• 제목/요약/키워드: Mean peak pressure

검색결과 194건 처리시간 0.03초

Effects of quadriceps angle on patellofemoral contact pressure

  • Yoo, Yoon-Hyeong;Lee, Sung-Jun;Jeong, Soon-wuk
    • Journal of Veterinary Science
    • /
    • 제21권5호
    • /
    • pp.69.1-69.11
    • /
    • 2020
  • Background: An inappropriate Q angle may affect the biomechanics of the canine patellofemoral joint. Objectives: The purpose of this study was to evaluate the effects of changes in quadriceps angle (Q angle) on patellofemoral joint pressure distribution in dogs. Methods: Eight stifles were positioned at 45, 60, 75, 90, 105, and 120° of flexion in vitro, and 30% body weight was applied through the quadriceps. Patellofemoral contact pressure distribution was mapped and quantified using pressure-sensitive film. For the pressure area, mean pressure, peak pressure, medial peak pressure, and lateral peak pressure, differences between groups according to conditions for changing the Q angle were statistically compared. Results: Increases of 10° of the Q angle result in increases in the pressure area (P = 0.04), mean pressure (P = 0.003), peak pressure, and medial peak pressure (P ≤ 0.01). Increasing the Q angle by 20° increases the pressure area (P = 0.021), mean pressure (P ≤ 0.001), peak pressure (P ≤ 0.01), and medial peak pressure (P ≤ 0.01) significantly, and shows higher mean (P ≤ 0.001) and peak pressures than increasing by 10°. Decreasing the Q angle increases the mean pressure (P = 0.013), peak pressure, and lateral peak pressure (P ≤ 0.001). Conclusions: Both increases and decreases in the Q angle were associated with increased peak patellofemoral pressure, which could contribute to the overloading of the cartilage. Therefore, the abnormal Q angle should be corrected to the physiologically normal value during patellar luxation repair and overcorrection should be avoided.

경중족 절단 환자의 의족지 착용에 따른 족저압력 분포 특성 (Characteristics of Foot Pressure Distribution with or without Partial Prosthetic Foot in Transmetartarsal Amputee)

  • 성우성;양희승;성홍기;김학준
    • 대한족부족관절학회지
    • /
    • 제12권1호
    • /
    • pp.41-46
    • /
    • 2008
  • Purpose: This study was designed to evaluate characteristics of foot pressure distribution with or without partial prosthetic foot in transmetatarsal amputee. Materials and Methods: The subjects were 9 transmetatarsal amputees. Foot pressures were measured at hallux, the $1^{st}-5^{th}$ metatarsal head (MTH), mid-foot, condyle area by F-scan system in amputated or contralateral foot during active walking. Results: In amputated foot, mean peak pressure was greatest in midfoot without prosthetic foot but it was greatest in hindfoot with prosthetic foot. In unaffected foot, although mean peak pressure was higher in hallux, and $1-5^{th}$ MTH compared to amputated foot, it was greatest in hind foot both with and without prosthetic foot. However, in unaffected foot, mean peak pressure significantly decreased in hallux and $5^{th}$ MTH after wearing the prosthetic foot. There was a significant difference in mean peak pressure in hallux and $5^{th}$ MTH between amputated and unaffected foot after wearing prosthetic foot. However, other region had no significant difference with or without prosthetic foot between feet. Conclusions: The use of partial prosthetic foot tends to shift weight bearing from the heel area to forefoot and could significantly reduce hind foot peak pressure and redistributed to peak pressure. The partial prosthetic foot can also offer the peak pressure to reduction both amputated foot and unaffected foot and help to toe off during walking.

  • PDF

중족골 바 형태의 전족부 라커 신발이 하지 근 활성도 및 족저압력 분포에 미치는 영향 (Effects of Forefoot Rocker Shoes with Metatarsal Bar on Lower Extremity Muscle Activity and Plantar Pressure Distribution)

