• Title/Summary/Keyword: Max-Max frequency

Search Result 431, Processing Time 0.023 seconds

Human Effect for Commercial Wireless Power Transfer System Operating at Low Frequency (상용 자기유도방식 무선전력전송 시스템의 인체영향 분석)

  • Kang, Jun-Seok;Lee, Seungwoo;Hong, Ic-Pyo;Cho, In-Kui;Kim, Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.5
    • /
    • pp.382-390
    • /
    • 2017
  • In this paper, we consider particular exposure scenarios to evaluate human effects for inductive commercial wireless charging device operating at low frequency. The coil used in this study is the A10 model in Qi standard proposed by WPC(Wireless Power Consortium), and input power is 5 W to the operating frequency of 155 kHz. In perfectly aligned condition, the max leakage magnetic field is $257.58{\mu}T$ which is obtained at the side of the device, and it is exceeded about 7.4 times of the ICNIRP 1998 reference level. The SAR is evaluated with homogeneous phantom which has electric constants of wet skin. The max value of the SAR is $134.47{\mu}W/kg$ which is obtained at the side of the device also, and it is much lower than the international guidelines. Especially, it showed higher SAR values in case of misalignment condition, so we will need to consider the misalignment condition importantly when we evaluate human effects for wireless power transfer system.

The Changes of Breathing Pattern Observed During Maximal Exercise Testing in the Patients with Chronic Airflow Obstruction : the Correlation Between the Change of Inspiratory Duty Cycle and the Degree of Airflow Obstruction (만성기도폐쇄 환자에서 최대운동부하시 관찰되는 호흡양상 - 기도폐쇄정도와 흡기책임비율변화 사이의 상관관계 -)

  • Lee, Kye-Young;Jee, Young-Koo;Kim, Keun-Youl
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.3
    • /
    • pp.574-582
    • /
    • 1997
  • Background : Normal humans meet the increased ventilatory need during exercise initially by the increase of tidal volume (TV) and later by the increase of respiratory frequency (Rf). And the inspiratory duty cycle (Ti/Ttot) is also increased more than 50% for the compensation of the decrease of respiratory cycle provoked by the increase of respiratory frequency. The patients with chronic airflow obstruction show rapid and shallow breathing pattern during exercise because of the decreased ventilatory capacity and the increased dead space ventilation. However, the studies about the change of inspiratory duty cycle are only a few and there is no literature about the relationship between the change of inspiratory duty cycle and the degree of airflow obstruction. Methods : The subjects were the twelve patients with chronic airflow obstruction (CAO) and ten normal people. The incremental exercise test was done. The increase of work load was 10 W in CAO group and 25 W in normal control group. The analysis of the results was done by the comparison of the parameters such as minute ventilation (VE), TV, Rf, physiologic dead space (Vd/Vt), and inspiratory duty cycle between the two groups. Each parameters were compared after transformation into % control duration base that means dividing the total exercise time into five fractions and % control duration data were obtained at rest, 20%, 40%, 60%, 80%, and max. Statistical analysis was done by repeated measure ANOVA using SAS program. Results : The changes of VE and TV were significantly different between two groups while the change of Rf was not significant. The decrease of Vd/Vt was significantly low in CAO group. Ti/Ttot was markedly increased from 38.4 + 3.0% at rest to 48.6 + 4.5% at max in normal control group while Ti/Ttot showed little change from 40.5 + 2.2% at rest to 42.6 + 3.5% at max. And the change of inspiratory duty cycle showed highly good correlation with the degree of airflow obstruction (FEV1%). (r=0.8151, p < 0.05). Conclusions : The increase of Ti/Ttot during exercise observed in normal humans is absent in the patients with CAO and the change of Ti/Ttot is well correlated with the degree of airflow obstruction.

  • PDF

Design of Folded Monopole Internal Antenna for KPCS Mobile Phone Handset (휴대폰용 접힌 모노폴 내장형 안테나 설계)

  • Son, Tae-Ho
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.6 no.2
    • /
    • pp.113-118
    • /
    • 2007
  • KPCS internal antenna in this paper, is designed and fabricated using the theory based on the folded monopole antenna. I propose folded monopole internal antenna which has high gain low profile structure with easy installation into the handset of mobile phone. Design frequency is 1.8 GHz that is a center frequency of Korea PCS frequency band, and the impedance variances due to change of antenna structure as a length and width are simulated. Measurements show that input VSWR range under 2:1 is 1.72 - 1.88 GHz, and radiated H-plane pattern is omnidirectional under passive state. Active sensitivities and output power of phone applied antenna are $-105\;{\sim}\;-108\;dBm$ and $22.5\;{\sim}\;23.6\;dBm$ max., respectively.

