• Title/Summary/Keyword: Max-Max frequency

Search Result 431, Processing Time 0.032 seconds

Distributional Characteristics of Microcrack in Tertiary Crystalline Tuff from Northeastern Gyeongsang Basin (경상분지 북동부의 제3기 결정질 응회암에서 발달하는 미세균열의 분포특성)

  • Park, Deok-Won;Lee, Chang-Bum
    • The Journal of the Petrological Society of Korea
    • /
    • v.18 no.4
    • /
    • pp.315-336
    • /
    • 2009
  • We have studied the orientational characteristics of microcrack frequency, it's length and density in Tertiary crystalline tuff from the northeastern part of the Gyeongsang Basin. 134 sets of microcracks on horizontal surfaces of 3 rock samples from Heunghae-eup were distinguished by enlarged photomicrographs of the thin sections. The variability in patterns among microcrack length-frequency histograms for three rock samples from different altitudes were derived. The pattern of histograms changes progressively from negative exponential form to log-normal form in proportion to altitude. The distribution pattern for rock sample no.1 from lower altitude shows the broad length distribution characterized by higher mean and median, and higher standard deviation. Meanwhile, this distribution pattern corresponds with characteristics of joint length distribution in sedimentary rocks of the lower part of the Gyeongsang Supergroup. The occurrence frequency of shorter microcracks increases toward both NW and NE directions from the $N0{\sim}10^{\circ}W$, with the dominant direction of $N80{\sim}90^{\circ}W$ and $N80{\sim}90^{\circ}E$, respectively. This distribution pattern represents the relative differences in formation timing among microcrack sets and the result of the new initiation of shorter microcracks. Meanwhile, the longest microcracks within $N60{\sim}70^{\circ}W$($L_{max}$:1.18 mm) and $N0{\sim}10^{\circ}W$($L_{max}$:0.80 mm) directions are seen, but this kind of microcracks are very limited in number. Whole domain of the directional angle($\theta$)-frequency(N), length(L) and density($\rho$) chart can be divided into five sections in terms of phases of the distribution of related curves. From the distribution chart, density curve shows five distinct peaks in the WNW-ESE($N70{\sim}80^{\circ}W$), NS~NNE-SSW($N0{\sim}10^{\circ}W$, $N10{\sim}20^{\circ}E$), ENE-WSW($N50{\sim}60^{\circ}E$), and nearly EW($N80{\sim}90^{\circ}E$) directions, respectively. Especially, main directions of faults correspond with the directional angle showing high density. Consequently, these distribution patterns of density curve reflect the representative maximum principal stress orientations suggested in previous studies.

A Design and Fabrication of the X-Band Transmit/Receive Module for Active Phased Array SAR Antennas (능동 위상 배열 SAR 안테나를 위한 X-대역 송수신 모듈의 설계 및 제작)

  • Chong, Min-Kil;Kim, Sang-Keun;Na, Hyung-Gi;Lee, Jong-Hwan;Yi, Dong-Woo;Baik, Seung-Hun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.10
    • /
    • pp.1050-1060
    • /
    • 2009
  • In this paper, a X-Band T/R-module for SAR(Synthetic Aperture Radar) systems based on active phased array antennas is designed and fabricated. The T/R modules have a and width of more than 800 MHz centered at X-Band and support dual, switched polarizations. The output power of the module is 7 watts over a wide bandwidth. The noise figure is as low as 3.9 dB. Phase and amplitude are controlled by a 6-bit phase shifter and a 6-bit digital attenuator, respectively. Further the fabricated T/R module has est and calibration port with directional coupler and power divider. Highly integrated T/R module is achieved by using LTCC(Low Temperature Co-fired Ceramic) multiple layer substrate. RMS gain error is less than 0.8 dB max. in Rx mode, and RMS phase error is less than $4^{\circ}$ max. in Rx/Tx phase under all operating frequency band, or the T/R module meet the required electrical performance m test. This structure an be applied to active phase array SAR Antennas.

