• Title/Summary/Keyword: Measured Rate System

Search Result 2,490, Processing Time 0.035 seconds

Radiopharmceutical Factors in the Prepartion of $^{99m}Tc-HMPAO$ Images of the Brain (뇌스캔용 $^{99m}Tc-HM-PAO$의 방사성 동위원소표지에 영향을 미치는 인자에 대한 연구)

  • Yeom, Mi-Kyoung;Kim, Sang-Eun;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.1
    • /
    • pp.117-121
    • /
    • 1991
  • Technetium-99m-hexamethylpropyleneamine oxime $(^{99m}Tc-HM-PAO)$ is a neutral-lipophilic chelate which is used for scanning cerebral blood flow. The labeling efficiencies of $^{99m}Tc-HM-PAO$ is known to be sensitive to the amount of pertechnetate added and the quality of the pertechnetate. Because of these factors, the manufacture recommends that HM-PAO kits be reconstituted with a maximum of 30 mCi pertechnetate which was eluted <4 hr earlier from a generator which had been eluted < 24 hr previously. So we measured the labelling efficiencies and the decomposition rate constant according to the amount of pertechnetate added, the volume of pertechnette added, and generator in-growth time. We used the 3-system chromatographic methods (paper & ITLC-SG chromatography) which analyzed the labelling efficiencies of the $^{99m}Tc-HM-PAO$. There was no significant difference in labelling efficiencies between variable pertechnetate acitvities added. ($39.9{\pm}4.9\;mCi:\;87.8{\pm}5.1\;(%)$, $60.8{\pm}5.0\;mCi:\;90.7{\pm}2.2\;(%)$, $79.0{\pm}6.0\;mCi:\;86.8{\pm}3.9\;(%)$, $106.6{\pm}11.6\;mCi:\;87.7{\pm}1.2\;(%)$, p>0.05) No significant difference in labelling efficiencies were found between pertechnetate of 4ml and 5ml. (4ml : $89.1{\pm}3.2(%)$, 5ml: $87.3{\pm}4.0(%)$, p>0.05). There was no difference between 1-6 and 10-48 hr of generator in-growth time. (1-6 hr: $87.8{\pm}4.0(%)$, 10-48 hr: $89.6{\pm}1.6(%)$, p>0.05) The mean value of decomposition rate constant was $0.196{\pm}0.097\;(hr^{-1})$, and there were no difference according to the amount of pertecnetate added and the volume of pertecnetate added, ($39.9{\pm}4.9\;mCi:\;0.208{\pm}0.059\;(hr^{-1})$, $60.8{\pm}5.0\;mCi:\;0.191{\pm}0.100\;(hr^{-1})$ $79.0{\pm}6.0\;mCi:\;0.192{\pm}0.118\;(hr^{-1})$, $106.6{\pm}11.6\;mCi:\;0.212{\pm}0.030\;(hr^{-1})$, p>0.05, 4 ml: $0.200{\pm}0.074\;(hr^{-1})$, Sml: $0.193{\pm}0.115\;(hr^{-1})$, p>0.05). In the case of using the first eluate, the labelling efficiency of $^{99m}Tc-HM-PAO$ W3S 82.1%. These data suggest that there were no significant alteration in labelling efficiency of $^{99m}Tc-HM-PAO$ according to the considerable range of pertechnetate activities and volume added, and generator in-growth time. Also, it was shown that one vial of HM-PAO kit supplied the $^{99m}Tc-HM-PAO$ which was used for 3-4 patients.

  • PDF

Monitoring Bacillus cereus and Aerobic Bacteria in Raw Infant Formula and Microbial Quality Control during Manufacturing (영.유아용 식품원료의 Bacillus cereus와 일반세균 모니터링 및 제조공정 중 미생물 품질제어)

