• 제목/요약/키워드: Material testing machine

검색결과 329건 처리시간 0.024초

바닥난방시스템 적용을 위한 MPCM 성능평가 (Performance evaluation of MPCM to apply for radiant floor heating system)

  • 정수광;전지수;김수민
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.475-479
    • /
    • 2012
  • Thermal energy storage (TES) systems using Microencapsulated phase change material (MPCM) have been recognized as one of the most advanced energy technologies in enhancing the energy efficiency and sustainability of buildings. We examined a way to incorporate MPCMs with building materials through application for wood-based flooring. Wood-based flooring is commonly used for floor finish materials of residential buildings in Korea. However, wood-based flooring has not performed the characteristic of heat storage. This study is aimed at manufacturing high thermal efficiency wood flooring by increasing its heat storage using MPCM. As a result, this study confirmed that MPCM is dispersed well in adhesive through the scanning electron microscopy analysis. From the differential scanning calorimetry analysis, it can be confirmed that this composite has the characteristic of a thermal energy storage material. Also, we analyzed how this composition was formed by physical combination through the Fourier transform infrared analysis. Also, we confirmed the bonding strength of the material by using the universal testing machine.

  • PDF

고장력 강판의 초음파 피로시험 (Ultrasonic Fatigue Test for a High Strength Steel Plate)

  • 염현호;정용찬;김차영;강기영;이문구;홍민성;전용호
    • 한국생산제조학회지
    • /
    • 제24권6호
    • /
    • pp.589-593
    • /
    • 2015
  • The demand of high cycle fatigue behavior on plate material is increasing because of its various applications. However, the high-cycle fatigue life data of the plate material is very rare compared to the rod material. Thus, in this study, a plate specimen is designed for the ultrasonic fatigue test because it is time efficient as compared to the conventional fatigue test. To apply the ultrasonic fatigue test, the specimen design is required to resonate at 20 kHz. Therefore, the dynamic elastic modulus was determined by measuring the resonance frequency with a piezoelectric element and laser doppler vibrometer (LDV). As a result, the plate specimen is designed and demonstrated using the ultrasonic fatigue testing machine. The ultrasonic fatigue test results were compared with the hydraulic fatigue test results.

폴리우레탄과 개질된 질화붕소로 이루어진 난연성 방열 복합체 (Flame Retardant and Heat Radiating Composite Consisting of Polyurethane and Modified Boron Nitride)

  • 김민규;이창록;조남주
    • 공업화학
    • /
    • 제31권5호
    • /
    • pp.487-494
    • /
    • 2020
  • 기존의 방열필름의 연소문제를 해결하기 위해 poly(tetra methylene glycol) (PTMG), 4,4'-methylenebis(phenyl isocyanate) (MDI)와 유기인이 도입된 실란 커플링제로 표면개질한 질화붕소를 사용하여 폴리우레탄과 개질된 질화붕소로 이루어진 복합체를 제작하였다. Fourier transform-infrared (FT-IR) 분광 분석을 통해 질화붕소의 개질과 복합체의 합성 여부를 확인하였다. 또 universal testing machine (UTM) 측정을 통해 개질된 질화붕소의 함량에 따른 복합체의 기계적 물성 변화를 확인하였으며, layser flash analysis (LFA)와 UL94 측정을 통해 열적 특성을 조사하였다. 그 결과, 복합체의 열전도도가 1.19 W/m·K로 증가하였으며, 자기소화성이 없어 타기 쉬운 폴리우레탄의 난연성이 UL94 V-1 등급으로 향상되었다.

Co-Cr 합금의 금속-도재 결합 강도 (Bond Strength between Co-Cr Alloy Metal and Ceramic)

  • 김민정;박광식
    • 한국콘텐츠학회논문지
    • /
    • 제21권3호
    • /
    • pp.602-608
    • /
    • 2021
  • 임상에서 사용되는 Co-Cr 합금과 도재 간의 접착 강도를 비교하기 위해 대조군으로 전통적인 주조(Casting) 방법, 실험군으로 Milling(Milling group), SLM(3d printing group) 시편을 제작하여 금속과 도재(ceramic) 간의 접착 강도를 비교 하였다. 합금과 도재간의 접착강도를 측정하기 위해 universal testing machine를 이용하여 3점 굴곡 시험을 시행하고, 결합강도 측정 후 금속-도재간의 계면을 관찰하였다. 금속-도재(ceramic) 간의 실험 결과 casting group 53.59 MPa, milling group 45.90 MPa, 3d printing group 58.34 MPa의 결과값을 보였고, 통계적으로 유의성은 없었다. 파절양상은 두 집단 시편의 대부분이 복합 파절양상(mixed failure)을 보였다. 본 연구는 3D 프린팅로 제작된 합금으로 합금-도재의 결합 강도값을 측정하였을 때 임상적으로 적용 가능한 수치를 보여 주었다.

