• Title/Summary/Keyword: Measured Pattern

Search Result 3,389, Processing Time 0.033 seconds

The Effects of Kinesio Taping application on the Pain, Weight-Bearing Distribution, and Walking Ability of Knee Osteoarthritis A Randomized Controlled Trial

  • Kim, Yang Rae;Park, Yong Nam
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.9 no.3
    • /
    • pp.1537-1542
    • /
    • 2018
  • This study aimed to identify the effects of kinesio taping (KT) applied in a proprioceptive neuromuscular facilitation (PNF) pattern on the pain, weight-bearing distribution (WBD), and walking ability of knee osteoarthritis (KOA) patients. Thirty women with KOA were randomly allocated to a control group (n=15) with KT at the quadriceps only, and a PNF pattern group (n=15) with KT at the quadriceps and gastrocnemius muscle. Pain intensity was measured using a visual analogue scale during walking. In addition, WBD, and walking ability were measured before and 30 minutes after KT application. The VAS significantly reduced in both groups after the intervention (p<.05). WBD (p<.05, ES=.32) and walking ability (p<.05, ES=.38) showed a significant change in the PNF pattern group, and in the inter-group comparison, the PNF pattern group showed a significant difference compared to the control groups. These results demonstrate that KT application with PNF pattern effectively attenuate the pain and improves WBD and walking ability in KOA patients.

Analysis of the Correlation between atrophy of exocervical epithelial cell and osteoporosis (자궁경부 상피세포위축과 골다공증의 상관관계 분석)

  • Lee, Dae-Il;Nam, Ha-Gyeong;Lee, Mi-Hwa;Gwak, Min-Jeong;Lee, Hyeon-Jeong;Lee, Su-Bae;Hong, Gwang-Seon
    • Journal of Korea Association of Health Promotion
    • /
    • v.4 no.1
    • /
    • pp.75-84
    • /
    • 2006
  • Background : Osteoporosis and atrophic cell pattern in Pap smear are frequent findings In postmenopausal women due to loss of ovarian function, The present study attempted to find out possible correlation between morphologic characteristics of Pap smear and osteoporosis. Material & methods: The subjects were 825 women(age from 35 to 80) who had undergone Pap smear and bone mineral density(BMD) at The Korea Association of Health Promotion, Seoul Branch, from March 8 to May 10, 2005. Pap smears from 825 women were reviewed and classified either mature cell pattern or atrophic cell pattern by their cytologic patterns, BMD were measured using LUNAR DPX MdIQ(Minster, Ohio, USA). BMD value of lumbar spine(Ll, L2,L3 and L4) were measured from 825 women and BMD value of proximal region off emur(neck NK, Wards triangle WT, and trochanter TR) were measured from 818 women and their bone status were classified as normal( T-sore:>-1.0), osteopenia (T-score: -l~<-2,5) and osteoporosis(T-score: ≤ -2.5). And age distribution of Pap smear, average T-value andfrequency ofsteoporo-sis of each region of the bone, percentage of osteoporosis of each boneregion by age group and changing pattern of percentage of osteopenia and osteoporosis in certain postmenopausal period were compared between mature and atrophic cell pattern. Results: Pap smears revealed total mature cell pattern 53,9%(445/825) and total atrophic cell pattern 46.1%(380/825), Percentage of mature cell pattern decreased from 98.2%(168/171)under 44 age group to 13,3%(17/128) over 65 age group and mature cell pattern increased from 1.8%(3/171) under 44 age group to 86.7%(111/128) oyer 65 age group. Mean T-value of each region of lumbar spine and femur of mature cell pattern were lower than that of atrophic cell pattern about -1,5. And osteoporosis has noted in atrophic cell pattern showing odds ratio Ll 13.9, L2 15.3, L3 12.0, L4 10,4, UK 6.7, WT 10.9 and TR 4.1.Atrophic cell pattern started to increase after 45 years of age and osteoporosis of a trophic cell pattern started after 55 years of age. During 50 to 64 years of age period, L3, L4 and WT revealed parallel increased of osteopenia and osteoporosis and Ll, L2 revealed decreased of osteopenia and increased of osteoporosis. nia Conclusion: Above findings suggest that atrophic cell pattern of Pap smear precedes osteoporosis about 10 years and one of predictor of osteoporosis.

