• Title/Summary/Keyword: Measure point

Search Result 2,055, Processing Time 0.032 seconds

Polygonal Approximation of Digital Curves to Preserve Original Shapes

  • Lee, Dae-Ho;Lee, Seung-Gwan
    • ETRI Journal
    • /
    • v.32 no.4
    • /
    • pp.630-633
    • /
    • 2010
  • In this letter, we propose a novel polygonal approximation of digital curves that preserve original shapes. The proposed method first detects break points, which have two different consecutive vectors, and sets an initial dominant point set. The approximation is then performed iteratively by deleting a dominant point using a novel distance, which can measure both the distance and the angle acuteness. The experimental results show that the proposed method can preserve original shapes and is appropriate for various shapes, including slab-sided shapes.

Development of the Measuring System of the Rotational Accuracy of main Spindles (주축의 회전정도 측정시스템의 개발)

  • Sin, Yeong-Jae;Park, Jong-Gwon;Lee, Hu-Sang
    • 한국기계연구소 소보
    • /
    • s.20
    • /
    • pp.21-26
    • /
    • 1990
  • In order to satisfy the industrial requirements to measure the rotational error motion of main spindles and to find out the source of the error motion, some measuring systems were made. Their measuring principle are based on the 3-point roundness measurement. In these measuring systems, the measurements are processed by digital calculation technique and the form error and the rotational error motion of main spindles are spearated. In the present paper, the principle of 3-point metnod is introduced and some application examples are shown.

  • PDF

A Study on Comparison of Acoustic Emission, Ultrasonic Testing and Crack Gauge Method in 3-point Bending Testing (3점 굽힘시험에 있어서 AE, 초음파, 크랙게이지법의 비교연구)

  • Han, E.K.;Kim, K.S.;Park, J.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.10 no.1
    • /
    • pp.65-72
    • /
    • 1990
  • Comparison of acoustic emission, ultrasonic testing and crack gauge in 3-point bending testing have been studied. As the results, COD is indirectly assumed by strain gauge rate and grid pitch width when crack gauge grid is out. Acoustic emission is qualitatively able to measure crack growth by total count but ultrasonic testing has a difficulty in measuring it because of echo height fluctuation according to the change and pressure of UT. probe.

  • PDF

Development of Feature Points Detection Algorithm for Measuring of Pulse Wave Velocity (맥파 전달 속도(PWV) 측정을 위한 특징점 검출 알고리즘 개발)

  • Choi, Jung-Hyeon;Cho, Wook-Hyun;Park, Jun-Ho;Kim, Nam-Hoon;Seong, Hyang-Sook;Cho, Jong-Man
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.343-350
    • /
    • 2011
  • The compliance and stiffness of artery are closely related with disease of arteries. Pulse wave velocity(PWV) in the blood vessel is a basic and common parameter in the hemodynamics of blood pressure and blood flow wave traveling in arteries because the PWV is affected directly by the conditions of blood vessels. However, there is no standardized method to measure the PWV and it is difficult to measure. The conventional PWV measurement has being done by manual calculation of the pulse wave transmission time between coronary arterial proximal and distal points on a strip chart on which the pulse wave and ECG signal are recorded. In this study, a pressure sensor consisting of strain gauges is used to measure the blood pressure of arteries in invasive method and regular ECG electrodes are used to record the ECG signal. The R-peak point of ECG is extracted by using a reference level and time windowing technique and the ascending starting point of blood pressure is determined by using differentiation of the blood pressure signal and time windowing technique. The algorithm proposed in this study, which can measure PWV automatically, shows robust and good results in the extraction of feature points and calculation of PWV.

A study on a local descriptor and entropy-based similarity measure for object recognition system being robust to local illumination change (지역적 밝기 변화에 강인한 물체 인식을 위한 지역 서술자와 엔트로피 기반 유사도 척도에 관한 연구)

  • Yang, Jeong-Eun;Yang, Seung-Yong;Hong, Seok-Keun;Cho, Seok-Je
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.9
    • /
    • pp.1112-1118
    • /
    • 2014
  • In this paper, we propose a local descriptor and a similarity measure that is robust to radiometic variations. The proposed local descriptor is made up Haar wavelet filter and it can contain frequency informations about the feature point and its surrounding pixels in fixed region, and it is able to describe feature point clearly under ununiform illumination condition. And a proposed similarity measure is combined with conventional entropy-based similarity and another similarities that is generated by local descriptor. It can reflect similarities between image regions accurately under radiometic illumination variations. We validate with experimental results on some images and we confirm that the proposed algorithm is more superior than conventional algorithms.

