• 제목/요약/키워드: Mean age of air

검색결과 188건 처리시간 0.025초

냉방시 시스템에어컨과 환기유닛 적응 강의실에서 실내 $CO_2$ 농도와 국소평균공기연령 연구 (Study on the Relationship between Indoor $CO_2$ Concentration and Local Mean Air-age in the Lecture Room with System Air-conditioner and Ventilation Unit for Cooling Loads)

  • 장재수;노광철;오명도
    • 설비공학논문집
    • /
    • 제17권8호
    • /
    • pp.736-745
    • /
    • 2005
  • This study is undertaken to evaluate the relationship between the indoor $CO_2$ concentration and the local mean air-age in the lecture room with the occupants. We conducted the experiments to examine the indoor $CO_2$ concentration and the local mean air-age with respect to the supply airflow of the ventilation system and the discharge angle and air-flow of the system air conditioner. Through the experiments, we found out that indoor $CO_2$ concentrations calculated by the prediction equation of Seidel are about 350 ppm lower than those measured by the experiments. The indoor $CO_2$ concentration is not related with the air-flow and the discharge angle of the system air-conditioner, but with the ventilation airflow. From the numerical calculation, the indoor $CO_2$ concentration is not related with the ventilation effectiveness, but strongly with the local mean air-age. In case of our model, the indoor $CO_2$ concentration is likely to fall within the acceptable air quality when the local mean air-age is averagely predicted under 400 seconds.

Distributions of Local Supply and Exhaust Effectiveness according to Room Airflow Patterns

  • Han, Hwa-Taik;Choi, Sun-Ho;Lee, Woo-Won
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권4호
    • /
    • pp.177-183
    • /
    • 2002
  • A pulsed tracer gas technique is applied to measure the distributions of local mean age and local mean residual-life-time of air in a half-scale experimental chamber, The airflow patterns in the chamber are visualized by a Helium bubble generator for three different exhaust locations. A supply slot is located at the top of a right wall, and an exhaust slot is at either bottom-left (Case 1), bottom-right (Case 2), or top-left (Case 3) location. Results show that the distributions of local mean age and local mean residual-life-time are different from each other, but both of them are closely related to the airflow pattern in the space. Included are discussions on explaining the variations of overall room ventilation effectiveness depending upon airflow rates for three different supply-exhaust configurations.

벽체 매립형 환기용 팬 성능개선에 관한 연구 (Study on the Performance Improvement of Ventilation Fan Installed in Walls of Underground Parking Lots)

  • 권용일
    • 설비공학논문집
    • /
    • 제26권5호
    • /
    • pp.206-211
    • /
    • 2014
  • The objective of the present study was to identify ventilation problems, and also to suggest new axial fan systems for the improvement of IAQ in the underground parking lots. Numerical results for air mean-velocity, local mean age, and sound power level are presented along with some of fan angles. The results showed the influence of airflow patterns on the fan performances installed in the underground parking lots. Discharge air volume is increased with the angle of the blade. And also, the main factors affecting the noise of the ventilation fan was found to be a rotational speed.

Developmental and Environmental Sources of Variation on Annual Growth Increments of Ascophyllum nodosum (Phaeophyceae)

  • Eckersley, Lindsay K.;Garbary, David J.
    • ALGAE
    • /
    • 제22권2호
    • /
    • pp.107-116
    • /
    • 2007
  • Annual growth segments of Ascophyllum nodosum (L.) Le Jolis (Fucales, Fucaceae) are denoted by air bladders that form each spring. By examining annual growth segments, it may be possible to infer information about the physical conditions during the growth period; however, it is uncertain whether the annual segments will expand in size after the initial growth. We examined A. nodosum segments from three populations in Nova Scotia, and statistically evaluated whether the annual growth (length, mass, and maximum diameter) of segments was independent of the age of the frond, whether the segments increased in size after the initial growth, and whether the segment lengths were correlated with mean water temperatures and mean air temperatures when the segments were formed. We found that the growth in length of A. nodosum is dependent on the age of the frond, but frond age explained less than 12 % of the overall variation in length. However, the mass and maximum diameter of segments were independent of the age of the frond. Differences occurred between the lengths of segments formed in different years, but there was no significant correlation with regional mean water or air temperatures. This study indicates that the length of A. nodosum segments may be an indicator of the annual physical characteristics of a site, but future studies are needed to identify which factors have the strongest influence on growth patterns.

