• Title/Summary/Keyword: Maximum Temperature Difference

Search Result 735, Processing Time 0.029 seconds

Performance of Thermoelectric Power Generator with Various Thermal Conditions (열전소자의 열적조건 변화에 따른 발전 특성)

  • Han, Hun-Sik;Kim, Myung-Kee;Um, Suk-Kee;Kim, Seo-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.3
    • /
    • pp.165-170
    • /
    • 2010
  • Experiments have been performed to investigate the key parameters determining the performance of thermoelectric power generation. The experimental results obtained show that the power output significantly increases with the temperature difference between cold and hot sides of thermoelectric generator. However, the effect of the hot side temperature under the identical temperature difference on the overall performance of a thermoelectric generator is meager. The conversion efficiency defined as the ratio of the power generated to the heat absorbed at the hot side increases with the temperature difference. The behavior of the thermoelectric generator is shown to be consistent with the theoretical analysis. The optimum current giving the maximum conversion efficiency and the maximum conversion efficiency are linearly increased with the temperature difference.

A Sutdy on Improvement of Geomeric Accuracy by using Fuzzy Algorithm in Surface Grinding (퍼지 알고리즘을 이용한 평면연삭의 형상정도 향상에 관한 연구)

  • 천우진;김남경;하만경;송지복
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.149-154
    • /
    • 1993
  • In heavy grinding that is on of the high efficient grinding method, meaningful deformation is generated by high temperature. So, after machining, geomeric error generated od the workpiece. The most important factor on the geometric error is temperature difference between upper layer and lower layer (T $_{d}$) . Relations between Td and grinding condition and maximum geometric error and grinding condition are obtained by experiment. This relations are used in fuzzy algorithm for improvement geometric accuracy. The main results are follows : (1) The linear relation between maximum geometric error and grinding condition is ovtained by experiment. (2) The linear relation between maximum temperature difference between upper layer and lower layer and grinding condition is ovtained by experiment. (3) Control peth of wheel for improvement geometric accuracy is obtained by using the fuzzy algorithm.m.

  • PDF

The Study of Infrared Thermography of a Mild Steel for Nondestructive Evaluation (적외선 카메라에 의한 연강의 비파괴 평가에 대한 연구)

  • Han, Jeong-Seb;Park, Jin-Hwan
    • Journal of Ocean Engineering and Technology
    • /
    • v.22 no.2
    • /
    • pp.72-77
    • /
    • 2008
  • The application of infrared thermography for detecting defects under the surface of a material was studied. Defects in a specimen were made by back-drilled circular holes. To get alarge temperature difference at the surface, a halogen lamp was used for surface heating. We confirmed that the defect location had a good relationship with the maximum temperature difference. The sizes of the defects could be calculated by means of the FWHM. The value of the FWHM of a temperature difference decreased with time. Therefore in an extremely short time after the heating, the true defect size could be measured.

Solid State Diffusion Brazing of the Aluminum Alloy Castings According to the Heat Treatment Conditions (열처리온도 및 시간에 따른 알루미늄 주조재의 고상확산 접합 특성)

  • Sun, J.H.;Shin, S.Y.;Hong, J.W.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.21 no.6
    • /
    • pp.300-306
    • /
    • 2008
  • Solid state diffusion brazing of aluminum castings (AC4C) and wrought alloys (Al6061) was conducted in order to improve thermal conductivity and temperature uniformity of the aluminum heater which was generally fabricated by casting method. Tensile strength and thermal conductivity are raised with increasing brazing temperature, obtaining 122.5 MPa and $206W/m{\cdot}K$ at $540^{\circ}C$ 5hrs brazing conditions, respectively. The diffusion brazed heater, shows maximum temperature difference of $4^{\circ}C$, exhibits a enhanced temperature uniformity compared with the cast heater having the maximum temperature difference of $11^{\circ}C$.

