• Title/Summary/Keyword: Maximum removal

Search Result 1,138, Processing Time 0.032 seconds

Biosorption of Methylene Blue from Aqueous Solution using Dried Rhodotorula glutinis Biomass

  • Dae Haeng Cho;Jaesung Lee;Eui Yong Kim
    • Korean Chemical Engineering Research
    • /
    • v.61 no.2
    • /
    • pp.273-277
    • /
    • 2023
  • The biosorption of methylene blue (MB) from aqueous solution was investigated using dried Rhodotorula glutinis as the biosorbent. The effects of pH, initial dye concentration, biosorbent dosage, and kinetic studies were determined to obtain valuable information for biosorption. Results indicated that most of the adsorbed MB bound within 30 minutes of contact and the MB adsorption capacity increased from 21.1 to 101.8 mg/g with the initial MB concentration increased from 50 to 300 mg/L. Additionally, the MB adsorption capacity gradually increased from pH 4.0 to 9.0, reaching its peak at an initial pH of 9.0. As the biomass load was increased from 0.25 to 4.0 g/L, the MB removal efficiency increased from 14.1 to 84.5%. The Langmuir model provided the best fit throughout the concentration range, and the maximum adsorption capacity (qmax) and Langmuir constant (b) were determined to be 135.14 mg/g and 0.026 l/mg, respectively. Furthermore, the biosorbent process of R. glutinis was found to follow pseudo-second-order kinetics and the calculated qeq,cal value showed good agreement with the experimental qeq value. Overall, the biosorption of MB by R. glutinis can be characterized as a monolayer, single site type phenomenon, and the rate-limiting step was determined to be the chemical reaction between the adsorbent and the adsorbate.

Selective adsorption of ammonium ion via cobalt-based Prussian blue analogue (코발트 기반 프러시안블루 유사체를 이용한 수중 암모늄 이온의 선택적 흡착)

  • Tae Hwan Kim;Narges Dehbashi Nia;Yeo-Myeong Yun;Tae-Hyun Kim;Yuhoon Hwang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.38 no.2
    • /
    • pp.95-107
    • /
    • 2024
  • This study proposes the use of a cobalt-based Prussian blue analogue (Co-PBA; potassium cobalt hexacyanoferrate), as an adsorbent for the cost-effective recovery of aqueous ammonium ions. The characterization of Co-PBA involved various techniques, including Fourier-transform infrared spectroscopy, X-ray diffraction, scanning electron microscopy, nitrogen adsorption-desorption analysis, and zeta potential. The prepared Co-PBA reached an adsorption equilibrium for ammonium ions within approximately 480 min, which involved both surface adsorption and subsequent diffusion into the interior. The isotherm experiment revealed a maximum adsorption capacity of 37.29 mg/g, with the Langmuir model indicating a predominance of chemical monolayer adsorption. Furthermore, the material consistently demonstrated adsorption efficiency across a range of pH conditions. Notably, adsorption was observed even when competing cations were present. Co-PBA emerges as a readily synthesized adsorbent, underscoring its efficacy in ammonium removal and selectivity toward ammonium.

Research on Adsorption Capacity of Acetaminophen for Constructed Wetland Design (인공습지 설계를 위한 여재 아세트아미노펜 흡착능 실험)

  • Jin Hong;Yuhyeon Kim;Kyungik Gil
    • Journal of Wetlands Research
    • /
    • v.26 no.3
    • /
    • pp.272-278
    • /
    • 2024
  • Due to industrialization, a trace amount of residues of pharmaceuticals and personal hygiene products (PPCPs) flows into the ecosystem, polluting the ecosystem. In particular, it was intended to remove trace pollutants flowing into the effluent due to the increase in the amount of acetaminophen detected after COVID 19. To conduct this experiment, selected 6 media which are suitable for construcgted wetland and isothermal adsorption experiments. Langmuir equation and the Freundlich equation were used to calculate the maximum removal rate of acetaminophen. Among them, the Freundlich equation showed a higher result value of 0.9823. It was applied when forming constructed wetlands in urban areas to model the reduction rate of acetaminophen in wetlands.

