately determined by CT simulation using the coordinate system in the frame. The estimated setup errors by Matlab program are shown 3.69$\pm$1.60, 2.14$\pm$0.78 mm at the lateral and central chest, and 7.11 $\pm$2.10, 6.54$\pm$2.22 mm at lateral and central abdomen, respectively. The setup error due to the lateral motion of breast is shown as 6.33$\pm$ 1.55 mm. Conclusion: The development and test of a whole body frame has proven very useful and practical in the radiosurgery for extra-cranial cancers. It may be used in determining target localization, and it can be used as a patient immobilization tool. More experimental data should be obtained in order to improve and confirm the results of the patient setup error.

  • PDF

Effect of Temperature and Gas Permeability of Functional Packing Films on Storability of Fresh-cut Salicornia herbacea Classified by Size (저장온도와 기능성 필름의 기체 투과도가 다양한 크기의 퉁퉁마디 신선편이의 저장성에 미치는 영향)

  • Baek, Jun Pill;Lee, Han Jong;Choi, In-Lee;Jung, Hyun Jin;Son, Jin Sung;Kim, Il Seop;Jeong, Cheon Soon;Kang, Ho-Min
    • Journal of Bio-Environment Control
    • /
    • v.22 no.2
    • /
    • pp.175-181
    • /
    • 2013
  • These studies were identified the effect of four types of non-perforated breathable (NPB) packing film and three sizes on storage ability of fresh-cut for ready to eat packaging at $5^{\circ}C$ for 25 days and $10^{\circ}C$ for 15 days storage in Salicornia herbacea. The fresh weight loss was less than 2% in every films at $5^{\circ}C$ condition after 25 days storage, and the $10^{\circ}C$ also had same result on 15 days storage except 100,000 cc NPB film. Compare with storage after 15 days, storage condition at $5^{\circ}C$ had shown better result under the 1% fresh weight loss rate. The 5,000 cc and $5^{\circ}C$ condition had been shown the characteristics of MA packaging in carbon dioxide and oxygen concentrations. The ethylene concentration in vacuum film was higher 10 to 100 times than in NPB film treatments during storage. But ethylene concentration was not statistically significant differences among size treatments. Every conditions had been measured the anti-oxidant activity by DPPH method after storage at $5^{\circ}C$ for 25 days and $10^{\circ}C$ for 15 days. S. herbacea at $5^{\circ}C$ had been more than twice of activity compare with that at $10^{\circ}C$. 100,000 cc NPB film had been higher contents of anti-oxidant activity at $5^{\circ}C$ and $10^{\circ}C$. As the fresh-cut sizes, 3 cm and 5 cm sizes had changed depending on film types but 10 cm were not effected by the film types in the DPPH activity. When panel test had been tried to measure the visual quality and off-flavor after storage, $5^{\circ}C$ with a filme of 5,000 cc treatment had established higher value than other treated conditions. As these results, it's may be suggested that the $5^{\circ}C$ with 5,000 cc non-perforated breathable film for MA storage in Salicornia herbacea at fresh cut distribution system. Fresh cut size 10 cm with 100,000 cc NPB film also had the good quality for 15 dyas storage at $10^{\circ}C$, and this result can be applied for short term distribution system in Korea.

Estimation of $T_2{^*}$ Relaxation Times for the Glandular Tissue and Fat of Breast at 3T MRI System (3테슬러 자기공명영상기기에서 유방의 유선조직과 지방조직의 $T_2{^*}$이완시간 측정)

