• Title/Summary/Keyword: Maximum Heat Rate

Search Result 643, Processing Time 0.035 seconds

A Study on the Calculation of Heat Release Rate to Compensate the Error due to Single Zone Assumption in Diesel Engines (단일 영역 모델 열발생율 계산 방법의 개선에 관한 연구)

  • Kim Ki-Doo;Yoon Wook-Hyeon;Ha Ji-Soo;Ryu Seung-Hyup
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.7
    • /
    • pp.1063-1071
    • /
    • 2004
  • Accurate heat release analysis of cylinder pressure data is important for evaluating performance in the development of diesel engine However, traditional single zone first law heat release model(SZM) has significant limitations due to the simplified assumption of uniform charge and neglecting local temperature inside cylinder during combustion process. In this study. heat release rate based on single zone heat release model has been evaluated by comparison with computational analysis results using Fire code which is based on multi-dimensional model(MDM). To overcome limitations due to simplicity of single zone assumption. especially the influence of specific heat ratio on gross heat release has been esteemed and newly suggested were the equation $\gamma$= $\gamma$(${T/T}_{max}$) which describes the variations of gases thermodynamic properties with mean temperature and maximum mean temperature inside cylinder Single zone heat release model applied with this equation is shown to give very good results over whole range of operating conditions when compared with computational analysis results based on multi-dimensional model.

An Experimental Study on the Heat Dissipation Characteristics of the Natural Convection Type Radiator by using the PCMs (PCM물질을 적용한 자연대류형 방열기의 방열특성에 관한 실험적 연구)

  • Sung, Dae-Hoon;Kim, Min-Jun;Kim, Joung-Ha;Yun, Jae-Ho;Kim, Woo-Seung;Peck, Jong-Hyeon
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1155-1160
    • /
    • 2008
  • In the present study investigated the heat dissipation characteristics of the natural convection type radiator by using the latent heat from a solid-liquid PCM(Phase Change Material). Total radiator volume size is $423{\times}295{\times}83\;mm$ and PCM tank size is $398{\times}270{\times}26\;mm$. The objective was elapsed time lower than maximum operating temperature. Experimental condition, in order to study the effects of the phase-change phenomenon, carried out the various mass flow rate, input electric power, and heat of fusion temperature of two type PCMs. For the above experimental conditions, the cooling performance by using the latent heat showed that heat absorption rate performs for about 3 hours from using PCM $38^{\circ}C$. However, cooling performance by using PCM $50^{\circ}C$ showed higher than surface temperature of heater block because of heat of fusion.

  • PDF

Optimal design of a micro evaporator to maximize heat transfer coefficient (열전달 계수 최대화를 위한 마이크로 증발기의 최적 설계)

  • Sung, Tai-Jong;Oh, Dae-Sik;Seo, Tae-Won;Kim, Jong-Won
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2097-2101
    • /
    • 2007
  • This paper presents an optimal design of a micro evaporator which maximizes the heat transfer coefficient. Number of gaps, spanwise distance and streamwise distance are selected as the geometric design parameters. Mass flow rate of the refrigerant is selected as the non-geometric design parameter. Temperature at the surface of the heater is measured to valuate the heat transfer coefficient. Nine experiments are conducted using $L_9(3^4)$ orthogonal array. Maximum heat transfer coefficient is 640 W/$m^2K$ at the parameters of 2 gaps, 0.2 mm spanwise distance, 1.0 mm streamwise distance and 0.72 g/s mass flow rate. Among the 3 geometric parameters, the spanwise distance is the most sensitive parameter influencing the heat transfer coefficient. We conduct a second stage of experiment to increase the heat transfer coefficient by reselecting the mass flow rate. We concluded that 0.87 g/s is the optimized flow rate for an active micro cooler resulting in a heat transfer coefficient of 651 W/$m^2K$.