  • PDF

A Study on the Basic Bodice Pattern for the Fatty Body -The subject of middle-aged women- (비만체형을 위한 기본 Bodice 원형연구 -중년기 부인을 중심으로-)

  • 한애미
    • Journal of the Korean Home Economics Association
    • /
    • v.25 no.3
    • /
    • pp.15-26
    • /
    • 1987
  • The purpose of this study was to develop the pattern drafting method which would be suitable to their physical characteristics for the fatty body of 40∼55 aged Korean women who are more than 1.5 Rohrer's Index and 90㎝ bust girth. The study was composed as follows; 1. Body measurement and statistical analysis: One hundred and thirty women were measured on 29 items. Thirty-four items including 29 measured items and 5 calcutated items were analyzed statistically. 1) Mean, standard deviation, variance, maximum, minimum, range were computed. 2) Correlation coefficients between each items were computed. 2. Development of new bodice pattern drafting method: Measurement items necessary to draft new bodice pattern were bust girth, center back waist length, shoulder width, back width, chest and neck base girth. The new pattern was examined through three wearing tests for completion. 3. Evaluation of the new pattern drafting method: The new pattern was objectively evaluated by the sensory test. The sensory evaluation was applied to evaluate the new pattern for the fatty body women by comparint it with the conventional patterns. The results of sensory tests of the new pattern are as follows: 1) The composite reliability coefficient is 0.7698, and the reliability of sensory test shows high. 2) According to a statistical analysis of the result of the 23 items on the questionaire, all the items showed significant differences(α 0.01) between the two, with the new pattern having higher scores. The new pattern is better conventional pattern as the average mark of the former is 3.901 but that of latter is 2.926. The new pattern drafting method proved to be superior to the conventional one especially in the fitness at the center front neck point, shoulder point, side line, armscye depth, position of bust point, chest width line, under arm dart and the shoulder line.

  • PDF

Vibration Measurement Using a Fringe Pattern in Reflective Monochromatic Interferometry

  • Kim, Minsu;Yoon, Do-Young;Pahk, Heuijae
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.5
    • /
    • pp.494-502
    • /
    • 2015
  • This paper introduces methods to measure vibration using a fringe pattern. These methods use variations of a fringe pattern in reflective monochromatic interferometry, without additional components. With the proposed methods we measured the vibrations of four waveform with amplitude 100 nm. When the vibrational amplitude is greater than a quarter wavelength of the light employed, however, the measured results are distorted due to ambiguity. Thus we propose advanced methods to solve this problem, and also measure the vibrations of two waveformswith an amplitude of $1{\mu}m$. To verify the performance of the proposed methods, we compare the results to those from an accelerometer. Multifrequency vibrations of 1, 5, 10, and 20 Hz are measured by both techniques, and the results compared in the frequency domain.

Study on Distance Measurement of Beacon Using Extended Kalman Filter (확장 칼만 필터를 이용한 비콘의 거리 측정에 관한 연구)

  • Jang, Gyuho
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.18 no.3
    • /
    • pp.1-7
    • /
    • 2022
  • In this study, inaccurate RSSI values of beacons are corrected using extended Kalman filter. For the experiment, the beacon was manufactured using Arduino Uno board and HM-10 Bluetooth module. RSSI values according to the distance between beacon and the viewer were measured at intervals of 1m, 1.5m, 2m, 2.5m, 3m, 3.5m, 4m, 4.5m, and 5m. To remove the irregular signal pattern of the beacon, the extended Kalman filter was applied to obtain the average and standard deviation of the actual distance and the measured distance, and it was confirmed that more than 76.6% of the irregular signal pattern was removed after using the extended Kalman filter.In addition, through the smartphone app, it was confirmed that the distance accuracy between the beacon and the measurer was less than the actual distance and the measured distance within 2m, and the standard deviation was small.

Flow Pattern and Pressure Drop of Pure Refrigerants and Their Mixture in Horizontal Tube

  • Lim, Tae-Woo
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.12
    • /
    • pp.2289-2295
    • /
    • 2005
  • Two-Phase flow pattern and pressure drop data were obtained for pure refrigerants R134a and R123 and their mixtures as test fluids in a horizontal tube. The flow pattern is observed through tubular sight glasses located at inlet and outlet of the test section. The flow map of Baker developed for air-water two-phase flow at atmospheric pressure failed to predict the observed flow patterns at the higher value of the mass velocity used in the present study. The map of Kattan et al. predicted the data well over the entire region of mass velocity selected in the present study. The measured pressure drop increased with an increase in vapor quality and mass velocity. A new two-phase multiplier was developed from a dimensional analysis of the frictional pressure drop data measured in the present experiment. This new multiplier was found successfully to correlate the frictional pressure drop.

