• Title/Summary/Keyword: Maximum Dose

Search Result 1,208, Processing Time 0.031 seconds

Application of Thermoluminescence to Detecting Post-Irradiation of Onion and Garlic (열발광기를 이용한 양파와 마늘의 방사선 조사 여부 검지)

  • ;;Ute Wagner;Georg A. Schreiber
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.27 no.1
    • /
    • pp.63-68
    • /
    • 1998
  • Irradiation can be utilized to inhibit sprouting of onions and garlic. Thermoluminescence(TL) is a potential method to detect post-irradiation of onions and garlic because they are irradiated with soil or dusts on them, from which minerals can be isolated for TL analysis. This study was to determine whether TL can be applied for the detection of post-irradiation of onions and garlic. Onions and garlic produced in Korea were irradiated in the range of 0.01~0.6kGy. Minerals isolated from the samples using sodium polytrungstate solution were used for TL analysis. The onions and garlic irradiated at 0.15kGy or higher could be detected with little errors. Minimum dose for the 2nd glow could be applied since the dose for the 2nd glow did not affect the results. The TL intensities of the temperature ranges of 229~295$^{\circ}C$ and 229~361$^{\circ}C$ and the maximum intensity provided more accurate information for the determination of the post-irradiation of onions and garlic.

  • PDF

Antitumor Effects of Glycoportein Extracted from Sea Cucumber (Stichopus japonicus)

  • Moon, Jeung-Hye;Ryu, Hong-Sool;Suh, Jae-Soo
    • Preventive Nutrition and Food Science
    • /
    • v.4 no.2
    • /
    • pp.117-121
    • /
    • 1999
  • The anititumor and immunologic activities of the glycoproteins extracted from sea cucumber (Stichopus japonicus) on mice bearing sarcoma 180 cells were investigated . Maximum tumor suppression (64%) occurred at the dose of 100mg glycoprotein/kg. The highest prolongation ratio was achieved at the level of 100mg/kg an dincreased by 395 more than that of control. Glycoproteins from sea cucumber exhibited direct cytotoxic effect on the tumor cells. Dose dependent increase of leucocyte, peritoneal exudate cell and weights of immunoorgans revealed the improvement of immunity. When the glycoportein-administered group was compared with the control, a significant difference was not noted in the clinico-chemical values such as S-GOT, S-GPT , alkaline phoshatse activity, total protein, cholesterol, triglyceride, urea nitrogen and glucose levels in blood. These results suggests that the antitumor activity of sea cucumber glycoprotein is associated with activation of cells in the immune system.

  • PDF

Implementation of Fire Risk Estimation System for various Fire Situations using Multiple Sensors (다중 센서들을 이용한 다양한 화재 상황의 위험도 추정 시스템 개발)

  • Lee, Kwangjae;Lee, Youn-Sung
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.394-398
    • /
    • 2016
  • In this paper, a fire detection system based on quantitative risk estimation is presented. Multiple sensors are used to build a comprehensive indicator that represents the risk of fire quantitatively. The proposed fire risk estimation method consists of two stages which determines the occurrence of fire and estimates the toxicity of the surveillance area. In the first stage, fire is reliably detected under diverse fire scenarios. The risk of fire is estimated in the second stage. Applying Purser's Fractional Effective Dose (FED) model which quantitates harmfulness of toxic gases, the risk of the surveillance area and evacuation time are calculated. A fire experiment conducted using four different types of combustion materials for the verification of the system resulted in a maximum error rate of 12.5%. By using FED calculation and risk estimation methods, the proposed system can detect various signs of fire faster than conventional systems.

Changes in physicochemical characteristics of cation exchange resins by high dose gamma irradiation

  • Seung Joo Lim;Wang Kyu Choi;Mansoo Choi
    • Nuclear Engineering and Technology
    • /
    • v.56 no.5
    • /
    • pp.1777-1780
    • /
    • 2024
  • Chemical and thermal characteristics of cation exchange resins were examined after irradiation of gamma rays. The degradation of cation exchange resins was mainly observed at doses of up to 500 kGy, whereas the balance between degradation and cross-linking reactions was sustained at 700 kGy. While the carbon content decreased significantly up to a maximum dose of 500 kGy, it showed an increase at higher doses. Conversely, the oxygen content exhibited a decrease in contrast to the carbon content. The continuous reduction in sulfur content was attributed to the decomposition of sulfonic groups. Gamma-ray irradiation caused a decrease in the initiation temperature of sulfonic groups and PS-DVB, but unlike the chemical properties of cation exchange resins due to gamma-ray irradiation, the thermal properties of resins remained unaffected.

