• Title/Summary/Keyword: Maximum removal

Search Result 1,137, Processing Time 0.029 seconds

Studies on the Water Purification Using Water Parsley (미나리 (Oenanthe javanica(Blume) DC)를 이용한 수질정화에 관한 연구)

  • 권성환;나규환;류재근;김종택
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.3
    • /
    • pp.56-63
    • /
    • 1996
  • The results of the water purification studies using water parsley (Oenanthe javanica) were obtained as follows. The removal rate of nutrient salts increased with longer plant growth periods. The results of this study use the assumption, log(T+1) = $K(C_0-C)^A$, based on Prakish's Theory. The initial concentration was calculated from experimental data. A and K are closely related to the initial concentration. It is possible to model the concentration of residual salts, as time goes by, if concentration is constant. It was observed that water parsley neutralizes acid and alkali substances promptly. The maximum suitable neutralization period is 48 hours. But water parsley withered up in strong acid and alkali solutions within a week. The removal efficiency of Cd progresses in 2 steps, which are unrelated to the initial concentration of Cd. The first part of the curve shows the concentration rapid rate of Cd removal, followed by a levelling off. The removal rate of $NO_x-N$ in the sample water tank containing 0.5 ppm Cd was between 50~80% but the removal rate was less than 20% for the higher concentration. On the other hand, increased amounts of $PO_4-P$ in the sample water tank from the third day on suspected that $PO_4-P$ was desorbed from the water parsley. The accumulation efficiency of Cd in plant was increased in proportion to the initial concentration of Cd. The accumulation phenomenon was observed in the tanks more than 50~100 times.

  • PDF

Efficiency of Aluminum and Iron Electrodes for the Removal of Heavy Metals [(Ni (II), Pb (II), Cd (II)] by Electrocoagulation Method

  • Khosa, Muhammad Kaleem;Jamal, Muhammad Asghar;Hussain, Amira;Muneer, Majid;Zia, Khalid Mahmood;Hafeez, Samia
    • Journal of the Korean Chemical Society
    • /
    • v.57 no.3
    • /
    • pp.316-321
    • /
    • 2013
  • Electrocoagulation (EC) technique is applied for the treatment of wastewater containing heavy metals ions such as nickle (Ni), lead (Pb) and cadmium (Cd) by using sacrificial anodes corrode to release active coagulant flocs usually aluminium or iron cations into the solution. During electrolytic reactions hydrogen gas evolve at the cathode. All the experiments were carried out in Batch mode. The tank was filled with synthetic wastewater containing heavy metals and efficiency of electro-coagulation in combination with aluminum and iron electrodes were investigated for removal of such metals. Several parameters, such as contact time, pH, electro-coagulant concentration, and current density were optimized to achieve maximum removal efficiency (%). The concentrations of heavy metals were determined by using Atomic Absorption Spectroscopy (AAS). It is found that the electro-coagulation process has potential to be utilized for the cost-effective removal of heavy metals from wastewater specially using iron electrodes in terms of high removal efficiencies and operating cost.

The Coagulation Characteristics of Wastewater Using Poly-γ-glutamic Acid (Poly-γ-glutamic acid(PGA)를 이용한 폐수의 응집특성)

  • Kwon, Kwi-bock;Kim, Dong-ha;Kang, Seon-Hong;Sung, Moon-Hee;Park, Chung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.3
    • /
    • pp.357-362
    • /
    • 2005
  • Poly-${\gamma}$-glutamic acid (${\gamma}-PGA$), which is extracted from fermented soybeans, is a high molecular weight, adhesive, and negatively charged(anionic) polymer. Recently, ${\gamma}-PGA$ has gained attention due to its potential as polymer. The objectives of this study were to examine the applicability of ${\gamma}-PGA$ as a coagulant and/or a coagulant aid, to evaluate the efficiency of ${\gamma}-PGA$ for the removal of Organic and Ammonium substance in wastewater treatment. The effect of coagulation was evaluated for the removal of SS and organic matter using poly aluminum chloride(PACI) as well as newly developed ${\gamma}-PGA$. The maximum COD removal rate of 63% and the SS of 78% were occurred at the dosage of 50mg/L ${\gamma}-PGA$ only. The most effective removal for particulate and organic matter was occured when both PACI and ${\gamma}-PGA$ were applied at the rate of 20:1(10mg/L PACI and 0.5mg/L ${\gamma}-PGA$). When mixed with PACI, only small portion of ${\gamma}-PGA$ was enough to improve removal efficiencies of organic and particulate matter in wastewater. This result showed the positive potential of ${\gamma}-PGA$ as a new coagulant materials for wastewater treatment.

