• Title/Summary/Keyword: Measure of evaluation

Search Result 3,417, Processing Time 0.039 seconds

Environmental impact evaluation and improvement measure of incineration plant by life cycle assessment (전과정평가를 이용한 소각시설의 환경영향평가 및 개선방안)

  • Kim, Hyeong-Woo;Kim, Kyeong-Ho;Park, Hung-Suck
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.21 no.4
    • /
    • pp.88-100
    • /
    • 2013
  • This study evaluated the direct and indirect environmental impacts of various unit operations of a industrial waste incineration plant by using the life cycle assessment tool and reviewed the improvement plan. During the incineration process, the direct environmental impact was decreased with decrease in emission of various air pollutants by incorporating an air pollution prevention facilities. However, an increase in indirect environmental impacts was observed as a consequence of resources and energy of consumption at the various operational facilities. Consequently, quantitative direct and indirect impact were 89.1%, 10.9%, respectively. The environmental impact analysis of system revealed the highest impact of incineration followed by the impacts of other unit processes such as semidry reactor, and bag-filter. The various air pollutants and ashes generated during the incineration process caused the most significant environmental impact. Among the various categories of environmental impact, global warming accounted the highest impact(more than 85%) followed by eutrophication, and abiotic depletion. As a result of the avoided impact by the utilization of heat generated during the waste incineration process, using an incineration heat for steam and electricity obtained the impact reduction of 45.5%, 19.8%. So, during siting of new incineration plant, the utilization of steam generated from the waste combustion is highly considered to reduce the environmental impact.

Study on Performance Evaluation of Dental X-ray Equipment (치과 방사선 발생기의 성능평가에 관한 연구)

  • Jung, Jae-Eun;Jung, Jae-Ho;Kang, Hee-Doo;Lee, Jong-Woong;Ra, Keuk-Hwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.115-119
    • /
    • 2009
  • I think this will be valuable reference for assuring consistency and homogeneity of clarity and managing dental radiation equipment by experimentation of dental radiation equipment permanent which based on KS C IEC 61223-3-4 standard and KS C IEC 61223-2-7. Put a dental radiation generator and experiment equipment as source and film(sensor) length within 30 em, place the step-wedge above the film(sensor). Tie up tube voltage 60 kVp, tube current 7 mA and then get an each image through CCD sensor and film by changing the exposure time as 0.12sec, 0.25sec, 0.4sec. Repeat the test 5times as a same method. Measure the concentration of each stage of film image, which gained by experiment, using photometer. And the image that gained by CCD sensor, analyze the pixel value's change by using image J, which is analyzing image program provided by NIH(National Institutes of Health). In case of film, while 0.12sec and 0.25sec show regular rising pattern of density gap as exposure time's increase, 0.4sec shows low rather than 0.12sec and 0.25sec. In case of CCD sensor density test, the result shows opposite pattern of film. This makes me think that pixels of CCD's sensor can have 0~255 value but it becomes saturation if the value is over 255. The way that getting clear reception during decreasing human's exposed radiation is one of maintaining an equipment as a best condition. So we should keeping a dental radiation equipment's condition steadily through cyclic permanent test after factor examination. Even digital equipment doesn't maintain a permanent, it can maintain a clarity by post processing of image so that hard to set it as standard of permanent test. Therefore it would be more increase the accuracy that compare a film as standard image. Thus I consider it will be an important measurement to care for dental radiation equipment and warrant homogeneity, consistency of dental image's clarity through comparing pattern which is the result from factor test against cyclic permanent test.

  • PDF

A Practical standard Air Flow Generator System to Calibrate and Compare Performance of Two Different Respiratory Air Flow Measurement Modules (호흡기류 계측모듈의 교정과 성능 비교를 위한 실용적인 표준기류 생성 시스템)

