• Title/Summary/Keyword: Maximum Degree

Search Result 1,640, Processing Time 0.041 seconds

Development of a Thermoplastic Oral Compensator for Improving Dose Uniformity in Radiation Therapy for Head and Neck Cancer (두경부암 방사선치료 시 선량 균일도 향상을 위한 Thermoplastic 구강 보상체의 개발)

  • Choi, Joon-Yong;Won, Young-Jin;Park, Ji-Yeon;Kim, Jong-Won;Moon, Bong-Ki;Yoon, Hyong-Geun;Moon, Soo-Ho;Jeon, Jong-Byeong;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.269-278
    • /
    • 2012
  • Aquaplast Thermoplastic (AT) is a tissue-equivalent oral compensator that has been developed to improve dose uniformity at the common boundary and around the treated area during radiotherapy in patients with head and neck cancer. In order to assess the usefulness of AT, the degree of improvement in dose distribution and physical properties were compared to those of oral compensators made using paraffin, alginate, and putty, which are materials conventionally used in dental imprinting. To assess the physical properties, strength evaluations (compression and drop evaluations) and natural deformation evaluations (volume change over time) were performed; a Gafchromic EBT2 film and a glass dosimeter inserted into a developed phantom for dose verification were used to measure the common boundary dose and the beam profile to assess the dose delivery. When the natural deformation of the oral compensators was assessed over a two-month period, alginate exhibited a maximum of 80% change in volume from moisture evaporation, while the remaining tissue-equivalent properties, including those of AT, showed a change in volume that was less than 3%. In a free-fall test at a height of 1.5 m (repeated 5 times as a strength evaluation), paraffin was easily damaged by the impact, but AT exhibited no damage from the fall. In compressive strength testing, AT was not destroyed even at 8 times the force needed for paraffin. In dose verification using a glass dosimeter, the results showed that in a single test, the tissue-equivalent (about 80 Hounsfield Units [HU]) AT delivered about 4.9% lower surface dose in terms of delivery of an output coefficient (monitor unit), which was 4% lower than putty and exhibited a value of about 1,000 HU or higher during a dose delivery of the same formulation. In addition, when the incident direction of the beam was used as a reference, the uniformity of the dose, as assessed from the beam profile at the boundary after passing through the oral compensators, was 11.41, 3.98, and 4.30 for air, AT, and putty, respectively. The AT oral compensator had a higher strength and lower probability of material transformation than the oral compensators conventionally used as a tissue-equivalent material, and a uniform dose distribution was successfully formed at the boundary and surrounding area including the mouth. It was also possible to deliver a uniformly formulated dose and reduce the skin dose delivery.

ABRASION AND CHEMICAL DEGRADATION OF LIGHT-CURED COMPOSITE RESIN FOR UPDATED RESIN DEVELOPMENT (차세대 레진개발을 위한 광중합형 복합레진의 마모와 화학적 분해)

  • Yang, Kyu-Ho;Choi, Nam-Ki;Yook, Geun-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.685-695
    • /
    • 2004
  • The aim of this study was to evaluate the resistance to degradation and to compare the wear resistance characteristics of four composite resins in an alkaline solution. The resistance to degradation was evaluated on the basis of mass loss(%), degradation depth(${\mu}m$), Si loss(ppm) and wear depth. The brands studied were Heliomolar flow, Filtek supreme, Point4, Tetric flow. The results were as follows: 1. The sequence of the mass loss was in descending order by Heliomolar flow, Filtek supreme, Point4, Tetric flow. There was significant differences among the materials except Heliomolar flow and Filtek supreme. 2. The sequence of the degree of degradation layer depth was in descending order by Filtek supreme, Heliomolar flow, Tetric flow, Point4. There were significant differences among the materials except Heliomolar flow and Tetric flow. 3. The sequence of Si loss was in descending order by Filtek supreme, Heliomolar flow, Point4, Tetric flow. There were significant differences among the materials except Point 4 and Tetric flow. 4. The sequence of maximum wear depth was in descending order by Heliomolar flow, Point4, Fillet supreme, Tetric flow and there was increasing wear depth on soaking in 0.1N NaOH solution. 5. When observed with SEM, destruction of bonding between matrix and filler was observed and when observed with CLSM, the depth of degradation layer of specimen surface was observed. There results indicate that wear and hydrolytic degradation could be considered to be evaluation factors of composite resins.