  • PDF

Multiband Microstrip-Fed Right Angle Slot Antenna Design for Wireless Communication Systems

  • Rakluea, Paitoon;Anantrasirichai, Noppin;Janchitrapongvej, Kanok;Wakabayashi, Toshio
    • ETRI Journal
    • /
    • v.31 no.3
    • /
    • pp.271-281
    • /
    • 2009
  • This paper presents a novel multiband microstrip-fed right angle slot antenna design technique for multiple independent frequency bands. The new technique uses various slot sizes at various appropriate positions. We first propose a tri-band slot antenna consisting of three right angle slots. Then, a quad-band slot antenna is developed with four right angle slots which achieves slant ${\pm}45^{\circ}$ linear polarization, omnidirectional pattern coverage, good antenna gain, and acceptable impedance bandwidths over all the operating frequency range. Moreover, an open-circuited tuning stub is introduced to achieve good impedance matching. Both proposed antennas are designed on a ground plane of RT/duroid 5880 substrate with a thickness of 1.575 mm. The real measurable results show that the desired frequencies used in wireless communication systems, namely, WLAN and WiMax, are efficiently achieved.

  • PDF

Somatic Embryogenesis in Immature Zygotic Embryo Cultures of Korean Soybean (Glycine max L.) Culitivars and Effect of 2,4-Dichlorophenoxyacetic Acid on Somatic Embryo Morphology (한국 품종 대두(Glycine max L) 미숙배로부터 체세포배발생과 배지의 2,4-Dichlorophenoxyacetic Acid 농도가 체세포배의 형태에 미치는 영향)

  • Pil S Choi;Yoong Y. SOH;Duck Y.Choi;ang R. LIU
    • Korean Journal of Plant Tissue Culture
    • /
    • v.21 no.1
    • /
    • pp.7-14
    • /
    • 1994
  • Immature zygotic embryos of five Korean soybean cultivars cultured on Murashige and Skoog's (MS) medium supplemented with various concentrations of 2,4-Dichlorophenoxyacetic acid (2,4-D) produced somatic embryos without forming an intervening callus. The highest frequency (up to 90%) of somatic embryo formation was obtained when zygotic embryos were cultlued on medium containing 1 to 2 mga 2, 0-D in four cultivars. However the frequency was highly variable to the cultivars. Transversely sliced primary somatic embryo halves were also capable of forming secondary embryos at frequencies of up to 70% when cultured on medium containing 0.1 to 1 mg/L 2,4-D. Somatic embryos formed on zygotic embryos cultured on medium containing 0.1 to 0.2 mg/L 2,4-D had two cotyledons more frequently than one horn-type cotyledon and those on medium containing 0.5 to 4mg/L 2,4-LD had a horm-type cotyledon at a prominently higher freequency. However somatic embryos on medium containing 10mg/L or higher concentrations of 2,4-D were usually shunted at the globular stage even after transfer to medium containing lower concentrations of 2,4-D or other growth regulators. non somatic embryos with one or two cotyledons or a hem-type cotyledon were transferred to medium containing $GA_3$, those with two cotyledons converted to plantlets at a higher frequency (25%) than the others.

  • PDF

High Gain and Broadband Millimeter-wave MHEMT Cascode Amplifier (고이득 및 광대역 특성의 밀리미터파 MHEMT Cascode 증폭기)

  • An, Dan;Lee, Bok-Hyung;Lim, Byeong-Ok;Lee, Mun-Kyo;Baek, Yong-Hyun;Chae, Yeon-Sik;Park, Hyung-Moo;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.8
    • /
    • pp.105-111
    • /
    • 2004
  • In this paper, millimeter-wave high gain and broadband MHEMT cascode amplifiers were designed and fabricated. The 0.1 ${\mu}{\textrm}{m}$ InGaAs/InAlAs/GaAs Metamorphic HEMT was fabricated for cascode amplifiers. The DC characteristics of MHEMT are 640 mA/mm of drain current density, 653 mS/mm of maximum transconductance. The current gain cut-off frequency(f$_{T}$) is 173 GHz and the maximum oscillation frequency(f$_{max}$) is 271 GHz. By using the CPW transmission line, the cascode amplifier was designed the matched circuit for getting the broadband characteristics. The designed amplifier was fabricated by the MHEMT MIMIC process that was developed through this research. As the results of measurement, the 1 stage amplifier obtained 3 dB bandwidth of 37 GHz between 31.3 to 68.3 GHz. Also, this amplifier represents the S21 gain with the average 9.7 dB gain in bandwidth and the maximum gain of 11.3 dB at 40 GHz. The 2 stage amplifier has the broadband characteristics with 3 dB bandwidth of 29.5 GHz in the frequency range from 32.5 to 62.0 GHz. The 2 stage cascode amplifier represents the high gain characteristics with the average gain of 20.4 dB in bandwidth and the maximum gain of 22.3 dB at 36.5 GHz.z.z.

