• 제목/요약/키워드: Maximum flame length

검색결과 35건 처리시간 0.025초

화염 불안정성에 따른 개선된 이미지 처리 기법을 활용한 디젤-바이오디젤 혼합 연료 액적의 연소 특성 (The Combustion Characteristics of Diesel-Biodiesel Blended Fuel Droplets Using the Modified Image Processing Method According to Flame Instability)

  • 최주환;임영찬;서현규
    • 한국분무공학회지
    • /
    • 제26권3호
    • /
    • pp.142-148
    • /
    • 2021
  • The objective of this study is to analyze the basic flame behavior characteristics using the single fuel droplet combustion of diesel, palm-based biodiesel, and canola-based biodiesel. The results were compared and analyzed through the post processed image, which was applied the threshold level for removing noise in the raw image. The raw image was taken by a high-speed camera during the entire combustion process. At the same time, the maximum flame length, which was measured by the application code of the MATLAB program, the ignition delay, and the combustion period were compared and analyzed.

고온 예열 공기에 의한 난류 비예혼합 화염의 연소 특성 (Combustion Characteristics of a Turbulent Non-premixed Flame Using High Preheated Air)

  • 곽지현;전충환;장영준
    • 대한기계학회논문집B
    • /
    • 제27권5호
    • /
    • pp.561-568
    • /
    • 2003
  • An experiment using high preheated air in a turbulent non-premixed flame was performed to investigate the effects of high preheated air on the combustion characteristics. Combustion using high preheated and diluted air with flue gas is a new technology which enables NO emission to be reduced. In this study, Na was used as diluent and propane as fuel. Combustion characteristics, especially the distributions of the flame temperature, NO concentration and OH radical intensity were examined under the condition of 300 K, 600 K, 1000 K in terms of the combustion air temperature, and also under the condition of the dilution level from 21% to 13% in terms of oxygen concentration. As the preheated air temperature increased, it appeared that the flame length became shorter, maximum flame temperature increased, the reaction region moved to upstream, and NO concentration increased, but the flame temperature's fluctuation was reduced. In opposite, it was shown with decrement of oxygen concentration at the maximum temperature that both maximum value and the gradient of the flame temperature decreased, and NO emission also decreased considerably, but its fluctuation became larger, being inclined to be unstable.

화염을 이용한 잡초방제 연구 (Weed Control by Flame)

  • 姜和錫;文學洙
    • Journal of Biosystems Engineering
    • /
    • 제26권4호
    • /
    • pp.331-336
    • /
    • 2001
  • This study was to develop a kerosene flame weeder. An air compressor was driven though the PTO of a tractor to provide necessary air for fuel combustion and proper pressure to supply fuel from fuel tank to the nozzle. It was found that the flame was extinguished very easily by wind and vibration of the tractor. This trouble could be solved by attaching a burner cap, which is a modified venturi tube, at the end of the nozzle. The constructed flame weeder was tested for the weeding capability in the prepared field. Weed extinction rate and weight decrease rate were analysed. Measured maximum flame temperature was 1,121$\^{C}$ when the fuel consumption was 13.41 kg/h and fuel supply pressure was 88.2 kPa. The maximum temperature occurred at 20cm from the front end the burner, and it decreased to 46$\^{C}$ as the distance increased to 110cm. The flame length of up to 70cm, where the flame temperature was higher than 372$\^{C}$, would be used for weeding purpose. Weed extinction rate and weight decreasing rate increased as the fuel consumption increased. The flame weeder was evaluated to be a practical weeder through improvement as the weed extinction rate and weight decrease rate were analysed to be 75% and 85%, respectively when the fuel consumption was 116.87kg/ha.

  • PDF

스월유동장의 화염전파에 미치는 난류특성의 영향에 관한 연구 (A study on the influence of turbulence characteristics on flame propagation in swirl flow field)

  • 이상준;이종태;이성열
    • 대한기계학회논문집B
    • /
    • 제20권10호
    • /
    • pp.3282-3292
    • /
    • 1996
  • Flow velocity was measured using a hot wire anemometer. Turbulence intensity was in proportion to mean flow velocity regardless of swirl velocity. And integral length scale has proportional relation with swirl velocity regardless of measurement position. Flame speed calculated by radius of visualized flame was increased and then decreased according to lapse of time from spark. Maximum flame speed was increased according to increase of turbulence intensity. Burning speed and flame transport effect increased with increase of swirl velocity, but ratio of burning speed to flame speed decreased with increased of swirl velocity. Mass fraction burned versus volume fraction burned was increased in proportion to the increase of turbulence intensity, caused by increase of combustion promotion effect according to increase of turbulence intensity and scale.

합판 종류에 따른 기능성 오일스테인의 성능 평가 (Performance Evaluation of Functional Oil Stain by Plywood Type)

  • 이주원;이창우;황우준;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.35-36
    • /
    • 2022
  • In order to supplement the flame-retardant performance of oil stain, which can prevent wooden buildings from contamination, (NH4)2HPO4, a phosphorus flame-retardant, was added to oil stain and applied for each type of plywood, and an experiment was conducted. The addition rate was set to 0-60%, but white powder appeared on the surface of plywood from 40% and thus it was impossible to experiment, so the maximum addition rate was selected as 30%. As a result of the experiment, acacia plywood had the best performance. As the rate of addition of the flame retardant increased, the remaining time and carbonization length of all plywood decreased, but the carbonization length of the MDF plywood was not met with the standards.

