• Title/Summary/Keyword: Measured Rate System

Search Result 2,502, Processing Time 0.041 seconds

3-D Nano Topology Measurement using VCM (VCM(voice coil motor)를 이용한 3차원 나노 형상 측정 시스템)

  • Jung, Jong-Kyu;Youm, Woo-Sub;Park, Kiy-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1439-1443
    • /
    • 2007
  • In this paper, vibration reduction techniques of a voice coil motor (VCM) actuator are presented for AFM imaging system. The damping coefficient of the actuator driven by VCM with a flexure hinge is quite low and it cause the about 30dB peak amplitude response at the resonance frequency. To decrease this peak response, we design and apply elliptical band-stop filters to xy and z axis VCM actuator. Frequency response of each actuator with filter is measured to verify the effect of the filters. As a sensor, capacitive sensor is used. Vibration reduction rate of the xy actuator with the filter is also measured while real AFM scanning condition. As another method, closed loop control with the capacitive sensor is applied to the xy axis actuator to add an electrical damping effect and vibration reduction rate measured. These vibration reduction rates with each method are compared. In the case of z axis actuator, the frequency response of force (gap) control loop is measured. For comparison, the frequency response using a conventional PID controller is also obtained. Finally, the AFM image of a standard grid sample is measured with the designed controller to analyze the effect in the AFM imaging.

  • PDF

Nonlinear Adaptive Control of Fermentation Process in Stirred Tank Bioreactor

  • Kim, Hak-Kyeong;Nguyen, Tan-Tien;Nam soo Jeong;Kim, Sang-Bong
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.4 no.4
    • /
    • pp.277-282
    • /
    • 2002
  • This paper proposes a nonlinear adaptive controller based on back-stepping method for tracking reference substrate concentration by manipulating dilution rate in a continuous baker's yeast cultivating process in stirred tank bioreactor. Control law is obtained from Lyapunov control function to ensure asymptotical stability of the system. The Haldane model for the specific growth rate depending on only substrate concentration is used in this paper. Due to the uncertainty of specific growth rate, it has been modified as a function including the unknown parameter with known bounded values. The substrate concentration in the bioreactor and feed line are measured. The deviation from the reference is observed when the external disturbance such as the change of the feed is introduced to the system. The effectiveness of the proposed controller is shown through simulation results in continuous system.

Simulation of Spray Behaviors by Injection Rate Shapes in Diesel Injection System (분사율 형상에 따른 디젤분사계의 분무거동에 관한 시뮬레이션)

  • Wang, W.K.;Jang, S.H.;Koh, D.K.;Ahn, S.K.
    • Journal of Power System Engineering
    • /
    • v.3 no.3
    • /
    • pp.36-43
    • /
    • 1999
  • Many of thermodynamic-based diesel combustion simulations incorporated a model of fuel spray which attempts to describe how the spray develops according to time. Because the spray geometry is an essential aspect of the fuel-air mixing process, it is necessary to be calculated quantitatively for the purpose of heat release and emission analysis. In this paper, we proposed the calculating method of non-evaporation spray behaviors by injection rate shapes under actual operating conditions of diesel engine. We confirmed the utility of this calculating model as the calculated results were compared with the measured results. This calculating program can be applied usefully to study on the diesel spray behavior.

  • PDF

A Study on the design of separation force measuring system for improvement of semiconductor productivity

  • Park, Kun-Jong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.10
    • /
    • pp.1-7
    • /
    • 2017
  • In this paper, the separation force measuring system is developed. The separation force aries due to adhesive strength between semiconductor epoxy molding compound(EMC) and the metal plate in semiconductor formed plate. In general, when removing the metal plate in semiconductor formed plate from semiconductor epoxy molding compound, excessive strength can result in a increase in semiconductor defect rates, or conversely, if too little force is exerted on the metal plate in semiconductor formed plate, the semiconductor production rates can decrease. In this study, the design criteria for the selection of the AC servo motor, the role of the ball screw, the relationship between the load cell and the ball screw, and the rate of deceleration are given. In addition, minimizing the reject rate of semiconductors and maximizing the semiconductor production rate are achieved through the standardization of the collected separation force data measured by the proposed system.

Analysis of Air Flow Rate through Subway Vent Shaft with Mechanical Ventilation System for Shape Change of Vent Shaft

  • Kim, Jung-Yup
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.17 no.2
    • /
    • pp.45-51
    • /
    • 2009
  • Three-dimensional numerical analyses of mechanical ventilation system in vent shaft of subway in operation are carried out in relation with the different air flow passage of vent shaft and two ventilation operation modes of push/pull, The ventilation characteristics of vent shaft with regard to the shape change are evaluated. And the air flow rate through the vent shaft by ventilation system is measured within subway in operation to assess the accuracy and applicability of the numerical analysis method. The decrease of air flow rate due to vent-shaft change are between 0.7 to 2.2% in the cases examined.