Late Rectal Complication in Patients treated with High Dose Rate Brachytherapy for Stage IIB Carcinoma of the Cervix (FIGO병기 IIB 자궁경부암에서 고선량 강내 방사선치료후의 후기 직장 합병증)

  • Chung, Eun-Ji;Kim, Gwi-Eon;Suh, Chang-Ok;Keum, Ki-Chang;Kim, Woo-Cheol
    • Radiation Oncology Journal
    • /
    • v.14 no.1
    • /
    • pp.41-52
    • /
    • 1996
  • Purpose : This paper reports a dosimetric study of 88 patients treated with a combination of external radiotherapy and high dose rate ICR for FIGO stage IIB carcinoma of the cervix. The purpose is to investigate the correlation between the radiation doses to the rectum, external radiation dose to the whole pelvis, ICR reference volume, TDF BED and the incidence of late rectal complications, retrospectively. Materials and Methods : From November 1989 through December 1992, 88 patients with stage IIB cervical carcinoma received radical radiotherapy at Department of Radiation Oncology in Yonsei University Hospital. Radiotherapy consisted of 44-54 Gy(median 49 Gy) external beam irradiation plus high dose rate intracavitary brachytherapy with 5 Gy per fraction twice a week to a total dose of 30 Gy on point A. The maximum dose to the rectum by contrast(r, R) and reference rectal dose by ICRU 38(dr, DR) were calculated. The ICR reference volume was calculated by Gamma Dot 3.11 HDR planning system, retrospectively The time-dose factor(TDF) and the biologically effective dose (BED) were calculated. Results : Twenty seven($30.7\%$) of the 88 patients developed late rectal complications:12 patients($13.6\%$) for grade 1, 12 patients($13.6\%$) for grade 2 and 3 patients($3.4\%$) for grade 3. We found a significant correlation between the external whole pelvis irradiation dose and grade 2, 3 rectal complication. The mean dose to the whole pelvis for the group of patients with grade 2, 3 complication was Higher, $4093.3\pm453.1$ cGy, than that for the patients without complication, $3873.8\pm415.6$ (0.05$7163.0\pm838.5$ cGy, than that for the Patients without rectal complication, $0772.7\pm884.0$ (p<0.05). There was no correlation of the rate of grade 2, 3 rectal complication with the iCR rectal doses(r, dr), ICR reference volume, TDF and BED. Conclusion : This investigation has revealed a significant correlation between the dose calculated at the rectal dose by ICRU 38(DR) or the most anterior rectal dose by contrast(R) dose to the whole pelvis and the incidence of grade 2, 3 late rectal complications in patients with stage IIB cervical cancer undergoing external beam radiotherapy and HOR ICR. Thus these rectal reference points doses and whole pelvis dose appear to be useful Prognostic indicators of late rectal complication in high dose rate ICR treatment in cervical carcinoma.

  • PDF

Adjuvant Radiotherapy after Breast Conserving Treatment for Breast Cancer:A Dosimetric Comparison between Volumetric Modulated Arc Therapy and Intensity Modulated Radiotherapy

  • Liu, Zhe-Ming;Ge, Xiao-Lin;Chen, Jia-Yan;Wang, Pei-Pei;Zhang, Chi;Yang, Xi;Zhu, Hong-Cheng;Liu, Jia;Qin, Qin;Xu, Li-Ping;Lu, Jing;Zhan, Liang-Liang;Cheng, Hong-Yan;Sun, Xin-Chen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.8
    • /
    • pp.3257-3265
    • /
    • 2015
  • Background: Radiotherapy is an important treatment of choice for breast cancer patients after breast-conserving surgery, and we compare the feasibility of using dual arc volumetric modulated arc therapy (VMAT2), single arc volumetric modulated arc therapy (VMAT1) and Multi-beam Intensity Modulated Radiotherapy (M-IMRT) on patients after breast-conserving surgery. Materials and Methods: Thirty patients with breast cancer (half right-sided and half left-sided) treated by conservative lumpectomy and requiring whole breast radiotherapy with tumor bed boost were planned with three different radiotherapy techniques: 1) VMAT1; 2) VMAT2; 3) M-IMRT. The distributions for the planning target volume (PTV) and organs at risk (OARs) were compared. Dosimetries for all the techniques were compared. Results: All three techniques satisfied the dose constraint well. VMAT2 showed no obvious difference in the homogeneity index (HI) and conformity index (CI) of the PTV with respect to M-IMRT and VMAT1. VMAT2 clearly improved the treatment efficiency and can also decrease the mean dose and V5Gy of the contralateral lung. The mean dose and maximum dose of the spinal cord and contralateral breast were lower for VMAT2 than the other two techniques. The very low dose distribution (V1Gy) of the contralateral breast also showed great reduction in VMAT2 compared with the other two techniques. For the ipsilateral lung of right-sided breast cancer, the mean dose was decreased significantly in VMAT2 compared with VMAT1 and M-IMRT. The V20Gy and V30Gy of the ipsilateral lung of the left-sided breast cancer for VMAT2 showed obvious reduction compared with the other two techniques. The heart statistics of VMAT2 also decreased considerably compared to VMAT1 and M-IMRT. Conclusions: Compared to the other two techniques, the dual arc volumetric modulated arc therapy technique reduced radiation dose exposure to the organs at risk and maintained a reasonable target dose distribution.