  • Lee, In-Kwang;Park, Mi-Jung;Lee, Sang-Bong;Kim, Kyoung-Ok;Cha, Eun-Jong;Kim, Kyung-Ah
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.4
    • /
    • pp.115-122
    • /
    • 2015
  • A standard air flow generator system was developed to generate air flows of various levels simultaneously applied to two different air flow transducer modules. Axes of two identical standard syringes for spirometer calibration were connected with each other and driven by a servo-motor. Linear displacement transducer was also connected to the syringe axis to accurately acquire the volume change signal. The user can select either sinusoidal or square waveform of volume change and manually input any volume as well as maximal flow rate levels ranging 0~3 l and 0~15 l/s, respectively. Various volume and flow levels were input to operate the system, then the volume signal was acquired followed by numerical differentiation to obtain the air flow signal. The measured volumes and maximal air flow rates were compared with the user input data. The relative errors between the user-input and the measured stroke volumes were all within 0.5%, demonstrating very accurate driving of the system. In case of the maximal flow rate, relatively large error was observed when the syringe was driven very fast within a very short time duration. However, except for these few data, most measured flow rates revealed relative errors of approximately 2%. When the measure and user-input stroke volume and maximal flow rate data were analyzed by linear regression analysis, respectively, the correlation coefficients were satisfactorily higher than 0.99 (p < 0.0001). These results demonstrate that the servo-motor controls the syringes with enough accuracy to generate standard air flows. Therefore, the present system would be very much practical for calibration process as well as performance evaluation and comparison of two different air flow transducer modules.

Accuracy Evaluation of Non-prism Total Station for Topographic Surveying (지형측량을 위한 무 프리즘 토털스테이션 정확도 평가)

  • Seo, Dong-Ju
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.24 no.5
    • /
    • pp.433-441
    • /
    • 2006
  • With a development of electrical technology in recent, it is possible to measure distance without direct contact to object using laser which launched at instrument and reflect from object. Furthermore, the advent of non prism total station brought the increment of application in many fields including not only road, airport, and harbors but also measurement and monitoring of structural displacement in construction fields. In this study, therefore, to evaluate accuracy of non prism total station, accuracy was analyzed by measuring certain distance which classified by both certain materials and angle of reflection. By this method, the derived values were applied to topographical survey for the efficient applicability. According to a study, result value of non prism total station was satisfBctory regardless of material when the angle of reflection was 90 degrees. RMSE increased when the angle of reflection are gradually increased to acute angle. In result of regression analysis using certain distance which classified by both materials and angles of reflection, there is relationship between distance and angle of reflection, but material has no relevance to the result value. When carrying out general topographical survey, proper application of non prism total station will go far conducting safe and prompt survey at the dangerous site such a road which have lots of traffic flow and rock joint which have high angles of inclination.

Comparison of Acoustic Phonetic Characteristics of Korean Fricative Sounds Pronounced by Hearing-impaired Children and Normal Children (청각장애 아동과 일반 아동의 마찰음에 나타난 음향음성학적 특성 비교)

  • Kim, YunHa;Kim, Eunyeon;Jang, Seoung-Jin;Choi, Yaelin
    • Phonetics and Speech Sciences
    • /
    • v.6 no.2
    • /
    • pp.73-79
    • /
    • 2014
  • Alveolar fricative sounds /s/ and /s'/ are learned last for normal children in the speech development process for Koreans. These are especially difficult to articulate for hearing-impaired children often causing articulation errors. The acoustic phonetic evaluation uses testing tools to provide indirect and object information. These objective resources can be compared with standardized resources on speech when interpreting the results of a test. However, most previous studies in Korea did not consider acoustic studies that used the spectrum moment values of hearing-impaired children. Therefore, this study was conducted to compare the characteristics of hearing-impaired children's pronunciation of fricative sounds using spectrum moment values. For this purpose, the study selected a total of 10 hearing-impaired children (5 boys and 5 girls) currently in 3rd or 5th grade and attending one of the elementary schools in Seoul or Gyeonggi-do. For the selection process, their age, type of hearing aid, implantation of hearing aid (CI) before two years of age, hearing capacity (dB) before and after wearing the hearing aid, duration of speech rehabilitation, and time of learning alveolar fricative sounds were all considered. Also, 10 normal children (5 boys and 5 girls) were selected among 3rd or 5th grade students attending one of the elementary schools in Seoul or Gyeonggi-do. The subjects were asked to read the carrier sentence, "I say _______," including a list of 12 meaningless syllables composed of CV and VCV syllables, including alveolar fricative sounds /s/ and /s'/ and vowels /a/, /i/, and /u/. The recorded resources were processed through the Time-frequency Analysis Software Program to measure M1 (mean), M2 (variance), M3 (skewness), and M4 (kurtosis) of the fricative noise. No significant differences were found when comparing spectrum threshold values in the acoustic phonetic characteristics of hearing-impaired children and normal children in alveolar fricative sound pronunciation according to vowels /a/, /i/, and /u/, alveolar fricative sounds /s/ and /s'/, and syllable structure (CV, VCV) other than, for M3 in the comparison of groups according to disability. In the comparison of syllable structures, there were statistically significant differences in M1, M2, M3, and M4 with clinical significance. However, there was no significant difference in results when comparing the alveolar fricative sounds according to the vowels.

