• Title/Summary/Keyword: Measure of evaluation

Search Result 3,397, Processing Time 0.052 seconds

A study on evaluation of the image with washed-out artifact after applying scatter limitation correction algorithm in PET/CT exam (PET/CT 검사에서 냉소 인공물 발생 시 산란 제한 보정 알고리즘 적용에 따른 영상 평가)

  • Ko, Hyun-Soo;Ryu, Jae-kwang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.55-66
    • /
    • 2018
  • Purpose In PET/CT exam, washed-out artifact could occur due to severe motion of the patient and high specific activity, it results in lowering not only qualitative reading but also quantitative analysis. Scatter limitation correction by GE is an algorism to correct washed-out artifact and recover the images in PET scan. The purpose of this study is to measure the threshold of specific activity which can recovers to original uptake values on the image shown with washed-out artifact from phantom experiment and to compare the quantitative analysis of the clinical patient's data before and after correction. Materials and Methods PET and CT images were acquired in having no misalignment(D0) and in 1, 2, 3, 4 cm distance of misalignment(D1, D2, D3, D4) respectively, with 20 steps of each specific activity from 20 to 20,000 kBq/ml on $^{68}Ge$ cylinder phantom. Also, we measured the distance of misalignment of foley catheter line between CT and PET images, the specific activity which makes washed-out artifact, $SUV_{mean}$ of muscle in artifact slice and $SUV_{max}$ of lesion in artifact slice and $SUV_{max}$ of the other lesion out of artifact slice before and after correction respectively from 34 patients who underwent $^{18}F-FDG$ Fusion Whole Body PET/CT exam. SPSS 21 was used to analyze the difference in the SUV between before and after scatter limitation correction by paired t-test. Results In phantom experiment, $SUV_{mean}$ of $^{68}Ge$ cylinder decreased as specific activity of $^{18}F$ increased. $SUV_{mean}$ more and more decreased as the distance of misalignment between CT and PET more increased. On the other hand, the effect of correction increased as the distance more increased. From phantom experiments, there was no washed-out artifact below 50 kBq/ml and $SUV_{mean}$ was same from origin. On D0 and D1, $SUV_{mean}$ recovered to origin(0.95) below 120 kBq/ml when applying scatter limitation correction. On D2 and D3, $SUV_{mean}$ recovered to origin below 100 kBq/ml. On D4, $SUV_{mean}$ recovered to origin below 80 kBq/ml. From 34 clinical patient's data, the average distance of misalignment was 2.02 cm and the average specific activity which makes washed-out artifact was 490.15 kBq/ml. The average $SUV_{mean}$ of muscles and the average $SUV_{max}$ of lesions in artifact slice before and after the correction show a significant difference according to a paired t-test respectively(t=-13.805, p=0.000)(t=-2.851, p=0.012), but the average $SUV_{max}$ of lesions out of artifact slice show a no significant difference (t=-1.173, p=0.250). Conclusion Scatter limitation correction algorism by GE PET/CT scanner helps to correct washed-out artifact from motion of a patient or high specific activity and to recover the PET images. When we read the image occurred with washed-out artifact by measuring the distance of misalignment between CT and PET image, specific activity after applying scatter limitation algorism, we can analyze the images more accurately without repeating scan.

The Evaluation of Attenuation Difference and SUV According to Arm Position in Whole Body PET/CT (전신 PET/CT 검사에서 팔의 위치에 따른 감약 정도와 SUV 변화 평가)

