• Title/Summary/Keyword: Measured Bio-data

Search Result 312, Processing Time 0.042 seconds

Implementation of Multiple Frequency Bioelectrical Impedance Analysis System for Body Composition Analysis (신체 성분 분석을 위한 다 주파수 생체전기 임피던스 분석 시스템 구현)

  • Kim, Seong-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5403-5408
    • /
    • 2012
  • In this paper, we introduce the multiple frequency bio-electrical impedance analysis method for body composition analysis. And then we implement the multiple frequency bio-electrical impedance analysis system. Overall system consists of: multiple frequency alternating current signal generator contained alternating current signal, phase signal detector, voltage signal detector, micro controller, in-out device(key-pad LCD), conductivity electrodes, system power. We explain the architecture of the system and required theory to implement the system. In order to investigate the clinical significance of the body composition data, compare to the data measured by the expert body composition analyzer which provide high reproduction and precision. Finally, experimental results which are the correlation between the measured data show the very high reproduction performance of the body composition analysis in the proposed system.

Equilibrium Moisture Contents and Thin Layer Drying Equations of Cereal Grains and Mushrooms (II) - for Oak Mushroom (Lentinus erodes) - (곡류 및 버섯류의 평형함수율 및 박층건조방정식에 관한 연구(II) - 표고버섯에 대하여 -)

  • Keum, D. H.;Kim, H.;Hong, N. U.
    • Journal of Biosystems Engineering
    • /
    • v.27 no.3
    • /
    • pp.219-226
    • /
    • 2002
  • Desorption equilibrium moisture contents of oak mushroom were measured by the static method using salt solutions at flour temperature levels of 35$\^{C}$, 45$\^{C}$, 55$\^{C}$ and 6$\^{C}$ and five relative humidity levels in the range from 11.0% to 90.8%. EMC data were fitted to the modified Henderson, Chung-Pfost, modified Halsey and modified Oswin models using nonlinear regression analysis. Drying tests far oak mushroom were conducted in an experimental dryer equipped with air conditioning unit. The drying test were performed in triplicate at flour air temperatures of 35$\^{C}$, 45$\^{C}$, 55$\^{C}$ and 65$\^{C}$ and three relative humidities of 30%, 50% and 70% respectively. Measured moisture ratio data were fitted to the selected four drying models(Lewis, Page, simplified diffusion and Thompson models) using stepwise multiple regression analysis. The results of comparing root mean square errors for EMC models showed that modified Halsey was the best model, and modified Oswin models could be available far oak mushroom. The results of comparing coefficients of determination and root mean square errors of moisture ratio for four drying models showed that Page model were found to fit adequately to all drying test data with a coefficient of determination of 0.9990 and root mean square error of moisture ratio of 0.00739.

Fabrication and Performance Evaluation of Diaphragm-type Actuators using Biocompatible polymer (생체적합형 고분자를 이용한 박막형 이동기의 제작 및 특성평가)

  • Jung, Young-Dae;Jeong, Hae-Do
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1254-1258
    • /
    • 2007
  • Electro-active polymer (EAP), one of the smart materials, is a new alternative offering ultra-precise movements and bio-compatibility. We present the results of the design, fabrication, and performance evaluation of a fabricated diaphragm-type polymer actuator using segmented polyurethane(SPU). This paper illustrates the relationship between the elastic modulus and maximum deflection as a key property of the Maxwell stress effect and also presents the relationship between the dielectric constant and maximum deflection as a key property of the electrostriction effect, especially in polymer actuators using SPU. A diaphragm-type actuator was used to induce an equation of the vertically distributed load by using a fully clamped circular plate as the boundary condition. To verify the equation, the results were compared to the data measured from load cell. In the near future, a low-cost check valves and bio-robot can be applied by its actuators.

