• 제목/요약/키워드: Maximum anchorage

검색결과 88건 처리시간 0.025초

탄소섬유 Rod로 성능향상된 R/C보의 휨 거동 연구 (The Study on Flexural Behavior of Reinforced Concrete Beams Strengthened with the Carbon Fiber Rod)

  • 심종성;문도영;김영호;김동희
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.611-616
    • /
    • 2002
  • The concrete beam is quickly required to be replaced or strengthened due to decreasing load carrying capacity. Flexural tests on 3.1m long reinforced concrete beams with carbon-fiber rod are reported. The selected experimental variable is the method of the anchoring beam. The effects of this variable in overall behavior are discussed. This paper considered relation of load-displacement and load-strain. The maximum load was increased to the static behavior of the R/C beam strengthened with CFR rod. The results indicated generally that the flexural strength of strengthening beam was increased. It was required a proper anchorage system and can be led the ductility of beams of a carbon-fiber rod.

  • PDF

탄소격자섬유를 이용한 RC 깊이보의 정적파괴실험 (Static loading test of R/C deep beams with CFRP-Grids)

  • 조병완;김영진;태기호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회논문집(II)
    • /
    • pp.567-572
    • /
    • 1998
  • Structural behavior of R/C deep beams was investigated and compared to those of specimens with CFRP Grids. Test results show that the crushing of compression strut for the unstrengthened R/C deep beams is changed to the group of several diagonal cracks at mid-depth within the sheat span. Strengthened specimens grow to be more ductile after the redistribution of internal force on the CFRP Grids. The failure mode and variations of strains in the specimens are dependent on the shear span-to-depth ratio. The lower the shear span-to-depth ratio, the bigger failure load and the less variations in strain are observed. Additional anchorage of CFRP Grids does not only cause the improvement in the internal resistance, but also control the brittle shear failure of specimen after reaching the maximum loads.

  • PDF

국내산 7연강선의 트렌스퍼 정착부착 실험 (Transfer Bond test on Domestic Sevenwire Prestressing Strands)

  • 김승욱;김대훈;유재천;유승룡
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.387-392
    • /
    • 1999
  • The bond performance of prestressing strands is still not well understood and is still in controversy on the validity of the test results up to today, although it is a basic information to desing the prestressed pretensioned concrete beams. Different transfer length has been found for a product of the same company, but of the different production methods and factories in the United States. It is necessary to determine optimum transfer bond length of the domestic stands because the ultimate flexural and shear capacity in a section of prestressed concrete beams are evaluated under the assumption that the anchorage bond failure shall not happen. The transfer lenght of low-relaxation, Gr 270, and 1/2" seven-wire prestressing strands from four domestic companies will be evaluated by the concrete strain method. The recent concept of the 95% Maximum Average Strain Method suggested by Russel et al. will be considered to obtain the transfer length of domestic strands. It will be also evaluated if the domestic strands are conform to ACI 318-95.8-95.

  • PDF

비부착 탄소섬유판 긴장재를 갖는 철근 콘크리트 보의 휨거동 (Flexural behavior of RC beams with unbonded prestressing CFRP laminates)

  • 박종섭;박영환;정우태
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.258-261
    • /
    • 2006
  • This study investigates the flexural behavior and strengthening performance of RC beams with unbonded prestressing CFRP laminates through static bending tests. The aluminum anchorage system has been developed in tins study and successfully applied to the test specimens. The prestressing level of CFRP laminatehas was 0 %, 20 %, 30% and 50 % of its tensile strength. Experimental results revealed that RC beams with unbonded prestressing CFRP laminates showed increased crack load and yield load according to the level of prestress. It has also been observed that the length of the CFRP laminates does not have significant effect on the maximum load.

  • PDF

Comparative experimental assessment of seismic rehabilitation with CFRP strips and sheets on RC frames

  • Kakaletsis, D.J.
    • Earthquakes and Structures
    • /
    • 제10권3호
    • /
    • pp.613-628
    • /
    • 2016
  • The effectiveness of the use of modern repair schemes for the seismic retrofit of existing RC structures were assessed on a comparative experimental study of carbon fiber-reinforced polymer (CFRP) strips and sheets for the repair of reinforced concrete members of RC frames, damaged because of cyclic loading. Two virgin, single - story, one - bay, 1/3 - scale frame specimens were tested under cyclic horizontal loading, up to a drift level of 4%. Then, virgin specimens, B and F, respectively, were repaired and retested in the same way. One, specimen RB, was repaired with epoxy injections and CFRP strips and one, specimen RF, was repaired with epoxy injections and CFRP sheets. The two specimens are used to examine the differences between the structural behavior of frames repaired using CFRP strips and frames repaired using CFRP sheets. Both qualitative and quantitative conclusions, based on the observed maximum loads, loading and reloading stiffness, hysteretic energy absorption and failure mechanisms are presented and compared. The repaired frames recovered their strength, stiffness and energy dissipated reasonably. The use of CFRP sheets was found more effective than CFRP strips, due to the proper anchorage.