  • PDF

Influence of the Inclination Angle and Liquid Charge Ratio on the Condensation in Closed Two-Phase Thermosyphons with Axial Internal Low-Fins

  • Cho, Dong-Hyun;Han, Kyu-il
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.422-428
    • /
    • 2003
  • This study concerns the performance of the heat transfer of the thermosyphons having 60, 70, 80. 90 axial internal low-fins in which boiling and condensation occurr. Water, HCFC-141b and CFC-11 have been used as the working fluids. The operating temperature, the liquid charge ratio and the inclination angle of thermosyphons have been used as the experimental parameters. The heat flux and heat transfer coefficient at the condenser are estimated from experimental results. The experimental results have been assessed and compared with existing theories. As a result of the experimental investigation, it was found that the maximum heat flow rate in the thermosyphons is dependent upon the liquid charge ratio and inclination angle. A relatively high rate of heat transfer has been achieved by the thermosyphon with axial internal low-fins. The inclination of a thermosyphon has a notable influence on the condensation. In addition, the overall heat transfer coefficients and the characteristics at the operating temperature are obtained for the practical applications.

effect of Heating Rate on the Mechanical Properties in the Crystallization of $Li_2O$.$2SiO_2$ Glass ($Li_2O$.$2SiO_2$유리의 결정화에서 승온속도가 기계적 특성에 미치는 영향)

  • 최병현;고경현;안재환;지응업
    • Journal of the Korean Ceramic Society
    • /
    • v.33 no.7
    • /
    • pp.809-815
    • /
    • 1996
  • When Li2O.2SiO2 glass was crystallized between the temperature of maximum nucleation and the temperature of maximum crystal growth it was found that the control of heating rate had serious effect on the crystallinity and microstructure and the greatly changed physical properties. Density and elastic modulus tends to increase but thermal expansion coefficient decreased with increased crystallinity. When heating rate between the tempe-rature of maximum nucleation and the temperature of maximum crystal growth was 10~5$0^{\circ}C$/hr. crystallinity was increased to result in the increment of strength. When nuclation was done at 44$0^{\circ}C$ for 5 hours and the temperature of crystal growth was held at 575$^{\circ}C$ strength was increased until crystallinity reached 65% and strength was decreased with higher crystallinity. These phenomena could be explained that even for the same crystallinity different heat rates resulted in different number and size of cracks.

  • PDF

Characteristics of Absorption and Heat Transfer for Film Falling along a Vertical Inner Tube (3rd. Report, Refrigerating Capacity in Evaporator and Heating Capacity in Absorber) (수직관(수직관)내를 흘러내리는 액막식흡수기(液膜式吸收器)의 흡수(吸收) 및 열전달(熱傳達) 특성(特性) (제(第)3보(報), 증발기(蒸發器)의 냉동능력(冷凍能力)과 흡수기(吸收器)의 난방능력(暖房能力)))

  • Ohm, K.C.;Kashiwagi, Takao;Seo, J.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.3
    • /
    • pp.175-181
    • /
    • 1994
  • This paper deals with the correlation of absorption rate in absorber and evaporation rate in evaporator. The evaporator consists of a copper tube of 10mm dia, and 600mm long and chilled water flowing through the tube is fed by the chilled water circulator. The flowrate of LiBr-water solution in the absorber plays a significant role in determining the magnitude of the heat transfer rate from chilled water to refrigerant There exists a flowrate of solution which has a maximum value of heat transfer. It is interesting to note that the absorption rate of absorber increases with increasing the heat transfer rate of the evaporator. Also, absorption rate increases with evaportation rate, and the ratio(the former/the other) depends on the inlet temperature of LiBr-water solution in the absorber. The heating capacity in the absorber is higher than the refrigerating capacity in the evaporator.

