• Title/Summary/Keyword: Measured Frequency

Search Result 7,669, Processing Time 0.035 seconds

THE STUDY ON THE NOISE IN THE VESSEL -Effect of the Noise Control by the Noise Arresting Rooms- (선박소음에 관한 연구 -방음실에 의한 소음제어효과실험-)

  • PARK Jung-Hee
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.9 no.3
    • /
    • pp.215-221
    • /
    • 1976
  • In this study, noise arresting effect of the noise control room from the transmission of surrounding noise was tested when the packing noise control rooms were set up in the test room in which the prerecorded noise from an engine room was reradiated at the same level as the original pressure. The inner space of control room A is $3.389m^3(1.19\times1.19\times2.14m)$ having walls furnished with plywood board 9mm in thickness and noise control room door$(60\times45cm) $ and illumination lamp are placed. In case of the control room B, noise absorption board(10mm fiber board which holds the corntype concavity with diameter of 5mm, depth 5mm, space 15mm) is adhered to the internal ceiling and styrol foam boards(20mm) to the walls. The other struction is same as the control room A. Type C is the same as B except wool board(Glass Fiber, 33mm) on the walls. Type D is same as type A except that the thickness of wall is 12mm and wood pyramid type cone$(5\times5\times13cm)$ is adhered to the ceiling ana walls(Fig. 1). When the recorded noise and vibrated noise were controlled in various levels. The noise pressure which passed through the control rooms was measured by sound level meter(Bruel & Kjar 2205, measuring range 37-140dB). In order to calculate the absorption rate in the control rooms the noise pressure was measured at different distances when the recorded noise pressure was radiated. The followings are the results obtained from the experiment. 1. When the noise pressure of the test room was 60dB, transmission rate of type A was $69.7\%$ and increased $3.3\%$ per 10dB. At the same condition, the rate was $53.9\%$ and increased $4.5\%$ per 10dB in type D. Type D was the most effective in noise arresting of the four and the effect was D,C,B and A in order(Fig.2). 2. When the oscillator sound and vessels noise were radiated in 1,000Hz, at one meter distance to the type A and D, the oscillator sound pressure were 77dB and 73dB, while the vessels noise pressure were 73.3dB and 66.2dB respectivley(Fig.3). 3. Refering to the influence of the frequency to the lower oscillator sound(1,000Hz) pressure, both type C and D were almost same at 140cm but type C was 0.3dB lower than type D at 20cm distance(Fig.4).

  • PDF

The Relationship between the Nurse's Reward Fit and Job Involvement${\cdot}$Organizational Commitment (간호사의 보상적합도와 직무몰입 ${\cdot}$ 조직몰입정도간의 관계 연구)