The Relationship between Hypertension and Central Serotonergic Nervous System Activity in Spontaneously Hypertensive Rats

  • Kim, Sung-Jin;Ko, Kwang-Ho
    • Archives of Pharmacal Research
    • /
    • v.11 no.4
    • /
    • pp.301-307
    • /
    • 1988
  • Relationship between the maintenance of hypertension and central serotonergic nervous system activity in opontaneously hypertensive rats (SHR) was studied. Serotonin turnover-rates were measured in 5 brain areas as an index of serotonergic neuronal activity and compared at the ages of 14 weeks in two types of animals; (1) spontaneously hypertensive rats (SHR) (2) normotensive wistar kyoto rats (WKY). In 14-week old SHR, central serotonin turnover rate was significantly lower in telencephalon, hypothalamus/thalamus and midbrain than normotensive rat, but significantly higher in cerebellum. There were no significant differences between serotonin turnover rate in pons/medulla of SHR and that of normotensive rat. THese data suggest that the abnormally lower turnover rates of serotonin in telencephalon, hypothalamus/thalamus and midbrain may be one of the underlying neuronal factors for manifestation of hypertension in SHR.

  • PDF

Development of Flow Control Valves for Hot Water Distribution Manifolds (온수분배기용 유량제어밸브의 개발)

  • Kwon, Woo-Chul;Yoon, Joon-Yong;Yoo, Sun-Hak
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.4
    • /
    • pp.11-17
    • /
    • 2010
  • The developed control valves, installed on the hot water distribution manifolds for the floor heating system, consist of the balancing valves and the shut-off valves. The balancing valve was designed to improve the flow control performance and to reduce the noise emitted from the valve by modification of the general V port. The port of the shut-off valve was designed with two ceramic plates, working by rotating upper plate, to improve the duration and to reduce the noise. For the evaluation of the new valves, the flow rate was measured and noise level test was carried out. The test results showed that the error of the flow rate accuracy test for the flow balance of each manifold circuit was less than ${\pm}3%$ and the noise level was less than 35 dB(A).

A Study on the Characteristics of Flow through a Valve using Exhaust System Engine Simulator (기관 배기계 모의실험장치를 이용한 밸브를 통과하는 유동특성에 관한 연구)

  • 차경옥
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.2
    • /
    • pp.124-130
    • /
    • 1999
  • Flow characteristics of a compressible gas flow through a rotating disc-type rotary valve are investigated experimentally under various conditions. It is known that the mass flow rate through poppet valves of 4-stroke cycle engines and through piston valves of 2-stoke cycle engines decrease with increase in engine speed. Rotary valve is one means by which air may be made to flow inter-mittently through a pipe. In this paper an exhaust system simulator of engine was used to experi-mentally analyze the decrease in flow rate at high rotation speeds and to determine what variables other than rotational speed give rise to the observed behaviour. These variables have been included in an empirical equation which is representative of the measured flow characteristics.

  • PDF

Characteristic Measurement for Ready-Deployed Optical Cable and Simulation for SDH and WDM System Existing Conditions (기포설된 광케이블 특성측정과 이 선로조건에 대한 SDH 및 DWDM 광전송장치 전송특성측정과 시뮬레이션)

  • 이성원;김영범
    • Journal of Applied Reliability
    • /
    • v.1 no.2
    • /
    • pp.121-138
    • /
    • 2001
  • Due to large demand for high speed and great capacity for data transfer, WDM, which uses the wavelength division multiplexing technique, is known as alternative way to satisfy those demand for its flexible network operation and management, easy network expansion with existing networks, and enhancement of efficient data transfer rate. For these reasons, a new high capacity WDM optical communication network plan was established. Therefore, the quality of currently deployed optical cables with 81.6 km in length should be assessed to ensure if high capacity WDM system could be implemented on existing optical cables. Two important characteristic parameters, Transfer Loss and PMD (Polarization Mode Dispersion), were measured to evaluate quality of existing optical cable. Transfer Loss was measured at 0.244 dB per kilometer, which is lower than the design standard value at 0.275 dB/km. The measured PMD value gave at 0.030ps/km, and it, therefore, satisfies the value recommended by ITU-T (International Telecommunication Union-T) of 0.5ps/km. In addition, the transfer characteristic for existing 2.5 Gbps and 10 Gbps system were measured and evaluated, and the results showed that error-free transfer is very much feasible. Computer simulation for DWDM system, which is likely be a future backbone network in Korea, to assess the transfer characteristic using the same condition employed for 2.5 Gbps and 10 Gbps was carried out as well. The simulation verified that a stable network operation and reliable service could be provided.

  • PDF

Prediction of a Flushing Rate in an Embayment System for Construction of an Environmentally Sound Harbor (환경친화적 항만건설을 위한 항내 희석률 예측)

  • Jeong, Mi-Hoon;Park, Seok-Soon
    • Journal of Environmental Impact Assessment
    • /
    • v.9 no.3
    • /
    • pp.215-228
    • /
    • 2000
  • This paper presents a novel method to predict a flushing rate in an embayment system, which can be utilized to assess an environmental impact caused by harbor construction. The method was successfully applied to the Ulsan-Onsan coastal area. The flushing rate was computed on the basis of water quality changes predicted by US Army Corps of Engineers' RMA-2/RMA-4 models. After calibration and verification to the measured tidal elevation and current velocity, the model was used to estimate the flushing rate in the proposed harbor. The water quality was simulated for 96 hours and the flushing rate was computed. The results indicated that the proposed harbor would significantly reduce the flushing rate in the Onsan harbor, especially at the small embayment area near the south breakwater. The flushing rate was evaluated for several alternatives, of which the tidal flow channel of 1,000 $m^2$ in the south pier appeared to be the best mitigation measure. This study proposes that the prediction of flushing rate would be a novel method to assess a water quality impact caused by harbor construction.

  • PDF