  • Jung, Woo-Young;Eom, Joon-Ho;Kim, Byeong-Jo;Ju, In-Sun;Kim, Chang-Soo;Kim, Mi-Ra;Byun, Jung-A;Park, You-Gyoung;Son, Sang-Hyuck;Lee, Eun-Mi;Jung, Rae-Seok;Na, Mi-Ae;Yuk, Dong-Yeon;Gang, Ji-Yeon;Heo, Ok-Sun;Yoon, Min-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.4
    • /
    • pp.494-501
    • /
    • 2010
  • The purpose of this study was to examine the presence of Bacillus cereus, aerobic bacteria and coliforms in the raw material of infant formulas and investigate the manufacturing process in terms of microbial safety. Among ten kinds of raw infant formula material samples (n=20), Bacillus cereus appeared in two (n=4). Aerobic bacteria were not detected in raw infant formula material or maximum 4.15 log CFU/g. Eleven species of aerobic bacteria were isolated and 76% of them were Sphingomonas paucimobilis, Pseudomonas fluorescens, Rhizobium radiobactor, or Stenotrophomonas maltophilia. A Pearson's correlation analysis revealed that the most influential factors for detecting Bacillus cereus were aerobic bacteria and coliforms. In other words, when the measured values of aerobic bacteria and coliforms were higher, the possibility that Bacillus cereus would appear increased. In a regression model to predict Bacillus cereus, the rate of appearance was correlated with aerobic bacteria and coliforms, and its contribution rate for effectiveness was 86%. Improving microbial quality control by pasteurization, spray dry, popping and extrusion resulted in a decrease in the numbers of Bacillus cereus, aerobic bacteria and coliforms in the raw materials. The results suggest that a hazard analysis and critical control point system might be effective for reducing microbiological contamination.

Earth Pressure on the Braced Wall in the Composite Ground Depending on the Depth and the Joint Dips of the Base Rocks under the Soil Strata (복합지반 굴착 시 기반암의 깊이와 절리경사에 따라 흙막이벽체에 작용하는 토압)

  • Bae, Sang Su;Lee, Sang Duk
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.10
    • /
    • pp.41-53
    • /
    • 2016
  • Stability of the braced earth wall in the composite ground, which is composed of the jointed base rocks and the soil strata depends on the earth pressure acting on it. In most cases, the earth pressure is calculated by the empirical method, in which base rocks are considered as a soil strata with the shear strength parameters of base rocks. In this case the effect of the joint dips of the jointed base rocks is ignored. Therefore, the calculated earth pressure is smaller than the actual earth pressure. In this study, the magnitude and the distribution of the earth pressure acting on the braced wall in the composite ground depending on the joint dips of the base rocks and the ratio of soil strata and base rocks were experimentally studied. Two dimensional large-scale model tests were conducted in a large scale test facility (height 3.0 m, length 3.0 m and width 0.5 m) by installing 10 supports in a scale of 1/14.5. The test ground was presumed with the base rock ratio of the composite ground of 65%:35% and 50%:50% and with the joint dips for each base rock layer, $0^{\circ}$, $30^{\circ}$, $45^{\circ}$ and $60^{\circ}$, respectively. And then finite element analyses were performed in the same condition. As results, the earth pressure on the braced wall increased as the base rock layer's joint dips became larger. And earth pressure at the rock layer increased as the rock rate became larger. The largest earth pressure was measured when the base rock rate was 50% (R50) and the rock layer's joint dips was $60^{\circ}$. Based on these results, a formular for the calculation of the earth pressure in the composite ground could be suggested. Distribution of earth pressure was idealized in a quadrangular form, in which the magnitude and the position of peak earth pressure depended on the rock ratio and the joint dips.

Development of Quality Assurance Software for $PRESAGE^{REU}$ Gel Dosimetry ($PRESAGE^{REU}$ 겔 선량계의 분석 및 정도 관리 도구 개발)

  • Cho, Woong;Lee, Jaegi;Kim, Hyun Suk;Wu, Hong-Gyun
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.233-241
    • /
    • 2014
  • The aim of this study is to develop a new software tool for 3D dose verification using $PRESAGE^{REU}$ Gel dosimeter. The tool included following functions: importing 3D doses from treatment planning systems (TPS), importing 3D optical density (OD), converting ODs to doses, 3D registration between two volumetric data by translational and rotational transformations, and evaluation with 3D gamma index. To acquire correlation between ODs and doses, CT images of a $PRESAGE^{REU}$ Gel with cylindrical shape was acquired, and a volumetric modulated arc therapy (VMAT) plan was designed to give radiation doses from 1 Gy to 6 Gy to six disk-shaped virtual targets along z-axis. After the VMAT plan was delivered to the targets, 3D OD data were reconstructed from 512 projection data from $Vista^{TM}$ optical CT scanner (Modus Medical Devices Inc, Canada) per every 2 hours after irradiation. A curve for converting ODs to doses was derived by comparing TPS dose profile to OD profile along z-axis, and the 3D OD data were converted to the absorbed doses using the curve. Supra-linearity was observed between doses and ODs, and the ODs were decayed about 60% per 24 hours depending on their magnitudes. Measured doses from the $PRESAGE^{REU}$ Gel were well agreed with the TPS doses at central region, but large under-doses were observed at peripheral region at the cylindrical geometry. Gamma passing rate for 3D doses was 70.36% under the gamma criteria of 3% of dose difference and 3 mm of distance to agreement. The low passing rate was resulted from the mismatching of the refractive index between the PRESAGE gel and oil bath in the optical CT scanner. In conclusion, the developed software was useful for 3D dose verification from PRESAGE gel dosimetry, but further improvement of the Gel dosimetry system were required.