Effect of moisture and drying time on the bond strength of the one-step self-etching adhesive system

  • Lee, Yoon;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • 제37권3호
    • /
    • pp.155-159
    • /
    • 2012
  • Objectives: To investigate the effect of dentin moisture degree and air-drying time on dentin-bond strength of two different one-step self-etching adhesive systems. Materials and Methods: Twenty-four human third molars were used for microtensile bond strength testing of G-Bond and Clearfil $S^3$ Bond. The dentin surface was either blot-dried or air-dried before applying these adhesive agents. After application of the adhesive agent, three different air drying times were evaluated: 1, 5, and 10 sec. Composite resin was build up to 4 mm thickness and light cured for 40 sec with 2 separate layers. Then the tooth was sectioned and trimmed to measure the microtensile bond strength using a universal testing machine. The measured bond strengths were analyzed with three-way ANOVA and regression analysis was done (p = 0.05). Results: All three factors, materials, dentin wetness and air drying time, showed significant effect on the microtensile bond strength. Clearfil $S^3$ Bond, dry dentin surface and 10 sec air drying time showed higher bond strength. Conclusions: Within the limitation of this experiment, air drying time after the application of the one-step self-etching adhesive agent was the most significant factor affecting the bond strength, followed by the material difference and dentin moisture before applying the adhesive agent.

피로크랙 진전수명의 확률특성에 관한 연구 II (A Study on the Probabilistic Nature of Fatigue Crack Propagation Life(II) -The Distribution of Crack Propagation Rate-)

  • 윤한용
    • 대한기계학회논문집
    • /
    • 제14권6호
    • /
    • pp.1561-1567
    • /
    • 1990
  • 본 연구에서는 고강도 알루미늄합금 A12024-T3재의 통계적시험에 의하여 시험 편두께가 피로크랙 진전속도의 분포에 미치는 영향을 밝히고자 하며, 또한, 통계적시 험의 능률화 및 일관성을 꾀하기 위하여 개발한 새로운 유형의 자동화 다단식 피로시 험기의 개략을 밝힌다.

Bio-film Composites Composed of Soy Protein Isolate and Silk Fiber: Effect of Concentration of Silk Fiber on Mechanical and Thermal Properties

  • Prabhakar, M.N.;Song, Jung Il
    • Composites Research
    • /
    • 제27권5호
    • /
    • pp.196-200
    • /
    • 2014
  • A novel, simple and totally recyclable method has been developed for the synthesis of nontoxic, biocompatible and biodegradable bio-composite films from soy protein and silk protein. Bio films are defined as flexible films prepared from biological materials such as protein. These materials have potential application in medical and food as a packaging material. Their use depends on various parameters such as mechanical (strength and modulus), thermal, among others. In this study, prepare and characterization of bio films made from Soy Protein Isolate (SPI) (matrix) and Silk Fiber (SF) (reinforcement) through solution casting method by the addition of plasticizer and crosslinking agent. The obtained SPI and SPI/SF composites were subsequently subjected to evaluate their mechanical and thermal properties by using Universal Testing Machine and Thermal Gravimetric Analyzer respectively. The tensile testing showed significant improvements in strength with increasing amount of SF content and the % elongation at break of the composites of the SPI/SF was lower than that of the matrix. Though the interfacial bonding was moderate, the improvement in tensile strength and modulus was attributed to the higher tensile properties of the silk fiber.