Studies on the Removal of Phytate from Korean Rapeseed(Brassica napus, L) Proteins -Ⅰ. Effects of pH and Salts on Protein and Phytate Solubility of Defatted Rapeseed Flour- (한국산 평지 종실 단백질의 Phytate 제거에 관한 연구 -제1보. 평지 종실 단백질과 Phytate 의 용해도에 대한 pH와 염류의 영향-)

  • Huh, Chai-Ok;Yang, Cha-Bum
    • Applied Biological Chemistry
    • /
    • v.29 no.2
    • /
    • pp.212-218
    • /
    • 1986
  • Proteins in Korean rapeseeds, as in many other plantseeds, are usually bound to phytate molecules. These phytate-bound proteins are of little value as foodstuffs because of their poor solubility in digestive systems. Therefore it is necessary to remove phytates from proteins in order to convert these proteins io a useful foodstuff. In the work, an efficient procedure for removal of phytates from defatted Korean rapeseed was found. The influence of pH on the solubility of protein and phytate of rapeseed flour showed that the former was the lowest at pH 5.0 and began to increase as pH further raised. Meanwhile, the latter was the highest at pH 6.0, however, it was decreased abruptly at alkaline pH, especially to content of 1.3% at pH 11.5. The solubility cf protein was relatively high in NaCl aqueous solution at $pH\;6.0{\sim}8.0$, and did not male any noticeable difference depending on NaCl concentration. On the other hand, the solubility of phytate was high at pH of below 6.0 showing an abrupt decrease at pH of above 6.0. The solubility of protein in $CaCl_2$ aqueous solution was highest at $pH\;6.0{\sim}8.0$, however, there was no significant change at the whole range of tested pH of the solution. A maximum solubility of phytate was shown at $pH\;3.0{\sim}4.0$. And it was decreased abruptly at a higher pH of the above range and also decreased at a lower pH with higher $CaCl_2$ concentration. The solubility of phytate in $Na_2SO_3$ aqueous solution was highest at $pH\;5.0{\sim}8.0$. As the concentration goes up the maximum value of solubility was found to move to higher pHs. Depending on the concentration of $Na_2SO_3$, the decreasing pattern was changed in an alkaline solution. The solubility of phytate in the solution containing low concentration of $Ca^{2+}$ ion was low in all treatments at pH of above 7.0 and showed the maximum value at low pH as $Ca^{2+}$ ion concentration increases. The solubility of protein at pH 11.5 showed the highest value in $1mM\;Ca^{2+}$ ion solution.

  • PDF

Remediation for Gasoline Contaminated Soils with SVE (soil vapor extraction) Including a Post-treatment System of Extraction Gases (배출가스의 후처리 공정을 포함한 토양증기추출법을 이용한 가솔린 오염 토양 복원)

  • 이민희;강현민;이병헌;빈정인
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.2
    • /
    • pp.28-40
    • /
    • 2004
  • Box experiments were performed to evaluate the removal efficiency of SVE (soil vapor extraction) for gasoline in soil. An activated carbon sorption tower and a biofilter were operated as post-treatment processes to remove VOCs extracted from extraction wells of SVE. An acrylic resin box (65 cm${\times}$20 cm${\times}$30 cm) was used to make artificial soil layers and two injection wells and one extraction well were built for SVE process in the box. Gases from extraction wells flew into the activated carbon sorption tower or the biofilter. Gasoline concentrations of VOCs emitted from the extraction well were compared with those after post treatments. More than 92% of initial gasoline mass in soil were removed by SVE within few days, suggesting that SVE is very available to remove VOCs from contaminated soils. To treat VOCs from extraction wells of SVE, an activated carbon sorption tower and a biofilter were attached to SVE process and their gasoline removal efficiencies were measured. These post treatment systems lowered gasoline concentrations to below 1.0 ppm within few days. Average remediation efficiency was 98% of gasoline for the activated carbon sorption tower and 84.1% for the biofilter. The maximum removal capacity of a biofilter was 10.7 g/L/hr, which was ten times higher than general biofilter removal capacity. Results from the study suggest that the activated carbon sorption tower and the biofilter would be available for the post treatment process to remove VOCs generated from SVE process.