  • PDF

The Distribution and Geomorphic Changes of Natural Lakes in East Coast Korea (한반도 동해안의 자연호 분포와 지형 환경 변화)

  • Lee, Min-Boo;Kim, Nam-Shin;Lee, Gwang-Ryul
    • Journal of the Korean association of regional geographers
    • /
    • v.12 no.4
    • /
    • pp.449-460
    • /
    • 2006
  • This study aims to analyze distribution of natural lakes including lagoonal lake(lagoon) and tributary dammed lake(tributary lake) and calculate the size, morphology in order to interpret time-serial change of lakes using methodology of remote sensing images(1990s), GIS and topographic maps(1920s) in east coast of Korean Peninsular. Analysis results show that in 1990s, there are 57 natural lakes, with the total size of $75.62km^2$ over size $0.01km^2$. marine-origin lagoons are 48 with total size of $64.85km^2$, composing 85% of total natural lake, and the largest lagoon is Beonpo in Raseon City. Tributary lakes have been formed by damming of tributary channels by fluvial sand bars from main stream, located nearby at coastal zone, similar to lagoon sites. Large tributary lake, Jangyeonho, is developed in lava plateau dissection valley of Eorang Gun, Hamnam Province. There are more distributed at Duman River mouth$\sim$Cheongjin City, Heungnam City$\sim$Hodo Peninsular and Anbyeon Gun$\sim$Gangreung City. Geomorphometrically, correlation of size to circumference is very high, but correlation of size to shape irregularity is very low. The direction of lagoonal coast, NW-SE and NE-SW are predominated due to direction of tectonic structure and longshore currents. The length of the river into lake are generally short, maximum under 15km, and lake size is smaller, degree of size decreasing is higher. Geomorphic patterns of the lake location are classified as coast-hill range, coastal plain, coastal plain-channel valley, coastal plain-hill range and channel valley-hill range. During from 1920s to 1990s, change with lake size decreasing is highest at coastal plain-channel valley, next is coastal plain. Causes of the size decreasing are fluvial deposition from upper rivers and human impacts such as reclamation.

  • PDF

Persistence of Fungicide Pencycuron in Soils (토양 중 살균제 Pencycuron의 잔류 특성)

  • An, Xue-Hua;An, Wen-Hao;Im, Il-Bin;Lee, Sang-Bok;Kang, Jong-Gook
    • The Korean Journal of Pesticide Science
    • /
    • v.10 no.4
    • /
    • pp.296-305
    • /
    • 2006
  • The adsorption and persistence of pencycuron {1-(4-chlorobenzyl) cyclopentyl-3-phenylurea} in soils were investigated under laboratory and field conditions to in order to assess the safety use and environmental impact. In the adsorption rate experiments, a significant power function of relation was found between the adsorbed amount of pencycuron and the shaking time. Within one hour following the shaking, the adsorption amounts in the SCL and the SiCL were 60 and 65% of the maximum adsorption amounts, respectively. The adsorption reached a quasi-equilibrium 12 hours after shaking. The adsorption isotherms followed the Freundlich equation. The coefficient (1/n) indicating adsorption strength and degree of nonlinearity was 1.45 for SCL and 1.68 to SiCL. The adsorption coefficients ($K_d$) were 2.31 for SCL and 2.92 to SiCL, and the organic carbon partition coefficient, $K_{oc}$, was 292.9 in SCL and 200.5 inSiCL. In the laboratory study, the degradation rate of pencycuron in soils followed a first-order kinetic model. The degradation rate was greatly affected by soil temperature. As soil incubation temperature was increased from 12 to $28^{\circ}C$, the residual half life was decreased from 95 to 20 days. Arrhenius activation energy was 57.8 kJ $mol^{-1}$. Furthermore, the soil moisture content affected the degradation rate. The half life in soil with 30 to 70% of field moisture capacity was ranged from 21 to 38 days. The moisture dependence coefficient, B value in the empirical equation was 0.65. In field experiments, the half-life were 26 and 23 days, respectively. The duration for period of 90% degradation was 57 days. The difference between SCL and SiCL soils varied to pencycuron degradation rates were very limited, particularly under the field conditions, even though the characteristics of both soils are varied.

