벨마우스 깊이가 다른 소형축류홴의 공력특성에 대한 실험적 연구 (Experimental Study on the Aerodynamic Performance Characteristics of a Small-Size Axial Fan with the Different Depths of Bellmouth)

  • 김장권;오석형
    • 동력기계공학회지
    • /
    • 제17권6호
    • /
    • pp.73-78
    • /
    • 2013
  • A Small-size axial fan(SSAF) has widely been utilized to circulate a cooling air in a refrigerator, etc. Generally, the aerodynamic performance of SSAF is strongly dependent upon the depth between SSAF and bellmouth, and it includes axial, partially stalled, mostly stalled and radial flow regions according to the flow coefficient. In this study, four kinds of bellmouth depths were considered to analyze the aerodynamic performance of SSAF. As a bellmouth depth increases, a maximum flowrate decreases, but a maximum static pressure increases. Also, stall region includes an inflection point in all aerodynamic performance curves. Finally, a static pressure efficiency shows the maximum value of 37%.

국산 트랙터의 성능 변화 (Performance Trend of Korean-made Agricultural Tractors)

  • 김경욱
    • Journal of Biosystems Engineering
    • /
    • 제30권6호통권113호
    • /
    • pp.321-326
    • /
    • 2005
  • Tractor performance was analyzed using the data from 226 Korean-made and 107 imported tractors tested at the National Institute of Agricultural Engineering for the 25-year period from 1980 through 2004. The performance analysis included the specific volumetric fuel consumption (svfc), power per unit weight and traction coefficient evaluated from the viewpoint of PTO power level. No significant performance improvement has been made for the Korean-made tractors over the last 25 years. The average svfc for the maximum PTO power has increased by only $2.1\%$ from 1980 to 2004, resulting in 2.86 kW${\cdot}$h/L in 2004. The average maximum PTO and drawbar power per unit weight of ballasted tractors were 1.38 and 1.19 kW/kN in 2000-2004, indicating $14.0\%$ and $5.9\%$ decreases respectively from 1980 to 2004. The traction coefficient has increased by $23.1\%$ over the 25 years, resulting in 0.68 in the 2000-2004 period. Poor performance improvement was also observed from the imported tractors. In the 2000-2004 period, average svfc for the maximum PTO power, PTO power per unit ballasted weight, drawbar power per unit ballasted weight and traction coefficient of the imported tractors were respectively 3.0 kW${\cdot}$h/L, 1.34 kW/kN, 1.13 kW/kN and 0.68. PTO and drawbar power per unit weight were lower in imported tractors than the Korean-made tractors. Comparing the test results with those of tractors less than 37 kW tested at the Nebraska Tractor Test Laboratory from 1981 to 2002, the Korean-made tractors have exhibited better performance in terms of power per unit weight. However, poor performance in the svfc and traction coefficient was observed. The average svfc and traction coefficient of the Korean-made tractors were respectively $86.4\%$ and $83.7\%$ of the tractors tested at the NTTL over the same period.

아크형 날개를 이용한 항력식 수직축 소형 풍력 터빈 설계 (Design of Drag-type Vertical Axis Miniature Wind Turbine Using Arc Shaped Blade)

  • 김동건;김문경;차득근;윤순현
    • 한국유체기계학회 논문집
    • /
    • 제9권2호
    • /
    • pp.7-12
    • /
    • 2006
  • This study is to develop a system of electric power generation utilizing the wind resources available in the domestic wind environment. We tested drag-type vortical wind turbine models, which have two different types of blades: a flat plate and circular arc shape. Through a performance test, conditions of maximum rotational speed were found by measuring the rpm of wind turbine. The rotational speed was measured by a tachometer in a wind tunnel and the tunnel wind speed was by using a pilot-static tube and a micro manometer. The performance test for a prototype was accomplished by calculating power, power coefficient, torque coefficient from the measurement of torque and rpm by a dynamometer controller From the measurements for miniature turbine models with two different blades, the circular arc shape was found to Produce a maximum rotational speed for the same wind velocity condition. Based on this result, the prototype with the circular arc blade was made and tested. We found that it produces 500W at the wind velocity of 10.8 m/s and the power coefficient was 20%.

