• 제목/요약/키워드: Measure energy

검색결과 1,922건 처리시간 0.028초

국산 소경재의 휨 성질을 이용한 충격에너지와 최대하중까지 일-에너지 예측연구 (Study on the Prediction of the Work-Energy to the Maximum Load and Impact Bending Energy from the Bending Properties)

  • 차재경
    • 한국가구학회지
    • /
    • 제19권5호
    • /
    • pp.350-357
    • /
    • 2008
  • This research investigates the bending properties to predict the work-energy to maximum load and impact bending energy from static bending and impact bending test. Specimens were prepared from lumber made of thinning crop-trees. Matched specimens were used for MC 12% and green moisture specimens to measure the effect of moisture content on the absorbed energy from static and impact bending tests. The bending properties such as MOE, MOR, etc. is a good predictor to investigate the work-energy and work-energy per unit volume from static bending and impact bending test. The impact bending energy is increased with increasing moisture content. However, the work to maximum load from static bending test is increasing with increasing the MC only for higher density species.

  • PDF

Edge Complement of the Cornea's Endothelial Cell Using Energy Function

  • Kim, Jin-Woo
    • Journal of information and communication convergence engineering
    • /
    • 제5권2호
    • /
    • pp.155-158
    • /
    • 2007
  • An area distribution of Corneal Endothelial Cell(CEC) include important clinical information. In this paper, we present a two-step processing method of contour complement for the CEC. In the first step; we apply not only conventional Laplasian Gaussian filters(LGF) but also three-arrow-shaped LGFs which is newly developed to extract vertices of hexagonal shapes. In the second step; we complement the lacking part of CEC by using an energy minimum algorithm. Using the results, we measure areas of CEC.

Non-Additive Ranking of Release Scenarios in a Low and Intermediate Waste Repository

  • Kim, Seong-Ho;Kim, Tae-Woon;Jaejoo Ha
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2004년도 학술논문집
    • /
    • pp.188-188
    • /
    • 2004
  • In the present study, a multicriteria decision-making (MCDM) problem of ranking of important radionuclide release scenarios in a low and intermediate radioactive waste repository is to treat on the basis of non-additive fuzzy measures and fuzzy integral theory. Ranking of important scenarios can lead to the provision of more effective safety measure in a design stage of the repository. The ranking is determined by a relative degree of appropriateness of scenario alternatives.(omitted)

  • PDF

MTS(마할라노비스-다구찌 시스템) 기법을 이용한 기업 품질경쟁력 측정 (The Study of Measure of Company Quality Competitive by using MTS Method)

  • 지철민;이상복
    • 품질경영학회지
    • /
    • 제33권2호
    • /
    • pp.64-73
    • /
    • 2005
  • In this paper, we introduce MTS(Mahalanobis-Taguchi System) Method which is suggested Dr. Taguchi in later 1990. We apply MTS Method for Quality Competitive Appraisal System(QCAS) Model which is executived from 1997 by Agency for Technology and Standards, Ministry of Commerce, Industry and Energy(MOCIE). We can measure company Quality competitive by using MTS. MTS Measure can not be compared statistical sum by calculated QCAS. MTS can be possible distinct subtle which can not distinct using statistical sum. Also MTS Method can seek more strong effect factor among of many factor. If A Company use MTS Method, can find vital factor and level of destination.

Development of Diode Based High Energy X-ray Spatial Dose Distribution Measuring Device