Dental Hygienist-Led Dental Hygiene Process of Care for Self-Support Program Participants in Gangneung (강릉시 자활근로사업 참여자 대상 치위생 과정 사례보고)

  • Yoo, Sang-Hee;Kwak, Seon-Hui;Lee, Sue-Hyang;Song, Ga-In;Bae, Soo-Myoung;Shin, Sun-Jung;Shin, Bo-Mi
    • Journal of dental hygiene science
    • /
    • v.18 no.6
    • /
    • pp.327-339
    • /
    • 2018
  • This study aimed to provide basic data for establishing the clinical basis for dental hygienist-led dental hygiene process of care by identifying multiple risk factors for self-support program participants in Gangneung city; we also compared oral health status and behavioral changes through customized oral health care. Four dental hygienists who were evaluated for degree of conformity provided dental hygiene process of care to eight self-support program participants who were selected as having an oral health risk among people in the self-support center. The clinical indicators measured during dental hygiene assessment and evaluation and behavioral changes due to dental hygiene intervention were compared and analyzed. With respect to clinical indicators, at the time of probe, the retention rate of patients with gingival bleeding decreased from 61.4% to 14.7% after intervention (p=0.004). Furthermore, the retention rate of patients with a periodontal pocket >4 mm decreased from 15.6% to 5.8% (p=0.001). The average modified O'Leary index of the patients improved from 23 to 40 (p=0.002). Previously, all eight subjects used the vertical or horizontal method of brushing; after dental hygiene care interventions regarding method and frequency of toothbrushing, use of oral care products, and individual interventions, they started using the rolling or Bass method of toothbrushing. Four of eight subjects reported using interdental toothbrushes after intervention. As a result of applying the change model to the transtheoretical behavior change of the subject, the result of strengthening the health behavior was confirmed. For promotion of oral health by the prevention-centered incremental oral health care system, dental hygienist-led dental hygiene management and maintenance is essential. It is thought that continuous research, such as for feasibility evaluation, cost benefit analysis, and preparation of legal systems, is needed to establish and activate dental hygiene management.

Effect of Difference in Irrigation Amount on Growth and Yield of Tomato Plant in Long-term Cultivation of Hydroponics (장기 수경재배에서 급액량의 차이가 토마토 생육과 수량 특성에 미치는 영향)

  • Choi, Gyeong Lee;Lim, Mi Young;Kim, So Hui;Rho, Mi Young
    • Journal of Bio-Environment Control
    • /
    • v.31 no.4
    • /
    • pp.444-451
    • /
    • 2022
  • Recently, long-term cultivation is becoming more common with the increase in tomato hydroponics. In hydroponics, it is very important to supply an appropriate nutrient solution considering the nutrient and moisture requirements of crops, in terms of productivity, resource use, and environmental conservation. Since seasonal environmental changes appear severely in long-term cultivation, it is so critical to manage irrigation control considering these changes. Therefore, this study was carried out to investigate the effect of irrigation volume on growth and yield in tomato long-term cultivation using coir substrate. The irrigation volume was adjusted at 4 levels (high, medium high, medium low and low) by different irrigation frequency. Irrigation scheduling (frequency) was controlled based on solar radiation which measured by radiation sensor installed outside the greenhouse and performed whenever accumulated solar radiation energy reached set value. Set value of integrated solar radiation was changed by the growing season. The results revealed that the higher irrigation volume caused the higher drainage rate, which could prevent the EC of drainage from rising excessively. As the cultivation period elapsed, the EC of the drainage increased. And the lower irrigation volume supplied, the more the increase in EC of the drainage. Plant length was shorter in the low irrigation volume treatment compared to the other treatments. But irrigation volume did not affect the number of nodes and fruit clusters. The number of fruit settings was not significantly affected by the irrigation volume in general, but high irrigation volume significantly decreased fruit setting and yield of the 12-15th cluster developed during low temperature period. Blossom-end rot occurred early with a high incidence rate in the low irrigation volume treatment group. The highest weight fruits was obtained from the high irrigation treatment group, while the medium high treatment group had the highest total yield. As a result of the experiment, it could be confirmed the effect of irrigation amount on the nutrient and moisture stabilization in the root zone and yield, in addition to the importance of proper irrigation control when cultivating tomato plants hydroponically using coir substrate. Therefore, it is necessary to continue the research on this topic, as it is judged that the precise irrigation control algorithm based on root zone-information applied to the integrated environmental control system, will contribute to the improvement of crop productivity as well as the development of hydroponics control techniques.

