• 제목/요약/키워드: Maximum efficiency control

검색결과 779건 처리시간 0.037초

저일사강도에서 MPPT를 동작시키기 위한 알고리즘 연구 (A Study of MPPT algorithm for Low-insolation)

  • 김기현;유권종;정영석;김영석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.473-475
    • /
    • 2001
  • This paper proposed a MPPT ( Maximum Power Point Tracking) control algorithm for PV(Photovoltaic) array based on a modified constant voltage control MPPT algorithm at low-insolation. This method which combines a IncCond(Incremental Conductance) and a constant voltage control algorithm. In contrast to the typical conventional MPPT algorithm, the proposed method have been obtained high efficiency and good performance. The proposed algorithm is verified through simulation result. In order to confirm the availability of the scheme, a simulation used PSIM and ACSL software tool.

  • PDF

통신기반 열차 제어시스템의 이동폐색에 관한 연구(지능형 열차제어시스템) (A Study on Moving Block using Communication based Train Control System (Intelligence Train Control System))

  • 채행석;심원섭;이종우
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(III)
    • /
    • pp.574-580
    • /
    • 2003
  • This research heightens use efficiency of existent train railroad equipment by maximum through communication based train control system, and because system that take advantage of new skill compares with safety of old signal system same or it that show that is high be. Examined MBS Embodiment method of most suitable by presenting calculation that find out location of train that this treatise runs free curved line department to embody MBS(Moving Block System) through communication

  • PDF

LED 조명용 정전류 SMPS 개발 (Development of constant current SMPS for LED Lighting)

  • 신현용
    • 한국전자통신학회논문지
    • /
    • 제10권1호
    • /
    • pp.111-116
    • /
    • 2015
  • 본 연구에서는 실내조명을 위한 LED 조명용 정전류 컨버터를 설계하고 제작된 SMPS의 전기적 특성을 측정하였다. 출력전류가 300mA 일 때 최대 85%의 효율을 나타내었으며 100~400mA의 범위에서는 70% 이상의 효율을 나타내었다. 또한 0~250mV의 제어신호를 이용하여 디밍레벨 0~100%의 범위를 모두 제어할 수 있었다.

새로운 무손실 스너버 커패시터를 이용한 고효율 스텝 업 AC-DC 초퍼에 관한 연구 (A Study on Novel Step-Up AC-DC Chopper of High Efficiency by using Lossless Snubber Capacitor)

  • 곽동걸;김상훈
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.1103-1104
    • /
    • 2008
  • In this paper, authors propose a novel step-up AC-DC chopper operated with power factor correction (PFC) and with high efficiency. The proposed chopper behaves with discontinuous current control (DCC) of input current. The input current waveform in the proposed chopper is got to be a discontinuous sinusoid form in proportion to magnitude of ac input voltage under the constant duty cycle switching. Therefore, the input power factor is nearly unity and the control method is simple. In the general DCC chopper, the switching devices are turned-on with the zero current switching, but turn-off of the switching devices is switched at current maximum value. To achieve a soft switching of the switching turn-off, the proposed chopper is used a new partial resonant circuit. The result is that the switching loss is very low and the efficiency of chopper is high.

  • PDF

Harmonics Reduction in Load control and Management system

  • Thueksathit, W.;Tipsuwanporn, V.;Hemawanit, P.;Gulpanich, S.;Srisuwan, K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2283-2286
    • /
    • 2003
  • This paper presents conservation of electrical energy in building with harmonics analysis and compensation which occur in electrical system. We use load controlling and management system in order to adjust load factor of system.The maximum demand limiting and controlling are used ,then the system can acquire the prediction and compare it to the maximum demand set point.The electrical signal analysis based on FFT technique. The harmonics are compensated by using harmonic filters.This system consists computer which works as controller, processor , analysis and database unit together with digital power meter in form of multidrop network through serial communication via RS-485.The load control system uses PLC to control load via serial communication RS-485. The A/D converter is used for sampling the electrical signals via parallel port of computer.The harmonic filters are controlled by a computer.The data of measurement such as voltage, current, power, power factor, total harmonic distortion, energy, etc., can be saved as database and analysis. The load factor is adjusted by limiting and controlling maximum demand. The load factor adjustment can reduce the cost of electric consumption and energy generation together with harmonics compensation in order to increase high efficiency of electrical system.

  • PDF

Power Balance 조건을 이용한 부스트 컨버터의 효율 분석 (Efficiency analysis of the boost converter using power balance condition)

  • 이국선;최익;최주엽;송승호;안진웅
    • 한국태양에너지학회 논문집
    • /
    • 제31권2호
    • /
    • pp.120-127
    • /
    • 2011
  • Solar array has the following nonlinear characteristic, such as whose output current increases, output voltage is reduced. For this reason, boost converter with solar array system is always controlled to remain on the maximum power point of the solar array. In this case, we are not focused on the output of the solar array and not consider efficiency of the boost converter, which is assumed reliable. But efficiency of the converter also should be considered, which affects the total efficiency of the overall solar energy system. In this paper, efficiency calculation of the boost converter using power balance method is proposed, which will be used for a powerful reference before hardware realization.