강섬유 혼입률에 따른 철근콘크리트 외부 보-기둥 접합부의 내진성능에 대한 실험적 연구 (An Experimental Study on the Seismic Performance of Reinforced Concrete Exterior Beam-Column Joint with Steel Fiber Volume Fractions)

  • 이장재;배백일;최창식
    • 대한건축학회논문집:구조계
    • /
    • 제34권4호
    • /
    • pp.15-23
    • /
    • 2018
  • The purpose of this study is to evaluate the anchorage capacity of longitudinal bars for reinforced concrete exterior beam - column joints with steel fiber volume fractions. For this purpose, the steel fiber volume fraction was set to 0, 1, 2%, and the performance was compared with that of each other specimens. According to the test results, the maximum strength of EX-HK-NJR-0 decreased by 13% compared with the control specimen and EX-HK-NJR-1 decreased by 3% compared to the control specimen. However, when 2% of steel fiber was mixed, the maximum strength increased about 56% compared to the control specimen. The energy dissipation capacity of EX-HK-NJR-0 (when no transverse steel bars are placed) decreased by 61% compared to the control specimen. In addition, the energy dissipation capacity of the specimens with a steel fiber content of 1% decreased by 5% and 2% increased by 94% compared to control specimen. EX-HK-NJR-1,2 and the control specimen EX-HK-JR-0 experienced yielding of the reinforcing bars at the column interface before maximum strength development. However, when the EX-HK-NJR-0, the reinforcing bars at the column interface experienced yielding after maximum strength development. Therefore, reinforcement of steel fiber is considered to reduce the required development length for yielding of steel bars.

보-기둥 접합부에 정착된 550 MPa 43 mm 갈고리철근의 거동 (Behavior of 550MPa 43mm Hooked Bars Embedded in Beam-Column Joints)

  • 배민서;천성철;김문길
    • 콘크리트학회논문집
    • /
    • 제28권5호
    • /
    • pp.611-620
    • /
    • 2016
  • 철근항복강도가 420 MPa만 사용되는 원자력발전소는 대구경 철근이 과밀 배근되어 정밀시공이 어렵고 콘크리트구조물의 품질저하가 우려된다. 과밀배근 해소를 위해 항복강도 550 MPa 철근의 사용이 필요하다. 이 연구에서는 550 MPa 고강도철근의 실용화를 위해 요구되는 여러 검토 항목 중, 철근과 콘크리트 일체 거동을 위해 필요한 43 mm 갈고리철근의 정착거동을 실험적으로 평가하였다. 실험체 모두 목표했던 측면파열파괴가 발생하여, 최대하중에서 측면 피복두께가 급격히 탈락하였다. 가력 초기에는 대부분의 하중을 직선구간의 부착에 의해 지지하였으나, 최대 하중의 1/3 지점부터 부착에 의한 기여도가 저감되기 시작하여 최대 하중에서는 대부분 갈고리 지압에 의해 하중을 지지하였다. 횡보강철근이 있는 실험체에서 [실험값]/[콘크리트구조기준 예측값] 비율의 평균이 1.45였다. 35 mm 초과 철근에 적용이 금지된 횡보강철근에 대한 보정계수 0.8을 적용하여도 안전한 갈고리 정착이 가능하다. 고강도콘크리트를 사용한 경우에는 [실험값]/[콘크리트구조기준 예측값]의 비율이 1.0로 다른 경우에 비해 안전율이 부족하였다. 콘크리트강도의 제곱근에 비례하는 콘크리트구조기준은 고강도 콘크리트에서 안전측이 아니므로 콘크리트 압축강도에 대한 영향을 저감시킬 필요가 있다. 실험결과를 회귀분석하여, 콘크리트 압축강도, 묻힘길이, 측면피복두께, 횡보강철근의 영향을 고려한 갈고리철근 정착강도 평가식을 개발하였다. 13개 실험데이터와 비교한 결과, [실험값]/[예측값] 비 평균이 1.0, 변동계수가 10%로 매우 정확히 강도를 예측하였다.

중공트랙형 단면의 프리캐스트 에코필라 사방댐 공법개발 (Development of Precast Concrete Method for Eco-Pillar Debris Barrier with Hollow Cross-Section)