Preparation of Calcium Silicate Hydrate Extrudates and Their Phosphate Adsorption Studies

  • Rallapalli, Phani Brahma Somayajulu;Ha, Jeong Hyub
    • Applied Chemistry for Engineering
    • /
    • v.30 no.5
    • /
    • pp.562-568
    • /
    • 2019
  • Cylindrical shape extrudates of calcium silicate hydrate (CSH) were prepared using different percentages of polyvinyl alcohol (PVA) / sodium alginate (SA) mixtures as binders and an aqueous solution containing 6% $H_3BO_3$ and 3% $CaCl_2$ was used as a cross linking agent. As the quantity of alginate increases, the phosphate removal efficiency and capacity were decreased. Among four different extrudate samples, the sample prepared by 8% PVA + 2% SA showed the highest phosphate removal efficiency (59.59%) and capacity (29.97 mg/g) at an initial phosphate concentration of 100 ppm and 2.0 g/L adsorbent dosage. Effects of the adsorbent dosage, contact time and initial phosphate concentration on the sample were further studied. The removal efficiency and capacity obtained by a 4.0 g/L adsorbent dose at an initial phosphate concentration of 100 ppm in 3 h were 79.38% and 19.96 mg/g, respectively. The experimental data of kinetic and isotherm measurements followed the pseudo-second-order kinetic equation and Langmuir isotherm model, respectively. These results suggested that the phosphate removal was processed via a chemisorption and a monolayer coverage of phosphate anions was on the CSH surface. The maximum adsorption capacity ($q_{max}$) was calculated as 23.87 mg/g from Langmuir isotherm model.

Effective machine learning-based haze removal technique using haze-related features (안개관련 특징을 이용한 효과적인 머신러닝 기반 안개제거 기법)

  • Lee, Ju-Hee;Kang, Bong-Soon
    • Journal of IKEEE
    • /
    • v.25 no.1
    • /
    • pp.83-87
    • /
    • 2021
  • In harsh environments such as fog or fine dust, the cameras' detection ability for object recognition may significantly decrease. In order to accurately obtain important information even in bad weather, fog removal algorithms are necessarily required. Research has been conducted in various ways, such as computer vision/data-based fog removal technology. In those techniques, estimating the amount of fog through the input image's depth information is an important procedure. In this paper, a linear model is presented under the assumption that the image dark channel dictionary, saturation ∗ value, and sharpness characteristics are linearly related to depth information. The proposed method of haze removal through a linear model shows the superiority of algorithm performance in quantitative numerical evaluation.

Biofiltration of Gaseous Toluene Using Activated Carbon Containing Polyurethane Foam Media (활성탄 함유 폴리우레탄 담체를 사용하는 바이오필터에 의한 가스상 톨루엔의 처리)