  • Kwak, In-Suk;Lee, Hyuk;Choi, Sung-Wook;Suk, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.21-25
    • /
    • 2010
  • Purpose: For better PET imaging with accuracy the transmission scanning is inevitably required for attenuation correction. The attenuation is affected by condition of acquisition and patient position, consequently quantitative accuracy may be decreased in emission scan imaging. In this paper, the present study aims at providing the measurement for attenuation varying with the positions of the patient's arm in whole body PET/CT, further performing the comparative analysis over its SUV changes. Materials and Methods: NEMA 1994 PET phantom was filled with $^{18}F$-FDG and the concentration ratio of insert cylinder and background water fit to 4:1. Phantom images were acquired through emission scanning for 4min after conducting transmission scanning by using CT. In an attempt to acquire image at the state that the arm of the patient was positioned at the lower of ahead, image was acquired in away that two pieces of Teflon inserts were used additionally by fixing phantoms at both sides of phantom. The acquired imaged at a were reconstructed by applying the iterative reconstruction method (iteration: 2, subset: 28) as well as attenuation correction using the CT, and then VOI was drawn on each image plane so as to measure CT number and SUV and comparatively analyze axial uniformity (A.U=Standard deviation/Average SUV) of PET images. Results: It was found from the above phantom test that, when comparing two cases of whether Teflon insert was fixed or removed, the CT number of cylinder increased from -5.76 HU to 0 HU, while SUV decreased from 24.64 to 24.29 and A.U from 0.064 to 0.052. And the CT number of background water was identified to increase from -6.14 HU to -0.43 HU, whereas SUV decreased from 6.3 to 5.6 and A.U also decreased from 0.12 to 0.10. In addition, as for the patient image, CT number was verified to increase from 53.09 HU to 58.31 HU and SUV decreased from 24.96 to 21.81 when the patient's arm was positioned over the head rather than when it was lowered. Conclusion: When arms up protocol was applied, the SUV of phantom and patient image was decreased by 1.4% and 9.2% respectively. With the present study it was concluded that in case of PET/CT scanning against the whole body of a patient the position of patient's arm was not so much significant. Especially, the scanning under the condition that the arm is raised over to the head gives rise to more probability that the patient is likely to move due to long scanning time that causes the increase of uptake of $^{18}F$-FDG of brown fat at the shoulder part together with increased pain imposing to the shoulder and discomfort to a patient. As regarding consideration all of such factors, it could be rationally drawn that PET/CT scanning could be made with the arm of the subject lowered.

  • PDF

Evaluation of HalcyonTM Fast kV CBCT effectiveness in radiation therapy in cervical cancer patients of childbearing age who performed ovarian transposition (난소전위술을 시행한 가임기 여성의 자궁경부암 방사선치료 시 난소선량 감소를 위한 HalcyonTM Fast kV CBCT의 유용성 평가 : Phantom study)

  • Lee Sung Jae;Shin Chung Hun;Choi So Young;Lee Dong Hyeong;Yoo Soon Mi;Song Heung Gwon;Yoon In Ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.73-82
    • /
    • 2022
  • Purpose: The purpose of this study is to evaluate the effectiveness of reducing the absorbed dose to the ovaries and the quality of the CBCT image when using the HalcyonTM Fast kV CBCT of cervical cancer patients of child-bearing age who performed ovarian transposition Materials and Methods : Contouring of the cervix and ovaries required for measurement was performed on the computed tomography images of the human phantom (Alderson Rando Phantom, USA), and three Optically Stimulated Luminescence Dosimeter(OSLD) were attached to the selected organ cross-section, respectively. In order to measure the absorbed dose to the cervix and ovaries in the TruebeamTM pelvis mode (Hereinafter referred to as TP), The HalcyonTM Pelvis mode (Hereinafter referred to as HP) and The HalcyonTM Pelvis Fast mode (Hereinafter referred to as HPF), An image was taken with a scan range of 17.5 cm and also taken an image that reduced the Scan range to 12.5cm. A total of 10 cumulative doses were summed, It was replaced with a value of 23 Fx, the number of cervical cancer treatments, and compared In additon, uniformity, low contrast visibility, spatial resolution, and geometric distortion were compared and analyzed using Catphan 504 phantom to compare CBCT image quality between equipment. Each factor was repeatedly measured three times, and the average value was obtained by analysing with the Doselab (Mobius Medical Systems, LP. Versions: 6.8) program. Results: As a result of measuring absorbed dose by CBCT with OSLD, TP and HP did not obtain significant results under the same conditions. The mode showing the greatest reduction value was HPF versus TP. In HPF, the absorbed dose was reduced by 39.8% in the cervix and 19.8% in the ovary compared to the TP in the scan range of 17.5 cm. the scan range was reduced to 12.5 cm, absorbed dose was reduced by 34.2% in the cervix and 50.5% in the ovary. In addition, result of evaluating the quality of the image used in the above experiment, it complied with the equipment manufacturer's standards with Geometric Distortion within 1mm (SBRT standard), Uniformity HU, LCV within 2.0%, Spatial Resolution more than 3 lp/mm. Conclusion: According to the results of this experiment, HalcyonTM can select more various conditions than TruebeamTM in treatment of fertility woman who have undergone ovarian Transposition , because it is important to reduce the radiation dose by CBCT during radiation therapy. So finally we recommend HalcyonTM Fast kV CBCT which maintains image quality even at low mAs. However, it is consider that the additional exposure to low doses can be reduced by controlling the imaging range for patients who have undergone ovarian transposition in other treatment machines.

