• Title/Summary/Keyword: Mattress

Search Result 202, Processing Time 0.021 seconds

Correction of Cup Ear using the Mattress suture (매트리스봉합을 이용한 수축귀의 교정)

  • Jang, Soo Won;Lee, Jang Hyun;Choi, Seung Suk;Tak, Min Sung
    • Archives of Plastic Surgery
    • /
    • v.36 no.1
    • /
    • pp.118-121
    • /
    • 2009
  • Purpose: Constricted ear, which is named by Tanzer includes lop ear, cup ear, and sort of prominent ear. It has classified three groups by Tanzer, especially grou I and IIA have been corrected by banner flap, Musgrave's technique, tumbling concha - cartilage flap, reversed banner flap and others. However, these techniques were too invasive for correcting mild degree of deformity. Therefore, we corrected the ear with mattress suture which is simple and less invasive. Method: The operations were done against 5 patients from 2005 March to 2008 April. All the cases were unilateral ears with constriction included helix and scaphoid fossa without difference in length between both ears. Though a posterior auricular skin incision, the folded cartilage is exposed and two parallel incisions on superior crus were made. After mattress suturing in cartilage, the superior crus of antihelix was formed and its force enables the folded portion to be in a normal anatomic position. Result: All of 5 patients got satisfactory results. There were no complications like hematoma or skin necrosis, and no recurrence during follow - up period(the average period was 9 months). And we couldn't recognize the difference between height of both auricles. Conclusion: Mattress suture is simple, less invasive, and suitable on correcting mild deformity of constricted ear with better result, so here we suggest the method.

Distance of insertion points in a mattress suture from the wound margin for ideal primary closure in alveolar mucosa: an in vitro experimental study

  • Lee, Won-Ho;Kuchler, Ulrike;Cha, Jae-Kook;Stavropoulos, Andreas;Lee, Jung-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.51 no.3
    • /
    • pp.189-198
    • /
    • 2021
  • Purpose: This study was conducted to determine how the distance of the near insertion points in a vertical mattress suture from the wound margin influences the pattern of primary closure in an in vitro experimental model. Methods: Pairs of 180 porcine gingival and alveolar mucosa samples were harvested from 90 pig jaws and fixed to a specially designed model. A vertical mattress suture was performed with the near insertion point at 3 different distances from the wound margin (1-, 3-, and 5-mm) on both the gingival and mucosal samples (6 groups; n=30 for each group). The margin discrepancy and the presence of epithelium between the wound margins were measured on histologic slides. Results: The margin discrepancy decreased significantly as the near insertion point became closer to the wound margin both in mucosal tissue (0.241±0.169 mm, 0.945±0.497 mm, and 1.306±0.773 mm for the 1-, 3-, and 5-mm groups, respectively) and in gingival tissue (0.373±0.304 mm, 0.698±0.431 mm, and 0.713±0.691 mm, respectively). The frequency of complications of wound margin adaptation reduced as the distance of the near insertion point from the wound margin decreased both in the mucosal and gingival tissues. Conclusions: Placing the near insertion point close to the wound margin enhances the precision of wound margin approximation/adaptation using a vertical mattress suture.

Effectiveness of chest compression by bystander on the home bed mattress

  • Hee-Jeong Ahn;Uk-Jin Choi;Gyu-Sik Shim
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.3
    • /
    • pp.173-180
    • /
    • 2024
  • The purpose of this study was to determine the accuracy of chest compression according to the patient body weight and the rescuer's weight when performing chest compression on a cardiac arrest patient that occurred on a home bed. From January 07 to January 19, 2023, 36 paramedic students from N and S universities who completed the KBLS provider curriculum of the Korea Cardiopulmonary Resuscitation Association were measured at the subject's knee position, the depth of the mattress being pressed by the weight of the manikin, and the depth of the mattress being pressed by the weight of the manikin were measured during continuous chest compression for 2 minutes. As a result of the study, if a child's cardiac arrest is found at home, the patient is moved to the floor to proceed with chest compression, and the first witness to find an adult cardiac arrest is recommended to proceed on the bed rather than force the patient under the bed to proceed with chest compression.