  • Ryu, Jung Kyu;Oh, Jang-Hoon;Kim, Hyug-Gi;Rhee, Sun Jung;Seo, Mirinae;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Purpose : $T_2{^*}$ relaxation time which includes susceptibility information represents unique feature of tissue. The objective of this study was to investigate $T_2{^*}$ relaxation times of the normal glandular tissue and fat of breast using a 3T MRI system. Materials and Methods: Seven-echo MR Images were acquired from 52 female subjects (age $49{\pm}12 $years; range, 25 to 75) using a three-dimensional (3D) gradient-echo sequence. Echo times were between 2.28 ms to 25.72 ms in 3.91 ms steps. Voxel-based $T_2{^*}$ relaxation times and $R_2{^*}$ relaxation rate maps were calculated by using the linear curve fitting for each subject. The 3D regions-of-interest (ROI) of the normal glandular tissue and fat were drawn on the longest echo-time image to obtain $T_2{^*}$ and $R_2{^*}$ values. Mean values of those parameters were calculated over all subjects. Results: The 3D ROI sizes were $4818{\pm}4679$ voxels and $1455{\pm}785$ voxels for the normal glandular tissue and fat, respectively. The mean $T_2{^*}$ values were $22.40{\pm}5.61ms$ and $36.36{\pm}8.77ms$ for normal glandular tissue and fat, respectively. The mean $R_2{^*}$ values were $0.0524{\pm}0.0134/ms$ and $0.0297{\pm}0.0069/ms$ for the normal glandular tissue and fat, respectively. Conclusion: $T_2{^*}$ and $R_2{^*}$ values were measured from human breast tissues. $T_2{^*}$ of the normal glandular tissue was shorter than that of fat. Measurement of $T_2{^*}$ relaxation time could be important to understand susceptibility effects in the breast cancer and the normal tissue.

Environmental Health Surveillance of Low Birth Weight in Seoul using Air Monitoring and Birth Data (2002년 서울시 대기오염과 출생 자료를 이용한 저체중아 환경보건감시체계 연구)

  • Seo, Ju-Hee;Kim, Ok-Jin;Kim, Byung-Mi;Park, Hye-Sook;Leem, Jong-Han;Hong, Yun-Chul;Kim, Young-Ju;Ha, Eun-Hee
    • Journal of Preventive Medicine and Public Health
    • /
    • v.40 no.5
    • /
    • pp.363-370
    • /
    • 2007
  • Objectives: The principal objective of this study was to determine the relationship between maternal exposure to air pollution and low birth weight and to propose a possible environmental health surveillance system for low birth weight. Methods: We acquired air monitoring data for Seoul from the Ministry of Environment, the meteorological data from the Korean Meteorological Administration, the exposure assessments from the National Institute of Environmental Research, and the birth data from the Korean National Statistical Office between January 1, 2002 and December 31, 2003. The final birth data were limited to singletons within $37{\sim}44$ weeks of gestational age. We defined the Low Birth Weight (LBW) group as infants with birth weights of less than 2500g and calculated the annual LBW rate by district. The air monitoring data were measured for $CO,\;SO_2,\;NO_2,\;and\;PM_{10}$ concentrations at 27 monitoring stations in Seoul. We utilized two models to evaluate the effects of air pollution on low birth weight: the first was the relationship between the annual concentration of air pollution and low birth weight (LBW) by individual and district, and the second involved a GIS exposure model constructed by Arc View 3.1. Results: LBW risk (by Gu, or district) was significantly increased to $1.113(95%\;CI=1.111{\sim}1.116)\;for\;CO,\;1.004(95%\;CI=1.003{\sim}1.005)\;for\;NO_2,\;1.202(95%\;CI=1.199{\sim}1.206\;for\;SO_2,\;and\;1.077(95%\;CI=1.075{\sim}1.078)\;\;for\;PM_{10}$ with each interquartile range change. Personal LBW risk was significantly increased to $1.081(95%\;CI=1.002{\sim}1.166)\;for\;CO,\;1.145(95%\;CI=1.036{\sim}1.267)\;for\;SO_2,\;and\;1.053(95%\;CI=1.002{\sim}1.108)\;for\;PM_{10}$ with each interquartile range change. Personal LBW risk was increased to $1.003(95%\;CI=0.954{\sim}1.055)\;for\;NO_2$, but this was not statistically significant. The air pollution concentrations predicted by GIS positively correlated with the numbers of low birth weights, particularly in highly polluted regions. Conclusions: Environmental health surveillance is a systemic, ongoing collection effort including the analysis of data correlated with environmentally-associated diseases and exposures. In addition. environmental health surveillance allows for a timely dissemination of information to those who require that information in order to take effective action. GIS modeling is crucially important for this purpose, and thus we attempted to develop a GIS-based environmental surveillance system for low birth weight.