Performance Evaluation of Hydrocyclone Filter for Treatment of Micro Particles in Storm Runoff (Hydrocyclone Filter 장치를 이용한 강우유출수내 미세입자 제거특성 분석)

  • Lee, Jun-Ho;Bang, Ki-Woong;Hong, Sung-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.11
    • /
    • pp.1007-1018
    • /
    • 2009
  • Hydrocyclone is widely used in industry, because of its simplicity in design, high capacity, low maintenance and operational cost. The separation action of a hydrocyclone treating particulate slurry is a consequence of the swirling flow that produces a centrifugal force on the fluid and suspended particles. In spite of hydrocyclone have many advantage, the application for treatment of urban stormwater case study were rare. We conducted a laboratory scale study on treatable potential of micro particles using hydrocyclone filter (HCF) that was a combined modified hydrocyclone with perlite filter cartridge. Since it was not easy to use actual storm water in the scaled-down hydraulic model investigations, it was necessary to reproduce ranges of particles sizes with synthetic materials. The synthesized storm runoff was made with water and addition of particles; ion exchange resin, road sediment, commercial area manhole sediment, and silica gel particles. Experimental studies have been carried out about the particle separation performance of HCF-open system and HCF-closed system. The principal structural differences of these HCFs are underflow zone structure and vortex finder. HCF was made of acryl resin with 120 mm of diameter hydrocyclone and 250 mm of diameter filter chamber and overall height of 800 mm. To determine the removal efficiency for various influent concentrations of suspended solids (SS) and chemical oxygen demand (COD), tests were performed with different operational conditions. The operated maximum of surface loading rate was about 700 $m^3/m^2$/day for HCF-open system, and 1,200 $m^3/m^2$/day for HCF-closed system. It was found that particle removal efficiency for the HCF-closed system is better than the HCF-open system under same surface loading rate. Results showed that SS removal efficiency with the HCF-closed system improved by about 8~20% compared with HCF-open system. The average removal efficiency difference for HCF-closed system between measurement and CFD particle tracking simulation was about 4%.

Biodeodorization of Trimethylamine by Biofilter Packed with Waste Tire-Chips (폐타이어칩 충진형 바이오 필터에 의한 Trimethylamine 제거)

  • Park, Hun-Ju;Kim, Chang-Gyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.8
    • /
    • pp.789-797
    • /
    • 2008
  • This study was conducted to investigate removal characteristics of gaseous trimethylamine(TMA) through biofilter packed with waste tire-chips. The sludge in this experiment was collected from an activated sludge operated in a wastewater treatment facility treating malodorous pollutants. The nominal amount of collected sludge was inoculated through packing materials in the filter. The removal efficiencies for varying concentrations and SVs(Space velocity) were assessed based on TMA, COD$_{Cr}$, NO$_3{^-}$-N, NO$_2{^-}$-N, NH$_4{^+}$-N and EPS(Extracellular Polymeric Substances) in leachate, since biofilter had been steady-stately operated. The influent concentration of 10 ppm of TMA was removed to approximately 95% regardless of changing SV at 120 and 180 hr$^{-1}$, but it was lowered to 80 to 90% at SV 240 hr$^{-1}$. As influent concentration was gradually increased from 5 to 55 ppm, the removal efficiencies of TMA were initially high for 95% in the range of 5 to 10 ppm, but lowered to 80% for 10 to 30 ppm. As a part of kinetic study for TMA decomposition, V$_m$(maximum substrate removal rate) and $K_s$(substrate infinity coefficient) were 14.3 g$\cdot$m$^{-3}$$\cdot$h$^{-1}$ and 0.043 g$\cdot$m$^{-3}$, respectively while adapted period was shown in the range of 100 to 150 hr. Also, the EPS concentration was consistently observed from the leachate showing 100 to 200 ppm, which indicates that biofilm has been continuously formed and sustained throughout tire-chips packed reactor.

Effect of internal gap on retentivity in implant fixed prosthesis with lingual slot (설측 슬롯을 부여한 임플란트 고정성 보철물에서 내면 간격이 유지력에 미치는 영향)

  • Kim, Tae-Kyun;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.3
    • /
    • pp.206-211
    • /
    • 2018
  • Purpose: Recently, a method of forming a slot in the prosthesis lingual has been introduced to solve the occlusal and aesthetic disadvantages of screw-retained prosthesis in the manufacture of implant-fixed prosthesis and to ensure retrievability in cement retained prostheses. The purpose of this study is to investigate the effect of the internal gap on the removal of the prosthesis in the preparation of cement-retained implant prostheses with lingual slots. Materials and methods: Titanium abutment and internal gap of the zirconia prosthesis to be attached to the upper part were set to 30, 35, and $50{\mu}m$, respectively. Three for each type total 15 were produced for each type. The zirconia prosthesis formed a retrievable cement-type slot with a space of 1 mm at the location where the titanium abutment meets the shelf area. Autocatalytic resin cement was used for bonding of abutment and zirconia prosthesis, and the maximum removal stress value was measured in units of Ncm by using the customized equipment of the cemented specimen. The Kruskal-Wallis test was used to compare the three groups by statistical analysis (${\alpha}=.05$), modified by post hoc test the Mann-Whitney U-test and the Bonferroni correction method were used to compare the two methods (${\alpha}=.017$). Results: There was no statistically significant difference in removal stress between the $30{\mu}m$ group and the $35{\mu}m$ group in the internal gap (P = .032), and there was a significant difference between the $30{\mu}m$ group and the $50{\mu}m$ group, between the $35{\mu}m$ group and the $50{\mu}m$ group (P < .017). Conclusion: Thus, the internal gap of computer-aided design affected the retention between the zirconia prosthesis and the titanium abutment.

