• Title/Summary/Keyword: Maximum Force

Search Result 2,326, Processing Time 0.042 seconds

Thrust Force Estimation using Flexible Neural Networks

  • Kim, Myeong-Hee;Shigeyasu Kawaji;Masaki Arao
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.47.1-47
    • /
    • 2001
  • The drilling process has a great importance for the production technology due to its widerspread use in the manufacturing industry. In order to enhance a maximum production rate and prevent the drill from the damage, it is important to monitor and control the drilling system. Thrust force and cutting torque are the main output variables in the design of drilling control systems. In this paper, an alternative estimation method of thrust force by using flexible neural networks is proposed. Flexible neural network uses the sigmoid activation function with adjustable parameter in order to enhance the approximation accuracy ...

  • PDF

Evaluation of Uplift Force Acting on Foundation of Underground Structure (지하구조물 하부에 작용하는 양압력 평가)

  • Kim, Jin-Man;Han, Heui-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.662-671
    • /
    • 2020
  • The uplift force acts directly on the foundation and causes a building to float to the upper ground. To examine the stability of a structure according to the uplift force, four sites (Paju, Anyang, Osan, and Gangneung) were selected, and sensors were installed on the foundations for the field tests. The rainfall characteristics were analyzed around June~September, and the changes in the water level of the adjacent river were considered. The maximum uplift force except for Gangneung did not exceed 72% of the water pressure when the groundwater level was up to the surface. On the other hand, the maximum uplift force in Osan was approximately 67%, but the reliability was slightly inferior because the difference from the average (46%) was large. The minimum uplift force was within 10% except for Anyang (~ 41%). At the Gangneung site on soft rock where the permanent drainage facility was installed before the measurement, the maximum and minimum uplift force was approximately 14% and 3.5%, respectively. Based on the measurement results, the possibility of overdesigning or underdesigning comes from the design by the hydrostatic pressure when the groundwater level is up to the surface.

The Jerking Force by Hooked Carp and its Periodicity with the Tail Beat (낚시에 물린 잉어가 미치는 힘과 꼬리 진동에 의한 주기성)

  • KO Kwan-Soh;KIM Yong-Hae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.15 no.3
    • /
    • pp.226-232
    • /
    • 1982
  • The measurements of the jerking force and the tail beat by hooked carp were carried out using a strain gauge at a fish pond from July to August 1981. The maximum jerking force was sustained for a while in the initial state after a carp was hooked, but the jerking force was gradually decreased as a function of the time elapsed until the fish was utterly exhausted, and it converged to the body weight at last. The results are as follows : 1. The maximum jerking force $F_m(g)$ can be expressed with empirical formula : $$F_m=3.23W+105$$ where W (g) is the body weight. 2. Dynamic change of the maximum jerking force $F_n(g)$ by one tail beat with time $t_{n}(-10T/2{\leq}\;t_n{\leq}10T/2)$ can he induced with the equation as follows : $$F_n=(0.27W-6.52)(|t_n|+C)^{-2.10}$$ where the period T (sec) is given by the following equation with the body weight : T=0.000385W+0.193 3. The jerking force at each of the peak points $F_p$ (g) varies with the time elapsed t (sec) as following equation : $$F_{p}=(2.23W+105)e^{-{\beta}t}+W$$. The value of durability index $\beta$ was nearly zero in the initial state and about 1.7 in the exhausted state at last. 4. It was clearly shown that the change of jerking force by hooked carp was closely related to the tail beat from a paired difference T-test.

  • PDF

Occlusal Analysis in the Policemen with Temporomandibular Disorders Using T-scan II System (경찰 종사자의 측두하악장애환자에서 T-scan II System을 이용한 교합분석)

  • Lim, Hyun-Dae;Jung, Seung-Ah;Lee, You-Mee
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.4
    • /
    • pp.365-373
    • /
    • 2006
  • This study suggested correction of excessive mouth opening or maximum occlusal contact to analyse occlusal contact time, occlusal contact number and force through evaluation of occlusal pattern in policemen with temporomandibular disorders. The community of policemen influence on temporomandibular disorder's development and progress due to other condition of mouth opening and maximal occlusal contact. Repeated training or changes of usual life style may cause imbalance of stomatognathic system including the masticatory muscle, then develop or aggravate pain of temporomandibular joints and associated structures. This study uses T-scan II system(Tekscan Co., USA) for evaluation on occlusal pattern may influence temporomandibular disorders, and then the subjects take a sensor at 20 mm opening for maximal occlusal contact force. The policemen with temporomandibualr disorders get more long time on maximum contact timing, more short on end contact timing, and more force on end contact force than general society's. So they get closure of mouth with more short time and more force, then transfer remaining load to temporomandibular joint. There are no statistically significances between affected side and occlusal pattern of occlusal contact time and force. There are Left -right dental arch imbalances seems on Rt. dental arch if affected side is right and Lt. dental arch if affected side is left. In above results, It's worth due consideration that policemen with temporomandibular disorders get more smooth mandibualr movement and less force on maximal occlusal contact position.