Ammonia Volatilization from Coated Urea in Paddy Soil of Direct Seeding Rice Culture (벼 건답직파재배에서 피복요소 시용에 따른 암모니아 휘산)

  • Lee, Dong-Wook;Park, Ki-Do;Park, Chang-Young;Jeon, Weon-Tae;Son, Il-Soo;Park, Sung-Tae;Lee, Suk-Soon;Kang, Ui-Gum
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.38 no.6
    • /
    • pp.328-333
    • /
    • 2005
  • Ammonia volatilization is the major form of nitrogen (N) loss from flooded paddy soils and causes low N use efficiency. The effects of controlled release fertilizer (latex coated urea complex fertilizer, LCU) on reducing N loss by ammonia volatilization was measured comparing with urea in rice culture system of direct seeding on dry soil. In the treatment of urea, $NH_4-N$ concentration in surface water after flooding increased rapidly up to $8-10mg\;L^{-1}$ as affected by topdressing, while in the LCU treatment $NH_4-N$ concentration in surface water was less than $1mg\;L^{-1}$ during rice growing season. Relation of $NH_4-N$ concentration in surface water and ammonia volatilization was significant in urea treatment. The amount of ammonia volatilized from rice paddy of LCU treatment was $2.4-3.0kg\;ha^{-1}$ and the rate of ammonia volatilization from N fertilizer applied was only 2.0-2.3% compared with 5.9-7.9% in urea treatment. Therefore, N loss by ammonia volatilization could be reduced by 72-76% with by LCU compared with urea in rice culture system of direct seeding on dry soil.

Sterilization of Neurospora Crassa by Noncontacted Low Temperature Atmospheric Pressure Surface Discharged Plasma with Dielectric Barrier Structure (유전체장벽 방전구조의 비접촉식 저온 대기압 면방전 플라즈마를 이용한 빵곰팡이의 살균효과)

  • Ryu, Young Hyo;Uhm, Han Sup;Park, Gyung Soon;Choi, Eun Ha
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.2
    • /
    • pp.55-65
    • /
    • 2013
  • Sterilization of Neurospora crassa has been investigated in this research by using a surface air plasma with dielectric barrier discharged (DBD) structure under atmospheric pressure. The sinusoidal alternating current has been used in this experiment with discharge voltage of 1.4~2.3 kV. The phase difference between the voltage and current signals are found to be almost 80 degree due to the capacitive property of dielectric barrier. Temperature on the biomaterials has been minimized by radiating the heat with the air cooling system. It is noted that the substrate temperature remains under 37 degree for plasma exposure time of 10 minutes with operation of cooler system. It is found that the ozone, $O_3$, has been measured to be about 25~30 ppm within 1 cm region and to be about 5 ppm at the 150 cm downstream region away from the suface plasma. It is also noted that the nitric oxide, NO, and nitric dioxide, $NO_2$, are not nearly detected. Germination rate and mitochodrial activity of Neurospora crassa immersed in the deionized water have been found to be drastically decreased as the plasma treatment time and its electrical power are increased in this experiment. Here, the mitochondrial activity has been analyzed by MTT (3-(4,5-dimethy lthiazol-2yl)-2,5-diphenyl-2H-tetrazolium bromide) assay. However, sterilization of Neurospora crassa immersed in the Vogel's minimal media has been found to be low by plasma treatment, which is caused by surrounding background solution. This research shows the sterilization possibility of Neurospora crassa by using the noncontated surface DBD plasma, which is different from the plasma jet. This is mainly attibuted to the reactive species generated by the surface plasma, since they play a major role for inhibition of micobes such as Neurospora crassa.

Surface Exchange of Energy and Carbon Dioxide between the Atmosphere and a Farmland in Haenam, Korea (한국 해남 농경지와 대기간의 에너지와 이산화탄소의 지표 교환)

  • Hee Choon Lee;Jinkyu Hong;Chun-Ho Cho;Byoung-Cheol Choi;Sung-Nam Oh;Joon Kim
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.5 no.2
    • /
    • pp.61-69
    • /
    • 2003
  • Surface energy and $CO_2$ fluxes have been measured over a farmland in Haenam, Korea since July 2002. Eddy covariance technique, which is the only direct flux measurement method, was employed to quantitatively understand the interaction between the farmland ecosystem and the atmospheric boundary layer. Maintenance of eddy covariance system was the main concern during the early stage of measurement to minimize gaps and uncertainties in the dataset. Half-hourly averaged $CO_2$ concentration showed distinct diurnal and seasonal variations, which were closely related to changes in net ecosystem exchange (NEE) of $CO_2$. Daytime maximum $CO_2$ uptake was about -1.0 mg $CO_2$ m$^{-2}$ s$^{-1}$ in August whereas nighttime $CO_2$ release was up to 0.3 mg $CO_2$ m$^{-2}$ s$^{-1}$ during the summer. Both daytime $CO_2$ uptake and nighttime release decreased gradually with season. During the winter season, NEE was from near zero to 0.05 mg $CO_2$ m$^{-2}$ s$^{-1}$ . FK site was a moderate sink of atmospheric $CO_2$ until September with daily NEE of 22 g $CO_2$ m$^{-2}$ d$^{-1}$ . In October, it became a weak source of $CO_2$ with an emission rate of 2 g $CO_2$ m$^{-2}$ d$^{-1}$ . Long-term flux measurements will continue at FK site to further investigate inter-annual variability in NEE. to better understand these exchange mechanism and in-depth analysis, process-level field experiments and intensive short-term intercomparisons are also expected to be followed.

