• Title/Summary/Keyword: Measure of error change

Search Result 148, Processing Time 0.028 seconds

A Study on the Automatic Level Measurement for Land Leveling (경지 균평 작업을 위한 자동 표고 측정에 관한 연구)

  • 김종안;김수현;곽윤근
    • Journal of Biosystems Engineering
    • /
    • v.22 no.3
    • /
    • pp.269-278
    • /
    • 1997
  • An automatic level measurement system was developed to level the land fer direct seeding of rice. A laser transmitter/receiver set was used to measure land-level. The inclination error occurred in level measurement on irregular land surface could be compensated by attaching rotating mass. The level measuring experiments were performed on three kinds of different shapes(step, random, sine). This system could accurately measure step level of which amplitude was 40mm in 0.5s, random level change within $\pm$ 5mm maximum measurement error, and sine level change of which spatial frequency was 0.5m-1. To verify performance of the inclination error compensation system, frequency transfer function(acceleration input vs. inclination error) was computed by spectral analysis. The inclination error was decreased about 20㏈ by error compensation system.

  • PDF

Determination of the Number of Components in Spectroscopy from the Multilinear Model Fitting

  • Kim, Choong-Rak;Chung, Byung-Chull;Lee, Choon-Hwan
    • Communications for Statistical Applications and Methods
    • /
    • v.6 no.2
    • /
    • pp.367-374
    • /
    • 1999
  • Biological specimens contain several components and multilinear models are very useful in analyzing these data. After fitting the model the number of components are determined by the change of mean squared error however this method is quite rule of thumb. in this paper we suggest a measure to decide the number of components based on the relative change of to mean squared error. Simulations are done and applications to real data set are given as illustrations.

  • PDF

Power Quality Disturbances Detection Technique using Filter Bank and Adaptive Filters (필터뱅크와 적응필터를 이용한 전력품질 외란 검출기법)

  • Yun, Jae-Jun;Lee, Jeong-Kyu;Sohn, Sang-Wook;Bae, Hyeon-Deok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.1
    • /
    • pp.162-167
    • /
    • 2012
  • In power quality monitoring, it is very important to detect disturbances (sag, swell, transient, and interruption) accurately. In this paper, a detection method for power quality disturbances by combining the filter bank system and adaptive filter is proposed. To decompose power signal, binary tree structured filter bank system is designed. In the filter bank system, the fundamental filter bank(QMF bank) is used as a module in each decomposing level. An adaptive filter is used to improve the detection accuracy of disturbances for each subband signal. In the adaptive filter, the measure of estimated error change is used to detect singular points of power quality disturbances. Computer simulations were performed on synthetic signals which have disturbances to assess the performance of the proposed method.

A Study on the Development of the Automatic Level Measurement System (자동 표고 측정 장치 개발에 관한 연구)

  • 김종안;김수현;곽윤근
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.756-760
    • /
    • 1997
  • In this research, the automatic level measurement system used in land leveling was developed. By using a laser transmitter and a receiver as measuring equipments, level was measured automatically. The driving part of this system was composed of stepping motor, timing belt and pulley. It drived the laser receiver to track laser beam generated form the laser transmitter. The level measuring experiments were performed about three level change shapes (step, random, sine). This system could measure step level change of which amplitude was 40mm in 0.5s, random level change within .+-. mm, maximum measurement error. In case of sine level change, experiment was executed with varying the spatial frequency of level change. As a result, this system was able to measure sine level change of which spatial frequency was 0.5m $^{-1}$ accurately.

  • PDF

A NEW APPROACH FOR ASYMPTOTIC STABILITY A SYSTEM OF THE NONLINEAR ORDINARY DIFFERENTIAL EQUATIONS

  • Effati, Sohrab;Nazemi, Ali Reza
    • Journal of applied mathematics & informatics
    • /
    • v.25 no.1_2
    • /
    • pp.231-244
    • /
    • 2007
  • In this paper, we use measure theory for considering asymptotically stable of an autonomous system [1] of first order nonlinear ordinary differential equations(ODE's). First, we define a nonlinear infinite-horizon optimal control problem related to the ODE. Then, by a suitable change of variable, we transform the problem to a finite-horizon nonlinear optimal control problem. Then, the problem is modified into one consisting of the minimization of a linear functional over a set of positive Radon measures. The optimal measure is approximated by a finite combination of atomic measures and the problem converted to a finite-dimensional linear programming problem. The solution to this linear programming problem is used to find a piecewise-constant control, and by using the approximated control signals, we obtain the approximate trajectories and the error functional related to it. Finally the approximated trajectories and error functional is used to for considering asymptotically stable of the original problem.