Evaluation of indirect N2O Emission from Nitrogen Leaching in the Ground-water in Korea (우리나라 농경지에서 질소의 수계유출에 의한 아산화질소 간접배출량 평가)

  • Kim, Gun-Yeob;Jeong, Hyun-Cheol;Kim, Min-Kyeong;Roh, Kee-An;Lee, Deog-Bae;Kang, Kee-Kyung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.6
    • /
    • pp.1232-1238
    • /
    • 2011
  • This experiment was conducted to measure concentration of dissolved $N_2O$ in ground-water of 59 wells and to make emission factor for assessment of indirect $N_2O$ emission at agricultural sector in agricultural areas of Gyeongnam province from 2007 to 2010. Concentrations of dissolved $N_2O$ in ground-water of 59 wells were ranged trace to $196.6{\mu}g-N\;L^{-1}$. $N_2O$ concentrations were positively related with $NO_3$-N suggesting that denitrification was the principal reason of $N_2O$ production and $NO_3$-N concentration was the best predictor of indirect $N_2O$ emission. The ratio of dissolved $N_2O$-N to $NO_3$-N in ground-water was very important to make emission factor for assessment of indirect $N_2O$ emission at agricultural sector. The mean ratio of $N_2O$-N to $NO_3$-N was 0.0035. It was greatly lower than 0.015, the default value of currently using in the Intergovernmental Panel on Climate Change (IPCC) methodology for assessing indirect $N_2O$ emission in agro-ecosystems (IPCC, 1996). It means that the IPCC's present nitrogen indirect emission factor ($EF_{5-g}$, 0.015) and indirect $N_2O$ emission estimated with IPCC's emission factor are too high to use adopt in Korea. So we recommend 0.0034 as national specific emission factor ($EF_{5-g}$) for assessment of indirect $N_2O$ emission at agricultural sector. Using the estimated value of 0.0034 as the emission factor ($EF_{5-g}$) revised the indirect $N_2O$ emission from agricultural sector in Korea decreased from 1,801,576 ton ($CO_2$-eq) to 964,645 ton ($CO_2$-eq) in 2008. The results of this study suggest that the indirect Emission of nitrous oxide from upland recommend 0.0034 as national specific emission factor ($EF_{5-g}$) for assessment of indirect $N_2O$ emission at agricultural sector.

The Effect of Pleural Thickening on the Impairment of Pulmonary Function in Asbestos Exposed Workers (석면취급 근로자에서 늑막비후가 폐기능에 미치는 영향)