  • Amarsanaa Altangerel;Shin Won-Sik;Choi Jeong-Hak;Choi Sang-June
    • Journal of Environmental Science International
    • /
    • v.15 no.6
    • /
    • pp.513-525
    • /
    • 2006
  • In recent decades, biofiltration has been widely accepted for the treatment of contaminated air stream containing low concentration of odorous compounds or volatile organic compounds (VOCs). In this study, conventional biofilters packed with flexible synthetic polyurethane (PU) foam carriers were operated to remove toluene from a contaminated air stream. PU foams containing various amounts of pulverized activated carbon (PAC) were synthesized for the biofilter media and tested for toluene removal. Four biofilter columns were operated for 60 days to remove gaseous toluene from a contaminated air stream. During the biofiltration experiment, inlet toluene concentration was in the range of 0-150 ppm and EBRT (i.e., empty bed residence time) was kept at 26-42 seconds. Pressure drop of the biofilter bed was less than 3 mm $H_2O/m$ filter bed. The maximum removal capacity of toluene in the biofilters packed with PU-PAC foam was in the order of column II (PAC=7.08%) > column III (PAC=8.97%) > column I (PAC=4.95%) > column IV (PAC=13.52%), while the complete removal capacity was in the order of column II > column I > column III > column IV. The better biofiltration performance in column II was attributed to higher porosity providing favorable conditions for microbial growth. The results of biodegradation kinetic analysis showed that PU-PAC foam with 7.08% of PAC content had higher maximum removal rate ($V_m$=14.99 g toluene/kg dry material/day) than the other PU-PAC foams. In overall, the performance of biofiltration might be affected by the structure and physicochemical properties of PU foam induced by PAC content.

Non-thermal Plasma Process for simultaneous removal of SO2/NOx from a Sintering Plant of Steel Works

  • Nam, Chang-Mo;Mok, Young-Sun;Kwon, Gi-Hong;Suh, You-Duck;Cho, Byeung-Rak
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.6 no.1
    • /
    • pp.81-86
    • /
    • 2003
  • For the simultaneous removal of $SO_2$/NOx from an iron-ore sintering plant, industrial plasma experiments have been conducted with a flue gas flow rate of $5,000Nm^3/hr$. The maximum 40kW power using the magnetic pulse compression (MPC) system generates a peak value of 100-150kV pulse voltage with its risetime of 200nsec and full width at half maximum (FWHM) of 500nsec, and with a frequency <300Hz. The plasma reactor module adopts a wire-plate structure with a gap of 200-400mm ID between plates. Initial concentrations of $SO_2$ and NOx were around 100-150ppm, respectively in the presence of 15% $O_2$ and <10% $H_2O$. Various reaction parameters such as specific energy ($Whr/Nm^3$), $NH_3$ injection with corona discharge, flow rate and injection of hydrocarbons were investigated for $SO_2$/NOx removal characteristics. About 90/65% of $SO_2$/NOx were simultaneously removed with a specific energy of $3.0Whr/Nm^3$ when both $NH_3$ and hydrocarbons were injected. Practical implications that the pilot-scale plasma results provide are further discussed.

  • PDF

Bioaccumulation of Chromium Ions by Immobilized Cells of a Filamentous Cyanobacterium, Anabaena variabilis

  • Khattar, Jasvir I.S.;Sarma, Tangirala-A.;Singh, Davinder-P.;Sharma, Anuradha
    • Journal of Microbiology and Biotechnology
    • /
    • v.12 no.1
    • /
    • pp.137-141
    • /
    • 2002
  • Anabaena variabilis ATCC 29413 grew in chromium (Cr) containing Chu-10 (basal) and nitrate-supplemented media, and the growth of the organism in $100{\mu}M$ chromium was found to be 50% of that in control medium. The growth in nitrate $({NO_3}^-)$ supplemented cultures was better as compared to cultures grown in basal medium. Free cells from basal and nitrate-supplemented media removed 5.2 and 7.4 nmol of chromium $mg^{-1}$protein in 8 h, respectively, from the medium containing $30{\mu}M$ chromium. The efficiency of chromium removal increased 7-fold in imidazole buffer (0.2 M, pH 7.0). A cell density equivalent to $100{\mu}g$ protein $ml^{-1}$ was found to be optimum for maximum Cr removal. Entrapment of cells in calcium-alginate beads did not affect the rate of Cr uptake by the cells. The efficiency of the laboratory-scale continuous flow bioreactor $(12.5{\times}2cm)$ loaded with alginate-immobilized cells (10 mg protein) and fed with $30{\mu}M$ chromium solution was compared at different flow rates. The efficiency of the bioreactor varied with flow rates. In terms of percent removal of Cr from influent, a flow rate of 0.1 ml $min^{-1}$ was found to be optimum for 6 h (54% Cr removal efficiency). Maximum amount of Cr (883 nmol) was removed by the cells in 3 h at a flow rate of 0.5 ml $min^{-1}$. The potential use of A. variabilis in removing Cr from industrial effluents is discussed.