Statistical Characteristics of Deepwater Waves along the Korean Coast (한국 연안 심해파의 통계적 특성)

  • Suh, Kyung-Duck;Kwon, Hyuk-Dong;Lee, Dong-Young
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.4
    • /
    • pp.342-354
    • /
    • 2008
  • Some statistical characteristics of deepwater waves along the Korean coast have been investigated using various sources of wave measurement and hindcasting data. For very large waves comparable to design waves, it is recommended to use the average value of the empirical formulas proposed by Shore Protection Manual in 1977 and by Goda in 2003 for the relation between significant wave height and period. The standard deviation of significant wave periods non-dimensionalized with respect to the mean value for a certain significant wave height varies between 0.04 and 0.21 with a typical value of 0.1 depending upon different regions and different ranges of significant wave heights. The mean and standard deviation of the principal deepwater wave direction are presented at the 106 coastal grid points along the Korean coast. For relatively large waves, the probability density function of the directional spreading parameter $s_{max}$ is expressed as a lognormal distribution. The most suitable frequency spectrum in the Korean coast is the TMA spectrum. The probability density function of the peak enhancement factor $\gamma$ is also expressed as a lognormal distribution, with its mean value of 2.94, which is close to the value in the North Sea.

Exercise Prescription and Dietary Modification for Prevention and Treatment of Chronic Degenerative Disease I. On Obesity and Diabetes (성인병의 예방과 치료를 위한 영양과 운동처방 I. 비만과 당뇨병에 미치는 영향)

  • 백영호;전병학
    • Journal of Life Science
    • /
    • v.9 no.2
    • /
    • pp.222-230
    • /
    • 1999
  • Obesity is an excessive increased state of total body fat, and diabetes is a disease lack or defect of insulin which controls blood sugar. The reason of obesity and diabetes are history, lack of exercise, overeating, stress and so forth. The principle of dietary modification in the obesity and diabetes are controling total calorie control, and taking orderly meals, and restricting high calorie food. General exercise guidance will recommend to take precedence over the medical diagnosis, case history test before the exercise begins, and the beginning of exercise. It start with light excercise, and gradually enhance intensity The fundamental and effective cure of obesity and diabetes is aerobic exercise (as jogging, swimming, playing tennis, aerobic dancing). It is reasonable for exercise intensity to be 60~80$\%$ HRmax(50~70$\%$ $Vo_2$ max) and for the duration to be 15~60minutes a day and frequency to be 3~6 times a week. Especially the exercise intensity may be changeable according to the, pattern of diabetes. The snack that contains carbohydrate during exercise will discontinue the exercise when insulin activity is reached on high peak, and it is a proper way taking 15~20g's carbohydrate contained food against possibility of the low blood sugar occurance after exercise, At last, it is much effective the exercise therapy is combined with the diet therapy for best diabetes treatment.

  • PDF

Design and Implementation of a Single-Chip 8-Bit Microcontroller (단일 칩 8비트 마이크로컨트롤러의 설계 및 구현)

  • Ahn, Jung-Il;Park, Sung-Hwan;Kwon, Sung-Jae
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.11 no.4
    • /
    • pp.72-81
    • /
    • 2006
  • In this paper, we first define a total of 64 instructions that are considered to be essential and frequently used, construct a datapath diagram, determine the control sequence using a finite state machine, and implement an 8-bit microcontroller using FPGA in VHDL. In the past, only functional simulation results of a rudimentary microcontroller were reported, the microcontroller lacked interrupt handling capability, or it was not implemented in hardware. We have designed a self-contained 8-bit microcontroller such that it can perform data transfer, addition, and logical operations, as well as stack and external interrupt operations. Following timing simulation of the designed microcontroller, we implemented it in an FPGA and verified its operation successfully. The design and implementation has been done under the Altera MAX+PLUS II integrated development environment using the EP1K50TC144-3 chip. The maximum operating frequency, the total number of logic elements used, and the logic utilization were found to be 9.39 MHz, 2813, and 97%, respectively. The result can be used as a microcontroller IP, and as needs arise, the VHDL code can be modified accordingly.