A Study on Facilities Damage Characteristics Caused by Forest Fire in Goseong-Gun (고성산불로 인한 시설물피해특성 연구)

  • Yeom, Chanho;Lee, Si-young;Park, Houngsek;Kwon, Chungeun
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.4
    • /
    • pp.469-478
    • /
    • 2019
  • Purpose: In this studies we examine the facilities damage characteristics caused by forest fire. Therefore, we surveyed damaged facilities from forest fire which was occurred on Goseong-Gun on march 28 in 2019.(damaged areas was 40ha) The types of facilities uses were house, public facility, warehouse and so on. 17 facilities were destroyed. The purpose of this study was to for establishing a disaster safety village in rural areas where damage from a similar type of disaster occurs repeatedly by conducting the consciousness survey targeting at experts and disaster safety officials in a local government. Method: We surveyed meteorological factors(temperature, wind speed, wind direction, humidity) per a minute for analyzing weather condition on Goseong-Gun when forest fire was occurred, spread and extinguished. And we surveyed forest fire risk factors(a slope degree, a slope direction, a geographical feature, a distance between forest and facility, main species, the existence of crown fire ignition, the direction of facility, the main material of building) around 10 damaged facilities. Finally, we analyzed damage pattern of facilities using meteorological factor and forest fire reisk fator Result: The weather condition of Kanseonng AWS (No.517) was high temperature, arid and strong wind, when the forest fire was occurred and spread. An average wind speed was 4.1m/s and the maximum wind speed was 11.6m/s. The main direction of wind was W(225~315°). Damaged facilities were located on the steep slope area and on the mountaintop. The forest density around facilities was high and main species was korean red pine. The crown fire was occurred in the forest around damaged facilities. The average distance was 13.5m from forest to facilities. When the main matarial of building was made by fire resistance materials (for example, rainforced concrete), the damage was slightly. on the other hand, when by flammable material (for example, a Sandwich Panel), the facilities were totally destroyed Conclusion: The results of this research which were the thinning around house, making a safety distance, the improvement of main material of building and etc, will be helpful for establishing a counter measure for a forest fire prevention of facilities in wild land urban interface

The Effects of Major Climatic Factors on Barely Response to NPK Fertilizers (대맥(大麥)의 NPK 비료응수(應酬)에 미치는 주요기상인자(主要氣象因子)들의 영향(影響)에 관(關)하여)

  • Park, Nae Jung;Lee, Choon Soo;Ryu, In Soo;Park, Chon Suh;Kim, Yung Sup
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.6 no.2
    • /
    • pp.129-136
    • /
    • 1973
  • In order to study the effects of climatic factors on barley responses to NPK fertilizers, the responses under the conditions of cold, moisture and drought damages and in different temperature regions, Nothern, Central, and Southern, which were devided according to average temperature for growing season of barley (from Nov. to May) were investigated from the results of NPK experiments which were carried out from Nov., 1965 to May 1969. The relationships between occurrence rate of cold, moisture, and drought damages and average or average lowest temperature in winter (Dec., Jan., and Feb), and the amount of precipitation in spring (Mar., Apr,. and May) were also investigated. 1. The lower the average lowest temperature, the higher the occurrence rate of cold damage of barley. When affected by cold damage, barley responded more significantly to P and K fertilizers. 2. The more the amount of precipitation in spring, the more the moisture damage and the less the drought damage. Damage from both moisture and drought were the lowest at 280mm. Since the average precipitation in spring in Korea is 230mm, drought damage is always more problem in terms of occurrence of damage, but total yield reduction is greater by moisture damage. 3. When affected by moisture damage, barley responded more to P and K fertilizers. In case of drought damage, only response to K was recognizable. 4. The reductions of barley yield due to cold, moisture, and drought damages were in average 31 (29-33), 42, and 19(12-25)%, respectively. 5. Average barley responses to NPK fertilizers were 44(34-58), 19(5-38), and 9(1-34)%, respectively by percent responses with regard to maximum possible yields. 6. Responses to nitrogen increased as the sunshine hours increased. Under dry condition, the response increased as the precipitation increased. However if the amount of precipitation was excessive or too little, the response was dropped markedly. 7. The responses to P and K were higher in North than South to the same degree. As the average temperature for growing season of barley (from Nov. to May) increased by $1^{\circ}C$, the percent responses to both P and K increased by 4.3%.