A Comparison of the Independent Verification Methods for the Results of Leksell GammaPlan for Gamma Knife Predecessor with the Hemispherical Collimators (반구형 시준기를 가진 감마나이프에 대한 렉셀감마플랜 결과물의 독립적인 검증방법들의 비교)

  • Hur, Beong Ik
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.7
    • /
    • pp.521-529
    • /
    • 2016
  • Since Gamma Knife(R) radiosurgery(GKRS) is based on a single-fraction high dose treatment strategy, independent verification for the results of Leksell GammaPlan(R) (LGP) is an important procedure in assuring patient safety and minimizing the risk of treatment errors. Several verification methods have been developed and reported previously. Thus these methods were tested statistically and tried on Leksell Gamma Knife(LGK) target treatments through the embodiment of the previously proposed algorithms(PPA). The purpose of this study was to apply and evaluate the accuracy of verification methods for LGK target treatments using PPA. In the study 10 patients with intracranial lesion treated by GKRS were included. We compared the data from PPA and LGP in terms of maximum dose, arbitrary point dose, and treatment time at the isocenter locations. All data were analyzed by Paired t-test, which is statistical method used to compare two different measurement techniques. No statistical significance in maximal dose at 10 cases was observed between PPA and LGP. Differences in average maximal dose ranged from -0.53 Gy to 3.71 Gy. The arbitrary point dose calculated by PPA and LGP was not statistically significant too. But we found out the statistical difference with p=0.021 between TMR and LGP for treatment time at the isocenter locations. PPA can be incorporated as part of a routine quality assurance(QA) procedure to minimize the chance of a wrong overdose. Statistical analyses demonstrated that PPA was in excellent agreement with LGP when considering the maximal dose and the arbitrary point dose for the best plan of GKRS. Due to the easy applicability we hope PPA can be widely used.

Subacute Toxicity of cis-Malonato[(4R,5R)-4,5-bis(aminomethyl)-2-isopropyl-1,3-dioxolane]platinum(II)(SKI 2053R) in rats (랫드에서 cis-Malonato[(4R,5R)-4,5-bis(aminomethyl)-2-isopropyl-1,3-dioxolane]platinum(II)(SKI 2053R)의 아급성독성시험에 관한 연구)

  • Kim, Hyoung-Ook;Kang, Kyung-Sun;Shin, Dong-Jin;Cho, Jae-Jin;Kim, Bae-Hwan;Seo, Kwang-Won;Nam, Ki-Hoan;Lee, Yong-Soon
    • Toxicological Research
    • /
    • v.8 no.2
    • /
    • pp.217-233
    • /
    • 1992
  • This study was performed to determine the toxic effects of graded dose levels of SKI 2053R after repeated administration. Three groups of Sprague-Dawley rats(10M and 10F per group) were given a total of 25 i.v. injections of SKI 2053R (1.50,3.75,9.38mg/kg/day). In order to compare the toxic effects of SKI 2053R with those of cisplatin, one group of Sprague-Dawley rats (10M and 10F per group) were given a total of 25 i.v.injections of cisplatin (1.70mg/kg/day). The dosing schedule was divided into five courses of 5 consecutive days with 16-day dose-free intervals between each course. No drug-related toxicity occurred in low dose level group (1.50mg/kg/day) of SKI2053R. From the results of hematological examination, peripheral WBC counts, RBC counts and hemoglobin of high dose level group(9.38mg/kg/day)of SKI 2053R were significantly lower than those of no-treated group. Other toxicities including reduced final body weight, proteinuria and hematuria were observed in high dose level group of SKI 2053R. But, no change was detected in serum biochemical values of SKI 2053R treated groups. All of the rats in cisplatin treated group were died between 3 and 13 weeks, while rats treated with SKI2053R survived to the end except one rat of middle dose level group(3.75mg/kg/day). In histopathological examinations, rats that received cisplatin manifested severe tubular damage in kidney and hemosiderosis in spleen, but no critical pathological lesion was observed in rats of other groups. Considering the results of this study, it was concluded that non-toxic dose of SKI 2053R in this treatment schedule was estimated to be 3.75 mg/kg/day and the maximum tolerated dose was to be higher than 9.38mg/kg/day. The toxic profiles fo SKI 2053R were different from those of cisplatin, and its toxicity was considerably lower than that of cisplatin.