The Estimation of Urbanization Effect in Global Warming over Korea using Daily Maximum and Minimum Temperatures (최고, 최저기온을 이용한 우리나라 기온변화에서의 도시화효과 분석)

  • Koo, Gyo-Sook;Boo, Kyung-On;Kwon, Won-Tae
    • Atmosphere
    • /
    • v.17 no.2
    • /
    • pp.185-193
    • /
    • 2007
  • This study investigates urbanization effect in warming trend of surface air temperature over Korea. The data used in this study consist of the daily minimum and maximum temperatures during the period of 32 years(1968-1999) from 16 stations of KMA. To calculate magnitude and trend of urbanization effect, stations were classified into urban and rural stations using population statistics. Urban stations were defined as those with population densities greater than 1000 persons per kilometer squared in 1995. The others were defined as rural stations. The urban stations were also subdivided into two groups according to their population totals. For estimates of urban effect magnitude, temperature change was calculated by comparing 16-year mean values between 1968-83 and 1984-99. Then, the difference between each urban station and every rural station was calculated. During the analysis period of 32 years, maximum temperature increase is $1.22^{\circ}C$. In the total temperature increase, urban effect is estimated by 28.7%. For minimum temperature, it becomes larger by about 10% than that in maximum temperature. Therefore, urban effect in an increasing trend of minimum temperature is 38.9% in the change of $1.13^{\circ}C$.

Mock-up Test on the Reduction of Hydration Heat of Mass Concrete for Transfer Girder (전이보 매스콘크리트의 수화열 저감에 관한 Mock-up 실험)

  • Yoon Seob;Hwang Yin Seong;Baik Byung Hoon;Han Cheon Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.707-710
    • /
    • 2004
  • This paper reported the results of mock-up test on mass concrete for transfer girder using setting time difference of super retarding agent(SRA). According to test results, two mock-up structures were made. Plain concrete without placing layer reached maximum temperature after 24hours since placement and caused surface hydration cracks at top section. However, concrete with placing layer reached maximum temperature after 72hours and surface temperature was higher than center temperature, which did not cause surface crack. After form removing, no crack was observed at side surface of plain concrete, while concrete using SRA at mid section had surface scaling and settling crack. According to coring results, concrete with placing layer had a penetration crack from top section to bottom section. Therefore, the setting time difference method to reduce hydration heat will have difficulty in applying the mass concrete for transfer girder.

  • PDF

Greenhouse Heating Characteristics of Heat Pump-Latent Heat Storage System (열펌프-잠열축열 시스템의 온실 난방 특성 연구)

  • 강연구;송현갑
    • Journal of Biosystems Engineering
    • /
    • v.25 no.5
    • /
    • pp.379-384
    • /
    • 2000
  • In order to use the natural thermal energy as much as possible for greenhouse heating, the air-air heat pump system involved PCM(phase change material) latent heat storage system was composed, and three types of greenhouse heating system(greenhouse system, greenhouse-PCM latent heat storage system, greenhouse-PCM latent heat storage-heat pump system) were recomposed from the greenhouse heating units to analyze the heating characteristics. The results could be concluded as follows; 1) In the greenhouse heated by the heat pump under the solar radiation of 406.39W/$m^2$, the maximum PCM temperature in the latent heat storage system was 24$^{\circ}C$ and the accumulated thermal energy stored in PCM mass of 816kg during the daytime was 100,320kJ. In the greenhouse without heat pump under the maximum solar radiation of 452.83W/$m^2$, the maximum PCM temperature in the latent heat storage system was 22$^{\circ}C$ and the accumulated thermal energy stored during the daytime was 52.250kJ. 2) In the greenhouse-PCM system without heat pump the heat stored in soil layers from the surface to 30cm of the soil depth was 450㎉/$m^2$. 3) In all of the greenhouse heating systems, the difference between the air temperature in greenhouse and the ambient temperature was about 20~23$^{\circ}C$ in the daytime. In the greenhouse without heat pump and PCM latent heat storage system the difference between the ambient temperature and the air temperature in the greenhouse was about 6~7$^{\circ}C$ in the nighttime, in the greenhouse with only PCM latent heat storage system the temperature difference about 7~13$^{\circ}C$ in the nighttime and in the greenhouse with the heat pump and PCM latent heat storage system about 9~14$^{\circ}C$ in the nighttime.

