• Title/Summary/Keyword: Material testing

Search Result 2,020, Processing Time 0.021 seconds

J and CTOD Estimation for Homogeneous and Bi-Material Fracture Toughness Testing Specimens

  • Lee, Hyungyil;Kim, Yun-Jae
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.8
    • /
    • pp.1079-1089
    • /
    • 2001
  • This paper proposes J and CTOD estimation schemes applied to fracture toughness testing, covering typical homogeneous and bi-material specimens. Recommendations are based on the plastic limit analysis (either slip line field or finite element limit analyses), assuming the rigid plastic material behavior. The main outcome of the present study is that the J and CTOD estimation schemes (both codified and non-codified), recommended for homogeneous specimens, can be equally used for bi-material specimens with interface cracks. The effect of yield strength mismatch in bi-material specimens on the J-integral CTOD is discussed.

  • PDF

Data Reduction and Analysis Technique for the Resonant Column Testing by Its Theoretical Modeling (공진주 실험의 이론적 모델링에 의한 자료분석 및 해석기법의 제안)

  • 조성호;황선근;강태호;권병성
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.291-298
    • /
    • 2003
  • The resonant column testing is a laboratory testing method to determine the shear modulus and the material damping factor of soils. The method has been widely used for many applications and its importance has been increased. Since the establishment of the testing method in 1963, the low-technology electronic devices for testing and data acquisition have limited the measurement to the amplitude of the linear spectrum. The limitations of the testing method were also attributed to the assumption of the linear-elastic material in the theory of the resonant column testing and to the use of the wave equation for the dynamic response of the specimen. For the better theoretical formulation of the resonant column testing, this study derived the equation of motion and provided its solution. This study also proposed the improved data reduction and analysis method for the resonant column testing, based on the advanced data acquisition system and the proposed theoretical solution for the resonant column testing system. For the verification of the proposed data reduction and analysis method, the numerical simulation of the resonant column testing was performed by the finite element analysis. Also, a series of resonant column testing were peformed for Joomunjin sand, which verified the feasibility, of the proposed method and showed the limitations of the conventional data reduction and analysis method.

  • PDF

Fiber Orientation Determination of CFRP Composites using CODF Concept (CODF 개념을 이용한 CFRP 복합재료의 Fiber Orientation 측정기술연구)

  • Lee, S.S.;Ahn, B.Y.;Lee, J.R.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.10 no.2
    • /
    • pp.38-42
    • /
    • 1990
  • The specific strength of the fiber reinforced composite material is closely related to the anisotropy of the material. For the quantitative characterization of the anisotropy in the composite material, applied was CODF concept which was extensively used in the metallic material. As the results, the anisotropy of the material could be quantitatively analysed from the measurement of the phase velocities of the angular dependent $SH_o$ waves.

  • PDF

Temperature Distribution Monitoring of Transformer Using IRR-Camera (적외선방사카메라를 이용한 변압기 온도분포 모니터링)

  • 이우선;정찬문;서용진
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.459-462
    • /
    • 2002
  • The conventional thermal insulator and power transformer testing is widely used in surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also thermal testing is able to offer the standard judgement of relative degradation level of outside HV machine. There it is very useful method compare to previous conventional thermal testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, thermal testing of Power transformer is measured with partial temperature distribution in real time.

  • PDF

Temperature Distribution Monitoring of Transformer (변압기 온도 변화특성 모니터링)

  • Lee, Woo-Sun;Jung, Chan-Moon;Son, Dong-Min;Seo, Young-Jin;Lim, Jang-Sub
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.69-72
    • /
    • 2002
  • The conventional thermal insulator and power transformer testing is widely used in surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also thermal testing is able to offer the standard judgement of relative degradation level of outside HV machine. There it is very useful method compare to previous conventional thermal testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, thermal testing of power transformer is measured with partial temperature distribution in real time.

  • PDF

Study of Effectiveness of Antimicrobial on Restraining Formation of Biofilms on the Surface of Aluminum (항균제를 이용한 알루미늄 표면에 생물막 형성 억제효과 분석)