  • Kim, Jung-A
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.3 no.2
    • /
    • pp.41-59
    • /
    • 1997
  • This study surveyed nurses' value of reward and recognition level of organizational reward, and measured the fit of both. It also looked into the relationship between the reward fit and attitude of nurses toward their job and organization (job involvement${\cdot}$organizational commitment). It was planned to suggest the alternative of a future reward system. The sample consisted of 625 nurses of 8 private University Hospitals. Data for this study was collected from Mar. 25 to Apr. 17 by structured questionnaire. This study examined the differences of nurses' value of reward by their demographic characteristics, and looked into the relationship between the reward fit and job involvement${\cdot}$organizational commitment. Four instruments and a demographic questionnair were used to collect the data. Developed for myself and repaired by panel of judges, the value of reward scale and organizational reward scale consisted of 34 items on five points Likert-type scale. Developed by Kanungo and repaired by panel of judges, the job involvement scale measured overall job involvement on 7 items. The organizational commitment scale was developed by Mowday et al and repaired by panel of judges on 10 items. The data was analyzed by frequency, percentage, ranking, one-way ANOVA, Pearson's correlation coefficient, Chronbach alpha coefficient, t-test, SNK test, factor analysis with SPSS/PC+ progra,.Major findings are as follows 1. The mean of nurses' value of reward is 4.2435 and job content rewards are seen as the most important(M=4.5532). The following orders are seen as follows; financial rewards(M=4.4181), human realtion rewards(M=4.4130), establishment ${\cdot}$ facilities rewards(M=4.1632), professional rewards(M=4.1117), social status or prestige rewards(M=3.9228), career rewards(M=3.8816). Of 34 indivisual reward factors, the retainment allowance is seen to be thought of as the most important thing. 2. The mean of nurses' actual reward is 2.6035. The actual reward responded to the most extremely offered is job content rewards. The following orders are seen as follows ; human relation rewards(M=2.9420), financial rewards(M=2.7682), professional rewards(M=2.4601), social status or prestige rewards(M=2.3696), career rewards(M=2.3466), establishment ${\cdot}$ facilities rewards(M=1.9364). Of 34 indivisual reward factors, medical insurance benefits are felt to be most extremely offered. 3. The mean of fit of reward is -1.6874 and that means actual reward doesn't egual the value of the reward. What is offered mostly to nurses' value of reward is human relation rewards. The following orders are seen as follows; job content rewards(M=-1.5938), career rewards(M=-1.6381), social status of prestige rewards(M=-1.6382), financial rewards(M=-1.6836), professional rewards(M=-1.6854), establishment${\cdot}$facilities rewards(M=-2.3130). Of 34 indivisual factors, the item of fered most closely to nurses' value of reward is seen as the participation in educational programs at the nursing department of the hospital. 4. The mean of nurses' job involvement is 3.1987 and SD is 0.5667. 5. The mean of murses' organizational commitment is 2.9348 and SD is 0.6124, that is seen as a little lower than job involvement. 6. Significant value of reward differences were found among nurses by their demographic characteristics such as married status, tenure, academic career. 7. The fit of reward was significant related to job involvement and organizational commitment. When generalizing the result of this study, the value of reward, which nurses consider important and appropriate offers a reward that corresponds to the nurses' value of reward. This increases nurses' job and organization devotion further, as well as hospital effectiveness. It appears that nurses have recognized that the present reward offered in hospitals doesn't come up to their expectations so I think it is urgent to plan and perform the new reward system which is in accord with the nurses' reward fit.

  • PDF

Fatigue fracture of different dental implant system under cyclic loading (반복하중에 따른 수종 임플란트의 피로파절에 관한 연구)

  • Park, Won-Ju;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.424-434
    • /
    • 2009
  • Statement of problem: Problems such as loosening and fractures of retained screws and fracture of implant fixture have been frequently reported in implant prosthesis. Purpose: Implant has weak mechanical properties against lateral loading compared to vertical occlusal loading, and therefore, stress analysis of implant fixture depending on its material and geometric features is needed. Material and methods: Total 28 of external hexed implants were divided into 7 of 4 groups; Group A (3i, FULL $OSSEOTITE^{(R)}$Implant), Group B (Nobelbiocare, $Br{\aa}nemark$ $System^{(R)}$Mk III Groovy RP), Group C (Neobiotec, $SinusQuick^{TM}$ EB), Group D (Osstem, US-II). The type III gold alloy prostheses were fabricated using adequate UCLA gold abutments. Fixture, abutment screw, and abutment were connected and cross-sectioned vertically. Hardness test was conducted using MXT-$\alpha$. For fatigue fracture test, with MTS 810, the specimens were loaded to the extent of 60-600 N until fracture occurred. The fracture pattern of abutment screw and fixture was observed under scanning electron microscope. A comparative study of stress distribution and fracture area of abutment screw and fixture was carried out through finite element analysis Results: 1. In Vicker's hardness test of abutment screw, the highest value was measured in group A and lowest value was measured in group D. 2. In all implant groups, implant fixture fractures occurred mainly at the 3-4th fixture thread valley where tensile stress was concentrated. When the fatigue life was compared, significant difference was found between the group A, B, C and D (P<.05). 3. The fracture patterns of group B and group D showed complex failure type, a fracture behavior including transverse and longitudinal failure patterns in both fixture and abutment screw. In Group A and C, however, the transverse failure of fixture was only observed. 4. The finite element analysis infers that a fatigue crack started at the fixture surface. Conclusion: The maximum tensile stress was found in the implant fixture at the level of cortical bone. The fatigue fracture occurred when the dead space of implant fixture coincides with jig surface where the maximum tensile stress was generated. To increase implant durability, prevention of surrounding bone resorption is important. However, if the bone resorption progresses to the level of dead space, the frequency of implant fracture would increase. Thus, proper management is needed.

