• Title/Summary/Keyword: Maximum amplitude

Search Result 757, Processing Time 0.024 seconds

A numerical analysis and experimental study on the prediction of spray characteristics (분무특성 예측을 위한 이론적 접근과 실험적 연구)

  • Yoon, S.J.;Cho, D.J.
    • Journal of ILASS-Korea
    • /
    • v.3 no.2
    • /
    • pp.1-13
    • /
    • 1998
  • A theoretical and experimental study was carried out to predict the drop size distribution of the pressure swirl atomizer. Various analytical methods using the Kelvin-Helmholtz instability theory were tried to examine the wave growth on cylindrical liquid sheets. Cylinderical liquid sheets were extended to the case with the conical sheets. Perturbations due to tangential motion as well as longitudinal one were taken into account. And it was assumed that the breakup occurs when amplitude ratio exceeds exp(12), drop sizes were predicted only by theoretical approach. Drop size distribution was obtained by using maximum entropy formalism. Seven constraints in the form of the definition of mean diameter were used in this formulation in order to avoid the difficulties of estimating source terms. In this study $D_{10}$ only was introduced into the formulation as a constraint. The predicted drop size and drop size distribution agreed well with the measured data.

  • PDF

Study on Structural Analysis of Flywheel under Rotary Power (회전력을 받는 플라이휠의 구조해석에 관한 연구)

  • Han, Moon-Sik;Cho, Jae-Ung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.2
    • /
    • pp.137-143
    • /
    • 2012
  • This study analyzes flywheel through the analyses of stress, fatigue and vibration. Maximum equivalent stress is 15.271MPa at the mid round shape and maximum deformation is 0.02264mm at the outer teeth. Among the cases of nonuniform fatigue loads, 'SAE bracket history' with the severest change of load becomes most unstable but 'Sample history' becomes most stable. In case of 'Sample history' with the average stress of -$10^4$MPa and the amplitude stress of 1000 to 2900MPa, the possibility of maximum damage becomes 30%. This stress state can be 20 times greater than the damage possibility of 'SAE bracket history' or 'SAE transmission'. The range of natural frequencies becomes 200 to 820Hz and the values of these deformations are not more than 10mm. The structural result of this study can be effectively utilized with the design of flywheel by investigating prevention and durability against its damage.

Study of Maximum Torque Operation of Interior Permanent Magnet Synchronous Motor in Constant Torque Region (매입형 영구자석 동기전동기의 일정 토크 영역에서 최대 토오크 운전에 관한 연구)

  • Kim, Jang-Mok;Kim, Su-Yeol;Ryu, Ho-Seon;Im, Ik-Hun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.3
    • /
    • pp.195-203
    • /
    • 2000
  • In this paper a new controller is proposed to operate the interior permanent magnet synchronous motor(IPMSM) by the control method of the maximum torque per ampere in constant torque region. The implementation method of the conventional torque controller is explained and analyzed exactly. The proposed controller does not use the torque and q-axis current of the speed controller but the amplitude of the stator current in order to utilize not only the magnetic alignment torque but also the reluctance in the constant region, gurantees the linearity of the torque, and is easily implemented. These attractive are verified through the experiment.

  • PDF

Structural Analysis on Control Arm of Automobile under Nonuniform Fatigue Load (불규칙 피로 하중을 받는 자동차의 컨트롤 암의 구조 해석)

  • Cho, Jae-Ung
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.3
    • /
    • pp.87-92
    • /
    • 2011
  • This study analyzes structural stress and fatigue on control arm of automobile under nonuniform load. Maximum equivalent stress at bolt part is shown with 419.1MPa and the corner is deformed with maximum displacement of 1.1628mm. Among 3 cases of nonuniform fatigue loads applying on control arm, 'SAE bracket history' with the severest change of load becomes most unstable but 'Sample history' becomes most stable. In case of 'Sample history' with the average stress of $-10^5MPa$ to $10^5MPa$ and the amplitude stress of 0 MPa to $10^5MPa$, the possibility of maximum damage becomes 3%. This stress state can be shown with 6 times more than the damage possibility of 'SAE bracket history' or 'SAE transmission'. Safety and durability on automobile can be effectively improved by applying the fatigue analysis result on control arm.