  • Kim, Jee-Won;Ahn, Hyeong-Sook;Kim, Kyung-Ah;Lim, Young;Yun, Im-Goung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.6
    • /
    • pp.923-933
    • /
    • 1995
  • Background: Pleural abnormality is the the most common respiratory change caused by asbestos dust inhalation and also develop other asbestos related disease after cessation of asbestos exposure. So we conducted epidemiologic study to investigate if the pleural abnormality is associated with pulmonary function change and what factors are influenced on pulmonary function impairment. Methods: Two hundred and twenty two asbestos workers from 9 industries using asbestos in Korea were selected to measure the concentration of sectional asbestos fiber. Ouestionnaire, chest X-ray, PFT were also performed. All the data were analyzed by student t-test and chi-square test using SAS. Regressional analysis was performed to evaluate important factors, for example smoking, exposure concentration, period and the existence of pleural thickening, affecting to the change of pulmonary function. Results: 1) All nine industries except two, airborn asbestos fiber concentration was less than an average permissible concentration. PFT was performed on 222 workers and the percentage of male was 88.3%, their mean age was $41{\pm}9$ years old, and the duration of asbestos exposure was $10.6{\pm}7.8$ yrs. 2) The chest X-ray showed normal(89.19%), pulmonary Tb(inactive)(2.7%), pleral thickening (7.66%), suspected reticulonodular shadow(0.9%). 3) The mean values of height, smoking status, concentration of asbestos fiberwere not different between the subjects with pleural thickening and others, but age, cumulative pack-years, the duration of asbestos exposure were higher in subjects with pleural thickening. 4) All the PFT indices were lower in the subjects with pleural thickening than in the subjects without pleural thickening. 5) Simple regression analysis showed there was a significant correlation between $FEF_{75}$ which is sensitive in small airway obstruction and cumulative smoking pack-years, the duration of asbestos exposure and the concentration of asbestos fiber. 6) Multiple regression analysis showed all the pulmonary function indices were decreased as the increase of cumulative smoking pack-years and especially in the indices those are sensitive in small airway obstruction. Pleural thickening was associated with reduction in FVC, $FEV_1$, PEFR and $FEF_{25}$. Conclusion: The more concentration of asbestos fiber and the more duration of asbestos exposure, the greater reduction in $FEF_{50}$, $FEF_{75}$. Therefore PFT was important in the evaluation of early detection for small airway obstruction. Furthermore pleural thickening without asbesto-related parenchymal lung disease is associated with reduction in pulmonary function.

  • PDF

Studies of the Effects of Acupuncture Stimulation at Huatuo Jiaji(EX B2) Points on Axonal Regeneration of Injured Sciatic Nerve in the Rats (화타협척혈 침자극에 의한 손상 말초신경의 재생효과에 관한 연구)

  • Kim, Dae-Feel;Park, Young-Hoi;Keum, Dong-Ho
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.18 no.4
    • /
    • pp.39-61
    • /
    • 2008
  • Objectives : The present study was performed to investigate whether acupuncture stimulation in the rats affected regeneration properties of the injured sciatic nerve. A differential effect of acupuncture stimulation on the one point near the spinal nerve root controlling sciatic nerve activity and the other point in the peripheral area subordinated by injured nerve was compared. Materials and Methods: Rat sciatic nerves were injured by crush, and the effects on axonal regeneration on injured sciatic nerves were evaluated by acupuncture stimulation at two different regions. In proximal acupuncture stimulation group, acupuncture stimulation was performed on Huatuo Jiaji(EX B2) points located from L5 to S1 vertebral levels to stimulate the nearest spinal nerve root that innervates sciatic nerves. In distal acupuncture stimulation group, acupuncture stimulation was performed on Zusanli(ST 36) and Weizhong(BL 40) points to stimulate at peripheral area dominated by injured sciatic nerves. Acupuncture stimulation was given every other days for 1 or 2 weeks. Sciatic nerve tissues collected from acupuncture stimulation experimental groups, injury control group, and intact animal group were used for protein analysis by Western blotting or Hoechst nuclear staining. To determine axonal regeneration, Dil fluorescence dye was injected into the sciatic nerve 0.5 cm distal to the injury site in individual animal groups and Dil-labeled cells by retrograde tracing were measured in the DRG at lumbar 5 or in the spinal cord. DRG sensory neurons prepared from individual animal groups were used to measure the extent of neurite outgrowth and for immunofluorescence staining with anti-GAP-43 antibody. Results : Animal groups given proximal or distal acupuncture stimulation showed upregulation of GAP-43 and Cdc2 protein levels in the sciatic nerve at 7 days after injury. Cdk2 protein levels were strongly induced by nerve injury, but did not show changes by acupuncture stimulation. Phospho-Erk1/2 protein levels were elevated by acupuncture stimulation above those present in the injury control animals. These increase in regeneration-associated protein levels appeared to be related with increase cell proliferation in the injured sciatic nerves. Hoechst 33258 staining of sciatic nerve tissue to visualize nuclei of individual cells showed increased Schwann cell number in the distal portion of the injured nerve 7 and 14 days after injury and further increases by acupuncture stimulation particularly at the proximal position. Measurement of axonal regeneration by retrograde tracing showed significantly increased Dil-labeled cells in proximal acupuncture stimulation group compared to distal acupuncture stimulation group and injury control group. Finally, an evaluation of axonal regeneration by retrograde tracing showed increased number of Dil labeled cells in the DRG at lumbar 5 or in the ventral horn of the spinal cord at lower thoracic level at 7 days after nerve injury. Conclusions : The present data show that the proximal acupuncture stimulation at Huatuo Jiaji(EX B2) points governing injured sciatic nerves was more effective for axonal regeneration than the distal acupuncture stimulation. Further studies on functional recovery or associated molecular mechanisms should be critical for developing animal models and clinical applications.