  • PDF

Growth and Lodging of Paddy Rice as Affected by Paclobutrazol Application under the Different Level of Nitrogen Fertilizer (질소수준(窒素水準)이 다른 조건하(條件下)에서 Paclobutrazol 처리(處理)가 수도생장(水稻生長) 및 도복(倒伏)에 미치는 영향(影響))

  • Im, I.B.;Lee, S.Y.;Lim, M.S.
    • Korean Journal of Weed Science
    • /
    • v.7 no.2
    • /
    • pp.171-178
    • /
    • 1987
  • This study was conducted to examine the possibility of complete lodging. prevention, the growth and yield of the paddy rice plant by paciobutrazol 0.6%G application at 15 days before heading under the several levels (0, 5, 10, 15, 20, 25, 30, 35, 40, 45 kg/10a) of nitrogen fertilizer in 1986. Culm length was shortened 10-15% by paclobutrazol application. The shortened rate of internode was very extreme on the 3rd and 4th internode in paclobutrazol application. Moment the height of center gravity and lodging index turned higher with increasing nitrogen fertilizer, on the other hand, those of paclobutrazol application were smaller than control. Lodging degree (0~4) was 1~3 above 25kg/10a level of nitrogen fertilizer in control, however, no more than 1 at 45kg/10a level of nitrogen fertilizer in paclobutrazol application. Ripened grain ratio and grain weight of paclobutrazol application were larger than those of control. Yield increased more 15-26% in paclobutrazol application than control. The nitrogen level of maximum yield was about 25kg/10a in control, but was 31kg/10a in paclobutrazol application.

  • PDF

Aeromagnetic Interpretation of the Southern and Western Offshore Korea (한국 서남근해에 대한 항공자력탐사 해석)

  • Baag Czango;Baag Chang-Eob
    • The Korean Journal of Petroleum Geology
    • /
    • v.2 no.2 s.3
    • /
    • pp.51-57
    • /
    • 1994
  • Analysis of the aeromagnetic data aquired by US Navy in the year 1969 permits us to predict a new sedimentary basin, Heugsan Basin, south of the known Gunsan Basin in Block Ⅱ. The basin appears to consist of three sub-basins trending NNW-SSE. The results of our analysis provide not only an independent assessment of the Gunsan Basin, but also new important information on the tectonic origin and mechanism for the two basins as well as for the entire region. The basin forming tectonic style is interpreted as rhombochasm associated with double overstepped left-lateral wrench faults. From the magnetic evidence, a few NE-SW trending major onshore faults are extended to the study area. We also interpreted the nature of the faults to be left-lateral wrenches. This new gross structural style is consistent with the results of recent Yeongdong Basin analysis by Lee. The senses of fault movement are also supported by the paleomagnetic evidence that the Philippine Sea had experienced an 80-degree clockwise rotation since the Eocene. Based on a 2 $\frac{1}{2}$ model study the probable maximum thickness of the sediments in the Gunsan Basin is approximately 7500 meters. We believe that the new Heugsan Basin was left unidentified because a high velocity layer may be overlying the basin. Because the overall structural configuration of the Heugsan Basin appears to be favorable for hydrocarbon accumulation, a detailed airborne magnetic survey is recommended in the area in order to verify the magnetic expression of this thick basin. A detailed subsequent marine gravity survey is also recommended in order to delineate the sedimentary section and to acquire supplemental data to the magnetic method only if an overlying high velocity layer is confirmed. Otherwise a high energy source seismic survey may be more effective.