지르코니아 단일구조 전부도재관의 파절강도 (FRACTURE STRENGTH OF ZIRCONIA MONOLITHIC CROWNS)

  • 정희찬
    • 대한치과보철학회지
    • /
    • 제44권2호
    • /
    • pp.157-164
    • /
    • 2006
  • Purpose: The purpose of this study was to compare the fracture strength of the zirconia monolithic all-ceramic crowns according to the thickness(0.5 mm, 0.8 mm, 1.1 mm) and IPS Empress II ceramic crown of 1.5 mm thickness. Material and method: Eight crowns for each of 3 zirconia crown groups were fabricated using CAD/CAM system(Kavo, Germany) and eight Empress II crowns were made from silicone mold and wax pattern. Each crown group was finished in accordance with the specific manufacturer s instruction. All crowns were luted to the metal dies using resin cement and mounted on the testing jig in a universal testing machine. The load was directed at the center of crown with perpendicular to the long axis of each specimen until catastrophic failure occurred. Analysis of variance and Tukey multiple comparison test(p<.05) were applied to the data. Results and Conclusion: 1. The fracture strength of the zirconia monolithic all-ceramic crown was higher thickness increased(p<.05). 2 The fracture strength of 1.1 mm thickness zirconia monolithic all-ceramic crown was higher than the fracture strength of 1.5 mm thickness IPS Empress II crown(p<.05). 3. The fracture strength of 0.5 mm thickness zirconia monolithic all-ceramic crown exceeded maximum occlusal forces.

Assessment of 23 kV Capacitive Coupler for On-line Partial Discharge Measurements

  • Jeong, J.Y.;Kang, D.S.;Sun, J.H.;Heo, J.C.;Park, C.H.
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권1호
    • /
    • pp.123-130
    • /
    • 2009
  • The partial discharge (PD) measurement is a very effective method to assess the winding insulation condition of high-voltage machines, since most of the insulation failure processes are directly or indirectly caused by PD. On-line PD measurements, which can detect insulation defects of winding in the early stages on rotating machines in operation, have been accepted as the most important technique. The epoxy mica capacitive coupler is currently and extensively used for on-line detection of PD pulses of high-voltage rotating machines. To evaluate the feasibility of developing a capacitive coupler that is easier to manufacture at a lower cost compared to epoxy mica couplers, a 100pF capacitive coupler made of ceramic material is designed, fabricated and tested for on-line PD measurements of 23 kV electrical machines. A series of electrical tests and accelerated aging tests are performed on the ceramic coupler to evaluate the performance requirements, long-term reliability and thermal stability for in field application. The test results show that the newly developed ceramic coupler provides equal and improved performance at a lower cost compared to epoxy mica couplers, and estimated voltage life is anticipated to surpass 100 years.

강화재의 사용 방법이 복합 레진 인레이 브릿지의 파괴 강도에 미치는 영향 (The effect of reinforcing methods on fracture strength of composite inlay bridge)

  • 변창원;박상혁;박상진;최경규
    • Restorative Dentistry and Endodontics
    • /
    • 제32권2호
    • /
    • pp.111-120
    • /
    • 2007
  • 본 연구는 복합레진 인레이 브릿지에서 강화재의 표면 처리와 사용 방법이 파괴 강도에 미치는 영향을 평가하였다. 본 연구에서 사용한 강화재료는 I Beam, U Beam, 1 + U Beam이었으며, 표면처리 방법은 Silane, Sandblast, Hole형성 (U beam)이었다. 강화 재료의 구성과 표면 처리 방법에 따라 총 11개의 실험군을 설정하였다. 상악 인공치 모형에서 제2소구치의 발거 상태를 가정하고 복합레진 인레이 브릿지 제작을 위하여 인접한 제1소구치에 DO, 제1대구치에 MO 와동을 형성하였다. 와동이 형성된 인공치 모형을 고무 인상체를 이용하여 석고로 제작하고, 각 실험군 별로 강화재료와 강화 재료의 표면 처리 방법에 따라 Tescera ATL (BISCO Inc. IL, USA) 복합레진을 사용하여 복합레진 인레이 브릿지를 제작하였다 그 후 시편을 복제모형에 인산아연시멘트로 합착하고 Universal testing machine (EZ Test, Shimadzu, Japan)을 이용하여 flexural stress를 가하여 파괴 강도를 측정하였으며 95% 유의 수준에서 one-way ANOVA/ Scheffes post-hoc test를 시행하여 통계 분석하였다. 다음과 같은 결론을 얻을 수 있었다. 1. 내부 강화재 I beam을 사용한 실험군이 유의성 있게 높은 파괴 강도 값을 보였다 (P<0.05). 2. 표면 처리 방법에 따른 차이는 나타나지 않았다 (P>0.05). 3. 복합레진 인레이 브릿지의 파괴는 강화 재료를 사용 시에는 복합레진과 강화 재료간에 분리 파괴가 나타났으며 사용하지 않은 경우에는 수직파괴 경향이 나타났다. 4. U beam에 유지 hole을 형성한 경우 파괴 강도 증가를 시키지 않았다.