  • PDF

Interaction of Resveratrol and Genistein with Nucleic Acids

  • Usha, Subbiah;Johnson, Irudayam Maria;Malathi, Raghunathan
    • BMB Reports
    • /
    • v.38 no.2
    • /
    • pp.198-205
    • /
    • 2005
  • Resveratrol (RES) and genistein (GEN) are the dietary natural products known to possess chemopreventive property and also the ability to repair DNA damage induced by mutagens/carcinogens. It is believed that the therapeutic activity of these compounds could be primarily due to their interaction with nucleic acids but detailed reports are not available. We here explore the interaction of these drugs with nucleic acids considering DNA and RNA as a potential therapeutic target. The interaction of RES and GEN has been analysed in buffered solution with DNA [saline sodium citrate (SSC)] and RNA [tris ethylene diammine tetra acetic acid (TE)] using UV-absorption and Fourier transform infrared (FTIR) spectroscopy. The UV analysis revealed lesser binding affinity with nucleic acids at lower concentration of RES (P/D = 5.00 and 10.00), while at higher drug concentration (P/D = 0.75, 1.00 and 2.50) hyperchromic effect with shift in the ${\lambda}_{max}$ is noted for DNA and RNA. A major RES-nucleic acids complexes was observed through base pairs and phosphate backbone groups with K = $35.782\;M^{-1}$ and K = $34.25\;M^{-1}$ for DNA-RES and RNA-RES complexes respectively. At various concentrations of GEN (P/D = 0.25, 0.50, 0.75, 1.00 and 2.50) hyperchromicity with shift in the ${\lambda}_{max}$ from 260 $\rightarrow$ 263 om and 260 $\rightarrow$ 270 nm is observed for DNA-GEN and RNA-GEN complexes respectively. The binding constant (from UV analysis) for GEN-nucleic acids complexes could not be obtained due to GEN absorbance overlap with that of nucleic acids at 260 nm. Nevertheless a detailed analysis with regard to the interaction of these drugs (RES/GEN) with DNA and RNA could feasibly be understood by FTIR spectroscopy. The NH band of free DNA and RNA which appeared at $3550-3100\;cm^{-1}$ and $3650-2700\;cm^{-1}$ shifted to $3450-2950\;cm^{-1}$ and $3550-3000\;cm^{-1}$ in DNA-RES and RNA-RES complexes respectively. Similarly shifts corresponding to $3650-3100\;cm^{-1}$ and $3420-3000\;cm^{-1}$ have been observed in DNA-GEN and RNA-GEN complexes respectively. The observed reduction in NH band of free nucleic acids upon complexation of these drugs is an indication of the involvement of the hydroxyl (OH) and imino (NH) group during the interaction of the drugs and nucleic acids (DNA/RNA) through H-bonded formation. The interaction of RES and GEN with bases appears in the order of G $\geq$ T > C > A and A > C $\geq$ T > G. Further interaction of these natural compounds with DNA and RNA is also supported by changes in the vibrational frequency (shift/intensity) in symmetrical and asymmetrical stretching of aromatic rings of drugs in the complex spectra. No appreciable shift is observed in the DNA and RNA marker bands, indicating that the B-DNA form and A-family conformation of RNA are not altered during their interaction with RES and GEN.