  • PDF

케이블 화재의 화염전파 해석을 위한 FDS 모델의 격자민감도 평가 (Assessment of Grid Sensitivity in the FDS Field Model to Simulate the Flame Propagation of an Electric Cable Fire)

  • 김성찬;이성혁
    • 한국안전학회지
    • /
    • 제23권4호
    • /
    • pp.30-35
    • /
    • 2008
  • The present study has been conducted to examine the effect of grid resolution on the predicted results for electric cable fire using pyrolysis model in FDS(Fire Dynamics Simulator, version 5). The grid independent test for different grid resolutions has been performed for a PE coating cable and the grid resolution is defined by the non-dimensional characteristic length of fire and mean grid size. The calculated maximum heat release rate and mean flame spread rate were almost constant for higher grid resolution of 20${\sim}$25 and the computing time for the grid resolution takes approximately 20hours to solve flame propagation with pyrolysis model. The geometrical simplification of a electric cable dose not greatly affect on the maximum heat release rate and flame spread rate and the rectangular approximation of cable shape gives acceptable result comparing with the round cable with stepwise grid.

영역조건평균에 기초한 난류연소속도의 직접수치해법검증 (Validation of an asymptotic zone conditional expression for turbulent burning velocity against DNS database)

  • 김수엽;허강열
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2004년도 제29회 KOSCI SYMPOSIUM 논문집
    • /
    • pp.62-69
    • /
    • 2004
  • Zone conditional formulations for the Reynolds average reaction progress variable are used to derive an asymptotic expression for turbulent burning velocity. New DNS runs are performed for validation in a statistically one dimensional steady state configuration. Parametric study is performed with respect to turbulent intensity, integral length scale, density ratio and laminar flame speed. Results show good agreement between DNS results and the asymptotic expression in terms of measured maximum flame surface density and estimated turbulent diffusivity in unburned gas.

  • PDF

영역조건평균에 기초한 난류연소속도의 직접수치해법검증 (Validation of an asymptotic zone conditional expression for turbulent burning velocity against DNS database)

  • 김수엽;허강열
    • 한국연소학회지
    • /
    • 제9권4호
    • /
    • pp.1-8
    • /
    • 2004
  • Zone conditional formulation for the Reynolds average reaction progress variable is used to derive an asymptotic expression for turbulent burning velocity. New DNS runs are performed for validation in a statistically one dimensional steady state configuration. Parametric study is performed with respect to turbulent intensity, integral length scale, density ratio and laminar flame speed. Results show good agreement between DNS results and the asymptotic expression in terms of measured maximum flame surface density and estimated turbulent diffusivity in unburned gas.

  • PDF

연소합성된 $TiO_2$ 나노입자의 입자특성에 대한 화염온도 변화의 영향 (Effect of Flame Temperature on the Characteristics of the Combustion Synthesized $TiO_2$ Nanoparticles)

  • 이교우
    • 한국연소학회지
    • /
    • 제11권1호
    • /
    • pp.11-18
    • /
    • 2006
  • In this work, $TiO_2$ nanoparticles were synthesized using $N_2-diluted$ and Oxygen-enriched coflow hydrogen diffusion flames. The effect of flame temperature on the characteristics of the formed $TiO_2$ nanoparticles was investigated. The measured maximum centerline temperature of the flame ranged from 2,103 K for oxygen-enriched flame to 1,339 K for $N_2-diluted$ flame. The visible flame length and the height of the main reaction zone were characterized by direct photographs. The characteristics of synthesized $TiO_2$ nanoparticles were analyzed by SEM and TEM images. From these images, it was evident that the formed nanoparticles were divided into two sorts. In the higher temperature region, over the 1,700 K, $TiO_2$ nanoparticles having spherical shapes with diameters about 60 nm were synthesized. In the lower temperature region, below the 1,600 K, the diameters of formed nanoparticles having unclear boundaries were ranged from 35 - 50 nm.

  • PDF

예혼합 LPG/공기화염에서 연소생성물의 국소농도 및 화염온도특성 (Local Concentration and Flame Temperature Characteristics of Combustion Product in Premixed LPG/Air Flames)

  • 김태권;장준영
    • 한국자동차공학회논문집
    • /
    • 제9권4호
    • /
    • pp.77-84
    • /
    • 2001
  • Measurements of local CO, $CO_2$, $O_2$, $N_2$, $C_3$H$_{8}$, NOx concentrations and flame temperature are made for partially premixed flame with and without acoustic excitation. The CO, $CO_2$, $O_2$, $N_2$, and $C$_3$H_8$ concentrations are determined by thermal conductivity detection (Gas-chromatograph) and NOx concentrations are determined by chemiluminescent detection (NOx analyser). To measure local sample concentration, sampling probe was made by quartz with inlet diameter of 0.25mm. In the case of excitation, the visual shape of the flame is changed from laminar flame to turbulent-like flame. The flame length is also reduced, and the flame width becomes broad. In the observation of emission concentration without acoustic excitation, meanwhile, the $CO_2$ and NOx concentrations peak at flame front where the mixture meets with surrounding air, and the CO concentration is increasing at maximum position of CO2 concentration and peaks at the centerline of the burner. In the case of acoustic excitation, the $CO_2$ concentration is widely occurred at nozzle of the burner and is higher relative to unexcitation. The CO concentration is much reduced, but NOx concentration is more increasing. And flame temperature is higher relative to unexcitation. These are caused by enhancing of mixing with surrounding air due to excitation. However, in the case of acoustic excitation, the total NOx concentration is reduced because of the shortened flame length which affects residence time.e.

  • PDF