Development of STEAM Program Based on Emotion Science for Students of Early Elementary School (초등학교 저학년 학생을 위한 감성과학 기반 융합인재교육(STEAM) 프로그램 개발)

  • Kwon, Jieun;Kwak, Sojung;Kim, HeaJin;Lee, SeJung
    • Science of Emotion and Sensibility
    • /
    • v.20 no.4
    • /
    • pp.79-88
    • /
    • 2017
  • As the age in which the importance of sensitivity has increased, education for the future generation regarding emotion engineering, affective recognition and cognitive science have taken center stage. We measure human's emotion quantitatively, analyze evaluation and apply them to various services in life, which are based on human technology. Therefore, we need the education which is related to emotion science to cultivate talented people. The goal of this paper is to suggest the possibility of emotion science education and effective methods through development of the STEAM (Science, Technology, Engineering, Arts, Mathematics) program which can teach emotion science to early elementary school students by applying it to pilot classes. For this study, first, we build a program, 'The mind made by figure' for student of early elementary school. The method of STEAM was used in this program, because it is an effective system to educate the emotion science. We recognize the needs and value of this program development through theory and benchmarking of STEAM related to emotion science. And then the contents of class, activities, course book and kit are designed with elementary school textbook of pertinent grade. Secondly, we analyze the result which is applied in two pilot classes of second grade by satisfaction survey and teacher interview. As a result, the average of satisfaction level was very high (4.40/5), Class participation was especially high. Third, we discuss the ability, value and limits of this program based on the result of analysis. The outcome of this research shows that students of early elementary school who have difficulty in understanding science can approach the education program related to emotion science with ease and interest. We hope this education will help students understand emotion science effectively, and to train people to lead the emotion centered era.

Development and Application of TDR Penetrometer for Evaluation of Soil Water Content of Subsoil (지반의 함수비 평가를 위한 관입형 TDR 프로브의 개발 및 적용)

  • Hong, Won-Taek;Jung, Young-Seok;Lee, Jong-Sub;Byun, Yong-Hoon
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.2
    • /
    • pp.39-46
    • /
    • 2015
  • Dielectric constant depends on the variation of soil water content, and the estimation of soil water content using time domain reflectometry (TDR) has been studied by many researchers. The purpose of this study is the development and application of TDR penetrometer (TDRP) in order to evaluate the soil water content according to the penetration depth. The TDRP consists of cone, sleeve, driving rod, hammer, and guide. Three electrodes, which are used to measure the dielectric constant of soils, are mounted on the surface of sleeve and, in turn, connected with coaxial cable and time domain reflectometer. To establish the relationship between the volumetric water content and dielectric constant, several laboratory tests by using the TDRP are performed in the specimens with a variety of volumetric water content. The experimental results show that the dielectric constant is strongly correlated to volumetric water content as polynomial equations with an order of 3. In addition, the volumetric water content calculated from the dielectric constant is similar to that obtained from the sample weight. In the field, a small sampler is used to compare the volumetric water content calculated from the dielectric constant with the volumetric water content obtained from the sample. The results of field application demonstrate that the volumetric water content estimated by the TDRP shows similar trend to the gravimetric water content of sample. This study suggests that the TDRP is effectively used to evaluate the volumetric water content of unsaturated soils according to the penetration depth.

A Performance Evaluation of Diagnostic X-ray Unit Depends on the Hospitals Size (병원 규모별 진단용 X선 발생장치의 성능 평가)

  • Park, Ju-Hun;Im, In-Chul;Dong, Kyung-Rae;Kang, Se-Sik
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.1
    • /
    • pp.31-36
    • /
    • 2009
  • The purpose of this study is to measure the tube voltage, the tube current/volume, exposure time and exposure dose of diagnostic X-ray unit in each doctor offices, hospitals and general hospitals for evaluating the performance of such device, to learn the method and technology of its measurement and to suggest its importance. Research subjects were total 30 X-ray units and divided into groups of 10 X-ray units each. The tube voltage, the tube current/volume, exposure time and exposure dose were measured using percentage average error, and then reproducibility of exposure dose was measured through calculating coefficient of variation. The results are like followings; The tube voltage correctness examination showed that incongruent devices among total 30 X-ray units were 5 devices (16.7%). The tube current correctness examination showed that incongruent X-ray units were 3 devices (10.0%). The tube current volume correctness examination showed that incongruent X-ray units were 4 devices (13.3%). Finally, according to exposure time correctness examination, incongruent X-ray units were 5 devices (16.7%) and according to reproducibility examination of exposure dose, incongruent X-ray units were 7 devices (23.3%). Above results showed serious problem in performance management based on management regulation of diagnostic X-ray unit; it means that regular checkout and safety management are required, and as doing so, patients will be able to receive good quality of medical service by the reduction of radiation exposure time, image quality administration, unnecessary retake and etc. Therefore, this study suggests that the performance of diagnostic X-ray units should be checked regularly.