  • PDF

Development and utility evaluation of new Multi-Leaf Collimator for Diagnostic X-ray Equipment

  • Ji, Hoon;Han, Su Chul;Baek, Jong Hyeun;Lee, Dong Hoon;Park, Seungwoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.936-942
    • /
    • 2018
  • The diagnostic multi-leaf collimator preventing unnecessary dose from entering into patients during the diagnostic examination was made in this study. The movement of the entire 50 leaves was embodied with the group of 25 ones thereof configured in a pair facing each other on the left and right of the median line. Dimensions of the length, width, and height of each shielding leaf were $5{\times}0.5{\times}0.5cm^3$ resulting in the maximum boost field of $10{\times}10cm^2$. The material of multi-leaf collimator had the excellence on the machinability with the use of the SKD-11 alloy tool steel having the high wear resistance against frequent movement, and it was devised to control both-side's shielding leaves by moving 2 motors unlike existing remedial multi-leaf collimator that use as many motors as the number of 50 shielding leaves. Thereafter, the transmission dose of leaves, cross-leaf leakage dose, and inter-leaf leakage dose were measured by the developed multi-leaf collimator attached to X-ray equipment. An ionization chamber was used to detect doses there from, and the comparative analysis was carried out by means of the radiographic film that was easy to detect the dose leakage in between each leaf. Results obtained from the test conducted in comparative analysis yielded approximately 98%, 96%, and 94% of shielding efficiency realized at each level of energy of 80kV, 100kV, and 120kV it was confirmed there was no dose leakage resulted from the varied level of irradiation energy. Thus the multi-leaf collimator to be developed based on this study is thought that it could fully reduce the unnecessary dose to patients in the diagnostic test and the shielding efficiency thereof is expected to be increasing if it is made in a miniaturized form with a way of increasing the thickness of each leaf later for an extended application to general diagnostic purposes.

A Comparative Analysis of Exposure Doses between the Radiation Workers in Dental and General Hospital (일반병원과 치과병원과의 방사선 관계종사자 피폭선량 비교분석)

  • Yang, Nam-Hee;Chung, Woon-Kwan;Dong, Kyung-Rae;Choi, Eun-Jin;Ju, Yong-Jin;Song, Ha-jin
    • Journal of Radiation Industry
    • /
    • v.9 no.1
    • /
    • pp.47-55
    • /
    • 2015
  • Research and investigation is required for the exposure dose of radiation workers to work in the dental hospital as increasing interest in exposure dose of the dental hospital recently accordingly, study aim to minimize radiation exposure by making a follow-up study of individual exposure doses of radiation workers, analyzing the status on individual radiation exposure management, prediction the radiation disability risk levels by radiation, and alerting the workers to the danger of radiation exposure. Especially given the changes in the dental hospital radiation safety awareness conducted the study in order to minimize radiation exposure. This study performed analyses by a comparison between general and dental hospital, comparing each occupation, with the 116,220 exposure dose data by quarter and year of 5,811 subjects at general and dental hospital across South Korea from January 1, 2008 through December 31, 2012. The following are the results obtained by analyzing average values year and quarter. In term of hospital, average doses were significantly higer in general hospitals than detal ones. In terms of job, average doses were higher in radiological technologists the other workes. Especially, they showed statistically significant differences between radiological technologists than dentists. The above-mentioned results indicate that radiation workers were exposed to radiation for the past 5 years to the extent not exceeding the dose limit (maximum $50mSv\;y^{-1}$). The limitation of this study is that radiation workers before 2008 were excluded from the study. Objective evaluation standards did not apply to the work circumstance or condition of each hospital. Therefore, it is deemed necessary to work out analysis criteria that will be used as objective evaluation standard. It will be necessary to study radiation exposure in more precise ways on the basis of objective analysis standard in the furture. Should try to minimize the radiation individual dose of radiation workers.