• 제목/요약/키워드: Mean Pressure Control

검색결과 486건 처리시간 0.027초

구개열 환자의 비인강폐쇄 기능에 대한 공기역학적 연구 (An Aerodynamic Study of Velopharyngeal Closure Function in Cleft Palate Patients)

  • 안태섭;양상일;신효근
    • 음성과학
    • /
    • 제1권
    • /
    • pp.237-259
    • /
    • 1997
  • Cleft Palate speech appears to have hyper/hyponasality with velopharyngeal insufficiency and articulation disorders. Previous studies on Cleft Palate speech have shown that speech tends to have lower airflow and air pressure. To examine the aerodynamic characteristics of Cleft Palate speech, Aerophone II Voice function Analyzer was used. We measured sound pressure level, airflow, air pressure and glottal power. Three Cleft Palate adults and five normal adults participated in this experiment. The test words are composed of: (1) the sustained vowel /o/ (2) /CiCi/, where C is one of three different stop consonants in Korean (3) /bimi/. Subjects were asked to produce /bimi/ five times without opening their lips. All the data was statistically tested by t-test for Cleft Palate patients before operation groups and control groups and paired t-test for Cleft Palate patients before and after operation groups. The results were as follow: (1) Cleft Palate patients generally speak with incomplete oral closure and lower oral air pressure. As a result, the SPL of Cleft Palate before operation is 3 dB lower than control groups. (2) Airflow of Cleft Palate in phonation and articulation is lower than that of control groups. However, it increased after operation. Lung volume and mean airflow in phonation are significantly increased (p<0.05). (3) Although velopharyngeal function (velar opening rate) of Cleft Palate is poor in comparison with control groups, it was recovered after operation. In this event maximum flow rate and mean airflow rate are significantly increased (p<0.05). (4) Air pressure of Cleft Palate in speech is lower than that of control groups. In general, the air pressure of Cleft Palate increased after operation. In this event air pressure of glottalized consonant is significantly increased (p<0.04). (5) Glottal Power(mean power, mean efficient and mean resistant) of Cleft Palate patients is lower than that of control groups. But mean efficient and mean resistant of Cleft Palate patients increased significantly (p<0.05) after operation.

  • PDF

고속 온-오프 전자 밸브를 사용한 유압 실린더의 압력 제어 (Pressure Control of Hydraulic Cylinder using high Speed On-Off Solenoid Valve)

  • 김상수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권1호
    • /
    • pp.69-78
    • /
    • 1999
  • In this study a new pattern of pressure control of hydraulic cylinder using high speed On-Off solenoid valve in the electro-hydraulic system has been suggested. The control valve is 3-way high speed On-Off solenoid valve which is operated by PWM(Pulse Width Modulation)control signal. The high speed On-Off solenoid valve has a tendency to induce severe pressure fluctuation in the hydraulic actuator so it has not been used for the purpose of closed loop control with direct pres-sure feedback. In this study closed loop control with direct pressure feedback is enabled by using a digital filter which has linear minimum mean square filter algorithm. Through some experiments it is confirmed that stable pressure control can be realized by the proposed control technique.

  • PDF

개폐식 3방향 전자밸브의 펄스폭 변조 구동에 의한 압력제어 특성에 관한 연구 (A Study on the Pressure Control Characteristics of ON/OFF 3-way Solenoid Valve Driven by PWM Signal)

  • 정헌술
    • 대한기계학회논문집A
    • /
    • 제21권3호
    • /
    • pp.485-501
    • /
    • 1997
  • Pressure control is possible driving a simple ON/OFF 3-way valve of hydraulic servo system by pulse width modulation signal. But the pressure varies according to the duty ratio and carrier frequency and repeated on-off action induces pressure fluctuation. So equations for mean pressure and ripple amplitude are theoretically derived as a function of on/off time, the system parameters which decide the pressure characteristics are arranged and they are verified by experimental study. As the result selection criteria for the major design parameters are established and the basic strategy to suppress the unnecessary fluctuation can be provided for a hydraulic pressure control system using these type of valves.