  • Lee, Jeonghee;Kim, Ikhyun;Park, Jong-Won;Lim, Yong-Kon;Moon, Myungkook;Lee, Sangheon;Lim, Chang Hwy
    • Journal of Radiation Protection and Research
    • /
    • 제43권3호
    • /
    • pp.97-106
    • /
    • 2018
  • Background: A cargo container scanner using a high-energy X-ray generates a fan beam X-ray to acquire a transmitted image. Because the generated X-rays by LINAC may affect the image quality and radiation protection of the system, it is necessary to acquire accurate information about the generated X-ray beam distribution. In this paper, a diode-based multi-channel spatial dose measuring device for measuring the X-ray dose distribution developed for measuring the high energy X-ray beam distribution of the container scanner is described. Materials and Methods: The developed high-energy X-ray spatial dose distribution measuring device can measure the spatial distribution of X-rays using 128 diode-based X-ray sensors. And precise measurement of the beam distribution is possible through automatic positioning in the vertical and horizontal directions. The response characteristics of the measurement system were evaluated by comparing the signal gain difference of each pixel, response linearity according to X-ray incident dose change, evaluation of resolution, and measurement of two-dimensional spatial beam distribution. Results and Discussion: As a result, it was found that the difference between the maximum value and the minimum value of the response signal according to the incident position showed a difference of about 10%, and the response signal was linearly increased. And it has been confirmed that high-resolution and two-dimensional measurements are possible. Conclusion: The developed X-ray spatial dose measuring device was evaluated as suitable for dose measurement of high energy X-ray through confirmation of linearity of response signal, spatial uniformity, high resolution measuring ability and ability to measure spatial dose. We will perform precise measurement of the X-ray beamline in the container scanning system using the X-ray spatial dose distribution measuring device developed through this research.

A dominant vibration mode-based scalar ground motion intensity measure for single-layer reticulated domes

  • Zhong, Jie;Zhi, Xudong;Fan, Feng
    • Earthquakes and Structures
    • /
    • 제11권2호
    • /
    • pp.245-264
    • /
    • 2016
  • A suitable ground motion intensity measure (IM) plays a crucial role in the seismic performance assessment of a structure. In this paper, we introduce a scalar IM for use in evaluating the seismic response of single-layer reticulated domes. This IM is defined as the weighted geometric mean of the spectral acceleration ordinates at the periods of the dominant vibration modes of the structure considered, and the modal strain energy ratio of each dominant vibration mode is the corresponding weight. Its applicability and superiority to 11 other existing IMs are firstly investigated in terms of correlation with the nonlinear seismic response, efficiency and sufficiency using the results of incremental dynamic analyses which are performed for a typical single-layer reticulated dome. The hazard computability of this newly proposed IM is also briefly discussed and illustrated. A conclusion is drawn that this dominant vibration mode-based scalar IM has the characteristics of strong correlation, high efficiency, good sufficiency as well as hazard computability, and thereby is appropriate for use in the prediction of seismic response of single-layer reticulated domes.

정전 용량성 결합 전극을 이용한 웨어러블 심전도 측정 시스템 설계에 관한 연구 (Study of the Wearable Electrocardiogram Measuring System using Capacitive-coupled Electrode)

  • 이재호;이영재;이강휘;강승진;김경남;박희정;이정환
    • 전기학회논문지
    • /
    • 제63권10호
    • /
    • pp.1448-1454
    • /
    • 2014
  • In this study, a new type of electrode device is implemented to measure the capacitance energy and interpret it as the ECG (Electrocardiogram) data. The main idea of this new electrode system is to estimate the capacitance on the skin by assembling a capacitive-coupled circuits and translate into the ECG signal. To measure the coupling energy and estimate the aquired data in terms of heart activity, the capacitive-coupled electrode is garmented with fabrics in the form of a chest band or a vest jacket. To compare the ECG data from the capacitive-coupled electrode with the conventional electrode(Ag-AgCl) system, the corelation coefficient between two signals is computed as 0.9517. Thus, we can conclude the fact that capacitive-coupled electrode system can measure a person's heart activity without any contact to his or her skin and can the interpreted as the ECG data.