  • 김현기
    • 한국산학기술학회논문지
    • /
    • 제19권3호
    • /
    • pp.542-552
    • /
    • 2018
  • 본 연구에서는 현장타설 콘크리트를 사용하는 친환경 에코필라 사방댐의 시공성과 경제성을 향상시키기 위해 프리캐스트공법을 제안하고 성능검증을 수행하였다. 강재를 이용한 사방댐 형식은 공사비가 높고 부식으로 인한 환경문제도 발생하고 있어, 최근에는 콘크리트를 이용한 친환경 사방댐의 설치가 늘고 있다. 그러나 국내에서 사방댐 설계기준으로 명확하게 제시된 자료가 없어 경험적으로 설계되고 있을 뿐 아니라 에코필라 사방댐에 대한 기준은 전무한 실정이다. 따라서 본 연구에서 에코필라 사방댐의 설계외력 산정방법에 대해 제안하고 중공트랙형 단면을 적용하여 설계를 수행하였다. 또한, 구조적으로 비교적 간단한 캔틸레버 기둥으로 최대 휨모멘트가 작용하며 프리캐스트 공법의 핵심기술이라 할 수 있는 연결부 공법을 3가지로 제안하고 실물모형 실험을 통해 성능검증을 수행하였다. 실험결과, 루프철근 이음을 적용한 실험체가 가장 큰 강성을 보였고 앵커철근으로 연결된 실험체가 작은 값을 보였으나, 제시된 3가지 형태의 연결공법은 모두 극한하중에 따른 최대 휨모멘트를 충분히 넘어서는 성능을 나타내었다. 실물 실험체의 제작과정에서 각 공법에 대한 시공성에 대해 검토한 결과 앵커식 연결방법이 가장 우수한 것으로 평가되었다.

미니플레이트의 골내 고정원 적용 시 초기 안정성에 영향을 주는 요인에 대한 3차원 유한요소법적 연구 (Factors influencing primary stability of miniplate anchorage: a three-dimensional finite element analysis)

  • 이남기;최동순;장인산;차봉근
    • 대한치과교정학회지
    • /
    • 제38권5호
    • /
    • pp.304-313
    • /
    • 2008
  • 본 연구는 골내 고정원으로 사용하는 미니플레이트 시스템의 초기 안정성에 영향을 주는 요인에 대해 알아보기 위해 시행하였다. 미니플레이트의 고정에 사용되는 미니스크류의 길이, 수 및 적용되는 교정력의 방향에 따른 골내 응력 분포 양상과 미니스크류의 변위 정도를 분석하기 위하여 3차원 유한요소분석을 시행하였다. 단순화한 골 모델에 6 hole의 곡선형 미니플레이트를 위치하고 직경 2 mm의 미니스크류로 고정하되 각각 6 mm와 4 mm 길이의 두 가지 종류로 세 개 또는 두 개로 고정한 총 네 개의 유한요소모델을 제작한 후 각각의 모델에서 4 N의 교정력을 미니플레이트의 고정되지 않은(unfixed) 가장 원심측 두개의 hole을 연결한 가상의 축에 대해 $0^{\circ}$, $30^{\circ}$, $60^{\circ}$, $90^{\circ}$ 방향으로 각각 적용하였다. 미니플레이트를 고정하는 미니스크류가 동일 길이일 경우 개수가 작을수록, 동일 개수일 경우 길이가 짧을수록 골에 나타나는 최대 응력과 미니스크류의 최대 변위가 증가되었다. 골에 나타나는 최대 응력은 해면골에 비해 피질골에 집중되어 응력의 대부분은 피질골에서 흡수되었다. 미니플레이트의 가상의 축에 대해 교정력의 견인 방향이 증가할수록 골내의 최대 응력과 미니스크류의 최대 변위가 증가되었다. 골내의 최대 응력과 미니스크류의 최대 변위는 적용된 견인력 지점에서 가장 가까운 미니스크류 고정 부위였다. 이상의 결과로 미니플레이트 시스템의 초기 안정성을 위해 2 mm 직경의 미니스크류를 사용 시 4 mm 보다는 6 mm 길이의 미니스크류를, 2개보다는 3개 식립하는 것이 더 유리하며, 미니플레이트의 가상의 축에 대해 적용하는 교정력의 견인방향이 가급적 일치되도록 미니플레이트를 위치시키는 것이 좋을 것으로 생각된다.

Wind-induced vibration fragility of outer-attached tower crane to super-tall buildings: A case study

  • Lu, Yi;Zhang, Luo;He, Zheng;Feng, Fan;Pan, Feng
    • Wind and Structures
    • /
    • 제32권5호
    • /
    • pp.405-421
    • /
    • 2021
  • To gain insight into the wind-induced safety concerns associated with attached tower cranes during the construction of super-tall buildings, a 606 m level frame-core tube super-tall building is selected to investigate the wind-induced vibration response and fragility of an outer-attached tower crane at all stages of construction. The wind velocity time history samples are artificially generated and used to perform dynamic response analyses of the crane to observe the effects of wind velocity and wind direction under its working and non-working resting state. The adverse effects of the relative displacement response at different connection supports are also identified. The wind-resistant fragility curves of the crane are obtained by introducing the concept of incremental dynamic analysis. The results from the investigation indicate that a large relative displacement between the supports can substantially amplify the response of the crane at high levels. Such an effect becomes more serious when the lifting arm is perpendicular to the plane of the connection supports. The flexibility of super-tall buildings should be considered in the design of outer-attached tower cranes, especially for anchorage systems. Fragility analysis can be used to specify the maximum appropriate height of the tower crane for each performance level.