500kW급 수평축 조류발전기의 수력 최적 설계 (Hydrodynamically Optimal Blade Design for 500kW Class Horizontal Axis Tidal Current Turbine)

  • 유기완
    • 한국태양에너지학회 논문집
    • /
    • 제29권5호
    • /
    • pp.73-80
    • /
    • 2009
  • A tidal current turbine is designed and analyzed numerically by using blade element momentum theory. The rated power has a limitation because the diameter of the tidal current turbine cannot exceed the depth of sea water. This study investigates a horizontal axis tidal-current turbine with a rated power of 500 kW. NACA-6 series laminar foil shape is used for basic airfoil along the blade span. The distributions of chord length and twist angle along the blade span are obtained from the hydrodynamic optimization procedure. Prandtl's tip loss correction and angle of attack correction considering the three-dimensional effect are applied for this study. The power coefficient curve shows maximum peak at the rated tip speed ratio of 6.0, and the maximum torque coefficient is developed at the tip speed ratio of 4. The drag coefficient reaches about 0.85 at the design tip speed ratio.

SmCoO3 페롭스카이트 계 열전소재에서 Fe2O3 첨가제가 출력인자에 미치는 영향 (An Effect of Fe2O3 Additive on a Seebeck Coefficient and a Power Factor for SmCoO3 Perovskite System)

  • 정광희;최순목;서원선;박형호
    • 한국세라믹학회지
    • /
    • 제47권5호
    • /
    • pp.457-460
    • /
    • 2010
  • $SmCoO_3$ system was investigated for their application to themoelectric materials. All specimens showed p-type semiconducting behavior and their electrical conductivity ($\sigma$), Seebeck coefficient (S) and power factor were measured at high temperature. And the effect of dopant ions on their thermoelectrical properties were also investigated. $Fe^{3+}$ ion doped into $Co^{3+}$ site enhanced the Seebeck coefficient and decreased the electrical conductivity simultaneously. The maximum Seebeck coefficient value for 60% doping case reached to 780 ${\mu}V$/K at $240^{\circ}C$. However $Fe^{3+}$ doped system cause an negative effect on power factor value. In case of the pure phase, the maximum Seebeck coefficient value reached to 290 ${\mu}V$/K at $240^{\circ}C$ and the maximum electrical conductivity was obtained 748 1/(ohm$\times$cm) at $960^{\circ}C$. As a result, the maximum power factor was obtained $1.49\times10^{-4}$ W/$mK^2$ at $550^{\circ}C$.

계통연계 풍력발전 시스템의 최대출력 제어를 위한 PI 제어기의 성능 분석 (Performance of PI Controller for Maximum Power Extraction of a Grid-Connected Wind Energy Conversion System)

  • 노경수;류행수
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권8호
    • /
    • pp.391-397
    • /
    • 2002
  • This paper presents a modeling and simulation of a PI controller for maximum power extraction of a grid-connected wind energy conversion system with a link of a rectifier and an inverter. It discusses the maximum power control algorithm fnr a wind turbine and proposes, in a graphical form, the relationships of wind turbine output, rotor speed, power coefficient, tip-speed ratio with wind speed when the wind turbine is operated under the maximum power control. The control objective is to always extract maximum power from wind and transfer the power to the utility by controlling both the Pitch angle of the wind turbine blades and the inverter firing angle. Pitch control method is mechanically complicated, but the control performance is better than that of the stall regulation method. The simulation results performed on MATLAB will show the variation of generator's rotor angle and rotor speed, pitch angle, and generator output.

Performance and Flow Condition of Cross-Flow Wind Turbine with a Symmetrical Casing Having Side Boards