  • 박인식;정지용;전근환;원용관;김정자
    • 한국운동역학회지
    • /
    • 제22권1호
    • /
    • pp.113-121
    • /
    • 2012
  • The purpose of this study was to evaluate the effects of forefoot rocker shoes equipped with a metatarsal bar on lower extremity muscle activity and plantar pressure distribution. Ten healthy women in the age of twenties were participated in this study as the subjects. All subjects walked on a treadmill(Gait Trainer, BIODEX, USA) wearing normal shoes and metatarsal bar shoes, during which the plantar pressure distribution and muscle activity were measured. Using Pedar-X system(Novel Gmbh, Germany), the plantar pressure was measured for six regions of the foot: forefoot, midfoot, rearfoot, 1st metatarsal, 2-3th metatarsal, and 4-5th metatarsal, and for each sub-region, 4 features such as maximum force, contact area, peak pressure, and mean pressure were analyzed based on the plantar pressure. EMG(Electromyography) activity was measured by attaching surface electrodes to the rectus femoris, biceps femoris, tibialis anterior, and gastrocnemius medial head, and magnitude of muscle contraction was analyzed in IEMG(Integrated EMG) value. The results show that the maximum force, contact area, peak pressure, and mean pressure in the midfoot all increased while maximum force, peak pressure, contact area, mean pressure in the 1st metatarsal and 2-3th metatarsal all decreased when wearing functional shoes. Also, muscle activities in the four muscles were all decreased when wearing the functional shoes. This paper suggests that forfoot rocker shoes equipped with a metatarsal bar can help disperse the high pressure and absorb the shock to the foot as well as give positive influence on gait pattern and postural stability by reducing muscle fatigue during walking.

편평족 노인의 계단 하강 보행 시 아치 지지형 인솔 종류에 따른 족저압력 및 균형성 평가 (Comparison of plantar pressure and COP parameters in three types of arch support insole during stair descent in elderly with flatfoot)

  • 한기훈;배강호;정하곤;하민성;최도열;이중숙;양정옥
    • 한국응용과학기술학회지
    • /
    • 제35권3호
    • /
    • pp.948-955
    • /
    • 2018
  • 본 연구의 목적은 평발을 가진 여성 노인의 계단 하강 보행 시 일반인솔 및 아치 지지형 인솔을 적용에 따른 족저압력 및 압력중심점 변인들의 차이를 조사하는데 목적이 있다. 족저압력 분석장비(Pedar-X, Novel, Germany)를 사용하여 14명의 평발 노인을 대상으로 3종류(일반인솔, A형 인솔, B형 인솔)의 인솔착용 후 최대족저압력, 평균족저압력, 접촉면적, 압력중심점의 이동거리, 변위 및 최대범위의 평균값을 산출하였으며, 일원변량분석(one-way ANOVA)를 이용하여 인솔 종류간 평균을 비교하였다. 족저 압력 변인 중 최대족저압력은 중족부의 M3, 평균족저압력은 M2, M3, M4 영역에서, 접촉면적은 M2, M3, 그리고 M6 영역에서 통계적으로 유의한 차이를 보였으며, 압력중심점 변인 중 전후축과 좌우축에서 압력중심점의 이동거리에서 통계적으로 유의한 차이를 보였다. 족저압력 평가결과 아치 지지 기능을 가진 인솔을 삽입한 A와 B형 인솔에서 족궁지지 영역인 M3의 최대압력은 B형 인솔과 A형 인솔이 일반인솔과 비교했을 때 높게 나타났다. 좌우축, 전후축 압력중심점의 이동거리는 A형과 B형 인솔 모두 일반 인솔에 비해 짧게 나타났다.

한국어 파열음의 발성 유형에 따른 공기역학 측정치 비교 (The Comparison of Aerodynamic Measures in Korean Stop Consonants based on Phonation Types)

  • 최성희;최철희
    • 말소리와 음성과학
    • /
    • 제6권4호
    • /
    • pp.195-203
    • /
    • 2014
  • The aim of this study was to investigate the effects of phonation types ([+/- aspirated], [+/- fortis]) on aerodynamic measures with Korean bilabial stops. Sixty-three healthy young adults (30 males, 33 females) participated to evaluate the VOEF (Voicing Efficiency) tasks with bilabial stop consonants /$p^h$/, /p/, /p'/ using Phonatory Aerodynamic System (PAS) Model 6600 (Kay PENTAX Corp, Lincoln Park, NJ). All VOEF measures were significantly influenced by phonation types except RANP(pitch range)(p <.01). For sound pressure, maximum SPL, mean SPL, and Mean SPL during Voicing have been shown to be significantly greatest in fortis stop /p'/ than aspirated /$p^h$/ and lenis stop /p/ (p<.001). On the other hand, mean pitch after lenis stop was significantly lower than after aspirated and fortis stops (p<.001). Peak expiratory airflow, Target airflow, and FVC (Expiratory volume) were significantly lowest in fortis stop /p'/ which might be associated with higher aerodynamic resistance while peak air pressure and mean peak air pressure during closure were significantly lower in lenis stop /p/. Additionally, AEFF (Aerodynamic efficiency) was significantly higher in fortis stop /p'/ than lenis stop /p/ as well as aspirated stop /$p^h$/ (p<.001). Thus, sound pressure, airflow parameters, and aerodynamic resistance made crucial roles in distinguishing fortis /p'/ from lenis stop /p/ and aspirated. Additionally, pitch and subglottal air pressure parameters were important aerodynamic characteristics in distinguishing lenis /p/ from fortis /p'/ and aspirated /$p^h$/. Therefore, accurate aspirated /p/ stop consonant should be elicited when collecting the airflow, intraoral pressure related data with patients with voice disorders in order to enhance the reliability and relevance or validity of aerodynamic measures using PAS.

