• Title/Summary/Keyword: Maximum power coefficient

Search Result 333, Processing Time 0.036 seconds

Method for Adjusting Single Matching Network for High-Power Transfer Efficiency of Wireless Power Transfer System

  • Seo, Dong-Wook;Lee, Jae-Ho;Lee, Hyungsoo
    • ETRI Journal
    • /
    • v.38 no.5
    • /
    • pp.962-971
    • /
    • 2016
  • A wireless power transfer (WPT) system is generally designed with the optimum source and load impedance in order to achieve the maximum power transfer efficiency (PTE) at a specific coupling coefficient. Empirically or intuitively, however, it is well known that a high PTE can be attained by adjusting either the source or load impedance. In this paper, we estimate the maximum achievable PTE of WPT systems with the given load impedance, and propose the condition of source impedance for the maximum PTE. This condition can be reciprocally applied to the load impedance of a WPT system with the given source impedance. First, we review the transducer power gain of a two-port network as the PTE of the WPT system. Next, we derive two candidate conditions, the critical coupling and the optimum conditions, from the transducer power gain. Finally, we compare the two conditions carefully, and the results therefore indicate that the optimum condition is more suitable for a highly efficient WPT system with a given load impedance.

Evaluation of Curving Performance and Running Safety of New High-Power Electric Locomotive (신형 고출력 전기기관차의 곡선추종성 및 주행안전성 평가)

  • Ham, Young Sam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.6
    • /
    • pp.827-832
    • /
    • 2013
  • In this study, curve responsiveness was assessed based on the lateral force and running safety was evaluated based on the wheel unloading ratio and derailment coefficient, which is the ratio of the wheel load and the lateral force. The evaluation of the curving performance and running safety of the new high-power electric locomotive showed that the derailment coefficient appeared higher when the wheel-set was set to the front of the train instead of being placed backward, and the maximum value of the derailment coefficient was recorded as 0.572 on the Gyeongbu line. Furthermore, the lateral force increased in curved sections, and it appeared to be proportional to the curve radius. Meanwhile, a maximum axis lateral force of 77.6 kN was recorded on the Taebaek line, and the wheel unloading ratio was 47.6% on the Yeongdong line. Finally, the running safety at the maximum speed as well as the through-curve performance of the curve radius satisfied the required standards.

An Asymptotic Property of Multivariate Autoregressive Model with Multiple Unit Roots

  • Shin, Key-Il
    • Journal of the Korean Statistical Society
    • /
    • v.23 no.1
    • /
    • pp.167-178
    • /
    • 1994
  • To estimate coefficient matrix in autoregressive model, usually ordinary least squares estimator or unconditional maximum likelihood estimator is used. It is unknown that for univariate AR(p) model, unconditional maximum likelihood estimator gives better power property that ordinary least squares estimator in testing for unit root with mean estimated. When autoregressive model contains multiple unit roots and unconditional likelihood function is used to estimate coefficient matrix, the seperation of nonstationary part and stationary part of the eigen-values in the estimated coefficient matrix in the limit is developed. This asymptotic property may give an idea to test for multiple unit roots.

  • PDF

Effect of Blockage Ratio on Wind Tunnel Testing of Small Vertical-Axis Wind Turbines (소형 수직축 풍력발전기 풍동실험시 폐쇄율의 영향)

  • Jeong, Houi-Gab;Lee, Seung-Ho;Kwon, Soon-Duck
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.98-106
    • /
    • 2014
  • The effect of blockage ratio on wind tunnel testing of small vertical-axis wind turbine has been investigated in this study. Height and rotor diameter of the three blades Darrieus vertical axis wind turbine used in present test were 0.4m and 0.35m respectively. We measured the wind speeds and power coefficient at three different wind tunnels where blockage ratio were 3.5%, 13.4% and 24.7% respectively. The test results show that the measured powers have been strongly influenced by blockage ratio, generally increased as the blockage ratio increases. The maximum power at higher blockage ratio has been obtained at relatively high tip speed ratio compared with that at low blockage ratio. The measured power coefficients under high blockage ratio can be improved from proper correction using the simple correction equation based on blockage factor. In present study, the correction error for power coefficient can be less than 5%, however correction effectiveness reveals relatively poor at high blockage ratio and low wind speed.