Evaluation of a colloid gel(Slime) as a body compensator for radiotherapy (Colloid gel(Slime)의 방사선 치료 시 표면 보상체로서의 유용성 평가)

  • Lee, Hun Hee;Kim, Chan Kyu;Song, Kwan Soo;Bang, Mun Kyun;Kang, Dong Yun;Sin, Dong Ho;Lee, Du Heon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.191-199
    • /
    • 2018
  • Purpose : In this study, we evaluated the usefulness of colloid gel(slime) as a compensator for irregular patient surfaces in radiation therapy. Materials and Methods : For this study, colloid gel suitable for treatment was made and four experiments were conducted to evaluate the applicability of radiation therapy. Trilogy(Varian) and CT(SOMATOM, Siemens) were used as treatment equipment and CT equipment. First, the homogeneity according to the composition of colloid gel was measured using EBT3 Film(RIT). Second, the Hounsfield Unit(HU) value of colloid gel was measured and confirmed by CRIS phantom, Eclipse RTP(Eclipse 13.1, Varian) and CT. Third, to measure the deformation and degeneration of colloid gel during the treatment period, it was measured 3 times daily for 2 weeks using an ion chamber(PTW-30013, PTW). The fourth experiment was compared the treatment plan and measured dose distributions using bolus, rice, colloid gel and additional, dose profiles in an environment similar to actual treatment using our own acrylic phantom. Result : First experiment, density of the colloid gel cases 1, 2 and 3 was $1.02g/cm^3$, $0.99g/cm^3$ and $0.96g/cm^3$. When the homogeneity was measured at 6 MV and 9 MeV, case 1 was more homogeneous than the other cases, as 1.55 and 1.98. In the second experiment, the HU values of case 1, 2, 3 were 15 and when the treatment plan was compared with the measured doses, the difference was within 1 % at all 9, 12 MeV and a difference of -1.53 % and -1.56 % within the whole 2 % at 6 MV. In the third experiment, the dose change of colloid gel was measured to be about 1 % for 2 weeks. In the fourth experiment, the dose difference between the treatment plan and EBT3 film was similar for both colloid gel and bolus, rice at 6 MV. But colloid gel showed less dose difference than bolus and rice at 9 MeV. Also, dose profile of colloid gel showed a more uniform dose distribution than the bolus and rice. Conclusion : In this study, the density of colloid gel prepared for radiation therapy was $1.02g/cm^3$ similar to the density of water, and alteration or deformation was not observed during the radiotherapy process. Although we pay attention to the density when manufacturing colloid gel, it is sufficient in that it can deliver the dose uniformly through the compensation of the patient's body surface more than the bolus and rice, and can be manufactured at low cost. Further studies and studies for clinical applications are expected to be applicable to radiation therapy.