2방향 전자밸브 PWM압력제어특성의 실험적 비교연구 (Experimental Study on the PWM Pressure Control Characteristics of 2 Way Solenoid Valve)

  • 정헌술;박성진;김창완
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.107-111
    • /
    • 1997
  • Pressure control is possible by pulse width modulation signal driving a simple ON/OFF 2-way valve of hydraulic servo system. But it indices pressure fluctuation due to repeated on-off action and the pressure varies according to the duty ratio and carrier frequency. So mean pressure and ripple amplitude are arranged by experimental study as the driving signal change which decides the pressure characteristics. As the result selection criteria of the major design parameters may be established and the basic strategy to suppress the unnecessary flucturion may be provided for a hydraulic pressure control system.

  • PDF

음향 인텐시티를 이용한 관 외부 방사 소음의 능동 제어 (Active Control of External Noise Radiated From Duct Using Sound Intensity)

  • 강성우;김양한
    • 소음진동
    • /
    • 제7권3호
    • /
    • pp.427-437
    • /
    • 1997
  • Mean active intensity based active control for the cancellation of radiated noise out of the duct exit is studied. The active intensity control strategy is drerived based on the relation of the exterior sound field out of the duct termination and interior sound field of the duct. One of the characteristics of this control strategy is that the control performance can be maintained regardless of the sensor loction, compared with the conventional local pressure control methods at either interior downstream or exterior field positions. It is also suggested that the digital filtering for the active intensity control can be achieved by time-domain filtered-x LMP (Lest-Mean-Product) adaptive algorithm. Experiments for an open-ended duct are performed to compare the active intensity control performance with conventional pressure control one. Active control experiment of local sound pressure is conducted by widely used filtered-x LMS adaptive Algorithm and active intensity control implementaion uses the derived filter d-x LMP algorithm. It is shown that the exterior sound fileds was much better observable by sensing of the active intensity than by just sound pressure. It is also demonstrated that the global control performance of external field by acoustic intensity is superior to the conventional sound pressure control performance.

  • PDF

2방향 전자밸브의 PWM 신호에 의한 압력제어 특성 (Pressure Control Characteristics of a 2-Way Solenoid Valve Driven by PWM Signal)

  • 정헌술;김형의
    • 대한기계학회논문집A
    • /
    • 제26권8호
    • /
    • pp.1565-1576
    • /
    • 2002
  • By way of driving a 2-way on/off solenoid hydraulic valve with a pulse width modulation (PWM) signal, control of the pressure in a certain volume is frequently used in various applications. However, the pressure built-up according to the duty ratio and carrier frequency of the PWM signal is not so well understood. In order to clarify the characteristics of 2-way valve hydraulic pressure control systems, in this paper two formula fur the mean and ripple of the load pressure were derived through theoretical analysis. And the accuracy of the derived formula were verified by comparison with the experimental test result. Generally 2-way valve systems are constructed as a bleed-off circuit, while 3-way valves are used as a control element in a meter-in circuit pressure control system. In a bleed-off circuit, the system supply pressure from a hydraulic power pack does not remain constant, but changes according to their external load. In turn, the relief valve in the hydraulic power pack reacts accordingly showing complicated dynamic behavior, which makes an analytical study difficult. In order to resolve the problem, simple but accurate empirical dynamic models fer a bleed-off system were used in the course of formula derivation. As the result, selection criteria for two major control parameters of the driving signal is established and the basic strategy to suppress the unnecessary pressure fluctuation can be provided for a hydraulic pressure control system using a 2-way on/off solenoid valve.