Long Term Operation of Microfiltration Membrane Pilot Plant for Drinking Water Treatment (정수처리를 위한 정밀여과막 모형플랜트의 장기운전 특성)

  • Kim, Chung H.;Lee, Byung G.;Lim, Jae L.;Kim, Seong S.;Lee, Kyeong H.;Chae, Seon H.
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.4
    • /
    • pp.493-501
    • /
    • 2007
  • The membrane pilot plant has being operated in the Hyeondo pumping station to find the optimal operation technique of Gong-Ju membrane water treatment plant (WTP) which is constructing in $250m^3/d$ scale. The pilot plant was consisted of two trains which can treat $30,000m^3/d$ per train. First train was operated for one year under the condition of flux $1m^3/m^2{\cdot}d$ while the effects of flux variation and addition of powdered activated carbon(PAC) were evaluated in second train. The turbidity of membrane product water of first train which is operated on Flux $1m^3/m^2{\cdot}d$ was always below 0.05 NTU regardless of raw water turbidity. And also, the trance-membrane pressure(TMP) was maintained at $0.3{\sim}0.5kgf/cm^2$ for about 9 months and increased rapidly to $1.8kgf/cm^2$ which is maximum operating TMP. However, TMP was rapidly increased to $1.8kgf/cm^2$ within 2 months as flux was increased from 1 to $2m^3/m^2{\cdot}d$, especially, within 10 days under high turbidity(30~50NTU). This reault means that if Gongju membrane WTP is operated in flux $1m^3/m^2{\cdot}d$, chemical cleaning period can be maintained over 6 months. Only 10% of dissolved organic carbon (DOC) was removed in membrane process while the removal efficiencies of manganese and iron were 60% and 77% respectively. However, because only solid manganese and iron were removed in membrane process, an additional process for treating soluble manganese is required if souble manganese is high in raw water. 70% of 70ng/L 2-MIB which is causing taste & odor was removed in powdered activated carbon (PAC) tank with 50mg/L PAC which is design concentration of Gongju WTP. In addition, TMP was reduced with addition of 50mg/L PAC regardless of flux. Because TMP was not influenced even if 100mg/L PAC was added, the high taste and odor problem can be controled by additional injection of PAC.

Characteristics of By-product Ochre from Acid Mine Drainage (AMD) Treatment and Its Potential Use (산성광산배수 (AMD) 처리 부산물 ochre의 특성과 활용)

  • Jeong, Jung-Hwan;Kim, Ho-Jin;Kim, Young-Nam;Nam, Kwang-Soo;Kim, Kye-Hoon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.43 no.3
    • /
    • pp.304-314
    • /
    • 2010
  • This study was carried out to find out potential use of ochre as an agent to reduce phosphorus content in water. Ochre is a by-product from treatment of acid mine drainage (AMD) which is composed mostly of $Fe_2O_3$, $Fe_2O_3{\cdot}H_2O$, $FeO{\cdot}OH$ and $Fe(OH)_3$. Three ochre samples (ochre-H, ochre-D and ochre-S) were collected from three treatment facilities in Gangwon province. Physico-chemical characteristics of three ochre samples including pH, electrical conductivity, total phosphorus, available phosphorus, particle size distribution were analyzed. Scanning electron microscopy (SEM) energy dispersive spectroscopy (EDS), X-ray diffraction (XRD) and X-ray fluorescence (XRF) analysis were also carried out. In addition, experiments for phosphorus removal from water was performed. Calcium content of ochre-H was higher than that of ochre-D and ochre-S, whereas iron content of ochre-H was lower than that of ochre-D and ochre-S. All the phosphorus in water up to maximum 191,411 mg $kg^{-1}$ per unit mass of ochre was removed with ochre-H. Ochre has immense potential as an agent to reduce phosphorus content in water.