비례밸브를 이용한 트랙터 견인력제어시스템 개발 (Development of a Draft Control System for Tractor Using a Proportional Valve)

  • 이상식;이제용;문정환
    • Journal of Biosystems Engineering
    • /
    • 제31권1호
    • /
    • pp.9-15
    • /
    • 2006
  • Draft control is key technique in plow control system for automation of implement control system. To make the consistent draft force is an essential factor for preventing the reduction of working efficiency by tractor's slip and also improving the working efficiency. Therefore, the purpose of this study is to develop the draft sensor for draft control of plow and evaluate the usability of the algorithm of draft control system using proportional control valve. The developed draft control system could extract the draft force very well regardless of draft condition, change of setting draft force and response time in the response characteristic test. The maximum draft force at 3-Point linkage was 10,000 N and the deviation of the control system was 125.8 N in steady state condition. The developed control system worked very well with regard to the change of draft force in field and even in soil condition with soil reaction. The results of experiment showed the characteristics of response was sufficient to be used as the implement draft control system for tractor using proportional valve.

A New Approach to Improve Induction Motor Performance in Light-Load Conditions

  • Hesari, Sadegh;Hoseini, Aghil
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권3호
    • /
    • pp.1195-1202
    • /
    • 2017
  • Induction motors often reach their maximum efficiency at the nominal load. In most applications, the machine load is not equal to the nominal load, thus reduces the motor efficiency and turns a greater percent of power into loss. In this paper, the induction motor control problem has been investigated to reduce the system losses. The Field Oriented Control method (FOC) has been employed in this paper. In this research, the mathematical equations related to system losses are calculated in relation to torque and speed, and then the q- and d-axis are summarized according to the current components. After that, the proposed method is applied along with d- and q-axis. In the recent three decades, many techniques have been suggested to improve the induction motor performance using smart and non-smart methods. In this paper, a new PSO-Fuzzy method have used in real time. The fuzzy logic method serves as speed controller in q-axis and PSO algorithm controls the optimum flux in d-axis. It will be proved that the use of this combined method will lead to a significant improvement in motor efficiency.

PLL 기반 PWM/PFM 통합 제어 방식의 벅 컨버터 (A Buck Converter with PLL-based PWM/PFM Integrated Control)

  • 허정;정항근
    • 대한전자공학회논문지SD
    • /
    • 제49권8호
    • /
    • pp.35-40
    • /
    • 2012
  • DC-DC 컨버터에서 넓은 범위의 부하에 대하여 높은 효율을 유지하기 위해서는 PWM과 PFM을 함께 사용하는 듀얼 모드 제어 방식이 흔히 사용된다. 듀얼 모드 벅 컨버터는 부하 조건에 따라서 PWM이나 PFM을 선택해서 동작하므로, 모드 제어를 위한 부가 회로로 인하여 칩 면적이 증가하고 제어 방식이 변경되는 구간에서는 최적화된 효율을 얻을 수 없다. 본 논문에서는 전류 모드의 PWM 제어 회로에서 사용하는 발진기 대신에 PLL 기반의 발진기를 사용함으로써 추가적인 제어 회로 없이 PWM과 PFM의 통합된 제어 방식으로 동작하는 벅 컨버터를 제안함으로써 듀얼 모드 벅 컨버터의 단점을 해결했다. 제안한 통합 제어 방식의 벅 컨버터는 PSIM 시뮬레이션을 통하여 검증하였으며, 설계된 벅 컨버터 회로를 Cadence Spectre로 시뮬레이션 결과 250mA의 부하에서 최대 효율은 94.7%이고 10mA의 경부하에서 효율은 85.4%이다.

DC 나노그리드에서 Droop제어를 적용한 80kW급 양방향 하이브리드-SiC 부스트-벅 컨버터 개발 (Development of 80kW Bi-directional Hybrid-SiC Boost-Buck Converter using Droop Control in DC Nano-grid)

  • 김연우;권민호;박성열;김민국;양대기;최세완;오성진
    • 전력전자학회논문지
    • /
    • 제22권4호
    • /
    • pp.360-368
    • /
    • 2017
  • This paper proposes the 80-kW high-efficiency bidirectional hybrid SiC boost/buck converter using droop control for DC nano-grid. The proposed converter consists of four 20-kW modules to achieve fault tolerance, ease of thermal management, and reduced component stress. Each module is constructed as a cascaded structure of the two basic bi-directional converters, namely, interleaved boost and buck converters. A six-pack hybrid SiC intelligent power module (IPM) suitable for the proposed cascaded structure is adopted for high-efficiency and compactness. The proposed converter with hybrid switching method reduces the switching loss by minimizing switching of insulated gate bipolar transistor (IGBT). Each module control achieves smooth transfer from buck to boost operation and vice versa, since current controller switchover is not necessary. Furthermore, the proposed parallel control using DC droop with secondary control, enhances the current sharing accuracy while well regulating the DC bus voltage. A 20-kW prototype of the proposed converter has been developed and verified with experiments and indicates a 99.3% maximum efficiency and 98.8% rated efficiency.