Study of Body Pressure for Adjustable Beds for Elderly (노약자를 위한 조절침대의 체압분포 연구)

  • Lee, Sae-Hwan
    • Journal of the Korea Furniture Society
    • /
    • v.25 no.4
    • /
    • pp.304-318
    • /
    • 2014
  • Bed for elderly and disabled, including the United States developed the industry Americas, and European countries, mainly in the production of products has dominated the world market. In large hospitals, and dependent products are sold at high prices. On the other hand, improvement of living standards of our country and to the advancement of residential culture of the demand for luxury products is increasing. The study of elderly Edition mattresses have been developed mainly in Europe to maximize the use of sleep can increase the efficiency of products has been studied. Due to the increase in elderly population Elderly Hospital, which is installed in the elderly silver town Edition requires the dissemination of the mattress in the bedroom several times a day resting and sleeping, eating, etc. Designing a variety of actions are needed. Edition of the elderly in Korea developed the design of bed with bed design and the manufacturer and the Institute for Ergonomics, welfare agencies and to build organic cooperation system under the direction of a professional designer to develop and you need to configure the space and the results of such actions by the distribution of cheap materials, ergonomic mattress for optimal development of behavior analysis to the need to promote the convenience of the user.

  • PDF

Estimation of Chest Compression Depth using two Accelerometers during CPR (심폐소생술에서 두 개의 가속도 센서를 활용한 흉부 압박 깊이 추정)

  • Song, Yeong-Tak;Oh, Jae-Hoon;Suh, Young-Soo;Chee, Young-Joon
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.5
    • /
    • pp.407-411
    • /
    • 2010
  • During the cardiopulmonary resuscitation (CPR), the correct chest compression depth and period are very important to increase the resuscitation possibility. For the feedback of chest compression depth, the depth monitoring device based on the accelerometer is developed and widely used. But this method tends to overestimate the compression depth on the bed. To overcome this limitation, the chest compression depth estimation method using two accelerometers is suggested With the additional accelerometer between the patient and mattress on the bed, the compression of the mattress is also measured and it is used to compensate the overestimation error. The experimental results show that the single accelerometer estimates as 61.4mm for the actual compression depth of 43.6mm on the mattress. The depth estimation with the dual accelerometer was 44.6mm which is close to the actual depth. With the automatic zeroing in every single compression, the integration error for the depth can be reduced. The dual accelerometer method is effective to increase the accuracy of the chest compression depth estimation.

Usefulness of an Additional Mattress Suture for the Extracranial Drainage Catheter

  • Eom, Dong Woong;Kim, Jung Soo;Jeon, Kyoung Dong;Kim, Hoon;Choi, Byeong Sam
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.5
    • /
    • pp.444-447
    • /
    • 2013
  • In most intracranial surgery cases, a drain catheter is inserted to prevent the collection of the wound hematoma or seroma. A drain catheter is also inserted to drain the hematoma or the cerebrospinal fluid. The drain catheter itself does not cause complications; but many complications occur during its removal, such as hematoma, seroma, air collection and pseudomeningocele formation. To prevent these complications, neurosurgeons perform a suture on the catheter to remove the site. In this study, an additional horizontal mattress suture and an anchoring suture to the drainage catheter are proposed. This method maintains negative pressure in the catheter insertion site during the catheter removal, compresses the catheter tunnel site and attaches the external wounds strongly. The technique is easy and safe to perform, and does not require an additional suture to remove the catheter.

Usability Evaluation and Company Supporting of Senior-friendly Products (고령친화제품 사용성평가 및 기업지원)

  • Jung, Kwang-Tae;Chun, Keyoung-Jin;Won, Byeong-Hee
    • The Journal of Korean Institute for Practical Engineering Education
    • /
    • v.2 no.2
    • /
    • pp.157-164
    • /
    • 2010
  • In these days, the frequency in use of senior friendly products including walker, mattress preventing bedsore, etc. is going up by an increase in the elderly population. In the case of the elderly, bad ergonomic design causes some problems in the aspects of usability and safety. In fact, lots of accidents came from using senior friendly products. In this paper, older adults' usability when using senior friendly products was studied through industry-university collaboration. Usability evaluation program was developed to support companies that develop or manufacture a senior-friendly product. Walker and mattress preventing bedsore were evaluated in aspect of its usability and the result were provided to the company.