The Effect of Pelvic Traction and Muscle Energy Technique on Static Standing Balance in Hemiplegia Patients (골반견인과 근 에너지기법이 편마비 환자의 정적선자세에 미치는 영향)

  • Bae, Jun-Ho;Han, Jin-Tae;Bae, Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.17 no.4
    • /
    • pp.537-557
    • /
    • 2005
  • The purpose of this study was to investigate the effect of pelvic traction and muscle energy technique(MET) for hemiplegic patients on static standing balance. The scale for static standing balance is measured by using mean balance(%), frequence(Hz), sway area($mm^2$), sway path(mm), max sway velocity(mm/s), ant/post sway angle($^{\circ}$), lateral sway angle($^{\circ}$), sway number, change of pelvic height is measured in relation to the height of ASIS and PSIS. The subjects of this study were thirty hemiplegic patients: 15men and 15 women, with an average ages of 50.80 years. The thirty subjects were divided into 3 group of 10 at random ; ten subjects had pelvic traction after bobath therapy (the pelvic traction group), ten subjects had muscle energy technique after bobath therapy (the MET group), and ten subjects had only bobath therapy (the control group). Static standing balance was measured using BPM (balance performance monitor; data print software version 5.3), pelvic height was measured using height measuring with an adjustable horizontal arm. In order to assure the statistical significant of the result, an one-way ANOVA, the paired t-test, and a person's correlation were applied at the.05 level of significance. The results of this study were as follows: 1) The change in pelvic height were statistically significant between the pelvic traction group, the MET group and the control group on pre-treatment and post-treatment(p<.05). 2) The change in affected and non-affected on weight bearing were not statistically significant between the pelvic traction group, the MET group and the control group on pre-treatment and post-treatment(p>.05). 3) The change in frequency were statistically significant between the MET group, the control group and the pelvic traction group on pre-treatment and post-treatment(p<.05). 4) The change in sway area were statistically significant between the MET group, the control group and the pelvic traction group on pre-treatment and post-treatment(p<.05). 5) The change in sway pa1h were statistically significant between the pelvic traction group, the MET group and the control group on pre-treatment and post-treatment(p<.05). 6) The change in max sway velocity were statistically significant between the pelvic traction group, the MET group and the control group on pre-treatment and post-treatment(p<.05). 7) The change in ant/post sway angle were statistically significant between the pelvic traction group, the MET group and the control group on pre-treatment and post-treatment(p<.05). 8) The change in lateral sway angle were statistically significant between the pelvic traction group, the MET group and the control group on pre-treatment and post-treatment(p<.05). 9) The change in sway number were statistically significant between the pelvic traction group, the MET group and the control group on pre-treatment and post-treatment(p<.05). In conclusion, there was a difference between the experimental group and the control group. In the future, we have to study continuously about pelvic traction and muscle energy technique in hemiplegic patients.

  • PDF

Evaluation of a Traffic Noise Predictive Model for an Active Noise Cancellation (ANC) System (능동형 소음저감 기법을 위한 도로교통소음 예측 모형 평가 연구)

  • An, Deok Soon;Mun, Sung Ho;An, Oh Seong;Kim, Do Wan
    • International Journal of Highway Engineering
    • /
    • v.17 no.6
    • /
    • pp.11-18
    • /
    • 2015
  • PURPOSES : The purpose of this thesis is to evaluate the effectiveness of an active noise cancellation (ANC) system in reducing the traffic noise level against frequencies from the predictive model developed by previous research. The predictive model is based on ISO 9613-2 standards using the Noble close proximity (NCPX) method and the pass-by method. This means that the use of these standards is a powerful tool for analyzing the traffic noise level because of the strengths of these methods. Traffic noise analysis was performed based on digital signal processing (DSP) for detecting traffic noise with the pass-by method at the test site. METHODS : There are several analysis methods, which are generally divided into three different types, available to evaluate traffic noise predictive models. The first method uses the classification standard of 12 vehicle types. The second method is based on a standard of four vehicle types. The third method is founded on 5 types of vehicles, which are different from the types used by the second method. This means that the second method not only consolidates 12 vehicle types into only four types, but also that the results of the noise analysis of the total traffic volume are reflected in a comparison analysis of the three types of methods. The constant percent bandwidth (CPB) analysis was used to identify the properties of different frequencies in the frequency analysis. A-weighting was applied to the DSP and to the transformation process from analog to digital signal. The root mean squared error (RMSE) was applied to compare and evaluate the predictive model results of the three analysis methods. RESULTS : The result derived from the third method, based on the classification standard of 5 vehicle types, shows the smallest values of RMSE and max and min error. However, it does not have the reduction properties of a predictive model. To evaluate the predictive model of an ANC system, a reduction analysis of the total sound pressure level (TSPL), dB(A), was conducted. As a result, the analysis based on the third method has the smallest value of RMSE and max error. The effect of traffic noise reduction was the greatest value of the types of analysis in this research. CONCLUSIONS : From the results of the error analysis, the application method for categorizing vehicle types related to the 12-vehicle classification based on previous research is appropriate to the ANC system. However, the performance of a predictive model on an ANC system is up to a value of traffic noise reduction. By the same token, the most appropriate method that influences the maximum reduction effect is found in the third method of traffic analysis. This method has a value of traffic noise reduction of 31.28 dB(A). In conclusion, research for detecting the friction noise between a tire and the road surface for the 12 vehicle types needs to be conducted to authentically demonstrate an ANC system in the Republic of Korea.