Frequency Reconfigurable Antenna for Multi Mode & Multi Band (MMMB) Communication Systems (셀룰러 및 커낵티비티 대역 통합용 동시동작모드 주파수 재구성 안테나)

  • Park, Se-Hyun;Yang, Chan-Woo;Jung, Chang-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.6
    • /
    • pp.1170-1174
    • /
    • 2009
  • Two frequency-reconfigurable antennas have been designed and combined in a space with limited volume, i.e., 40mm ${\times}$ 20mm ${\times}$ 6mm. Each antenna can be reconfigured to operate at different frequency bands depending on the state of an embedded switch, which is implemented using a PIN diode. The first antenna can be switched between 0.82GHz ${\sim}$ 0.96GHz band (GSM/ CDMA) and 1.7GHz ${\sim}$ 2.17GHz band (DCS/ PCS/ WCDMA), which are cellular bands. The second antenna can be switched between 3.4GHz ${\sim}$ 3.6GHz band (mWiMax) and 2.3GHz ${\sim}$ 2.5GHz, 5.15GHz ${\sim}$ 5.35GHz bands (WiBro/ WLAN 11a/b/g/n), which are connectivity bands. The proposed combined antenna operates both over cellular bands and connectivity bands concurrently. The choice of the operation bands is made independently by the states of the two switches.

Effects of Ultrasonic Scanner Setting Parameters on the Quality of Ultrasonic Images (초음파 진단기의 설정 파라미터가 영상의 질에 미치는 효과)

  • Yang, Jeong-Hwa;Lee, Kyung-Sung;Kang, Gwan-Suk;Paeng, Dong-Guk;Choi, Min-Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.2
    • /
    • pp.57-65
    • /
    • 2008
  • Setting parameters of Ultrasonic scanners influence the quality of ultrasonic images. In order to obtain optimized images sonographers need to understand the effects of the setting parameters on ultrasonic images. The present study considered typical four parameters including TGC (Time Gain Control), Gain, Frequency, DR (Dynamic Range). LCS (low contrast sensitivity) was chosen to quantitatively compare the quality of the images. In the present experiment LCS targets of a standard ultrasonic test phantom (539, ATS, USA) were imaged using a clinical ultrasonic scanner (SA-9000 PRIME, Medison, Korea). Altering the settings in the parameters of the ultrasonic scanner, 6 LCS target images (+15 dB, +6 dB, +3 dB, -3 dB, -6 dB, -15 dB) to each setting were obtained, and their LCS values were calculated. The results show that the mean pixel value (LCS) is the highest at the max setting in TGC, mid to max in gain and pen mode in frequency and 40-66 dB in DR. Among all images, the image being the highest in LCS was obtained at the setting of DR 40 dB. It is expected that the results will be of use in setting the parameters when ultrasonically examining masses often clinically found In either solid lesions (similar to +15, +6, +3 dB targets) or cystic lesions (similar to -15, -6, -3 dB targets).

Nanoparticle Contrast in Magneto-Motive Optical Doppler Tomography

  • Kim, Jee-Hyun;Oh, Jung-Hwan
    • Journal of the Optical Society of Korea
    • /
    • v.10 no.3
    • /
    • pp.99-104
    • /
    • 2006
  • We introduce a novel contrast mechanism for imaging superparamagnetic iron oxide (SPIO) nanoparticles (average diameter ${\sim}100nm$) using magneto-motive optical Doppler tomography (MM-ODT), which combines an externally applied temporally oscillating high-strength magnetic field with ODT to detect the nanoparticles flowing through a glass capillary tube. A solenoid cone-shaped ferrite core extensively increased the magnetic field strength ($B_{max}=1\;T,\;{\Delta}|B|^2=220T^2/m$) at the tip of the core and also focused the magnetic force on targeted samples. Nanoparticle contrast was demonstrated in a capillary tube filled with the SPIO solution by imaging the Doppler frequency shift which was observed independent of the flow rate and direction. Results suggest that MM-ODT may be a promising technique to enhance SPIO nanoparticle contrast for imaging fluid flow.

An Accurate Small Signal Modeling of Cylindrical/Surrounded Gate MOSFET for High Frequency Applications

  • Ghosh, Pujarini;Haldar, Subhasis;Gupta, R.S.;Gupta, Mridula
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.4
    • /
    • pp.377-387
    • /
    • 2012
  • An intrinsic small signal equivalent circuit model of Cylindrical/Surrounded gate MOSFET is proposed. Admittance parameters of the device are extracted from circuit analysis and intrinsic circuit elements are presented in terms of real and imaginary parts of the admittance parameters. S parameters are then evaluated and justified with the simulated data extracted from 3D device simulation.