과량수혈이 혈역학에 미치는 영향 (Hemodynamic effects of induced overtransfusion of blood in dogs)

  • 기노석
    • Journal of Chest Surgery
    • /
    • 제17권3호
    • /
    • pp.418-423
    • /
    • 1984
  • Appreciation of the large volume deficits which may occur in surgical or trauma patients due to blood loss has led to vigorous transfusion techniques designed to overt hypovolemic shock and ischemic damage to vital organs which may develop in minutes during the hypovolemic state. In a significant proportion of patients treated with massive rapid blood or fluid transfusion, hypervolemia occurs and life threatening pulmonary edema may develop. Especially, hypervolemia may occur during transfusion for preventing development of the so-called low output syndrome following cardiac surgery. However, the most effective indicator which reveals the adequate level of transfusion is not settled yet. The present study was aimed to compare the effectiveness of the indicators suggested thus far and to determine the most sensitive one. Eight dogs were experimentally studied in terms of left atrial pressure, pulmonary arterial systolic pressure, central venous pressure, mean systemic arterial pressure and heart rate before and after induced hypervolemia with infusion of 600ml heparinized homologous blood. Immediately after induced overtransfusion of the blood, pulmonary arterial systolic pressure increased 75.0%, in omparison with the control before transfusion, left atrial pressure 58.8%, central venous pressure 44.6%, and mean systemic arterial pressure 10.1%, one hour after transfusion, pulmonary arterial systolic pressure 40.0%, left atrial pressure 21.2%, central venous pressure 14.5%, and mean systemic arterial pressure 3.2%, central venous pressure 14.5%, and mean systemic arterial pressure 3.2%, respectively. Heart rate showed no significant change throughout the experiment. These result suggested that the changes of the pulmonary arterial systolic pressure is the most sensitive indicator for detection of hypervolemia during blood transfusion.

  • PDF

An Automatic Control System of the Blood Pressure of Patients Under Surgical Operation

  • Furutani, Eiko;Araki, Mituhiko;Kan, Shugen;Aung, Tun;Onodera, Hisashi;Imamura, Masayuki;Shirakami, Gotaro;Maetani, Shunzo
    • International Journal of Control, Automation, and Systems
    • /
    • 제2권1호
    • /
    • pp.39-54
    • /
    • 2004
  • We developed an automatic blood pressure control system to maintain the blood pressure of patients at a substantially low level during a surgical operation. The developed system discharges two functions, continuous feedback control of the mean arterial pressure (MAP) by a state-predictive servo controller and risk control based on the inference by fuzzy-like logics and rules using measured data. Twenty-eight clinical applications were made beginning in November 1995, and the effects of the automatic blood pressure control on the operation time and on bleeding were assessed affirmatively by means of Wilcoxon testing. This paper essentially reports the engineering details of the control system.

Characteristics of Intraoral Air Pressure, Airflow in Relation to Phonatory Efficiency in Cleft Palate Speakers

  • Baek, Jin-A;Shin, Hyo-Keun
    • 대한음성언어의학회:학술대회논문집
    • /
    • 대한음성언어의학회 2003년도 제19회 학술대회
    • /
    • pp.147-147
    • /
    • 2003
  • Recent aerodynamic and acoustic studies of VPI(velopharyngeal insufficiency) are non-invasive and safety, therefore, many researchers have used it to diagnose the hyper/hyponasality and articulation disorders of cleft palate patients. The purpose of this study was to estimate mainly the oropharyngeal air pressure and over all air flow in cleft lip and palate patients. The pressure-collecting catheter was positioned in the oropharyngel cavity around tongue base. Twelve adult control group and three cleft lip & palate patients were participated to this experimentation. Aerophone II was used to measure peak air flow, mean air flow, phonatory airflow, phonatory efficiency and resistance. The results were as follows: 1) Airflow of cleft lip & palate patients group were higher than those of control group. Fricative sounds /s/ and /s'/ showed the statistic significance of mean airflow and volume data. 2) Intraoral air pressure of cleft lip & palate patients was lower than those of control group.

  • PDF

압전형 압력센서의 교정기법 자동화 (An automatic calibration technique for piezoelectric pressure sensors)

  • 최주호;유준
    • 제어로봇시스템학회논문지
    • /
    • 제3권4호
    • /
    • pp.357-362
    • /
    • 1997
  • This paper suggests an automatic calibration technique for piezoelectric low pressure transducer measuring a pressure blow 500psi. The present calibration system embedded with error correction algorithm generates it's best you don't cut parts of wards like so dynamic pressure and compensates offset voltage and pressure error. It is shown via experimental results that the instrumentation accuracy has been improved and mean time between calibrations has been shortened.

  • PDF