Optimization of a Savonius hydrokinetic turbine for performance improvement: A comprehensive analysis of immersion depth and rotation direction

  • Mafira Ayu Ramdhani;Il Hyoung Cho
    • Ocean Systems Engineering
    • /
    • v.14 no.2
    • /
    • pp.141-156
    • /
    • 2024
  • The turbine system converts the kinetic energy of water flow to electricity by rotating the rotor in a restricted waterway between the seabed and free surface. A turbine system's immersion depth and rotation direction are significantly critical in the turbine's performance along with the shape of the rotor. This study has investigated the hydrodynamic performance of the Savonius hydrokinetic turbine (SHT) according to the immersion depth and rotation direction using computational fluid dynamics (CFD) simulations. The instantaneous torque, torque coefficient, and power coefficients are calculated for the immersion ratios Z/D ranging [0.25, 3.0] and both clockwise (CW) and counterclockwise (CCW) rotations. A flow visualization around the rotor is shown to clarify the correlation between the turbine's performance and the flow field. The CFD simulations show that the CCW rotation produces a higher power at shallow immersion, while the CW rotation performs better at deeper immersion. The immersion ratio should be greater than the minimum of Z/D=1.0 to obtain the maximum power production regardless of the rotation direction.

Analysis of the flow distribution and mixing characteristics in the reactor pressure vessel

  • Tong, L.L.;Hou, L.Q.;Cao, X.W.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.1
    • /
    • pp.93-102
    • /
    • 2021
  • The analysis of the fluid flow characteristics in reactor pressure vessel is an important part of the hydraulic design of nuclear power plant, which is related to the structure design of reactor internals, the flow distribution at core inlet and the safety of nuclear power plant. The flow distribution and mixing characteristics in the pressurized reactor vessel for the 1000MWe advanced pressurized water reactor is analyzed by using Computational Fluid Dynamics (CFD) method in this study. The geometry model of the full-scaled reactor vessel is built, which includes the cold and hot legs, downcomer, lower plenum, core, upper plenum, top plenum, and is verified with some parameters in DCD. Under normal condition, it is found that the flow skirt, core plate holes and outlet pipe cause pressure loss. The maximum and minimum flow coefficient is 1.028 and 0.961 respectively, and the standard deviation is 0.019. Compared with other reactor type, it shows relatively uniform of the flow distribution at the core inlet. The coolant mixing coefficient is investigated with adding additional variables, showing that mass transfer of coolant occurs near the interface. The coolant mainly distributes in the 90° area of the corresponding core inlet, and mixes at the interface with the coolant from the adjacent cold leg. 0.1% of corresponding coolant is still distributed at the inlet of the outer-ring components, indicating wide range of mixing coefficient distribution.

Analysis of Burnable Poison Effect on Power Distribution using Power Sensitivity Coefficient Concept (출력민감도 계수개념을 이용한 가연성 독붕봉이 출력분포에 미치는 영 향의 분석)

  • Yi, Yu-Han;Oh, Soo-Youl;Seong, Seung-Hwan;Lee, Un-Chul
    • Nuclear Engineering and Technology
    • /
    • v.20 no.1
    • /
    • pp.19-26
    • /
    • 1988
  • The low leakage leading pattern has features as the placement of some fresh fuel assemblies in the core interior to reduce the neutron fluence on the pressure vessel and to enhance the neutron economics. But as fresh fuel assemblies are loaded in the core interior, the local power tends to exceed safety limit due to the high reactivity of the fresh assemblies. Therefore, a large number of burnable poisons must be utilized in a low leakage scheme to suppress the high assembly power as well as the excess reactivity. In this study the effects of burnable poisons are treated as a perturbation on the power distribution, and the 'Power Sensitivity Coefficient' concept is adopted. An application study is performed for cycle 1 of the Korea Nuclear Unit-7 (KNU-7) to justify the usefulness of the reverse depletion method coupled with the above concept. To obtain the optimal burnable poision distribution at the given burnup step, the linear programming technique is adopted. The result shows maximum 4.5% error in the amount of burnable poisons between the calculated and the reference values. It is concluded that the design methodology which consists of the reverse depletion, the power sensitivity coefficient concept, and the linear programming technique can be used to find the optimal turnable poison distribution.