Usefulness of Troponin-I, Lactate, C-reactive protein as a Prognostic Markers in Critically Ill Non-cardiac Patients (비 순환기계 중환자의 예후 인자로서의 Troponin-I, Lactate, C-reactive protein의 유용성)

  • Cho, Yu Ji;Ham, Hyeon Seok;Kim, Hwi Jong;Kim, Ho Cheol;Lee, Jong Deok;Hwang, Young Sil
    • Tuberculosis and Respiratory Diseases
    • /
    • v.58 no.6
    • /
    • pp.562-569
    • /
    • 2005
  • Background : The severity scoring system is useful for predicting the outcome of critically ill patients. However, the system is quite complicated and cost-ineffective. Simple serologic markers have been proposed to predict the outcome, which include troponin-I, lactate and C-reactive protein(CRP). The aim of this study was to evaluate the prognostic values of troponin-I, lactate and CRP in critically ill non-cardiac patients. Methods : From September 2003 to June 2004, 139 patients(Age: $63.3{\pm}14.7$, M:F = 88:51), who were admitted to the MICU with non-cardiac critical illness at Gyeongsang National University Hospital, were enrolled in this study. This study evaluated the severity of the illness and the multi-organ failure score (Acute Physiologic and Chronic Health EvaluationII, Simplified Acute Physiologic ScoreII and Sequential Organ Failure Assessment) and measured the troponin-I, lactate and CRP within 24 hours after admission in the MICU. Each value in the survivors and non-survivors was compared at the 10th and 30th day after ICU admission. The mortality rate was compared at 10th and 30th day in normal and abnormal group. In addition, the correlations between each value and the severity score were assessed. Results : There were significantly higher troponin-I and CRP levels, not lactate, in the non-survivors than in the survivors at 10th day($1.018{\pm}2.58ng/ml$, $98.48{\pm}69.24mg/L$ vs. $4.208{\pm}10.23ng/ml$, $137.69{\pm}70.18mg/L$) (p<0.05). There were significantly higher troponin-I, lactate and CRP levels in the non-survivors than in the survivors on the 30th day ($0.99{\pm}2.66ng/ml$, $8.02{\pm}9.54ng/dl$, $96.87{\pm}68.83mg/L$ vs. $3.36{\pm}8.74ng/ml$, $15.42{\pm}20.57ng/dl$, $131.28{\pm}71.23mg/L$) (p<0.05). The mortality rate was significantly higher in the abnormal group of troponin-I, lactate and CRP than in the normal group of troponin-I, lactate and CRP at 10th day(28.1%, 31.6%, 18.9% vs. 11.0%, 15.8 %, 0%) and 30th day(38.6%, 47.4%, 25.8% vs. 15.9%, 21.7%, 14.3%) (p<0.05). Troponin-I and lactate were significantly correlated with the SAPS II score($r^2=0.254$, 0.365, p<0.05). Conclusion : Measuring the troponin-I, lactate and CRP levels upon admission may be useful for predicting the outcome of critically ill non-cardiac patients.

Comparison of Sleep Patterns and Autonomic Nervous System Activity among Three Shifts in Shiftworkers (교대근무자에서 각 교대근무간의 수면양상 및 자율신경계 활성도 비교)

  • Yoon, In-Young;Ha, Mi-Na;Park, Jung-Sun;Song, Byoung-Gun
    • Sleep Medicine and Psychophysiology
    • /
    • v.7 no.2
    • /
    • pp.96-101
    • /
    • 2000
  • Objectives: Through comparing sleep variables and autonomic activities among three shifts in shift workers, the authors intended to clarify which shift is most tolerable and to identify the characteristics of their psychological and physical problems. This study is also expected to help shift workers to adapt themselves to their work more effectively. Methods: Fifty one shift workers took part in this study. They were working in a rapidly rotating system in which they worked for 3 days in one shift with one day off between each shift. Based on a sleep diary, sleep latency (SL), sleep period time (SPT), and number of wake after sleep onset (NWASO) were estimated and compared among the three shifts. In assessing sleepiness, Epworth sleepiness scale (ESS) and visual analogue scale (VAS) were used. To evaluate mood states among the three shifts, profile of mood states (POMS) was administered. Heart rate variability (HRV), and the level of adrenaline and noradrenaline were measured to assess autonomic activities. HRV included low frequency power (LF), high frequency power (HF), and LF/HF. Results: SPT was significantly lengthened during the evening shift and SL was shortened during the night shift. The workers showed a drop in alertness at wake-up during morning shift and a drop in alertness at work during night shift. During night shift the subjects complained of physical fatigue and cognitive decline. Comparison of HRV showed that parasympathetic activity was most prominent during the evening shift. Secretion of adrenaline and noradrenaline decreased during the evening shift, though statistically not significant. Conclusion: We found that the evening shift was most tolerable among the three shifts. It is recommended that morning light exposure be done during the morning shift and nocturnal light exposure during the night shift.