The Static Equivalent Radial Load under the Moment and Radial Force for the Deep Groove Ball Bearings (모멘트 하중을 고려한 깊은 홈 볼 베어링의 정등가 하중에 관한 연구)

  • 이재선;한동철
    • Tribology and Lubricants
    • /
    • v.14 no.3
    • /
    • pp.94-99
    • /
    • 1998
  • Generally not only the radial load but also the moment may be applied to the ball bearings for a shaft system. However it has been difficult to determine the static equivalent load because there is the radial static equivalent equation only for the axial and radial force on the bearings. In this paper, the same static equivalent radial load which makes the maximum contact force at the interface between the ball and groove as the applied radial force and moment generate is calculated under the condition that the radial force and the moment are applied to the bearings simultaneously. The relation between the static equivalent load and applied force is studied. Therefore the simple and effective equation for the static equivalent radial load of the radial load and moment is proposed for the deep groove ball bearings.

Normalized Contact Force to Minimize "Electrode-Lead" Resistance in a Nanodevice

  • Lee, Seung-Hoon;Bae, Jun;Lee, Seung Woo;Jang, Jae-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.8
    • /
    • pp.2415-2418
    • /
    • 2014
  • In this report, the contact resistance between "electrode" and "lead" is investigated for reasonable measurements of samples' resistance in a polypyrrole (PPy) nanowire device. The sample's resistance, including "electrode-lead" contact resistance, shows a decrease as force applied to the interface increases. Moreover, the sample's resistance becomes reasonably similar to, or lower than, values calculated by resistivity of PPy reported in previous studies. The decrease of electrode-lead contact resistance by increasing the applying force was analyzed by using Holm theory: the general equation of relation between contact resistance ($R_H$) of two-metal thin films and contact force ($R_H{\propto}1/\sqrt{F}$). The present investigation can guide a reliable way to minimize electrode-lead contact resistance for reasonable characterization of nanomaterials in a microelectrode device; 80% of the maximum applying force to the junction without deformation of the apparatus shows reasonable values without experimental error.

Active Control of Vibrational Intensity at a Reference Point in an Infinite, Elastic Plate (무한 탄성 평판상의 기준점에 전달되는 진동인텐시티의 능동제어)

  • 김기만
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.11 no.4
    • /
    • pp.22-30
    • /
    • 2001
  • In this paper, active control of vibrational intensity at a reference point in an infinite, elastic plate was discussed. The plate is excised harmonically by a vibrating source, which has a vertical point force. The optimal condition of controller was investigated to minimize the vibrational intensity being transmitted from the vibrating source to a reference point. Hence the method of feedforward control was employed for the control strategy and then the cost function was evaluated to find the optimal control force. Three types of control force (Vertical force, Moment, and Coupling force (a set of vertical force and moment) ) and controller's positions were examined to define the optimal condition of the controller. The vibrational intensity at a reference point was found to be reduced down to a zero level, compared with the uncontrolled case. Especially maximum reduction of vibrational intensity was achieved when the controller was collinearly positioned between a vibrating source and a reference point.

  • PDF

A Clinical Consideration of Orthodontic Force (교정력에 관한 임상적인 소고)

  • Kim, Il-Bong;Ku, Ok-Kyung;Sung, Jae-Hyun;Kim, Yung-Soo
    • The Journal of the Korean dental association
    • /
    • v.11 no.2
    • /
    • pp.123-129
    • /
    • 1973
  • The authors measured orthodontic force using the orthodontic materials of the Rocky Mountain Products Company. The results were as follows : ① Use latex of wide diameter in long distance, and when the latex of wide diameter activated by four or five times, we obtained a optimal force. ② The authors obtained canine retractions with sectional arch. Activation of sectional arch began at 1mm and had to do not activations of 3mm more. ③ The leveling started from .014 green round wire and finished to. 0.16" green Elgiloy round wire. Permit only a mild force in ideal arch form, in rectangular wire. ④ Fundamentaly, elastic thread obtained maximum force by activating as two times. ⑤ Coil spring obtained more heavy force from short distance than long distance.

  • PDF

A Mechanism Design of the 3-axial Road Simulator Linkage (3축 로드 시뮬레이터 링크부의 메카니즘 설계)

  • 정상화;류신호;김종태;이규태;장완식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.2
    • /
    • pp.140-147
    • /
    • 2003
  • Full scale durability test in the laboratory is an essential of any fatigue life evaluation of components or structures of the automotive vehicle. Component testing is particularly important in today's highly competitive industries where the design to reduce weight and production costs must be balanced with the necessity to avoid expensive service failure. Generally, hydraulic road simulator is used to carry out the fatigue test and the vibration test. In this paper, the link unit which is able to realize the 3 element forces such as vertical force, lateral force, and longitudinal force that are applied to the road simulator is designed. Also, the designed link is verified with kinematics and inverse-kinematics. From this results, the designed factor satisfied the maximum stroke so that it satisfied the requirements for 3-axial road simulator.

An Experimental Study on the Impact Force of a Mechanical Heart Valve Prostheses (기계식 심장판막의 충격력에 관한 실험적 연구)

  • Lee, J.H.;Cheon, G.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.167-171
    • /
    • 1996
  • Impact force and strains induced by impact between the occluder and the struts have been measured with force senfor and strain gages. The maximum reaction force was about 25N, and the calculated impact force on the root of the struts amount about $9{\sim}17N$. Impact force on the inlet strut is greater than that of the outlet strut, but the strain on the outlet strut is much higher than that of the inlet strut. These values might cause severe damage on the valve in the critical cases. The results of this study may be extended for the analysis of the endurance limit and optimal design of the struts and occluder.

  • PDF