ROSA/LSTF Test and RELAP5 Analyses on PWR Cold Leg Small-Break LOCA with Accident Management Measure and PKL Counterpart Test

  • Takeda, Takeshi;Ohtsu, Iwao
    • Nuclear Engineering and Technology
    • /
    • 제49권5호
    • /
    • pp.928-940
    • /
    • 2017
  • An experiment using the $Prim{\ddot{a}}rkreisl{\ddot{a}}ufe$ Versuchsanlage (PKL) was performed for the OECD/NEA PKL-3 Project as a counterpart to a previous test with the large-scale test facility (LSTF) on a cold leg smallbreak loss-of-coolant accident with an accident management (AM) measure in a pressurized water reactor. Concerning the AM measure, the rate of steam generator (SG) secondary-side depressurization was controlled to achieve a primary depressurization rate of 200 K/h as a common test condition; however, the onset timings of the SG depressurization were different from each other. In both tests, rapid recovery started in the core collapsed liquid level after loop seal clearing, which caused whole core quench. Some discrepancies appeared between the LSTF and PKL test results for the core collapsed liquid level, the cladding surface temperature, and the primary pressure. The RELAP5/MOD3.3 code predicted the overall trends of the major thermal-hydraulic responses observed in the LSTF test well, and indicated a remaining problem in the prediction of primary coolant distribution. Results of uncertainty analysis for the LSTF test clarified the influences of the combination of multiple uncertain parameters on peak cladding temperature within the defined uncertain ranges.

수소 가스 검출용 라만 라이다 측정기의 성능 평가를 위한 기초 연구 (A Basic Study for the Performance Evaluation of a Raman LiDAR Detector for Detecting Hydrogen Gas)

  • 조원보;임윤규;김양균;박병직
    • 한국수소및신에너지학회논문집
    • /
    • 제34권2호
    • /
    • pp.205-211
    • /
    • 2023
  • Hydrogen gas is light and diffuses very quickly. Therefore, when a leakage accident occurs, the damage is great, so a technology that can quickly measure the leakage in the air at a long distance is needed. In order to develop hydrogen gas leaked in the atmosphere in a non-contact manner, an experiment was performed to measure hydrogen gas using a lidar technology using the Raman effect. Hydrogen Raman signals were detected using a UV LED light source, which is a Raman light source, and a spectrometer in the ultraviolet region including an optical filter in the 400-430 nm band. To develop this, a Raman lidar optical structure was designed to measure the hydrogen Raman signal at a certain distance, and the hydrogen Raman spectrum was confirmed using a standard gas to evaluate the performance of this optical structure. The linearity was found to be 0.99 using hydrogen standard gas (10, 50, 100, 500, 1,000 ppm). Accordingly, a Raman lidar capable of measuring hydrogen gas rapidly diffusing in the air in an open state was developed to improve the limitations of existing hydrogen sensors.

노이즈에 둔감한 밴드패스 이산 코사인 초점 값 연산자 (Mid frequency - DCT focus measure operator for the robust autofocus)

  • 이상용;박상수;김수원
    • 대한전자공학회논문지SD
    • /
    • 제43권12호
    • /
    • pp.8-14
    • /
    • 2006
  • 본 논문에서는 노이즈에 둔감한 4*4 밴드패스 이산 코사인 (MF-DCT) 초점 값 연산자를 제안하였다. 제안된 연산자는 DCT 결과 중 중간 주파수 성분을 사용하는 8*8 MDCT 연산자를 노이즈에 둔감하도록 4 형태로 개선한 것으로써 연산자를 180도 회전하여도 같은 구조를 같도록 하였다. 이 연산자는 샘플링 주파수의 절반 부분지 주파수를 통과시키는 밴드패스 필터와 같이 동작하여 초점 정보를 가지고 있지 않는 저주파 신호와 노이즈에 의해 많은 영향을 받는 고주파 신호를 억제함으로써 노이즈에 둔감한 특성을 가진다. 또한 밴드패스 필터를 통과한 성분의 에너지를 초점 값으로 사용함으로써 초점 합의 선형성을 보장받게 된다. 실험 결과에서는 MF-DCT 연산자의 가우시안 노이즈 및 임펄시브 노이즈 특성을 살펴보기 위해 기존의 초점 값 연산자들과의 Autofocusing Uncertain Measure (AUM)비교를 통해 우수성을 검증하였다.