A STUDY ON THE EFFECTS OF TEXTURE OF FOOD ON CHEWING MOVEMENTS AND EMG OF MASTICATORY MUSCLE (식품의 물성이 제작근의 활성도 및 저작 양태에 미치는 영향)

  • Cho, Lee-Ra;Kim, Kwang-Nam;Chang, Ik-Tae;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.3
    • /
    • pp.427-452
    • /
    • 1998
  • To elucidate the effects of food texture such as hardness, cohesiveness, adhesiveness on mastication procedure, the electromyographic activity (EMG) of the masticatory muscles and the chewing movements were analyzed in eighteen young subjects during ordinary chewing. Seven different foods were selected by sensory texture profiling and mechanical test with texturometer; egg white, sausage, pizza cheese, yang-geng, biscuit, peanut and almond. The indexes of jaw movements used were the chewing number, chewing time, maximum opening, average opening, closing velocity and opening velocity. The EMG indexes analyzed were maximum and average integrated amplitude of the anterior temporal and masseter muscles. The results obtained were as follows. 1. The chewing time and chewing number, mandibular displacement and mandibular movement velocity were not changed by the hardness, cohesiveness and adhesiveness of the food (p>0.05). 2. The harder food materials showed a higher amplitude of the anterior temporal muscle integrated EMGs than the softer ones (p<0.05). 3. The maximum and average integrated EMGs of the masseter muscle increased with the increase of hardness of the food (p<0.05). 4. The integrated EMGs of preferred side and non-preferred side masticatory muscles increased with the increase of hardness of the food (p<0.05). 5. The adhesiveness and cohesiveness of the food were not the determining factor to the integrated EMGs of masticatory muscles (p<0.05).

  • PDF

The effect of shaded apodizer on the read-out signal in an optical dise system (Shaded apodizer가 광학 디스크 시스템의 wotodf 신호에 미치는 영향)

  • 박성종;심상현
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.6
    • /
    • pp.443-447
    • /
    • 1999
  • To investigate the effect of a shaded apodizer on the read-out signal in an optical disc system, we consider the is apodizer in which the amplitude transmittance decreases gradually from the center of pupil toward its edge and the iH apodizer in which the amplitude transmittance increases gradually from the center of pupil toward its edge, using the scalar diffraction theory. We also consider the bump shapes which are a cylindric, a semi-conic, and a conic bump, and bump height which is given by $\lambda/4$ and occurs to the phase change $(\pi)$). The read-out signal of is apodizer increases from S = 0 upto maximum value, and then decreases for increasingly larger values of bOo While the iH apodizer has two maximum values. When an optical disc system has a spherical aberration $(W_{40}=0.5\lambda)$, the maximum read-OUt signal of is apodizer is higher than that of iv apodizer which has no apodizer.odizer.

  • PDF

Changes of Mandibular Movement and TMJ Sound on Head and Neck Posture (두경부 위치에 따른 하악운동 및 측두하악관절음의 변화)

  • 나홍찬;최종훈;김종열
    • Journal of Oral Medicine and Pain
    • /
    • v.22 no.1
    • /
    • pp.95-109
    • /
    • 1997
  • The purpose of this research is to investigate the influence on mandibular movements and TMJ sounds with changes of head and neck posture. For the research, twenty patients who had complained of TMJ sounds without any other symptoms of cranio-mandibular disorders, were selected as subjects for measurements of TMJ sounds, and radiographs on transcranial view of TMJ were taken on ten of the subjects. From NHP, UHP, DHP and FHP, aspects of mandibular movement and TMJ sound were investigated from each posture. Aspects of mandibular movement and TMJ sound were observed by measuring total vibration energy(Integral), peak amplitude, maximum amound of mouth opening, and TMJ sound-emitting point using Sonopak for windows (version 1.33) and Bio-EGN(Bioresearch Inc. WI. U.S.A.). Head and neck movement-measuring instrument, CROM(perfomance attainment Inc. U.S.A.) was to maintain even head posture. Degrees of inclination of UHP and DHP were determined at 30' and distance of FHP was 4cm. The results obtained were as follows. 1. Total vibration energy and peak amplitude of TMJ sounds were decreased more on UHP and on UHP and increased more on DHP and FHP than that on NHP. 2. At the maximum mouth opening, distance of TMJ sound-emitting point were decreased more on UHP and increased more on DHP and FHP than that on NHP. 3. The amounts of the maximum mouth opening were increased more on UHP and decreased more on DHP and FHP than that on NHP. 4. For the changes of the head posture with mouth opening observed in radiograph, condylar head was positioned more lower-anteriorly on UHP, and more upper-posteriorly on DHP and FHP than that on NHP. From the results obtained as above, considering positive influence of the change of head and neck posture, avoiding down-head and forward-head posture, and recommending upper- head posture can prevent the progress of temporomandibular disorder and lead to successful treatment for the patients with temporomandibular joint sounds.