The Levels of Interferon-gamma, Interleukin-2 Receptor, Interleukin-6 and Interleukin-10 in the Patients with Malignant Pleural Effusion, Tuberculosis Effusion, Parapneumonic Effusion, and Lung Emphysema? (악성 흉수, 결핵성 흉수 및 부폐렴 삼출액과 농흉에서 Interferon-gamma, Interleukin-2 Receptor, Interleukin-6, Interleukin-10 농도의 비교)

  • Kim, Myung-Hoon;Kim, Seung-Joon;Park, Yong-Keun;Kim, Seok-Chan;Lee, Sook-Young;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Moon, Hwa-Sik;Song, Jeong-Sup;Park, Sung-Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.5
    • /
    • pp.568-575
    • /
    • 2000
  • Background : Cytokines are chemical mediators that control and modulate many inflammatory processes. They work in different fashions in a variety of diseases. Discriminating between malignant effusion, tuberculous effusion, and parapneumonic effusion are crucial from the clinical view-point in Korea. In the current study, interferon-gamma (IFN-${\gamma}$), soluble interleukin-2 receptor (IL-2R), interleukin-6 (IL-6) and interleukin-10 (IL-10) were measured for this purpose. Methods : Pleural fluids from patients with malignant disease, tuberculosis, parapneumonic effusion and lung empysema were collected and gauged using commercial ELISA kits. Results : 34 patients were enrolled in this study. Among these 15 cases were malignant effusions, 12 were tuberculosis pleurisy and 7 were parapneumonic effusion and lung empyema. The levels of cytokines measured in this study were as follows, in order of frequency, malignant effusion, tuberculous effusion, parapneumonic effusion and lung empyema. The levels of INF-${\gamma}$ were higher in tuberculous effusion than in malignant or parapneumonic effusion ($295.5{\pm}585.5$ vs. $16.7{\pm}50$ vs. $10.0{\pm}0$ pg/ml, p>0.05). The levels of IL-2R were higher in tuberculous effusion than in malignant or parapneumoruc effusion ($7423.5{\pm}3752.8$ vs. $3247.4{\pm}1713.3$ vs. $3790.2{\pm}3201.1$ pg/ml, p<0.05). No significant differences were found in the levels of IL-6 between the groups ($600{\pm}12.8$ pg/ml in malignant effusion, $556.4{\pm}161.7$ pg/ml in tuberculous effusion, $514.4{\pm}224.8$ pg/ml in parapneumoruc effusion). IL-10 levels were higher in parapneumoruc effusion than in malignant or tuberculous effusions ($98.4{\pm}141.7$ vs. $28.2{\pm}55.5$ vs. $11.3{\pm}11.7$ pg/ml, p<0.05). Conclusion : These results suggest that the measurement of IL-2R levels in pleural fluids may be a useful means of differentiating between tuberculous effusion and pleural effusions of other origins, and that the measurement of IL-10 levels in pleural fluids may be useful to differentiate between parapneumonic effusion and pleural effusions of other origins.

  • PDF

BONE DENSITY AND HISTOMORPHOMETRY ASSESSMENT OF DENTAL IMPLANT USING COMPUTERIZED TOMOGRAPHY (컴퓨터 영상을 이용한 임플란트 식립부위의 골밀도와 조직학적 연구)

