• Title/Summary/Keyword: Material transfer system

Search Result 516, Processing Time 0.026 seconds

Tribological Characteristics of Soft/Hard Coating for High-Speed Rotating Machine Elements (고속회전 하는 정밀부품을 위한 연질/경질 코팅의 트라이볼로지적 특성에 관한 연구)

  • 오진규;정구현;김대은;유제환;김형채
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.393-397
    • /
    • 2003
  • Recently, rotating elements which use mechanical and electrical systems have been utilized for high speed and accuracy to increase the performance. The most important thing to get a more reliable system is to understand the friction, wear and characteristics which has an effect on various coated surfaces. In this study, the tribologicali characteristics of various soft/hard materials were investigated by using a custom-built pin-on-reciprocator tester From the experimental results, it was found that the friction coefficients of the soft material coated surfaces were lower under various normal loads due to trier self-lubricating ability and material transfer to the counter surface.

  • PDF

Heat transfer of green timber wall panels (그린팀버월 패널의 열전달 특성)

  • Kim, Yun-Hui;Jang, Sang-Sik;Shin, Il-Joong
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.1
    • /
    • pp.115-120
    • /
    • 2011
  • 20% of total energy use to sustain temperature of building inside. In this reasons, researchers effort to improve the thermal insulation capacity with new wall system. Using appropriate materials and consisting new wall system should considered in energy saving design. OSB(Oriented strand board), Larch lining board used to consist wall system. $2{\sim}6$ Larch lining board has tongue & groove shape for preventing moisture. Comparing with gypsum board and green timber lining board as interior sheathing material, temperature difference of Green timber wall system was bigger than temperature difference of gypsum board wall system. This aspects indicate that Green timber wall system was revealed higher thermal insulation property than gypsum board wall system. Gypsum board portion transfer heat easily because temperature difference gradient of gypsum board wall system was smaller than OSB wall system. Total temperature variation shape of G-4-S and G-6-S show similar model but, temperature variation shape in green timber wall portion assume a new aspect. The purpose of this study was that possibility of thermal insulation variation and new composition of wall system identify to improve thermal insulation performance. In the temperature case, this study shows possibility of improving thermal insulation performance. Humidity, sunshine and wind etc. should considered to determine building adiabatic properties.

CHARACTERISTICS OF A NEW PNEUMATIC TRANSFER SYSTEM FOR A NEUTRON ACTIVATION ANALYSIS AT THE HANARO RESEARCH REACTOR

  • Chung, Yong-Sam;Kim, Sun-Ha;Moon, Jong-Hwa;Baek, Sung-Yeol;Kim, Hark-Rho;Kim, Young-Jin
    • Nuclear Engineering and Technology
    • /
    • v.41 no.6
    • /
    • pp.813-820
    • /
    • 2009
  • A rapid pneumatic transfer system (PTS) for an instrumental neutron activation analysis (INAA) is developed as an automatic irradiation facility involving the measurement of a short half-life nuclide and a delayed neutron counting system. Three new PTS designs with improved functions were constructed at the HANARO research reactor in 2006. The new system is composed of a manual system and an automatic system for both an INAA and a delayed neutron activation analysis (DNAA). The design and basic conception of a modified PTS are described, and the functions of system operation and control, radiation protection and emissions of radioactive gas are improved. In addition, a form of capsule transportation of these systems is tested. The experimental results pertaining to the irradiation characteristics with variation of the neutron flux and the temperature of the irradiation position with the irradiation time are presented, as is an analysis of the reference material for analytical quality control and uncertainty assessments.

Characterization of Microstructure and Thermal property of Ash Deposits on Fire-side Boiler Tube

  • Bang, Jung Won;Lee, Yoon-Joo;Shin, Dong-Geun;Kim, Younghee;Kim, Soo-Ryong;Baek, Chul-Seoung;Kwon, Woo-Teck
    • Journal of the Korean Ceramic Society
    • /
    • v.53 no.6
    • /
    • pp.659-664
    • /
    • 2016
  • Ash deposition of heat exchange boiler, caused mainly by accumulation of particulate matter, reduces heat transfer of the boiler system. Heat and mass transfer through porous media such as ash deposits mainly depend on the microstructure of deposited ash. Therefore, in this study, we investigated microstructural and thermal properties of the ash deposited on the boiler tube. Samples for this research were obtained from the fuel economizer tube in an industrial waste incinerator. To characterize microstructures of the ash deposit samples, scanning electron microscope (SEM), energy-dispersive spectroscopy (EDS), inductively coupled plasma optical emission spectroscopy (ICP-OES), X-ray diffraction (XRD) and BET analysis were employed. The results revealed that it had a porous structure with small particles mostly of less than a few micrometers; the contents of Ca and S were 19.3, 22.6% and 18.5, 18.7%, respectively. Also, the results showed that it consisted mainly of anhydrite ($CaSO_4$) crystals. - The thermal conductivities of the ash deposit sample obtained from the economizer tube in industrial waste incinerator were measured to be 0.63 and 0.54 W/mK at $200^{\circ}C$, which were about 100 times less than the thermal conductivity (61.32 W/mK) of the boiler tube itself, indicating that ash deposition on the boiler tube was closely related to a decrease in boiler heat transfer.

Heat Transfer Characteristics of High Temperature molten salt storage for Solar Thermal Power Generation (태양열 발전을 위한 고온 축열 물질의 열전달 특성)

  • Aiming, Mao;KIm, Ki-Man;Han, Gui-Young;Seo, Tae-Beom;Kang, Yong-Heack
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.3
    • /
    • pp.63-69
    • /
    • 2007
  • The heat transfer characteristics of inorganic salt for high temperature heat storage material of solar power system were examined. The inorganic salts employed in this study was a mixture of $NaNO_3$ and $KNO_3$ and the operating temperature range was determined by measuring the melting temperature with DSC and by measuring the thermal decomposition temperature with TGA. The heat transfer characteristics was qualitatively obtained in terms of temperature profiles of salt in the tanks during the heat storage and heat release process as a function of steam flow rates, steam inlet temperature and the inlet position of steam. The effects of steam flow rates and inlet temperature of steam were experimentally determined and the effect of natural convection was observed due to significant density difference with temperature.