  • PDF

Connection between the Amplitude Variations of the GPS Radio Occultation Signals and Solar Activity

  • Pavelyev, A.G.;Liou, Y.A.;Wickert, J.;Pavelyev, A.A.
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.348-357
    • /
    • 2008
  • The classification of the effect of ionospheric disturbances on the radio occultation signal amplitude has been introduced based on an analysis of more than 2000 seances of radio occultation measurements per formed with the help of the CHAMP German satellite. The dependence of the histograms of variations in the radio occultation signal amplitude on the IMF variation index has been revealed. It has been indicated that it is possible to introduce the radio occultation index characterizing the relation between ionospheric disturbances and solar activity. An amplitude radio occultation (RO) method is proposed to study connection between the ionospheric and solar activity on a global scale. Sporadic amplitude scintillation observed in RO experiments contain important information concerning the seasonal, geographical, and temporal distributions of the ionospheric disturbances and depend on solar activity. The probability of strong RO amplitude variations (RO $S_4$ index greater than 0.2) in the CHAMP RO signals diminishes sharply with the weakening of solar activity from 2001 to 2008. The general number of RO events with strong amplitude variations can be used as an indicator of the ionospheric activity. We found that during 2001-2008 the daily globally averaged RO $S_{4a}$ index depends essentially on solar activity. The maximum occurred in January 2002, minimum has been observed in summer 2008. Different temporal behavoir of $S_{4a}$ index has been detected for polar (with latitude greater than $60^{\circ}$) and low latitude (moderate and equatorial) regions. For polar regions $S_{4a}$ index is slowly decreasing with solar activity. In the low latitude areas $S_{4a}$ index is sharply oscillating, depending on the solar ultraviolet emission variations. The different geographical behavoir of $S_{4a}$ index indicates different origin of ionospheric plasma disturbances in polar and low latitude areas. Origin of the plasma disturbances in the polar areas may be connected with influence of solar wind, the ultraviolet emission of the Sun may be the main cause of the ionospheric irregularities in the low latitude zone. Therefore, the $S_{4a}$ index of RO signal is important radio physical indicator of solar activity.

  • PDF

Enhanced Pulse Amplitude Estimation Method for Electronic Warfare Support (전자전 지원을 위한 향상된 펄스 세기 추정 기법)

  • Lee, Yu-Ri;Kim, Dong-Gyu;Kwak, Hyungyu;Kim, Hyoung-Nam
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.3
    • /
    • pp.649-660
    • /
    • 2017
  • In electronic warfare, the pulse amplitude, one of information of a pulse signal emitted by an enemy, is used for estimating distance from the source and for deinterleaving mixed source signals. An estimate of pulse amplitude is conventionally determined as the maximum magnitude of a Fourier transformed signal within its pulse width which is estimated pre-step in an electronic warfare receiver. However, when frequency modulated signals are received, it is difficult to estimate their pulse amplitudes with this conventional method because the energy of signals is dispersed in frequency domain. In order to overcome this limitation, this paper proposes an enhanced pulse amplitude estimation method which calculates the average power of the received pulse signal in time domain and removes the noise power of the receiver. Simulation results show that even in case the frequency modulated signal is received, the proposed method has the same performance as estimating the pulse amplitude when unmodulated signal is received. In addition, the proposed method is shown to be more robust to an estimation error of pulse width, which affects the estimation performance of pulse amplitude, than the conventional method.

Increased Intraoperative Motor Evoked Potentials and Motor Recovery after Spinal Cord Tumor Removal (척수 종양 제거 술 중 운동유발전위의 호전과 근력 호전의 관계)

  • Pyo, Soeun;Park, Yoon Ghil;Park, Jinyoung;Ko, Eu Jeong
    • Journal of Electrodiagnosis and Neuromuscular Diseases
    • /
    • v.20 no.2
    • /
    • pp.98-105
    • /
    • 2018
  • Objective: To evaluate whether the increase of the amplitude of motor evoked potentials (MEPs) during surgery can imply favorable prognosis postoperatively in spinal cord tumor surgery. Method: MEPs were monitored in patients who underwent spinal cord tumor surgery between March 2016 and March 2018. Amplitude changes at the end of monitoring compared to the baselines in limb muscle were analyzed. Minimum and maximum changes were set to $MEP_{min}$ (%) and $MEP_{max}$ (%). Strengths of bilateral 10 key muscles which were documented a day before ($Motor_{pre}$), 48 h ($Motor_{48h}$) and 4 weeks ($Motor_{4wk}$) after the surgery were reviewed. Results: Difference of $Motor_{48h}$ from $Motor_{pre}$ ($Motor_{48h-pre}$) and $Motor_{4wk}$ from $Motor_{pre}$ ($Motor_{4wk-pre}$) positively correlated with $MEP_{min}$, suggesting that smaller the difference of MEPs amplitude, less recovery of muscle strength. There was a negative correlation between the amount of bleeding and $MEP_{min}$, indicating that the greater the amount of bleeding, the smaller the $MEP_{min}$, implying that MEPs amplitude is less likely to improve when the amount of bleeding is large. It also showed significant difference between patients with improved or no change of motor status and patients with motor deterioration after surgery according to anatomical tumor types. Conclusion: Improve of muscle strength was less when the increase of MEPs amplitude was small, and improvement of MEPs amplitude was less when the amount of bleeding was large. Correlation between changes of status of muscle strength after surgery and tumor types was observed. With amplitude increase in MEPs monitoring, restoration of muscle strength can be expected.