  • PDF

Mechanism of Organogel Formation from Mixed-Ligand Silver (I) Carboxylates

  • Kim, Ji-Yeon;Park, Cheol-Hee;Kim, Sang-Ho;Yoon, Sung-Ho;Piao, Longhai
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.9
    • /
    • pp.3267-3273
    • /
    • 2011
  • Ag(I) carboxylate gelators with mixed-ligands were systemically investigated to understand the mechanism of the organic gel formation. The gelators constructed 3-D networks of nanometer-sized thin fibers which facilitated gel formation in various aromatic organic solvents, even at very low concentrations. The loss of reflection peaks in the X-ray diffraction data indicated the reduction of strong interactions between the long alkyl chains as the Ag(I) carboxylates formed gels by maximizing their interactions with the organic solvents. The gelation temperature ($T_{gel}$) was measured to explore the interaction between the gelator molecules and solvents depending on their composition and concentration. Based on the gelation phenomena, a dissociation/re-association mechanism was proposed.

Development of an environment field monitoring system to measure crop growth

  • Kim, Yeon-Soo;Kim, Du-Han;Chung, Sun-Ok;Choi, Chang-Hyun;Choi, Tae-Hyun;Kim, Yong-Joo
    • Korean Journal of Agricultural Science
    • /
    • v.46 no.1
    • /
    • pp.57-65
    • /
    • 2019
  • The purpose of this study was to develop an environment field monitoring system to measure crop growth. The environment field monitoring system consisted of sensors, a data acquisition system, and GPS. The sensors used in the environment field monitoring system consisted of an ambient sensor, a soil sensor, and an intensity sensor. The temperature and humidity of the atmosphere were measured with the ambient sensor. The temperature, humidity, and EC of the soil were measured with the soil sensor. The data acquisition system was developed using the Arduino controller. The field monitoring data were collected before a rainy day, on a rainy day, and after the rainy day. The measured data using the environment field monitoring system were compared with the Daejeon regional meteorological office data. The correlation between the data from the environment field monitoring system and the data from the Daejeon regional meteorological office was analyzed for performance evaluation. The correlation of the temperature and humidity of the atmosphere was analyzed because the Daejeon regional meteorological office only provided data for the temperature and humidity of the atmosphere. The correlation coefficients were 0.86 and 0.90, respectively. The result showed a good correlation between the data from the environment field monitoring system and the data from the Daejeon regional meteorological office. Therefore, the developed system could be applied to monitoring the field environment of agricultural crops.

Design of The Patient Monitoring System based on Wearable Device for Multi-biosignal Measurement (다중 생체신호 측정 웨어러블 디바이스 기반 환자 모니터링 시스템 설계)

  • Lee, Minhye;Chung, Gisoo;Jeong, Dongmyong
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.7
    • /
    • pp.103-109
    • /
    • 2017
  • In order to apply the patient monitoring system to the hospital field, it is necessary to be able to measure and analysis data the major bio-signals that are basically covered by the existing patient monitoring system. We have implemented a wearable device and the patient monitoring system for measuring ECG and oxygen saturation. The implemented system transmits the measured bio-signal to the server on the nursing station via Bluetooth. It is represented by graph waveforms and numerical values that can be checked by the medical staff in the patient monitoring system. The validity of this system is verified by comparing the data collected through the designed system with the data obtained from the conventional equipment.

A Position based Kinematic Method for the Analysis of Human Gait

  • Choi Ahn Ryul;Rim Yong Hoon;Kim Youn Soo;Mun Joung Hwan
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.10
    • /
    • pp.1919-1931
    • /
    • 2005
  • Human joint motion can be kinematically described in three planes, typically the frontal, sagittal, and transverse, and related to experimentally measured data. The selection of reference systems is a prerequisite for accurate kinematic analysis and resulting development of the equations of motion. Moreover, the development of analysis techniques for the minimization of errors, due to skin movement or body deformation, during experiments involving human locomotion is a critically important step, without which accurate results in this type of experiment are an impossibility. The traditional kinematic analysis method is the Angular-based method (ABM), which utilizes the Euler angle or the Bryant angle. However, this analysis method tends to increase cumulative errors due to skin movement. Therefore, the objective of this study was to propose a new kinematic analysis method, Position-based method (PBM), which directly applies position displacement data to represent locomotion. The PBM presented here was designed to minimize cumulative errors via considerations of angle changes and translational motion between markers occurring due to skin movements. In order to verify the efficacy and accuracy of the developed PBM, the mean value of joint dislocation at the knee during one gait cycle and the pattern of three dimensional translation motion of the tibiofemoral joint at the knee, in both flexion and extension, were accessed via ABM and via new method, PBM, with a Local Reference system (LRS) and Segmental Reference system (SRS), and then the data were compared between the two techniques. Our results indicate that the proposed PBM resulted in improved accuracy in terms of motion analysis, as compared to ABM, with the LRS and SRS.