  • PDF

A Study on Characters of Select Behaviors of Tourist - at a spa & resort - (관광객의 선택행동 특성에 관한 연구 - 온천리조트를 중심으로 -)

  • Oh, Jae-kyung
    • Journal of Distribution Science
    • /
    • v.4 no.2
    • /
    • pp.81-106
    • /
    • 2006
  • The value of Its visitors is very important factors on selection of a Spa & Resort. The first detailed purpose of this paper is to analyse the differences of select behaviors of a Spa & Resort according to the types of values of the visitors. The second aim is to conduct a research on the characters of select behaviors of the visitors. The third aim is to analyse the degree of satisfaction of the visitors, re-visitation and the intention of recommendation. The fourth purpose is to provide useful materials on analysis about the values of the visitors at various Spa & Resorts and to trigger dramatic effect of recuperation, relaxation with its visitor's needs met, the maximum of hotel's management profit at Spa & Resort's area and programs to activate the region's economy. Factor Analsis Routine of SPSS Windows Version 10.0 was applied to accomplish the issues of the study. The Applied analysis by research process are as follows; This paper applied Frequency analysis to figure out interviewee's demographic characters and various using types of the visitors, using their experience of visiting, Select influence, Visiting period, Accommodation they use, Accompanyist, Costs, Season, Transportation, The necessary time. This paper showed important correlation between the visitors' select attributes and behaviors after using it, between their personal value and behaviors after using it, between their individual value, motive of use and their select behavior of destinations. In accordance with it, Managers or developer of a Spa & Resort should make a plan after a sufficient review of the visitors' individual value. The visitor's value is changing continuously according to the change of spatial, occasional environment and should be assessed by those changes.

  • PDF

Optimum Fertilization Based on Soil Testing for Chinese Cabbage Cultivation in Plastic Film Houses (시설재배지 토양 검정에 의한 배추의 적정 시비량)

  • Hong, Soon Dal;Kang, Bo Goo;Kim, Jai Joung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.31 no.1
    • /
    • pp.16-24
    • /
    • 1998
  • To determine the optimum application of fertilizers for the cultivation of Chinese cabbage in plastic film house, twenty soils which contain different salts contents were taken from 4 different area of plastic film house cultivation, Youngdong. Boeun county, Cheongweon county, and Cheongju city. The dry weight and the amount of N. P, and K uptakes of Chinese cabbage in the plot of no fertilization were considered as the factors representing the fertility of the soil. And a difference of dry weight and the amounts of N, P, and K uptakes of plants between the plot of fertilization and no fertilization were considered as the factors representing the total effect of fertilizer and fertilizer N, P, and K effects. respectively. These factors of soil fertility and fertilizer effects were estimated by correlation and regression with soil tests in order to find the critical levels and recommended method for optimum fertilization of Chinese cabbage. Chinese cabbage transplanted in two soils, having the electrical conductivity of 9.3 and 15.2 dS/m, were not able to root due to the salts toxicity. The content of inorganic N, the electrical conductivity, and CEC were founded to have significant correlation with the factors of both the soil fertility and fertilizer effects for the cultivation of Chinese cabbage. To determine the weighting degree for the productivity and the fertilizer effects, the standardized partial regression coefficient was analyzed by regression among the factors of fertility, the fertilizer effects, and the soil tests. The coefficient for inorganic N($NH_4-N$ and $NO_3-N$) was obtained as the absolute value of 756-1871 and this value was extremely higher than those of other soil tests which was 0.07-4.11. These results suggested that the content of inorganic N is the best tests for the estimation of the productivity and the fertilizer effects for the cultivation of Chinese cabbage in plastic film house. The critical level of inorganic N($NH_4-N+NO_3-N$) estimated by Cate-Nelson split method for maximum productivity and zero point of fertilizer effect was 220 mg/kg for all the factors of estimation. These results suggested that no application of fertilizer N. P, and K is required at the critical level of inorganic N of soil. Consequently the optimum application of fertilizer N, P, and K for the cultivation of Chinese cabbage in plastic film house was possible to determine by the critical level of inorganic N of soil. The critical level of electrical conductivity was estimated as 2.8 dS/m by the same method.

  • PDF