  • PDF

A Study on the Effect of Network Centralities on Recommendation Performance (네트워크 중심성 척도가 추천 성능에 미치는 영향에 대한 연구)

  • Lee, Dongwon
    • Journal of Intelligence and Information Systems
    • /
    • v.27 no.1
    • /
    • pp.23-46
    • /
    • 2021
  • Collaborative filtering, which is often used in personalization recommendations, is recognized as a very useful technique to find similar customers and recommend products to them based on their purchase history. However, the traditional collaborative filtering technique has raised the question of having difficulty calculating the similarity for new customers or products due to the method of calculating similaritiesbased on direct connections and common features among customers. For this reason, a hybrid technique was designed to use content-based filtering techniques together. On the one hand, efforts have been made to solve these problems by applying the structural characteristics of social networks. This applies a method of indirectly calculating similarities through their similar customers placed between them. This means creating a customer's network based on purchasing data and calculating the similarity between the two based on the features of the network that indirectly connects the two customers within this network. Such similarity can be used as a measure to predict whether the target customer accepts recommendations. The centrality metrics of networks can be utilized for the calculation of these similarities. Different centrality metrics have important implications in that they may have different effects on recommended performance. In this study, furthermore, the effect of these centrality metrics on the performance of recommendation may vary depending on recommender algorithms. In addition, recommendation techniques using network analysis can be expected to contribute to increasing recommendation performance even if they apply not only to new customers or products but also to entire customers or products. By considering a customer's purchase of an item as a link generated between the customer and the item on the network, the prediction of user acceptance of recommendation is solved as a prediction of whether a new link will be created between them. As the classification models fit the purpose of solving the binary problem of whether the link is engaged or not, decision tree, k-nearest neighbors (KNN), logistic regression, artificial neural network, and support vector machine (SVM) are selected in the research. The data for performance evaluation used order data collected from an online shopping mall over four years and two months. Among them, the previous three years and eight months constitute social networks composed of and the experiment was conducted by organizing the data collected into the social network. The next four months' records were used to train and evaluate recommender models. Experiments with the centrality metrics applied to each model show that the recommendation acceptance rates of the centrality metrics are different for each algorithm at a meaningful level. In this work, we analyzed only four commonly used centrality metrics: degree centrality, betweenness centrality, closeness centrality, and eigenvector centrality. Eigenvector centrality records the lowest performance in all models except support vector machines. Closeness centrality and betweenness centrality show similar performance across all models. Degree centrality ranking moderate across overall models while betweenness centrality always ranking higher than degree centrality. Finally, closeness centrality is characterized by distinct differences in performance according to the model. It ranks first in logistic regression, artificial neural network, and decision tree withnumerically high performance. However, it only records very low rankings in support vector machine and K-neighborhood with low-performance levels. As the experiment results reveal, in a classification model, network centrality metrics over a subnetwork that connects the two nodes can effectively predict the connectivity between two nodes in a social network. Furthermore, each metric has a different performance depending on the classification model type. This result implies that choosing appropriate metrics for each algorithm can lead to achieving higher recommendation performance. In general, betweenness centrality can guarantee a high level of performance in any model. It would be possible to consider the introduction of proximity centrality to obtain higher performance for certain models.

Mumps- and Rubella-specific IgG Levels in Adolescents (청소년기의 연령증가에 따른 볼거리 및 풍진 항체가 변동)