  • PDF

Survey on the Use of Bed for Comfortable Sleeping (침대 사용시의 제반 현상에 대한 실태 조사)

  • Lee, Hyun-Ja;Hong, Kyung-Hi
    • Korean Journal of Human Ecology
    • /
    • v.10 no.4
    • /
    • pp.349-355
    • /
    • 2001
  • The use of bed in Korea has increased steadily, however, intensive survey on the general use and consumer's evaluation of their beds have not been performed sufficiently, yet. Thus, the purpose of this study is to investigate the actual use of the consumer and their degree of evaluation for the component of the bed as well as their feeling of discomfort on the various parts of body. More than one hundred users of commercial beds were responded to the survey. The results obtained were as follows: (1) Complaint about the depression of the mattress and the noise from the bed was apparent in the current use of beds. (2) Important physical variable related to the comfortable sensation of the sleeping was the degree of support in maintaining the natural shape of the spine and waist. Durability and the degree of hardness of the mattress were also important physical parameters of bed perceived by consumer. (3) The degree of discomfort on the back and waist during sleep was closely related to the comfort evaluation of the bed.

  • PDF

Reconstruction of a Traumatic Cleft Earlobe Using a Combination of the Inverted V-Shaped Excision Technique and Vertical Mattress Suture Method

  • Park, June Kyu;Kim, Kyung Sik;Kim, Seung Hong;Choi, Jun;Yang, Jeong Yeol
    • Archives of Craniofacial Surgery
    • /
    • v.18 no.4
    • /
    • pp.277-281
    • /
    • 2017
  • Traumatic cleft earlobes are a common problem encountered by plastic and reconstructive surgeons. Various techniques have been reported for the repair of traumatic cleft earlobes. Usually, the techniques of split earlobe repair are divided into two categories, namely straight- and broken-line repairs. Straight-line repair is simple and easy, but scar contracture frequently results in notching of the inferior border of the lobule. It can be avoided by the broken-line repair such as Z-plasty, L-plasty, or a V-shaped flap. Between April 2016 and February 2017, six patients who presented with traumatic cleft earlobe underwent surgical correction using a combination of the inverted V-shaped excision technique and vertical mattress suture method. All the patients were female and had a unilateral complete cleft earlobe. No postoperative notching of the inferior border the lobule occurred during 6-16 months of follow-up. Without the use of a broken-line repair, both the patients and the operators attained aesthetically satisfactory results. Therefore, the combination of the inverted V-shaped excision technique and vertical mattress suture method is considered useful in the treatment of traumatic cleft earlobes.

Analysis of Temperature Rise and Operation Time of Differential Spot Type Detector in Case of Mattress Fire in Multi-family House (다가구 주택의 매트리스 화재 시 차동식 스포트형 감지기의 온도상승 및 동작시간 분석)

  • Kim, Seo-Young;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.3
    • /
    • pp.97-102
    • /
    • 2021
  • This study developed a scenario to understand the reaction rate and operational time according to RTI value of rate of rise detector in each type in case of fire mattress. In the results of analyzing the reaction rate and operational time of detector in each scenario, in case when installing a single detector, the elevated temperature per minute was raised to 8℃/min ~ 9℃/min. In case when installing two detectors, it was raised to 9℃/min ~ 10℃/min. In case when installing three detectors, it was raised to 10℃/min. The horizontal distance between detector and mattress was 1.8m~2.5m. Whenever the number of detectors was increased, the horizontal distance was decreased. The operational time of detector was within maximum 540 seconds and minimum 420 seconds. As the research tasks in the future, there should be the researches on the effects of reaction rate of detector on the evacuation in case of fire through the result value of RSET by setting up the latency until the detector operates, and the researches on the safety by understanding if the operational time of detector is suitable for the evaluation standard of performance-centered design.