Estimation of Soil Cooling Load in the Root Zone of Greenhouses (온실내 근권부의 지중냉각부하 추정)

  • 남상운
    • Journal of Bio-Environment Control
    • /
    • v.11 no.4
    • /
    • pp.151-156
    • /
    • 2002
  • Root zone cooling, such as soil or nutrient solution cooling, is less expensive than air cooling in the whole greenhouse and is effective in promoting root activity, improving water absorption rate, decreasing plant temperature, and reducing high temperature stress. The heat transfer of a soil cooling system in a plastic greenhouse was analyzed to estimate cooling loads. The thermal conductivity of soil, calculated by measured heat fluxes in the soil, showed the positive correlation with the soil water content. It ranged from 0.83 to 0.96 W.m$^{[-10]}$ .$^{\circ}C$$^{[-10]}$ at 19 to 36% of soil water contents. As the indoor solar radiation increased, the temperature difference between soil surface and indoor air linearly increased. At 300 to 800 W.m$^{-2}$ of indoor solar radiations, the soil surface temperature rose from 3.5 to 7.$0^{\circ}C$ in bare ground and 1.0 to 2.5$^{\circ}C$ under the canopy. Cooling loads in the root zone soil were estimated with solar radiation, soil water content, and temperature difference between air and soil. At 300 to 600 W.m$^{-2}$ of indoor solar radiations and 20 to 40% of soil water contents,46 to 59 W.m$^{-2}$ of soil cooling loads are required to maintain the temperature difference of 1$0^{\circ}C$ between indoor air and root zone soil.

A Study on Mechanical Errors in Cone Beam Computed Tomography(CBCT) System (콘빔 전산화단층촬영(CBCT) 시스템에서 기계적 오류에 관한 연구)

  • Lee, Yi-Seong;Yoo, Eun-Jeong;Kim, Seung-Keun;Choi, Kyoung-Sik;Lee, Jeong-Woo;Suh, Tae-Suk;Kim, Joeng-Koo
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • This study investigated the rate of setup variance by the rotating unbalance of gantry in image-guided radiation therapy. The equipments used linear accelerator(Elekta Synergy TM, UK) and a three-dimensional volume imaging mode(3D Volume View) in cone beam computed tomography(CBCT) system. 2D images obtained by rotating $360^{\circ}$and $180^{\circ}$ were reconstructed to 3D image. Catpan503 phantom and homogeneous phantom were used to measure the setup errors. Ball-bearing phantom was used to check the rotation axis of the CBCT. The volume image from CBCT using Catphan503 phantom and homogeneous phantom were analyzed and compared to images from conventional CT in the six dimensional view(X, Y, Z, Roll, Pitch, and Yaw). The variance ratio of setup error were difference in X 0.6 mm, Y 0.5 mm Z 0.5 mm when the gantry rotated $360^{\circ}$ in orthogonal coordinate. whereas rotated $180^{\circ}$, the error measured 0.9 mm, 0.2 mm, 0.3 mm in X, Y, Z respectively. In the rotating coordinates, the more increased the rotating unbalance, the more raised average ratio of setup errors. The resolution of CBCT images showed 2 level of difference in the table recommended. CBCT had a good agreement compared to each recommended values which is the mechanical safety, geometry accuracy and image quality. The rotating unbalance of gentry vary hardly in orthogonal coordinate. However, in rotating coordinate of gantry exceeded the ${\pm}1^{\circ}$ of recommended value. Therefore, when we do sophisticated radiation therapy six dimensional correction is needed.