Investigation of surface pressures on CAARC tall building concerning effects of turbulence

  • Li, Yonggui;Yan, Jiahui;Chen, Xinzhong;Li, Qiusheng;Li, Yi
    • Wind and Structures
    • /
    • 제31권4호
    • /
    • pp.287-298
    • /
    • 2020
  • This paper presents an experimental investigation on the surface pressures on the CAARC standard tall building model concerning the effects of freestream turbulence. Two groups of incidence turbulence are generated in the wind tunnel experiment. The first group has an approximately constant turbulence intensity of 10.3% but different turbulence integral scale varying from 0.141 m to 0.599 m or from 0.93 to 5.88 in terms of scale ratio (turbulence integral scale to building dimension). The second group presents similar turbulence integral scale but different turbulence intensity ranging from 7.2% to 13.5%. The experimental results show that the mean pressure coefficients on about half of the axial length of the side faces near the leading edge slightly decrease as the turbulence integral scale ratio that is larger than 4.25 increases, but respond markedly to the changes in turbulence intensity. The root-mean-square (RMS) and peak pressure coefficients depend on both turbulence integral scale and intensity. The RMS pressure coefficients increase with turbulence integral scale and intensity. As the turbulence integral scale increases from 0.141 m to 0.599 m, the mean peak pressure coefficient increases by 7%, 20% and 32% at most on the windward, side faces and leeward of the building model, respectively. As the turbulence intensity increases from 7.2% to 13.5%, the mean value of peak pressure coefficient increases by 47%, 69% and 23% at most on windward, side faces and leeward, respectively. The values of cross-correlations of fluctuating pressures increase as the turbulence integral scale increases, but decrease as turbulence intensity increases in most cases.

Effect of building volume and opening size on fluctuating internal pressures

  • Ginger, John D.;Holmes, John D.;Kopp, Gregory A.
    • Wind and Structures
    • /
    • 제11권5호
    • /
    • pp.361-376
    • /
    • 2008
  • This paper considers internal pressure fluctuations for a range of building volumes and dominant wall opening areas. The study recognizes that the air flow in and out of the dominant opening in the envelope generates Helmholtz resonance, which can amplify the internal pressure fluctuations compared to the external pressure, at the opening. Numerical methods were used to estimate fluctuating standard deviation and peak (i.e. design) internal pressures from full-scale measured external pressures. The ratios of standard deviation and peak internal pressures to the external pressures at a dominant windward wall opening of area, AW are presented in terms of the non-dimensional opening size to volume parameter, $S^*=(a_s/\bar{U}_h)^2(A_W^{3/2}/V_{Ie})$ where $a_s$ is the speed of sound, $\bar{U}_h$ is the mean wind speed at the top of the building and $V_{Ie}$ is the effective internal volume. The standard deviation of internal pressure exceeds the external pressures at the opening, for $S^*$ greater than about 0.75, showing increasing amplification with increasing $S^*$. The peak internal pressure can be expected to exceed the peak external pressure at the opening by 10% to 50%, for $S^*$ greater than about 5. A dominant leeward wall opening also produces similar fluctuating internal pressure characteristics.

Pressure Distribution in Stump/Socket Interface in Response to Socket Flexion Angle Changes in Trans-Tibial Prostheses With Silicone Liner