  • Son, Jang-Ho;Choi, Byung-Hwan;Park, Soo-Won;Cho, Yeong-Cheol;Sung, Iel-Yong;Lee, Ji-Ho;Byun, Ki-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.2
    • /
    • pp.136-142
    • /
    • 2009
  • Bone density in the recipient implant site seems to be an important factor for long term success of endosseous implants. Preoperative evaluation of bone density is very helpful to assist the clinician with the treatment planning of implant therapy. Accurate information on bone density will help the surgeon identify suitable implant sites, thereby improving the success rate of the procedure. Purpose; The aim of this study was to evaluate a correlation between bone density measured preoperatively with computerized tomography and histologically measured bone density by bone biopsy. Patients and methods; Twenty seven patients were selected. All the patients were in good health, with no systemic disorder and additional bone graft. Preoperatively the patients underwent CT scanning to evaluate Houmsfield Unit(HU). Each patients wore a surgical template for implant placement. During surgery 2mm in diameter and 6mm in length specimens were taken. Histomorphometric analysis was performed using digitalized image analysis software Axiovision 4.3. Also, the Resonance frequency analysis(RFA) and insertion torque values were recorded. Results; The highest histomorphometric values was found in the posterior mandible $32.3{\pm}3.8$, followed by $29.9{\pm}2.6$ for the posterior maxilla, $29.4{\pm}2.6$ for the anterior maxilla, $28.6{\pm}2.3$ for the anterior mandible(p=0.214). The hounsfield unit was $989.2{\pm}258.1$ in the posterior mandible, $845.0{\pm}241.5$ in the anterior maxilla, $744.5{\pm}92.6$ in the anterior mandible, $697.3{\pm}136.9$ in the posterior maxilla(p=0.045). This results may suggest that there are strong correlation between the histomorphometric values and hounsfield unit(r=0.760, p<0.05). The RF measurements were $81.9{\pm}2.4$ ISQ in the posterior mandible, $79.0{\pm}1.4$ ISQ in the anterior mandible, $78.3{\pm}4.6$ ISQ in the posterior maxilla, $76.5{\pm}5.0$ ISQ in the anterior maxilla(p=0.048). The insertion torque values was $43.2{\pm}4.2\;Ncm$ in the posterior mandible, $42.0{\pm}0.0\;Ncm$ in the anterior mandible, $41.3{\pm}4.1\;Ncm$ in the posterior maxilla, $40.8{\pm}3.8\;Ncm$ in the anterior maxilla(p=0.612). This results may suggest that there are statistical significance between the hounsfield unit and the insertion torque values(r=0.494, p<0.05), the histomorphometric values and the insertion torque values(r=0.689, p<0.05). But there was no correlation between histomorphometric values and ISQ. There was no statistical significance in age and gender effect on parameters. Conclusions; There was significant correlations between bone density and implant stability parameters. The bone density measurements using preoperative CT may help clinicians to predict primary stability before implant insertion, which is associated with implant survival rates.

On the Observation of Sandstorms and Associated Episodes of Airborne Dustfalls in the East Asian Region in 2005 (2005년 동아시아 지역에서 발생한 모래폭풍과 먼지침전(황사)의 관측)

  • Kim, Hak-Sung;Chung, Yong-Seung
    • Journal of the Korean earth science society
    • /
    • v.30 no.2
    • /
    • pp.196-209
    • /
    • 2009
  • Occurrences of sandstorms in the deserts and loess of Mongolia and northern China and associated dustfall episodes in the Korean Peninsula were monitored during the period January through December, 2005. False colour images were made by directly receiving the NOAA Advanced Very High Resolution Radiometer (AVHRR) data, and the distribution and transport of sandstorms were analyzed. The ground concentrations for PM10, PM2.5 and visibility of the dustfall episodes (PM10 concentration over $190{\mu}g\;m^{-3}$) were analyzed at Cheongwon, located midway in South Korea, and in the leeward direction of the place of origin of the sandstorms. Variations in the concentrations of $O_3,\;NO_2$, CO and $SO_2$ were also compared with dust concentrations in the dustfall episodes. Fewer occurrences of strong sandstorms in the place of origin were observed in 2005, due largely to the accumulation of snow and mild fluctuations of high and low pressure systems in the place of origin, thereby accounting for a low frequency of dustfall episodes in Korea, compared with those during the period 1997-2005. A total of 7 dustfall episodes were monitored in Korea in 2005 that lasted 11 days. In summer, sandstorms occurred less frequently in the source region in 2005 due to high humidity and milder winds, thereby causing no dustfall episodes in Korea. In case the sandstorms occurring at the place of source head directly to Korea without passing through large cities and industrial areas of China, the PM2.5 concentrations were measured at 20% or lower than the PM10 concentrations. However, when the sandstorms headed to Korea via the industrial areas of eastern China, where they pick up anthropogenic air pollutants, the PM2.5 concentrations were at least 25% higher of the PM10 concentrations. On the other hand, over 5 cases were observed and analyzed in 2005 where the PM10 concentrations of sand dust originating from the deserts were measured at $190{\mu}g\;m^{-3}$ or lower, falling short of the level of a dustfall episode.