Design and Application of Gradient-descent-based Self-organizing Fuzzy Logic Controller (그래디언트 감소를 기반으로하는 자기구성 퍼지 제어기의 설계 및 응용)

  • 소상호;박동조
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1998.10a
    • /
    • pp.191-196
    • /
    • 1998
  • A new Fuzzy Logic Controller(FLC) called a Gradient-Descent Based Self-Organizing Controller is presented. The Self-Organizing Controller(SOC) has two inputs such as error and change of error, and updates control rules with monitoring a performance measure. There are many works in the SOC which concentrate on the self-organizing ability in control rule base, but have a few research on the performance measure which is akin to sliding mode control. With this procedure, we can get a robust performance measure on the SOC. To verify the perfomance of proposed controller, we have performed for the cart-pole system which is one of the well-known benchmark problem in the control literature.

  • PDF

Numerical analysis of the thermal fluid characteristics of phase change material in can type container (수치해석과 실험을 통한 Can type container 내부 상변화 물질의 열유체적 특성분석)

  • Seung Min Heo;Su Woong Hyun;Hee Jun Jeong;Dong Ho Shin
    • Journal of the Korean Society of Visualization
    • /
    • v.21 no.2
    • /
    • pp.63-71
    • /
    • 2023
  • Energy storage and distribution technologies are emerging as important factors as research on renewable energy continues. Analyzing the thermal flow of phase change material inside a latent heat storage device and to predict the phase change time is an important part for improvement of thermal performance. However, most of the current research is based on the trial-and-error experimental investigation to measure the phase change time. Therefore, in this study, a can-type phase change material container was designed, and the numerical method for analyzing the thermal flow of phase change material was established and validated. The error rate of the phase change time between the numerical and experimental results was within 5%, which proves its reliability. As a result, the phase change finishing times were found to be 78 minutes with inlet fluid temperature of 80℃ during charging process, and 126 minutes with inlet fluid temperature of 9℃ during discharging process.

Implementation and Enhancement of GMM Face Recognition System using Flatness Measure (평탄도 측정을 이용한 GMM 얼굴인식기 구현 및 성능향상)

  • 천영하;고대영;김진영;백성준
    • Proceedings of the IEEK Conference
    • /
    • 2003.07e
    • /
    • pp.2004-2007
    • /
    • 2003
  • This paper describes a method of performance enhancement using Flatness Mesure(FM) for the Gaussian Mixture Model(GMM) face recognition systems. Using this measure we discard the frames having low information before training and test. As the result, the performance increases about 9% in the lower mixtures and calculation burden is decreased. As well, the recognition error rate is decreased under the illumination change surroundings. We use the 2D DCT coefficients lot face feature vectors and experiments are carried out on the Olivetti Research Laboratory (ORL) face database.

  • PDF

The Organization of Measuring Systems of Linear Cycle Plane Positioning Accuracy on NC Lathes (NC 선반에서 직선 사이클 평면 위치결정 정도 측정 시스템의 구성)

  • 김영석;김재열;송인석;곽이구;정정표;한지희
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.387-392
    • /
    • 2002
  • It is very important to measure linear cycle plane positioning accuracy of NC lathes as they affect those of all other machines machined by them in industries. For example, if the linear cycle plane positioning accuracy of each axes directions is bad, the accuracy of works will be wrong and the change-ability will be bad in the assembly of machine parts. In this paper, computer software systems are organized to measure linear displacements of ATC(Automatic tool changer) of NC lathes using linear scale and time pulses comming out from computer in order to get data at constant time intervals from the sensors. And each sets of error data gotten from the test is expressed to plots by computer treatment and the results of linear cycle plane positioning error motion estimated to numerics by statistical treatments.

  • PDF

Measuring of Linear Motion Accuracy of NC Lathe using Linear Scales (리니어 스케일을 이용한 NC 선반의 직선 운동정도 측정)

  • 김영석;김재열;한지희;정정표;윤원주;송인석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1243-1248
    • /
    • 2003
  • It is very important to measure linear motion accuracy of NC lathe as it affects all other parts of machines machined by them in industries. If the motion accuracy of NC lathe is bad, the dimension accuracy and the change-ability of works will be bad in the assembly of machine parts. In this paper, computer software systems are organized to measure linear motion of ATC(Automatic tool changer) on zx plane of NC lathe using two linear scales and the time pulses coming out from computer in order to get data at constant time intervals from the linear scales. And each sets of error data obtained from the test is discripted to plots and the results of linear motion errors are expressed as numerics by computer treatment.

  • PDF