Comparative Analysis of Subsurface Estimation Ability and Applicability Based on Various Geostatistical Model (다양한 지구통계기법의 지하매질 예측능 및 적용성 비교연구)

  • Ahn, Jeongwoo;Jeong, Jina;Park, Eungyu
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.4
    • /
    • pp.31-44
    • /
    • 2014
  • In the present study, a few of recently developed geostatistical models are comparatively studied. The models are two-point statistics based sequential indicator simulation (SISIM) and generalized coupled Markov chain (GCMC), multi-point statistics single normal equation simulation (SNESIM), and object based model of FLUVSIM (fluvial simulation) that predicts structures of target object from the provided geometric information. Out of the models, SNESIM and FLUVSIM require additional information other than conditioning data such as training map and geometry, respectively, which generally claim demanding additional resources. For the comparative studies, three-dimensional fluvial reservoir model is developed considering the genetic information and the samples, as input data for the models, are acquired by mimicking realistic sampling (i.e. random sampling). For SNESIM and FLUVSIM, additional training map and the geometry data are synthesized based on the same information used for the objective model. For the comparisons of the predictabilities of the models, two different measures are employed. In the first measure, the ensemble probability maps of the models are developed from multiple realizations, which are compared in depth to the objective model. In the second measure, the developed realizations are converted to hydrogeologic properties and the groundwater flow simulation results are compared to that of the objective model. From the comparisons, it is found that the predictability of GCMC outperforms the other models in terms of the first measure. On the other hand, in terms of the second measure, the both predictabilities of GCMC and SNESIM are outstanding out of the considered models. The excellences of GCMC model in the comparisons may attribute to the incorporations of directional non-stationarity and the non-linear prediction structure. From the results, it is concluded that the various geostatistical models need to be comprehensively considered and comparatively analyzed for appropriate characterizations.

A Study on Matching Method of Hull Blocks Based on Point Clouds for Error Prediction (선박 블록 정합을 위한 포인트 클라우드 기반의 오차예측 방법에 대한 연구)

  • Li, Runqi;Lee, Kyung-Ho;Lee, Jung-Min;Nam, Byeong-Wook;Kim, Dae-Seok
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.2
    • /
    • pp.123-130
    • /
    • 2016
  • With the development of fast construction mode in shipbuilding market, the demand on accuracy management of hull is becoming higher and higher in shipbuilding industry. In order to enhance production efficiency and reduce manufacturing cycle time in shipbuilding industry, it is important for shipyards to have the accuracy of ship components evaluated efficiently during the whole manufacturing cycle time. In accurate shipbuilding process, block accuracy is the key part, which has significant meaning in shortening the period of shipbuilding process, decreasing cost and improving the quality of ship. The key of block accuracy control is to create a integrate block accuracy controlling system, which makes great sense in implementing comprehensive accuracy controlling, increasing block accuracy, standardization of proceeding of accuracy controlling, realizing "zero-defect transferring" and advancing non-allowance shipbuilding. Generally, managers of accuracy control measure the vital points at section surface of block by using the heavy total station, which is inconvenient and time-consuming for measurement of vital points. In this paper, a new measurement method based on point clouds technique has been proposed. This method is to measure the 3D coordinates values of vital points at section surface of block by using 3D scanner, and then compare the measured point with design point based on ICP algorithm which has an allowable error check process that makes sure that whether or not the error between design point and measured point is within the margin of error.

A Study on Detecting Flaws Using DC Potential Drop Method (직류전위차법을 이용한 결함검출에 관한 연구)

  • Bae, Bong-Guk;Seok, Chang-Seong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.4 s.175
    • /
    • pp.874-880
    • /
    • 2000
  • In this paper, a DC potential drop measurement system was used to find the position of the flaw on a simple thin plate. Four-point probe test was evaluated and used for this study. In the four-point probe test, the more distance between current pins provides the more measurable scope, the less voltage difference, and the more voltage difference rate. In the other hand, the more distance between voltage pins provides the less voltage difference and the less voltage difference rate. An optimized four-point probe was applied to measure the relation between voltage and the relative position of flaw to the probe. The Maxwell 21) simulator was used to analyze the electromagnetic field, and it showed that the analytical result was similar to the experimental result within 11.4% maximum error.

The Development and Evaluation of OMM(On the Machine Measuring) System Using Scanning Probe (Scanning Probe를 이용한 OMM(On the Machine Measuring) 시스템 개발 및 평가)

  • Kim, S.H.;Kim, I.H.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.10
    • /
    • pp.71-77
    • /
    • 1996
  • This paper describes the development of on the machine measuring(OMM) system which can directlry measure the three dimensional machined dimensilnal accuracy using scanning probe in milling machine. Two algolithms, continuous path(CP) measurement using UC program and CAD data assisted point to point(PTP) measurement, were developed regarding specification of scanning probe. The OMM system was contructed to verify the developed system suing the proposed algorithm, and actually measured three kinds of machined TV shadow mask molds. The developed system was evaluated it's repeatability and compared with the current measurement system of CMM(Coording Measuring Machine) in terms of relative accuracy and time reduction and productivity increase.

  • PDF

The Error Source Analysis of Measuring Data of OMM System (OMM 시스템의 측정오차 원인분석 및 대책)

  • 이상준;김선호;김옥현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.73-77
    • /
    • 1997
  • This paper describes the analysis of measuring error of on the machine measuring(OMM) system which can directly measure the three dimensional machined free surface dimension using scanning probe on milling machine. 21 inch TV shadow mask mould was measured using PTP(point to point)measurement algorithm at pallet clamped and unclamped state on OMM system, and using coordinate measuring machine(CMM) one after another. The OMM system was evaluated probe error, stylus contact error, center shift error, repeatability and so on. Consequencely, the conclusion derived that elastic displacement of pallet had effect on measuring error mainly, and pallet design and setup method would be important.

  • PDF