Estimation of Paddy Rice Growth Parameters Using L, C, X-bands Polarimetric Scatterometer (L, C, X-밴드 다편파 레이더 산란계를 이용한 논 벼 생육인자 추정)

  • Kim, Yi-Hyun;Hong, Suk-Young;Lee, Hoon-Yol
    • Korean Journal of Remote Sensing
    • /
    • v.25 no.1
    • /
    • pp.31-44
    • /
    • 2009
  • The objective of this study was to measure backscattering coefficients of paddy rice using a L-, C-, and X-band scatterometer system with full polarization and various angles during the rice growth period and to relate backscattering coefficients to rice growth parameters. Radar backscattering measurements of paddy rice field using multifrequency (L, C, and X) and full polarization were conducted at an experimental field located in National Academy of Agricultural Science (NAAS), Suwon, Korea. The scatterometer system consists of dual-polarimetric square horn antennas, HP8720D vector network analyzer ($20\;MHz{\sim}20\;GHz$), RF cables, and a personal computer that controls frequency, polarization and data storage. The backscattering coefficients were calculated by applying radar equation for the measured at incidence angles between $20^{\circ}$ and $60^{\circ}$ with $5^{\circ}$ interval for four polarization (HH, VV, HV, VH), respectively. We measured the temporal variations of backscattering coefficients of the rice crop at L-, C-, X-band during a rice growth period. In three bands, VV-polarized backscattering coefficients were higher than hh-polarized backscattering coefficients during rooting stage (mid-June) and HH-polarized backscattering coefficients were higher than VV-, HV/VH-polarized backscattering coefficients after panicle initiation stage (mid-July). Cross polarized backscattering coefficients in X-band increased towards the heading stage (mid-Aug) and thereafter saturated, again increased near the harvesting season. Backscattering coefficients of range at X-band were lower than that of L-, C-band. HH-, VV-polarized ${\sigma}^{\circ}$ steadily increased toward panicle initiation stage and thereafter decreased, and again increased near the harvesting season. We plotted the relationship between backscattering coefficients with L-, C-, X-band and rice growth parameters. Biomass was correlated with L-band hh-polarization at a large incident angle. LAI (Leaf Area Index) was highly correlated with C-band HH- and cross-polarizations. Grain weight was correlated with backscattering coefficients of X-band VV-polarization at a large incidence angle. X-band was sensitive to grain maturity during the post heading stage.

Numerical Analysis of the Grand Circulation Process of Mang-Bang Beach-Centered on the Shoreline Change from 2017. 4. 26 to 2018. 4. 20 (맹방해빈의 일 년에 걸친 대순환과정 수치해석 - 2017.4.26부터 2018.4.20까지의 해안선 변화를 중심으로)

  • Cho, Young Jin;Kim, In Ho;Cho, Yong Jun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.31 no.3
    • /
    • pp.101-114
    • /
    • 2019
  • In this study, we carry out the numerical simulation to trace the yearly shoreline change of Mang-Bang beach, which is suffering from erosion problem. We obtain the basic equation (One Line Model for shoreline) for the numerical simulation by assuming that the amount of shoreline retreat or advance is balanced by the net influx of longshore and cross-shore sediment into the unit discretized shoreline segment. In doing so, the energy flux model for the longshore sediment transport rate is also evoked. For the case of cross sediment transport, the modified Bailard's model (1981) by Cho and Kim (2019) is utilized. At each time step of the numerical simulation, we adjust a closure depth according to pertinent wave conditions based on the Hallermeier's analytical model (1978) having its roots on the Shield's parameter. Numerical results show that from 2017.4.26 to 2017.10.15 during which swells are prevailing, a shoreline advances due to the sustained supply of cross-shore sediment. It is also shown that a shoreline temporarily retreats due to the erosion by the yearly highest waves sequentially occurring from mid-October to the end of October, and is followed by gradual recovery of shoreline as high waves subdue and swells prevail. It is worth mentioning that great yearly circulation of shoreline completes when a shoreline retreats due to the erosion by the higher waves occurring from mid-March to the end of March. The great yearly circulation of shoreline mentioned above can also be found in the measured locations of shoreline on 2017.4.5, 2017.9.7, 2017.11.7, 2018.3.14. However, numerically simulated amount of shoreline retreat or advance is more significant than the physically measured one, and it should be noted that these discrepancies become more substantial for the case of RUN II where a closure depth is sustained to be as in the most morphology models like the Genesis (Hanson and Kraus, 1989).