  • PDF

Experimental Study on the Power Generation of a Thermoelectric Module with Temperature Difference and Load Resistance (온도차 및 부하 저항에 따른 열전모듈의 발전 특성 분석)

  • Lee, Kong-Hoon;Kim, Ook-Joong;Koh, Deuk-Yong
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.1942-1947
    • /
    • 2007
  • A thermoelectric module can be used for cooling or power generation. The basic requirements to achieve a significant thermoelectric performance are the same for both generators and coolers. Thermoelectric modules with $Bi_2Te_3$ materials are usually employed in the cooling applications below room temperature but it can also be used for the power generation in the similar temperature range. In the present study, the power generation with a $Bi_2Te_3$ thermoelectric module has been investigated. The temperature difference between the hot and cold sides of the module is maintained with electric heater and cold water from the circulating water bath. The result shows that the electric current generated increases with temperature difference and decreases with the load resistance. However, the voltage increases with both the temperature difference and load resistance. The electric power increases with temperature difference and it has the maximum value when the load resistance is about 4 ${\Omega}$ for a given device.

  • PDF

An Experimental Study on the Characteristics of Moxa Combustion in the Moxa Materials (재료(材料)에 따른 뜸의 연소(燃燒) 특성(特性)에 대한 연구(硏究))

  • Park, Young-Bae;Kang, Sung-Keel;Kim, Chang-Hwan;Koh, Hyung-Kyun;Oh, Hwan-Sup;Huh, Wung
    • The Journal of Korean Medicine
    • /
    • v.17 no.1 s.31
    • /
    • pp.222-233
    • /
    • 1996
  • In order to understand the stimulation quality of Artemisine Vulgaris Folium(Bong), Mori Ramulus(Sangi) and Persicae Ramulus(Dogi) combustion, and get the basic data for the development of electric moxibustion apparatus, the average temperature, peak temperature, average gradient temperature, maximum gradient temperature and combustion time of heating period on the three moxa materials were measured. 1. The average combustion temperature was high in order of Dogi, Sangi and Bong, and these were acknowledged to have a significant difference each other in the average temperature. 2. The peak combustion temperature among those was high in order of Dogi, Sangi and Bong, and Bong was acknowledged to have significant differences with Dogi and Sangi. Sangi and Dogi however were not acknowledged to have difference each other. 3. The average gradient temperature among those was high in order of Dogi, Sangi and Bong, and Bong was proved to have significant differences with Dogi and Sangi. Sangi and Dogi however were not proved to have difference each other. 4. The maximum temperature among those was high in order of Dogi, Sangi and Bong, bong was acknowledged to have signigicant differences with Dogi and Sangi, but Sangi and Dogi were not proved to have difference each other. 5. The combustion time was short in order of Dogi, Sangi and Bong. Bong was acknowledged to have significant differences with Dogi and Sangi, but Sangi and Dogi were not. In order to understand well the characteristics of combustion, it is required to have a quantitative interpretation of combustion calory, and, in the future, we expect it is required to have a consistent study for the clinical effectiveness and the mutual relationship according to the combustion characteristics.

  • PDF

A Study on Annealing of Fe-Si-B-Ni Amorphous Alloy (Fe-Si-B-Ni 비정질 합금의 어닐링에 관한 연구)

  • Kim, Shin-Woo;Song, Yong-Sul;Baek, Mu-Hum
    • Korean Journal of Materials Research
    • /
    • v.13 no.11
    • /
    • pp.721-724
    • /
    • 2003
  • A Fe-Si-B-Ni amorphous alloy manufactured by one roll melt-spinning method showed the crystallization temperature difference of a maximum $10^{\circ}C$ according to each lot. This temperature difference had a considerable influence on the annealing process to be conducted for obtaining the proper inductance of the alloy. The proper annealing temperature of the alloy was $480^{\circ}C$ and the annealing time increased as the crystallization temperature increased. The activation energy measured by Kissinger method increased as the crystallization temperature increased. Therefore, the annealing process must be adjusted by the crystallization temperature difference of the amorphous alloy.