난류유동해석을 통한 환기효율의 수치해석적 연구 (Numerical Analysis of Ventilation Effectiveness using Turbulent Airflow Modeling)

  • 한화택
    • 설비공학논문집
    • /
    • 제4권4호
    • /
    • pp.253-262
    • /
    • 1992
  • A numerical procedure is introduced to calculate local ventilation effectiveness using the definitions of local decay rate and local mean age. A low Reynolds number $k-{\varepsilon}$ model is implemented to calculate steady state turbulent velocity distributions, and a step-down method is used to calculate transient concentration distributions. Simulations are carried out for several different values of air change rates and several different diffuser angles in a two-dimensional model of a half scale office room. The results show that the local ventilation effectiveness within a room could vary significantly from one location to another. The nominal air change rate based on the assumption of complete mixing of room air does not provide the local ventilation effectiveness information. It is numerically proved that the local mean age distribution obtained from the transient calculation is equivalent to the steady state concentration distribution with homogeneously distributed contaminant sources.

  • PDF

실내 기류패턴에 따른 급기효율과 배기효율의 분포 (Distributions of Local Supply and Exhaust Effectiveness according to the Room Airflow Patterns)

  • 한화택;최선호;장경진
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.853-859
    • /
    • 2001
  • A pulsed tracer gas technique is applied to measure distributions of local mean age and residual life time of air in a half-scale experimental chamber. The room airflow patterns are flow-visualized by a Helium bubble generator for three different exhaust locations. A supply slot is located at the top of a right wall, and an exhaust slot is either at bottom-left(Case 1), bottom-right(Case 2), or top-left(Case 3) location. Results show that the distribution of LMA and LMR are different from each other, but both of them are closely related to the airflow pattern in the space. Results on overall room ventilation effectiveness are provided depending upon ventilation airflow rates for three different supply-exhaust configurations.

  • PDF

Measurements of Ventilation Effectiveness in an Underfloor Air-Conditioned Space Using a Tracer Gas Technique

  • Han, Hwa-Taik;Seo, S.Y.;Kim, M.H.;Kim, Young-Il
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제7권
    • /
    • pp.91-100
    • /
    • 1999
  • This paper investigates ventilation characteristics of an environmental chamber simulating an under-floor air conditioning system for isothermal and cooling supply air conditions. The tracer gas sulfur-hexafluoride (SF$F_6$) was injected into a supply duct using step-up and step-down methods. Local mean and room mean ages were calculated from the concentrations measured at internal points and at the exhaust duct. The air change efficiency of the chamber has been found to be greater in cooling conditions than in isothermal conditions. Also the room air change efficiency is not significantly affected but slightly improved by the presence of a supply diffuser.

  • PDF

국소평균공기연령을 이용한 국소환경시스템의 청정도 평가 및 예측 (Evaluation and Prediction of Cleanliness Level in the Mini-Environment System Using Local Mean Air-Age)

  • 노광철;이현철;박정일;오명도
    • 대한기계학회논문집B
    • /
    • 제31권5호
    • /
    • pp.457-466
    • /
    • 2007
  • A numerical and experimental study on the evaluation and the prediction of cleanliness level in the mini-environment system was carried out. Using the concept of local mean air-age (LMA) and effective flow rate, the new direct method for estimating the mini-environment was developed and compared with the previous performance index of airflow pattern characteristics. It was found out that the airflow pattern analysis is a restricted method to estimate the real performance of the mini-environment. The reason is that the airflow pattern cannot predict the effect of the increment of the ventilation rate on the cleanliness level in the mini-environment. While LMA is capable of showing the effects of the contaminant accumulation caused by turbulent intensity, eddy, and the increment of the effective flow rate. This result showed that LMA is more exact and effective performance index than the previous one like the airflow pattern characteristics.