  • Shigemitsu, Toru;Fukutomi, Junichiro;Toyohara, Masaaki
    • International Journal of Fluid Machinery and Systems
    • /
    • 제9권2호
    • /
    • pp.169-174
    • /
    • 2016
  • A cross-flow wind turbine has a high torque coefficient at a low tip speed ratio. Therefore, it is a good candidate for use as a self-starting turbine. Furthermore, it has low noise and excellent stability; therefore, it has attracted attention from the viewpoint of applications as a small wind turbine for an urban district. However, its maximum power coefficient is extremely low (10 %) as compared to that of other small wind turbines. In order to improve the performance and flow condition of the cross-flow rotor, the symmetrical casing with a nozzle and a diffuser are proposed and the experimental research with the symmetrical casing is conducted. The maximum power coefficient is obtained as $C_{pmax}=0.17$ in the case with the casing and $C_{pmax}=0.098$ in the case without the casing. In the present study, the power characteristics of the cross-flow rotor and those of the symmetrical casing with the nozzle and diffuser are investigated. Then, the performance and internal flow patterns of the cross-flow wind turbine with the symmetrical casings are clarified. After that, the effect of the side boards set on the symmetrical casing is discussed on the basis of the analysis results.

Simulation for Pitch Angle Control Strategies of a Grid-Connected Wind Turbine System on MATLAB/Simulink

  • 노경수;최준호
    • 조명전기설비학회논문지
    • /
    • 제21권1호
    • /
    • pp.91-97
    • /
    • 2007
  • This paper presents a pitch angle controller of a grid-connected wind turbine system for extracting maximum power from wind and implements a modeling and simulation of the wind turbine system on MATLAB/Simulink. It discusses the maximum power control algorithm for the wind turbine and presents, in a graphical form, the relationship of wind turbine output, rotor speed, and power coefficient with wind speed when the wind turbine is operated under the maximum power control algorithm. The objective of pitch angle control is to extract maximum power from wind and is achieved by regulating the blade pitch angle during above-rated wind speeds in order to bypass excessive energy in the wind. Case studies demonstrate that the pitch angle control is carried out to achieve maximum power extraction during above-rated wind speeds and effectiveness of the proposed controller would be satisfactory.

수직축 항력식 풍력터빈의 구조설계 및 실험평가 (Structure Design and Experimental Appraisal of the Drag Force Type Vertical Axis Wind Turbine)

  • 김동건;금종윤;윤순현
    • 대한기계학회논문집B
    • /
    • 제30권3호
    • /
    • pp.278-286
    • /
    • 2006
  • Experiments were conducted to estimate the performance of drag force type vertical axis wind turbine with an opening-shutting rotor. It was operated by the difference in drag force generated on both sides of the blades. The rotational speed was measured by a tachometer in a wind tunnel and the tunnel wind speed was measured by using a pilot-static tube and a micro manometer. The performance test for a prototype was accomplished by calculating power, power coefficient, torque coefficient from the measurement of torque and rpm by a dynamometer controller. Various design parameters, such as the number of blades(B), blade aspect ratio(W/R), angle of blades$(\alpha)$ and drag coefficient acting on a blade, were considered for optimal conditions. At the experiment of miniature model, maximum efficiency was found at N=15, $\alpha=60^{\circ}$ and W/R=0.32. The measured test variables were power, torque, rotational speed, and wind speeds. The data presented are in the form of power and torque coefficients as a function of tip-speed ratio V/U. Maximum power was found in case of $\Omega=0.33$, when the power and torque coefficient were 0.14 and 0.37 respectively. Comparing model test with prototype test, similarity law by advance ratio for vertical axis wind turbine was confirmed.

가변 풍력발전 시스템의 최대출력 제어를 위한 Fuzzy 제어기 설계 (A Fuzzy Logic Controller Design for Maximum Power Extraction of Variable Speed Wind Energy Conversion System)

  • 김재곤;허욱열;김병륜
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권11호
    • /
    • pp.753-759
    • /
    • 2004
  • This paper presents a modeling and simulation of a fuzzy controller for maximum power extraction of a grid-connected wind energy conversion system with a link of a rectifier and an inverter. It discusses the maximum power control algorithm for a wind turbine and proposes, in a graphical form, the relationships of wind turbine output, rotor speed, power coefficient, tip-speed ratio with wind speed when the wind turbine is operated under the maximum power control. The control objective is to always extract maximum power from wind and transfer the power to the utility by controlling both the pitch angle of the wind turbine blades and the inverter firing angle. Pitch control method is mechanically complicated, but the control performance is better than that of the stall regulation method. The simulation results performed on MATLAB will show the variation of generator's rotor angle and rotor speed, pitch angle, and generator output.