A study on practice of obesity control by school nurses (보건교사의 비만관리실태 조사연구)

  • Ju, Hyun-Ok;Song, Mi-Gyoung
    • Journal of the Korean Society of School Health
    • /
    • v.15 no.2
    • /
    • pp.249-261
    • /
    • 2002
  • This study was a research study to find out the real picture and practice of student obesity control by primary, middle and high school school nurses. The study sampled 196 school nurses working in the Busan City and Northern Gyungsang Province, who agreed on the purpose of the study. When it comes to the study process, at the meeting of the whole school nurses, the researcher explained the purpose of the study and asked them to complete questionnaires and return on the spot. The study is designed to provide basic data for school nurses in field to systematically and efficiently control student obesity by examining perception of school obesity control and the real picture or practice of obesity control as well as its problems. The study used SPSS 10.0 to analyze data. The results are as follows: Annual plans about obesity control appeared significant at the primary school, 89.3%, higher than 77.3% of the middle and high school(p<0.05). Annual project evaluation showed a significant difference by regions, 56.0% of metro cities vs. small cities(p<0.01). The number of measuring weight of obese students was higher at the primary school than at the middle and high school(p<0.05). Also small cities conducted the weight measurement more often than metro cities(p<0.001). Among the health education methods for obesity, counseling appeared statistically significant(p<.01). The health education showed a significant difference in more experienced school nurses. Among the educational media, environment postings were used at the primary school, 24.0%, higher than 5.3% of the middle and high school. It showed a significant difference(p<.001). OHP or epidiascopes were used at the primary school, 36.4%, significantly higher than the middle and high school(p<.001). In addition, computer was used at the primary school, 21.5%, higher than the middle and high school(p<.05). Problems of obesity education data included a lack of textbooks and programs and a short of educational media. However it didnt show a significant difference in schools or in regions. Counseling activities for obesity showed a significant difference in schools(p<.01) and in regions(p<.001). When parents with obese students were in counseling, those in their 20s used home correspondence and those in their 30s and 40s used phone call(p<.01). The rate of equipment to measure obesity was higher at the middle and high school than the primary school, showing a significant difference(p<.001). Therefore, regular health education curriculums for school nurses should be systematically created to promote student health. Furthermore, it needs to make standard textbooks for health education by grades as well as by levels and to develop various educational programs and educational media.

Investigation of the changes in texture of soybean sprout depending on the heating conditions in sous-vide and conventional hot water cooking (Sous-vide가열과 열탕가열 조건에 따른 콩나물 머리와 줄기의 조직감 변화에 관한 연구)

  • Lee, Yun Ju;Jung, Hwabin;Yoon, Won Byong
    • Journal of Applied Biological Chemistry
    • /
    • v.61 no.3
    • /
    • pp.219-226
    • /
    • 2018
  • The purpose of this study was to investigate the effect of thermal treatments, such as a sous-vide and a conventional hot water cooking, on the texture changes of soybean sprout. A novel method to measure texture properties of soybean sprout have been determined because of the irregular geometry of soybean sprout. The shape of cotyledon of bean spout was accurately analyzed using an image processing and a geometry model. To minimize the effect of the contact area on the texture measurement, a blade type of probe was selected for the measurement. True stress was evaluated to reflect the shape changes during deformation, and demonstrated that the measurement accurately distinguished the effect of thermal treatment on the texture. Different heating time (i.e., 0, 10, 20, and 30 min) was applied for both sous-vide and conventional cooking. Thermal processing caused hardening of textures for both cotyledon and hypocotyl of soybean sprout. The conventional cooking method showed higher stress values than those of sous-vide cooking. Sprouts cooked by sous-vide released the moisture after thermal processing while sprout cooked by a conventional water bath method could hold the moisture content during thermal processing. The soybean sprouts treated by conventional cooking method showed a higher score in sensory evaluation.