대전지역 대기오염물질농도와 천식 환자수의 관련성 (Concentration of Air Pollutants and Asthma in Taejon City)

  • 서원호;장성실;권호자
    • 한국환경보건학회지
    • /
    • 제26권2호
    • /
    • pp.80-90
    • /
    • 2000
  • To determine the effect of air pollutants in Taejon City, we used medical insurance claim data for asthma and the data monitored from telemetry system of Ministry of Environment for air pollutants and meteorological factors. From November 1st, 1997 to October 31th, 1998, 95,629 asthma patients were covered by medical insurance at Taejon City. Subjects were composed of 49,563 males (51.8%) and 46.336 females(48.2%), and among the subjects, the proportion under 15 years old was 62.8% of the total. During the study period, daily mean concentrations of each air pollutants-So2, No2, CO, O3 and TSP-were 9.8 ppb, 17.6 ppm, 1.414 pp, 17.3 ppb and 60.6 $\mu\textrm{g}$/㎥, respectively, which were lower than each of the environmental recommended exposure levels, Through the simple correlation analysis between each air pollutants and meteorological factors, O3 was positively correlated with temperature, but negatively with relative humidity. TSP, SO2, NO2, CO were negatively correlated with meteorological factors, and these air pollutants except O3 were positively correlated with each other, O3 was correlated with TSP positively but the others negatively. Estimating relative risks of each air pollutant with the baseline general additive model, daily mean concentrations of TSP(Lag 0, 1, 4, 5day) were significantly associated with the increase of the asthma admission. Two age subgroups, under 15 and 15~54 have shown various association of all air pollutants concentration with the asthma admission. However, in case of over 54 age subgroup, only TSP(Lag 0 day) among all air pollutants was associated with the asthma admission. Each of ambient outdoor pollutant concentrations in Taejon City are significantly associated with the admission of asthma patients even though all concentrations in Taejon City are significantly associated with the admission of asthma patients even though all concentrations were much lower than the environmental recommended exposure levels. Therefore, continuous effort lowering air pollutant concentration and introducing an active environmental conservation policy should be implanted for preventing hazardous health effects. Considering major proportion of asthma admissions, high susceptibility and less confounding factors among the age subgroup under 15 will be a useful target population for assessing such health effect monitoring.

  • PDF

Numerical study of wind profiles over simplified water waves

  • Cao, Shuyang;Zhang, Enzhen;Sun, Liming;Cao, Jinxin
    • Wind and Structures
    • /
    • 제21권3호
    • /
    • pp.289-309
    • /
    • 2015
  • Vertical profiles of mean and fluctuating wind velocities over water waves were studied, by performing Large-Eddy Simulations (LES) on a fully developed turbulent boundary layer over simplified water waves. The water waves were simplified to two-dimensional, periodic and non-evolving. Different wave steepness defined by $a/{\lambda}$ (a : wave amplitude; ${\lambda}$ : wavelength) and wave age defined by $c/U_b$ (c: phase velocity of the wave; $U_b$ : bulk velocity of the air) were considered, in order to elaborate the characteristics of mean and fluctuating wind profiles. Results shows that, compared to a static wave, a moving wave plays a lesser aerodynamic role as roughness as it moves downstream slower or a little faster than air, and plays more aerodynamic roles when it moves downstream much faster than air or moves in the opposite direction to air. The changes of gradient height, power law index, roughness length and friction velocity with wave age and wave amplitude are presented, which shed light on the wind characteristics over real sea surfaces for wind engineering applications.