  • Cheon, Hae Won;Shin, Young Kyoo;Lee, Kang Woo;Choung, Ji Tae;Tockgo, Young Chang
    • Pediatric Infection and Vaccine
    • /
    • v.5 no.1
    • /
    • pp.128-135
    • /
    • 1998
  • Purpose : This study was intended to measure seropositivities and the level of mumps- and rubella-specific IgG of MMR vaccinees from 12 to 17 years of age in Korea. Materials and Methods : From May 1996 to July 1996 we obtained sera from students of 1 middle and 2 high schools in Seoul, who were MMR vaccinees from 12 to 17 years of age and had no evidence of immunodeficiency. These 216 study population include 110 males and 106 females. Mumps- and rubella-specific IgG antibody levels were measured by ELISA. Cut-off values for seropositivity were 20 U(Gamma Unit) in mumps and over 0.17 in rubella. Results : 1) As age increased, seropositivities to mumps increased, being 68.4% in 12 year, 79.3% in 13 year, 72.2% in 14 year, 82.0% in 15 year, 87.5% in 16 year, 87.0% in 17 year, which however has no statistical significance. 2) As age increased, the level of mumps-specific IgG antibody(mean+standard deviation, GU) increased, being $52.0{\pm}49.2$ in 12 year, $65.9{\pm}51.4$ in 13 year, $71.1{\pm}66.0$ in 14 year, $67.8{\pm}53.6$ in 15 year, $82.8{\pm}67.8$ in 16 year, $92.0{\pm}68.9$ in 17 year, which however has no statistical significance. 3) As age increased, seropositivities of rubella-specific IgG increased significantly, being 26.3% in 12 year, 20.7% in 13 year, 50.0% in 14 year, 67.2% in 15 year, 66.7% in 16 year, 65.2% in 17 year(P<0.001). 4) As age increased, rubella-specific IgG increased significantly, being $0.13{\pm}0.145$ in 12 year, $0.087{\pm}0.101$ in 13 year, $0.194{\pm}0.168$ in 14 year, $0.260{\pm}0.187$ in 15 year, $0.305{\pm}0.213$ in 16 year, $0.325{\pm}0.221$ in 17 year(P<0.001). There was positive correlation between age and rubella-specific IgG titer(rubella-specific $IgG=0.0517{\times}age-0.5586$, r=0.3752, P<0.001). Conclusion : In adolescent, seropositivities and the level of mumps-specific IgG remained relatively high, but approximately 20% of study population showed seronegativity. Seropositivities and the level of rubella-specific IgG showed the lowest level at 13 years of age and were increased with age after 14 years of age. Further evaluation may be needed to elucidate the cause of these changes of rubella-specific IgG.

  • PDF

Assessment of Nutrient Intakes of Lunch Meals for the Aged Customers at the Elderly Care Facilities Through Measuring Cooking Yield Factor and the Weighed Plate Waste (조리 중량 변화 계수 및 잔반계측법을 이용한 노인복지시설 이용자의 점심식사 영양섭취평가)

  • Chang, Hye-Ja;Yi, Na-Young;Kim, Tae-Hee
    • Journal of Nutrition and Health
    • /
    • v.42 no.7
    • /
    • pp.650-663
    • /
    • 2009
  • The purposes of this study were to investigate one portion size of menus served and to evaluate nutrient intake of lunch at three elderly care facility food services located in Seoul. A weighed plate method was employed to measure plate wastes and consumption of the menus served. Yield factors were calculated from cooking experiments based on standardized recipes, and were used to evaluate nutrient intake. One hundred elderly participated in this study for measuring plate waste and were asked to complete questionnaire. Nutrient analyses for the served and consumed meal were performed using CAN program. The yield factors of rice dishes after cooking are 2.4 regardless of rice dish types, 1.58 for thick soups, 0.60 to 0.70 for meat dishes, and 1.0 to 1.25 branched vegetable. Average consumption quantity of dishes were 235.97 g for rice, 248.53 g for soup, 72.83 g for meat dishes, 39.80 g for vegetables and 28.36 g for Kimchi. On average the food waste rate is 14.0%, indicating the second highest plate waste percentage of Kimchi (26.2%), and meat/fish dish (17.3%). The evaluation results of NAR (Nutrition Adequacy Ratio) showed that iron (0.12), calcium (0.64), riboflavin (0.80), and folic acid (0.97) were less than 1.0 in both male and female elderly groups, indicating significant differences of NAR among three facilities. Compared to the 1/3 Dietary Reference Intake (DRIs) for the elderly groups, nutrient intake analysis demonstrated that calcium (100%) and iron (100%), followed by riboflavin, vitamin A, and Vitamin B6 did not met of the 1/3 EAR (Estimated Average Requirement). For the nutritious meal management, a professional dietitian should be placed at the elderly care center to develop standardized recipes in consideration of yield factors and the elderly's health and nutrition status.