A Electron-Transfer Study on Self-Assembled Viologen Monolayer In different Electrolytes Using Electrochemical Process (전기화학법을 이용한 전해질 변화에 따른 Viologen 자기조립박막의 전하이동 특성 연구)

  • Lee, Dong-Yun;Park, Sang-Hyun;Shin, Hoon-Kyu;Park, Jae-Chul;Chang, Jeong-Soo;Kwon, Young-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.878-881
    • /
    • 2004
  • When it converted solar energy or light energy into chemical energy, it studied the electric charge transfer property of the viologen which is used widely as the electron acceptor for the electric charge delivery mediation of the devices. It was formed monolayer in QCM by self-assembled viologen. The absorbed quantities of viologen's electron through peak current and to analyze the electron transfer property of viologen in redox reaction made experiments in cyclic voltammetry among the electrochemical process. It studied the electron transfer relation of viologen from changing the anion in 0.1M NaCl and $NaClO_4$ electrolyte and the interrelation between scan rate and peak current when scan rate increased twice.

  • PDF

Study on the heat transfer properties of raw and ground graphene coating on the copper plate

  • Lee, Sin-Il;Tanshen, Md.R.;Lee, Kwang-Sung;Munkhshur, Myekhlai;Jeong, Hyo-Min;Chung, Han-Shik
    • Journal of Power System Engineering
    • /
    • v.17 no.5
    • /
    • pp.78-85
    • /
    • 2013
  • A high thermal conductivity material, namely graphene is treated by planetary ball milling machine to transport the heat by increasing the temperature. Experiments were performed to assess the heat transfer enhancement benefits of coating the bottom wall of copper substrate with graphene. It is well known that the graphene is unable to disperse into base fluid without any treatment, which is due to the several reasons such as attachment of hydrophobic surface, agglomeration and impurity. To further improve the dispersibility and thermal characteristics, planetary ball milling approach is used to grind the raw samples at optimized condition. The results are examined by transmission electron microscopy, x-ray diffraction, Raman spectrometer, UV-spectrometer, thermal conductivity and thermal imager. Thermal conductivity measurements of structures are taken to support the explanation of heat transfer properties of different samples. As a result, it is found that the planetary ball milling approach is effective for improvement of both the dispersion and heat carriers of carbon based material. Indeed, the heat transfer of the ground graphene coated substrate was higher than that of the copper substrate with raw graphene.

Performance of a Latent Heat Storage System Using Two-Phase Closed Thermosyphon(I) - the Case of Constant Heat Input - (열싸이폰을 이용한 잠열축열시스템의 성능실험(I) - 열주입량이 일정한 경우 -)

  • Kim, Tae-Il;Kim, Ki-Hyun
    • Solar Energy
    • /
    • v.12 no.3
    • /
    • pp.28-36
    • /
    • 1992
  • The performance of a latent heat storage system using a thermosyphon as the heat transfer device between the heat source and the phase change material was investigated experimentally. In order to increase the effective conductivity of the phase change material, layers of copper wire mesh were immersed in the paraffin wax(Sunoco P-116) in such a way that they also may be considered as fins of the thermosyphon. The important results are as follows : (1) The void space of the wire mesh allowed the convection to occur, thus enhanced the performance of the system : (2) The increase of the number of layer of wire mesh increased the conduction heat transfer. However, it also had adverse effect of subduing convective motion of liquid wax : and (3) Overall heat transfer coefficient and thermosyphon conductance increased with the increase of the number of layer of wire mesh, whereas the heat transfer coefficient between the thermosyphon and the wax decreased.

  • PDF

Evaluation of Damage on a Concrete Bridge Considering the Location of the Vehicle Fire (차량 화재 위치를 고려한 콘크리트 교량의 손상 영향 평가)

  • Park, Jang Ho;Kim, Sung Soo
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.3
    • /
    • pp.80-87
    • /
    • 2013
  • Heat transfer analysis and thermal stress analysis for the concrete bridge was performed in order to investigate the damage of the concrete bridge by the fire of the vehicle. Changes in material properties, such as thermal conductivity, specific heat, density, elasticity, caused by temperature rise were considered. Heat transfer analysis and thermal stress analysis were performed according to the various location of the fire by ABAQUS. From the comparison of the numerical results, the degree of structural damage for the concrete bridge was investigated and considerations for the design of a concrete bridge against fire were identified.

Reliability Evaluation of Miniaturized Measurement Cell of Effective Thermal Conductivity for Hydrogen Storage Materials (소형 수소저장물질 유효열전도도 측정장치의 신뢰성 평가)

  • LEE, YOUNG HYO;IM, YEON HO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.26 no.5
    • /
    • pp.431-437
    • /
    • 2015
  • Recently, a miniaturized measurement cell of effective thermal conductivity was developed to evaulate the heat transfer characteristics of hydrogen stroage material in the initial step of its development. In this work, the realiablity issues which can occur from this miniaturization of measurement cell were studied in detail by both experiments and numerical simulation of heat transfer. $LaNi_5$ as a reference was used for the reliability evaluation of the miniaturized measurement cell. Numerical simulations of heat transfer for this measurement system were verified through comparison with the experimental data. Under these reliablity studies, we discuss how to overcome the inherent drawbacks of this miniaturized system in order to achieve the high reliability.