Nitrite Accumulation Characteristics and Quantitative Analyses of Nitrifying and Denitrifying Bacteria in a Sequencing Batch Reactor (연속회분반응기의 아질산 축적 특성과 질산화 및 탈질 미생물의 정량적 분포 연구)

  • Kim, Dong-Jin;Kwon, Hyun-Jin;Yoon, Jung-Yee;Cha, Gi-Cheol
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.3
    • /
    • pp.383-390
    • /
    • 2008
  • Recently, the interests on economical nitrogen removal from wastewater are growing. As a method of the novel nitrogen removal technology, nitrogen removal via nitrite pathway by selective inhibition of free ammonia and free nitrous acid on nitrite oxidizing bacteria have been intensively studied. The inhibition effects of free ammonia and free nitrous acid are low when domestic wastewater is used, however, because of its relatively lower nitrogen concentration than the wastewater from industry and landfill, etc. In this study, a sequencing batch reactor (SBR) is proposed for nitrogen removal to investigate the effect of the low nitrogen concentration on nitrite accumulation. Nitrification efficiency reached almost 100% during the aerobic cycle and the maximum specific nitrification rate ($V_{max,nit}$) reached $17.8mg\;NH_4{^+}-N/g\;MLVSS{\bullet}h$. During the anoxic cycle, average denitrification efficiency reached 87% and the maximum specific denitrification rate ($V_{max,den}$) reached $9.8mg\;NO_3{^-}-N/g\;MLVSS{\bullet}h$. From the analysis the main reason of nitrite accumulation in the SBR was free nitrous acid rather than free ammonia. Nitrite accumulation increased with the decrease of organic content in the wastewater and the mechanism is not well understood yet. From the result of fluorescent in situ hybridization, the distribution of nitrite oxidizing bacteria was in equilibrium with ammonium oxidizing bacteria when nitrite accumulation did not occur.

DEVELOPMENT OF PREDICTABLE STABILITY TEST FOR ASSESSMENT OF OPTIMUM LOADING TIME IN DENTAL IMPLANT

  • Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Lee, Joo-Hee;Kwon, Ji-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.6
    • /
    • pp.628-633
    • /
    • 2008
  • STATEMENT OF PROBLEM: The application of a simple, clinically applicable noninvasive test to assess implant stability are considered highly desirable. So far there is still a controversy about correlation of various tests and implant stability. PURPOSE: In order to assess implant stability, the development of a new method is critical. It's possible to assess implant stability by calculating energy and angular momentum during implant installation. The purpose of this study is to evaluate the correlation of energy and implant stability. MATERIAL AND METHODS: Twenty three implants were installed in two different types of pig bone. Type I bone was retrieved from the distal aspect of the rib, with more cortical bone. Type II bone came from a more proximal region with less cortical components and a higher content of bone marrow and spongeous trabeculae. Insertion torque, removal torque, ISQ values and angular momentum and energy were measured. Pearson Correlation test was done to analyze the relation between RFA, maximum insertion torque, mean insertion torque, bone type, energy and removal torque. RESULTS: Type I bone showed higher removal torque than type II bone. Energy value was significantly correlated with maximum insertion torque and mean insertion torque. RFA values were related with insertion torques but the significance was lower than Energy value. CONCLUSION: Within the limitation of this study energy values were considered clinically predictable method to measure the implant stability.