Effects of vocal aerobic treatment on voice improvement in patients with voice disorders (성대에어로빅치료법이 음성장애환자의 음성개선에 미치는 효과)

  • Park, Jun-Hee;Yoo, Jae-Yeon;Lee, Ha-Na
    • Phonetics and Speech Sciences
    • /
    • v.11 no.3
    • /
    • pp.69-76
    • /
    • 2019
  • This study aimed to investigate the effects of vocal aerobic treatment (VAT) on the improvement of voice in patients with voice disorders. Twenty patients (13 males, 7 females) were diagnosed with voice disorders on the basis of videostroboscopy and voice evaluations. Acoustic evaluation was performed with the Multidimensional voice program (MDVP) and Voice Range Profile (VRP) of Computerized Speech Lab (CSL), and aerodynamic evaluation with PAS (Phonatory Aerodynamic System). The changes in F0, Jitter, Shimmer, and NHR before and after treatment were measured by MDVP. F0 range and Energy range were measured with VRP before and after treatment, and the changes in Expiratory Volume (FVC), Phonation Time (PHOT), Mean Expiratory Airflow (MEAF), Mean Peak Air Pressure (MPAP), and Aerodynamic Efficiency (AEFF) with PAS. Videostroboscopy was performed to evaluate the regularity, symmetry, mucosal wave, and amplitude changes of both vocal cords before and after treatment. Voice therapy was performed once a week for each patient using the VAT program in a holistic voice therapy approach. The average number of treatments per patient was 6.5. In the MDVP, Jitter, Shimmer, and NHR showed statistically significant decreases (p < .001, p < .01, p < .05). VRP results showed that Hz and semitones in the frequency range improved significantly after treatment (p < .01, p < .05), as did PAS, FVC, and PHOT (p < .01, p < .001). The results for videostroboscopy, functional voice disorder, laryngopharyngeal reflux, and benign vocal fold lesions were normal. Thus, the VAT program was found to be effective in improving the acoustic and aerodynamic aspects of the voice of patients with voice disorders. In future studies, the effect of VAT on the same group of voice disorders should be studied. It is also necessary to investigate subjective voice improvement and objective voice improvement. Furthermore, it is necessary to examine the effects of VAT in professional voice users.

The Study on the Embedded Active Device for Ka-Band using the Component Embedding Process (부품 내장 공정을 이용한 5G용 내장형 능동소자에 관한 연구)

  • Jung, Jae-Woong;Park, Se-Hoon;Ryu, Jong-In
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.3
    • /
    • pp.1-7
    • /
    • 2021
  • In this paper, by embedding a bare-die chip-type drive amplifier into the PCB composed of ABF and FR-4, it implements an embedded active device that can be applied in 28 GHz band modules. The ABF has a dielectric constant of 3.2 and a dielectric loss of 0.016. The FR-4 where the drive amplifier is embedded has a dielectric constant of 3.5 and a dielectric loss of 0.02. The proposed embedded module is processed into two structures, and S-parameter properties are confirmed with measurements. The two process structures are an embedding structure of face-up and an embedding structure of face-down. The fabricated module is measured on a designed test board using Taconic's TLY-5A(dielectric constant : 2.17, dielectric loss : 0.0002). The PCB which embedded into the face-down expected better gain performance due to shorter interconnection-line from the RF pad of the Bear-die chip to the pattern of formed layer. But it is verified that the ground at the bottom of the bear-die chip is grounded Through via, resulting in an oscillation. On the other hand, the face-up structure has a stable gain characteristic of more than 10 dB from 25 GHz to 30 GHz, with a gain of 12.32 dB at the center frequency of 28 GHz. The output characteristics of module embedded into the face-up structure are measured using signal generator and spectrum analyzer. When the input power (Pin) of the signal generator was applied from -10 dBm to 20 dBm, the gain compression point (P1dB) of the embedded module was 20.38 dB. Ultimately, the bare-die chip used in this paper was verified through measurement that the oscillation is improved according to the grounding methods when embedding in a PCB. Thus, the module embedded into the face-up structure will be able to be properly used for communication modules in millimeter wave bands.