Measuring Method of In-plane Position Based On Reference Pattern (레퍼런스 패턴 기반 면내 위치 측정 방법)

  • Jung, Kwang Suk
    • Journal of Institute of Convergence Technology
    • /
    • v.2 no.1
    • /
    • pp.43-48
    • /
    • 2012
  • Generally, in-plane position of moving object is measured referring to the reference pattern attached to the object. From optical camera to magnetic reluctance probe, there are many ways detecting a variation of the periodical pattern. In this paper, the various operating principles developed for in-plane positioning are reviewed and compared each other. And, a novel method measuring large rotation as well as x, y linear displacements is suggested, including a detailed description of the overall system layout. It is a modified version of the surface encoder, which is a robust digital measuring method. From the surface encoder, the rotation of an object is measured indirectly through a compensated input of optical servo and independently of linear displacements. So, the operating range can be extended simply by enlarging the reference pattern, without magnifying the decoding units.

  • PDF

A Study on the In-plane Displacement Measurement of Spot welded Joints by Electronic Speckle Pattern Interferometry Method (레이저 스패클 간섭법에 의한 점 용접부의 면내변위 측정에 관한연구)

  • 성백섭
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.48-53
    • /
    • 1997
  • Electronic Speckle Pattern Interferometry(ESPI) using the Model 95 Ar laserm, a video system and an image processor was applied to the in-plane displacement measurements. Unlike traditional strain gauges or moire method, ESPI method requires no special surface preparation or attachments and can be measured in-plane displacement with no contact and real time. In this experiment wpecimen was loaded in parallel with a loadcell. The specimen was the cold rolled sdteel sheet of 2mm thickness, which was attached strain gauges. The study provides an example of how ESPI have been used to measure strain displacement in this specimen. The results measured by ESPI have been used to measure strain displacement in this specimen. The results measured by ESPI have been used to measure strain displacement in this specimen. The results measured by ESPI compare with the data which was measured by strain gauge method in tensile testing.

  • PDF

Relation between Obesity Pattern Identification and Metabolic Parameters in Overweight and Obese Women (과체중 및 비만 여성에서 한방비만변증에 따른 체성분 및 대사관련 지표의 상관성)

  • Song, Miyoung;Kim, Hojun;Lee, Myeong-Jong
    • Journal of Korean Medicine for Obesity Research
    • /
    • v.14 no.1
    • /
    • pp.24-28
    • /
    • 2014
  • Objectives: We conducted this study to analysis obesity pattern and obesity related blood parameters. Methods: A total of 64 overweight and obese (body mass index [BMI] ${\geq}23cm/kg^2$) women who had no other disease was recruited. Body composition and obesity related blood parameters were measured. Also subjects were given and filled out the Obesity pattern identification questionnaire. We analyzed the differences of body composition and blood parameters and measured correlations of BMI and blood parameters in each obesity pattern. Results: The distribution of obesity pattern was liver depression (35.6%), food accumulation (47.5%) and deficiency (pi and yang deficiency, 22.0%), in order. There were no significant differences age, body composition and obesity related blood parameters between obesity patterns. BMI and obesity related blood parameters, however, showed significant correlations depending on obesity patterns. Conclusions: We concluded that correlations between BMI and obesity related blood parameters were differed depending on obesity patterns.

A Study of the Basic Bodice Pattern for Elementary Schoolgirls (학령기 어린이의 Bodice 기본원형에 관한 연구)

  • Lee Sook Nyeu;To Jai Un
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.6 no.2
    • /
    • pp.57-67
    • /
    • 1982
  • The purpose of this study was to improve the clothing life of the children between the nine to twelve by making a scientific and rational basic bodice pattern. The comparison of the eight pattern drafting currently used in Korea was referred in order to make new basic pattern. Three hundred fifty-two subjects from 9 to 12 years old in Seoul area were measured on 19 items. The measurements (24 items including 19 measured items and 5 drafted items that were difficult to measure) were analyzed by mean values and correlation coefficients between each item. This new pattern attempted to set the ease for clothing from experiments of the changes of body surface in motion. On the basis of the above results, a new bodice basic pattern was developed and tested with wearing three times. Through the experiments in measuring the changes of the body surface in motion, it was concluded that it desirable to set a standard of 12cm clothing ease on the bust circumference and 4cm on the waist circumference. The correlation coefficient of the tack width to across back was relatively high (r= .677), therefore, the latter measuring items were eliminated. A grading method was adopted to determine the width and depth of neckline and shoulder slope.

  • PDF