  • PDF

Numerical Study of Interaction between Hydrogen and Hydrocarbon Flames (수소화염과 탄화수소화염의 상호작용에 관한 수치계산 연구)

  • Oh, Chang-Bo;Lee, Eui-Ju
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.2
    • /
    • pp.12-17
    • /
    • 2010
  • Numerical simulations were performed for the prediction of the flame structure during the interaction between hydrogen and hydrocarbon flames. A counterflow flow geometry was introduced to establish the interacting two flames. Methane was used as a representative hydrocarbon fuel in this study. A well-known numerical code for the counterflow flame, OPPDIF, was used for the simulations. The detailed chemistry was adopted to predict the flame structure reasonably. The interaction of two one-dimensional premixed flames established in counterflow burner was investigated with the global strain rate and velocity ratio. It was found that the maximum temperature located near the methane flame surface while the heat release rate of methane was lower than hydrogen flame. The flame thickness become narrow with increasing the velocity ratio while the global strain rate was fixed. The local strain rate and heat release rate at the methane flame surface were correlated with the global strain rate, while those at the hydrogen flame were not correlated with the global strain rate. However, the maximum temperature of the interacting flames was correlated with the global strain rate.

Study on the Establishment of Threshold Criteria for Heat Health Watch Warning System in Korea; Part I : Establishment of Criteria and Verification (고온건강경보시스템 기준 설정에 관한 연구( I ) - 기준 설정 및 검증 -)

  • Park, Jong-Kil;Jung, Woo-Sik;Kim, Eun-Byul
    • Journal of Environmental Science International
    • /
    • v.18 no.7
    • /
    • pp.767-780
    • /
    • 2009
  • This study investigates the standard, duration period and excess mortality of extreme heat using the standardized daily mortality data from 1991 to 2004, establishing a standard threshold Criteria for Heat Health Watch Warning System in Korea. It ultimately aims to provide the guidance in building up Heat Health Watch Warning System for Korea by suggesting the standard to quantify thermal stress from heat. The standard threshold Criteria for Heat Health Watch Warning System for Seoul metropolitan city takes into account both daily maximum temperature and daily maximum heat index(HI) and consists of four phases; caution, extreme caution, danger, and extreme danger. Extreme caution phase and danger phase are used as the advisory and warning of extreme heat, respectively. Since the nationwide distribution of the frequency of extreme heat day and the excess mortality rate shows little difference across regions, the standard threshold Criteria for Heat Health Watch Warning System for Seoul metropolitan city can be used for other regions.

TURBULENCE HEAT TRANSFER ENHANCEMENT TECHNIQUE FOR SQUARE DUCT WITH HIGH ASPECT RATIO (종횡비가 큰 사각 덕트내 난류 유동의 대류 열전달 증진 기술에 대한 연구)

  • Lee, Chan-Yong;Shin, Seung-Won;Chung, Ha-Seung;Park, Seung-Ho
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.305-307
    • /
    • 2010
  • In this study, we develop a method to achieve heat transfer enhancement inside a square duct with high aspect ratio without changing any inner structures. Especially, a method to lower the possible maximum temperature is suggested if constant heat flux is provided to single surface of square duct. Knowing the fact that heat transfer rate is inversely proportional to flow area, we proposed tapered channel concept which uses narrower gap toward the flow exit where the maximum temperature is expected. To maintain equivalent power consumption, inlet section has been enlarged. To verify the proposed concept, experimental tests have been performed.

  • PDF

Analysis of the Rankine Cycle Including Heat Exchange Processes (熱交換 過程을 考慮한 랜킨 사이클의 性能解析)

  • 정평석;노승탁
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.1
    • /
    • pp.150-156
    • /
    • 1986
  • A Rankine cycle including heat exchange processes in the steam generator has been analyzed by the concept of available energy. The operation condition of the cycle can be expressed with the evaporation temperature, and there exists an optimum power condition at which the thermal efficiency of the cycle is almost the same as that of the Carnot cycle at the maximum power condition. The mass flow rate of the working fluid increases sharply as the evaporation temperature approaches to the critical point, and the regenerative system is needed to operate the cycle at the maximum power condition.