  • PDF

A study on the accuracy of source position in HDR brachytherapy according to the curvature of Universal applicator transfer tube and applicator type (원격 후 장전치료기를 사용한 고선량률 근접치료시 기구의 형태와 선원 전달 도관의 곡률 변화에 따른 선원위치 정확성에 관한 고찰)

  • Shin, Hyeon Kyung;Lee, Sang Kyoo;Kim, Joo Ho;Cho, Jeong Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.123-129
    • /
    • 2015
  • Purpose : The goal of this study was to verify and analyze the source position according to the curvature of the universal applicator and 4 different angle applicators when using RALS(Remote After Loading System). Materials and Methods : An interval of 1 cm and 15 second dwell times in each source position were applied for plan. To verify the accuracy of source position, we narrowed the distance between MultiSource container and GAFCHROMIC$^{(R)}$ EBT3 film by 5 cm, 10 cm, 20 cm so that the universal applicator transfer tube had some curvature. Also 4 applicators(Intrauterine tube: $0^{\circ}$, $15^{\circ}$, $30^{\circ}$, Ovoid tube: $65^{\circ}$) were used in the same condition. The differences between desired and actual source position were measured by using Image J. Results : In case of using 4 different angles of applicator with the straight universal applicator transfer tube, the average error was the lowest for $0^{\circ}$ applicator, greatest for $65^{\circ}$ applicator. However, All average errors were within ${\pm}2mm$ recommended in TG-56. When MultiSource container was moved 5 cm, 10 cm, 20 cm towards the EBT3 film, the average errors were beyond ${\pm}2mm$. The first dwell position was relatively located in accuracy, while the second and third dwells were displaced by an increasing magnitude with increasing curvature of the transfer tube. Furthermore, with increasing the angle of applicators, the error of all other dwell positioning was increased. Conclusion : The results of this study showed that both the curvature of universal applicator transfer tube and the angle of applicators affect the source dwell position. It is recommended that using straight universal applicator transfer tubes is followed in all cases, in order to avoid deviations in the delivered source dwell position. Also, It is advisable to verify the actual dwell position, using video camera quality control tool prior to all treatments.

  • PDF

A Study on the Double-Wall Greenhouse Filled with Styrene Pellets (입자충전형 이중벽 온실에 관한 연구)

  • 이석건;이종원;이현우
    • Journal of Bio-Environment Control
    • /
    • v.4 no.1
    • /
    • pp.59-67
    • /
    • 1995
  • This study was conducted to develope the automatic insulation system which control inside temperature of the greenhouse. For this purpose, the double- wall greenhouse and system which could automatically supply and discharge styrene pellets were constructed and abrasion of the pellets, blower ability, insulating property, transmittance and shading effect were analyzed by the experiments. The results obtained from this study can be summarized as follows : 1. It took an hour and fifteen minutes to supply and discharge about 2㎥ pellets in the experimental greenhouse. However, it is possible to reduce the operation time by proper selection of the blower and exhaust port, and by proper control of the supply and return pipe. 2. It was founded that the indirect delivery way was more profitable than the direct one in the supply and return of pellets. 3. When the transmittance was measured between 10 a.m. and 3 p.m., the average light transmissivity rate was 67%. 4. In winter nighttime, the inside temperature of the double- wall greenhouse with out the pellets was higher than the outside temperature by 3.4$^{\circ}C$ on an average. However, the inside temperature of the double - wall greenhouse with insulated area 73% was higher than the outside by one 6.6$^{\circ}C$ on an average, and the inside temperature of the greenhouse with insulated area 100% was higher than outside one by 13.5$^{\circ}C$ on an average. Therefore, it was proved that the insulating ability of the double - wall greenhouse in nighttime was excellent. 5. When the outside temperature was 36.9$^{\circ}C$ on an average, the inside temperature of the double- wail greenhouse with insulated area 100% was 3$0^{\circ}C$ on an average. As the inside temperature was lower than the outside one by 7$^{\circ}C$ on an average, we could know that the shading effects of the double- wall greenhouse were excellent in summer daytime.

  • PDF