Development of Vibration and Impact Noise Damping Wood-Based Composites -Synthesis of the Polymer Showing a Broad Damping Peak (진동·충격음 흡수성 목질계 복합재료의 개발 -폭 넓은 감쇠곡선을 나타내는 고분자의 합성-)

  • Lee, Hyun-Jong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.27 no.2
    • /
    • pp.15-22
    • /
    • 1999
  • Polymeric meterials that are used for noise and vibration damper in wood/polymer/wood sandwich composites, must have a high loss factor(tan ${\delta}$), and at the same time the storage modulus(E) of $5{\times}10^7$ to $10^9$ dyne/$cm^2$ must withstand over a wide temperature and frequency ranges. In this study, the series of epoxy resinlpolyacrylate interpenetrating polymer networks(IPNs) were synthesized by simultaneous polymerization. Their dynamic tensile properties were measured at 110Hz using Rheovibron instrument. Composite damping factor(tan ${\delta}_c$) and dynamic bending modulus($E_c,\;E_^{\prime\prime}c$) of wood/polymer/wood sandwich composites were measured at 110Hz using a Rheovibron in bending mode of vibration. These dynamic tensile studies indicated that cured epoxy resin/polyacrylates IPNs were semicompatible in the sense that both the shifting of T($E^{\prime\prime}_{max}$) or T(tan ${\delta}_{max}$) and the broadening of glass transition temperature range were observed. Especially, the cured Epikote871/P(n-BMA) IPNs of composition 70/30 to 50/50 showed a relatively high tan a and appropriate E' value over a wide temperature range; consequently the tan a e curves of wood/IPNs/wood sandwich composites was broadened over a wide temperature range.

  • PDF

Major B-H Loop Measurement of Toroidal Shape Magnetic Powder Core (토로이드형 분말코어의 Major B-H Loop 측정)

  • Son, Derac
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.3
    • /
    • pp.76-80
    • /
    • 2014
  • Toroidal cores made of metallic powder requires large magnetic field strength up to few decade kA/m to obtain major hysteresis loop. To overcome thermal heat generation problem from large exciting current during measurement, we have employed a real time hysteresis loop tracer which can digitize and calculate B-H signals in personal computer as real time. For example, when we magnetize specimen at 10 Hz frequency, we could display hysteresis loops 10 times per second. Using the real time hysteresis loop tracer, we could measure major hysteresis loop of toroidal shape metallic powder core at maximum flux density or maximum magnetic field strength to be measured within 5 second not to significant increasement of specimen temperature due to the heat dissipation from coil windings. For the constructed hysteresis loop tracer, we could measure hysteresis loop at magnetic field strength higher than 50 kA/m for the toroidal shape specimen.