  • PDF

Control Strategy and Stability Analysis of Virtual Synchronous Generators Combined with Photovoltaic Dynamic Characteristics

  • Ding, Xiying;Lan, Tianxiang;Dong, Henan
    • Journal of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.1270-1277
    • /
    • 2019
  • A problem with virtual synchronous generator (VSG) systems is that they are difficult to operate stably with photovoltaic (PV) power as the DC side. With this problem in mind, a PV-VSG control strategy considering the dynamic characteristics of the DC side is proposed after an in-depth analysis of the dynamic characteristics of photovoltaic power with a parallel energy-storage capacitor. The proposed PV-VSG automatically introduces DC side voltage control for the VSG when the PV enters into an unstable working interval, which avoids the phenomenon where an inverter fails to work due to a DC voltage sag. The stability of the original VSG and the proposed PV-VSG were compared by a root locus analysis. It is found that the stability of the PV-VSG is more sensitive to the inertia coefficient J than the VSG, and that a serious power oscillation may occur. According to this, a new rotor model is designed to make the inertial coefficient automatically change to adapt to the operating state. Experimental results show that the PV-VSG control strategy can achieve stable operation and maximum power output when the PV output power is insufficient.

A study on characteristics analysis of 5kW Small-scaled Inductive Power Transfer Module for Railway Vehicles (철도차량용 5kW급 유도급전 축소 모듈의 특성 분석 연구)

  • Park, Chan-Bae;Lee, Hyung-Woo;Lee, Byung-Song;Jung, Ho-Sung;Kim, Ki-Byung;Kim, Chul-Sub
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1675-1680
    • /
    • 2011
  • Inductive power transfer module(IPTM) is a contact-less power supply device and its application range has been extended to the large capacity devices such as electric vehicles, industrial mover and railway system as well as small capacity devices such as electric toothbrush charger, celluar phone charger, and so on. For railway application, the IPTM will transfer energy while train stops at a station for around 30[sec]. Therefore, equivalent circuit parameters and coupling coefficient of IPTM are an important design factor for the high energy transfer efficiency. This paper investigates the properties of equivalent circuit parameters and coupling coefficient of U-U type IPTM and U-I type IPTM using an analytical method and experimental method. Considering the coupling coefficient of the U-U type is larger than U-I type's, the U-U type is suitable for an application which need maximum power transfer and high efficiency.

  • PDF

Correlation Analysis between Distributed Generation Maximum Hosting Capacity of Target and Non-Target Bus (목표 및 비 목표 모선의 분산전원 최대 Hosting capacity 간의 상관관계 분석)

  • Kim, Ji-Soo;Oh, Yun-Sik;Cho, Gyu-Jung;Kim, Min-Sung;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.9
    • /
    • pp.1317-1324
    • /
    • 2017
  • These days, a penetration of distributed generation(DG) has increased in power system. Due to increased penetration of DG, a whole system is forced to install the maximum hosting capacity of DG. Therefore analysis between the maximum hosting capacity of DG at the target bus and the whole system is important. If we know the maximum hosting capacity, it will be able to satisfy the demand of system planner and customer. In this paper, we use a genetic algorithm to calculate the hosting capacity with optimization program using Design Analysis Kit for Optimization and Terascale Applications(DAKOTA). To consider a real system, we establish constraints and use IEEE 34 node test system. In addition, through the correlation coefficient between the target bus and the other buses, when capacity of DG at the target bus increases, we analyze which capacity of DG at the other buses will be decreased.