  • Kang, Pil;Kim, Jang-Hwan;Roh, Jung-Suk
    • 한국전문물리치료학회지
    • /
    • 제13권4호
    • /
    • pp.71-78
    • /
    • 2006
  • This study examined the effects of socket flexion angle in trans-tibial prosthesis on stump/socket interface pressure. Ten trans-tibial amputees voluntarily participated in this study. F-socket system was used to measure static and dynamic pressure in stump/socket interface. The pressure was measured at anterior area (proximal, middle, and distal) and posterior area (proximal, middle, and distal) in different socket flexion angles ($5^{\circ}$, $0^{\circ}$, and $10^{\circ}$). Paired t-test was used to compare pressure differences in conventional socket flexion angle of $5^{\circ}$ with pressures in socket flexion angles of $0^{\circ}$ and $10^{\circ}$ (${\alpha}$=.05). Mean pressure during standing in socket flexion angle of $10^{\circ}$ decreased significantly in anterior middle area (19.7%), posterior proximal area (10.4%), and posterior distal area (16.3%) compared with socket flexion angle of $5^{\circ}$. Mean pressure during stance phase in socket flexion angle of $0^{\circ}$ increased significantly in anterior proximal area (19.3%) and decreased significantly in anterior distal area (19.7%) compared with socket flexion angle of $5^{\circ}$. Mean pressure during stance phase in socket flexion angle of $10^{\circ}$ decreased significantly in anterior proximal area (19.6%) and increased significantly in anterior distal area (8.2%) compared with socket flexion angle of $5^{\circ}$. Peak pressure during gait in socket flexion angle of $0^{\circ}$ increased significantly in anterior proximal area (23.0%) compared with socket flexion angle of $5^{\circ}$ and peak pressure during gait in socket flexion angle of $10^{\circ}$ decreased significantly in anterior proximal area (22.7%) compared with socket flexion angle of $5^{\circ}$. Mean pressure over 80% of peak pressure ($MP_{80+}$) during gait in socket flexion angle of $0^{\circ}$ increased significantly in anterior proximal area (23.9%) and decreased significantly in anterior distal area (22.5%) compared with socket flexion angle of $5^{\circ}$. $MP_{80+}$ during gait in socket flexion angle of $10^{\circ}$ decreased significantly in anterior distal area (34.1%) compared with socket flexion angle of $5^{\circ}$. Asymmetrical pressure change patterns in socket flexion angle of $0^{\circ}$ and $10^{\circ}$ were revealed in anterior proximal and distal region compared with socket flexion angle of $5^{\circ}$. To provide comfortable and safe socket for trans-tibial amputee, socket flexion angle must be considered.

  • PDF

음성학적 문맥에 따른 성문하압의 차이에 관한 연구 (Subglottic Air Pressure in Different Phonetic Context)

  • 박상희;정옥란;석동일
    • 대한후두음성언어의학회지
    • /
    • 제13권1호
    • /
    • pp.23-27
    • /
    • 2002
  • The purpose of the study is to examine differences in subglottic air pressure as a function of phonetic context. The phonetic contexts consisted of $/i:{p^h}i:{p^h}i:/,/{p^h}i:{p^h}i:/, and /{p^h}{p^h}/$. The aerodynamic and phonatory parameters are investigated in 20 female normal adults. All measurements are taken and analysed using Aerophone II voice function analyzer. The aerodynamic parameters are Peak Air Pressure(PAP) and Mean Air Pressure(MAP), and the phonatory parameters are Phonatory Flow Rate(PFR) Maximum SPL(MSPL), Phonatory SPL(PSPL), Phonatory Power (PP), Phonatory Efficiency(PE), and Phonatory $Resistance^*$ 10-5(PR). A one-way ANOVA revealed the following results. First, the aerodynamic parameters are not significantly different. Second, Peak Air Pressure(PAP) and Mean Air Pressure(MAP), as well as the phonatory parameters such as Phonatory Flow Rate(PFR) Maximum SPL(MSPL), Phonatory SPL(PSPL), and Phonatory Efficiency(PE) were significantly different. Therefore, it is advised that clinicians use only aerodynamic parameters but phonatory parameters when using Aerophone II.

  • PDF

Wind flow characteristics and their loading effects on flat roofs of low-rise buildings

  • Zhao, Zhongshan;Sarkar, Partha P.;Mehta, Kishor C.;Wu, Fuqiang
    • Wind and Structures
    • /
    • 제5권1호
    • /
    • pp.25-48
    • /
    • 2002
  • Wind flow and pressure on the roof of the Texas Tech Experimental Building are studied along with the incident wind in an effort to understand the wind-structure interaction and the mechanisms of roof pressure generation. Two distinct flow phenomena, cornering vortices and separation bubble, are investigated. It is found for the cornering vortices that the incident wind angle that favors formation of strong vortices is bounded in a range of approximately 50 degrees symmetrical about the roof-corner bisector. Peak pressures on the roof corner are produced by wind gusts approaching at wind angles conducive to strong vortex formation. A simple analytical model is established to predict fluctuating pressure coefficients on the leading roof corner from the knowledge of the mean pressure coefficients and the incident wind. For the separation bubble situation, the mean structure of the separation bubble is established. The role of incident wind turbulence in pressure-generation mechanisms for the two flow phenomena is better understood.