  • Park, SangJun;Oh, YoungHwan;Jo, BoYeon;Choi, MiYeon;Hyun, MinWoo;Jeong, JaeHyun;Kim, EuiYong
    • KSBB Journal
    • /
    • v.30 no.2
    • /
    • pp.69-76
    • /
    • 2015
  • The antibacterial activity of a antimicrobial (organic synthetic or organic natural material) on the bacteria (Bacillus megaterium, Arthrobacter oxydans, Micrococcus luteus, Methylobacterium aquaticum) detected in the automobiles showed 99.9% bacteria decrease rate within 30 min of being in contact with the tested bacteria culture. The MIC of the organic synthetic material based antimicrobials and the organic natural material based antimicrobial on the bacteria were 31~500 mg/mL and 8~250 mg/mL, respectively. The bacteria and biofilms were formed on the surface of aluminum after 5 ~8 days in the case of addition of the organic synthetic material based antimicrobial to the MIC values for the tested bacteria culture. On the other hand, there was no proliferation of bacteria and formation of biofilms on the surface of aluminum even after 30 days in the case of addition of the organic natural material based antimicrobial to the MIC values for the tested bacteria culture. As a result, the organic natural material based antimicrobial was confirmed to be more excellent effect of inhibition of bacterial proliferation and restraint of biofilms formation than the organic synthetic material based antimicrobial.

Effect of Al Alloy Composition on Physical and Crystallographical Properties of Plasma Electrolytic Oxidized Coatings I. Physical Properties of PEO Layer (플라즈마 전해 산화 코팅에 있어서 알루미늄 합금 모재 성분의 물리적, 결정학적 영향 I. PEO 층의 물성)

  • Kim, Bae-Yeon;Lee, Deuk-Yong;Kim, Yong-Nam;Jeon, Min-Seok;Song, Jun-Kwang;Kim, Sung-Youp;Kim, Kwang-Youp
    • Journal of the Korean Ceramic Society
    • /
    • v.47 no.3
    • /
    • pp.256-261
    • /
    • 2010
  • Physical properties of Plasma electrolytic oxidized 8 different types of Al alloys, A-1100, A-2024, A-5052, A-6061, A-6063, A-7075, ACD-7B and ACD-12 were investigated. The electrolyte for PEO was $Na_2SiO_3$ solutions with NaOH and some alkali earthen metal salts. Porous layer near the surface of PEO coating was not found, and surface roughness Ra50 was below 2.5 ${\mu}m$. Surface roughness was affected by growth rate of plasma electrolytic oxidized layer, not by Si content in Al alloy.

Effect of Al Alloy Composition on Physical and Crystallographical Properties of Plasma Electrolytic Oxidized Coatings II. Crystallographic Analysis of PEO Layer (플라즈마 전해 산화 코팅에 있어서 알루미늄 합금 모재 성분의 물리적, 결정학적 영향 II. PEO 층의 결정상 분석)

  • Kim, Bae-Yeon;Lee, Deuk-Yong;Shin, Min-Chul;Shin, Hyun-Gyoo;Kim, Byeong-Kon;Kim, Sung-Youp;Kim, Kwang-Youp
    • Journal of the Korean Ceramic Society
    • /
    • v.47 no.4
    • /
    • pp.283-289
    • /
    • 2010
  • Physical properties of Plasma electrolytic oxidized 8 different kinds of Al alloys, A-1100, A-2024, A-5052, A-6061, A-6063, A-7075, ACD-7B and ACD-12 were investigated. The electrolyte for PEO was $Na_2SiO_3$ and NaOH and some alkali earthen metal salts system solution. $\eta$-alumina, as well as $\gamma$-alumina, was main crystal phase, which were ever reported. Also, $Al_{4.95}Si_{1.05}O_{9.52}$ was found only in this research. So we can conclude that the process conditions of PEO apparatus and composition and concentration of its electrolyte affects crystal structure and physical properties of PEO layers much more than the compositions of Al alloy.

The Application of IRR-Camera for the Diagnosis of Surface Degradation (표면열화진단을 위한 적외선카메라의 응용)

  • Lim, Jang-Seob;Jeong, Seung-Chun;Lee, Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.61-65
    • /
    • 2001
  • The conventional tracking testing as IEC-60587 is widely used in surface aging measurement of outdoor insulator because those testing can carry out very short time in Lab-testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of outdoor HV machine/system. Therefore it is very useful method compare to previous conventional tracking testing method and effective Lab-testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, SD occurred from procelain insulator, used 22.9[KV] distribution, is measured with partial temperature distribution in real time, the degradation grade of SD is analyzed through produced patterns in SD concentration according to applied time.

  • PDF

The New Aging Diagnosis in IEC-60587 (IEC-60587의 새로운 열화진단)

  • Lim, Jang-Seob;Chung, Seung-Chun;Jeong, Jong-Cheol;Park, Gye-Choon;Lee, Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05b
    • /
    • pp.71-74
    • /
    • 2001
  • The conventional tracking testing as IEC-60587 is widely used In surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of outside HV machine. Therefore it is very useful method compare to previous conventional tracking testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IIR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, SD occurred from IEC-60587 is measured with partial temperature distribution in real time, the degradation grade of SD is analyzed through produced patterns in IEC-60587 according to applied time.

  • PDF