Development of a Digital Device for Measuring Soil Physical Properties (I) - Digital Shear Stress Sensor - (토양 물리성 측정을 위한 디지털 장치 개발(I) - 디지털 전단저항 측정장치 -)

  • Park, Jun-Gul;Lee, Kyou-Seung;Cho, Seung-Chan;Lee, Dong-Hoon;Chang, Young-Chang;Noh, Kwang-Mo
    • Journal of Biosystems Engineering
    • /
    • v.33 no.6
    • /
    • pp.416-422
    • /
    • 2008
  • This study was performed to design and construct a digital soil shear stress sensor in order to replace the conventional devices for measuring soil shear property. The developed digital shear stress measuring device can store measured data with GPS position information as a vector format into a computer. Based on the experiments at various field conditions, the measuring characteristic of the device was quite similar to that of a conventional device, SR-2 that has been a major tool to measure the soil shear property. It was concluded that the digital shear stress measuring device was an effective and comprehensive sensor for measuring soil shear property.

The Actin-Related Protein BAF53 Is Essential for Chromosomal Subdomain Integrity

  • Lee, Kiwon;Kim, Ji Hye;Kwon, Hyockman
    • Molecules and Cells
    • /
    • v.38 no.9
    • /
    • pp.789-795
    • /
    • 2015
  • A chromosome territory is composed of chromosomal subdomains. The internal structure of chromosomal subdomains provides a structural framework for many genomic activities such as replication and DNA repair, and thus is key to determining the basis of their mechanisms. However, the internal structure and regulating proteins of a chromosomal subdomain remains elusive. Previously, we showed that the chromosome territory expanded after BAF53 knockdown. Because the integrity of chromosomal subdomains is a deciding factor of the volume of a chromosome territory, we examined here the effect of BAF53 knockdown on chromosomal subdomains. We found that BAF53 knockdown led to the disintegration of histone H2B-GFP-visualized chromosomal subdomains and BrdU-labeled replication foci. In addition, the size of DNA loops measured by the maximum fluorescent halo technique increased and became irregular after BAF53 knockdown, indicating DNA loops were released from the residual nuclear structure. These data can be accounted for by the model that BAF53 is prerequisite for maintaining the structural integrity of chromosomal subdomains.

A portable electronic nose (E-Nose) system using PDA device (개인 휴대 단말기 (PDA)를 기반으로 한 휴대용 E-Nose의 개발)

  • Yang, Yoon-Seok;Kim, Yong-Shin;Ha, Seung-Chul;Kim, Yong-Jun;Cho, Seong-Mok;Pyo, Hyeon-Bong;Choi, Chang-Auck
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.69-77
    • /
    • 2005
  • The electronic nose (e-nose) has been used in food industry and quality controls in plastic packaging. Recently it finds its applications in medical diagnosis, specifically on detection of diabetes, pulmonary or gastrointestinal problem, or infections by examining odors in the breath or tissues with its odor characterizing ability. Moreover, the use of portable e-nose enables the on-site measurements and analysis of vapors without extra gas-sampling units. This is expected to widen the application of the e-nose in various fields including point-of-care-test or e-health. In this study, a PDA-based portable e-nose was developed using micro-machined gas sensor array and miniaturized electronic interfaces. The rich capacities of the PDA in its computing power and various interfaces are expected to provide the rapid and application specific development of the diagnostic devices, and easy connection to other facilities through information technology (IT) infra. For performance verification of the developed portable e-nose system, Six different vapors were measured using the system. Seven different carbon-black polymer composites were used for the sensor array. The results showed the reproducibility of the measured data and the distinguishable patterns between the vapor species. Additionally, the application of two typical pattern recognition algorithms verified the possibility of the automatic vapor recognition from the portable measurements. These validated the portable e-nose based on PDA developed in this study.