• Title/Summary/Keyword: Material separation

Search Result 824, Processing Time 0.029 seconds

A Study on the Gas-liquid Separation Effect of the Knockout Drum in the Flare System (플레어시스템에서 녹아웃드럼의 기·액 분리효과에 관한 연구)

  • Kwon, Hyun-Gil;Baek, Jong-Bae;Kim, Sang-Ryung
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.3
    • /
    • pp.1-8
    • /
    • 2021
  • Among the flare systems that handle discharged substances from safety valves, the knockout drum was a key facility for safety, but the installation standards were not clear, so it was necessary to review the standards acceptable to the workplace and regulatory agencies. After investigating the domestic and foreign technical standards of knockout drums and the deficiencies of previous studies, research was first conducted on the degree of mass discharge, the installation location of the intermediate knockout drum, and the effect of changes in the composition of the discharged material. As a result of the study under the process simulation conditions, the gas-liquid separation of the knockout drum was completed in a small amount of less than 7,500kg/hr. However, when more than that was released, the gas-liquid separation effect was small even with the addition of an intermediate knockout drum. In addition, when the composition ratio of the material easily condensed was increased (molar fraction 10%), the gas-liquid separation effect of the knockout drum increased in the case of mass release. The gas-liquid separation effect was analyzed to be greater when the knockout drum was installed adjacent to the stack than the knockout drum was installed adjacent to the process equipment.

1,3-Dioxolane-Based CO2 Selective Polymer Membranes for Gas Separation (1,3-Dioxolane 기반 CO2 선택성 고분자막의 개발)

  • Iqubal Hossain;Asmaul Husna;Ho Bum Park
    • Membrane Journal
    • /
    • v.33 no.3
    • /
    • pp.94-109
    • /
    • 2023
  • 1,3-Dioxolane is an exciting material that has attracted widespread interest in the chemical, paint, and pharmaceutical industries as a solvent, electrolyte, and reagent because 1,3-dioxolane is not toxic, carcinogenic, explosive, auto-flammable, and multifunctional, and due to their excellent miscibility in most organic and aqueous solvent conditions. Recently, this material has received increasing attention as a CO2-selective polymer precursor to separating CO2 from flue gas and natural gas mixtures. Poly(1,3-dioxolane) (PDXL) possesses higher ether oxygen content than polyethylene oxide (PEO), which demonstrates superior membrane CO2/N2 separation properties owing to their polar ether oxygen groups exhibiting strong affinity toward CO2. Thus, PDXL-based membranes displayed an outstanding CO2 solubility selectivity over non-polar (N2, H2, and CH4) gases. However, the polar groups of PDXL, like PEO, promote chain packing efficiency and cause polymer crystallization, thereby reducing its gas permeability, which should be improved. In this short review, we discuss the recent advancement and limitations of PDXL membranes in gas separation applications. To conclude, we provide future perspectives for inhibiting the limits of 1,3-dioxolane-based polymers in the CO2 separation process.

Effect of magnetic separation in removal of Cr and Ni from municipal solid waste incineration (MSWI) bottom ash (생활폐기물(生活廢棄物) 소각(燒却) 바닥재의 자력선별(磁力選別)에 따른 크롬과 니켈의 거동(擧動))

  • Ahn, Ji-Whan;Um, Nam-Il;Cho, Kye-Hong;Oh, Myung-Hwan;You, Kwang-Suk;Han, Gi-Chun;Cho, Hee-Chan;Han, Choon;Kim, Byong-Gon
    • Resources Recycling
    • /
    • v.16 no.6
    • /
    • pp.3-9
    • /
    • 2007
  • Although the ferrous material was separated by the magnetic separation before the incineration process, the municipal solid waste incineration bottom ash generated during incinerator in metropolitan area consists of many iron products which account for about $3{\sim}11%$ as well as ceramics and glasses. The formation of $NiFe_2O_4$ and $FeCr_2O_4$ with a $Fe_3O_4-Fe_2O_3$ (similar to pure Fe) on the surface of iron product was found during air-annealing in the incinerator at $1000^{\circ}C$, because Ni and Cr has a chemical attraction about iron is using to coat with Ni and Cr metals for poish or to prevent corrosion. Therefore, Fe-Ni Cr oxide can be formed on durface of the iron product and it can be separated from bottom ash through the magnetic separation. So, in this study, the separation ratio of heavy metals as magnetic separation and mineralogical formation of Fe-ion(heavy metal) in ferrous metals corroded were investigated. As the result, the separation ratio of Ni and Cr based on particle sizes accounted for about $45{\sim}50%$, and Cu and Pb accounted for below 20%. Also, the leaching concentration of Ni and Cr in bottom ash separated by magnetic separation was lower than that in fresh bottom ash.

Preparation and Application of Functional Carbon Whisker Membrane for Separation Process

  • Bae, Sang-Dae;Son, Hee-Jong;Jung, Chul-Woo
    • Journal of Environmental Science International
    • /
    • v.17 no.11
    • /
    • pp.1235-1241
    • /
    • 2008
  • Membrane separation is extensively used for water/wastewater treatment because of its efficiency separation processes. However, particles in the feed water can deposit and accumulate on the membrane surface to created cake layer. As a consequence, the selectivity of the membrane and flux through the membrane are decreased, which is called fouling/blocking phenomenon. In order to solve fouling problem, we developed a novel membrane named Carbon Whisker Membrane (CWM) which contains vapor-grown carbon fibers/whiskers on the surface of the membrane and a layer of carbon film coated on the ceramic substrate. We firstly employed polymethyl methacrylate (PMMA) as a testing material to investigate the fouling mechanism. The results suggested that Carbon Whiskers on the surface of the membrane can prevent the directly contact between the membrane body and particles so that the fouling/blocking could not occurred easily compared to the membrane without carbon whiskers. We also researched the relationship with the diameter, density of carbon whisker on the membrane surface and total flux of solutions. Finally, we will be able to control the diameter and density of carbon whiskers on the membrane and existence of carbon whiskers on the membrane, it is important factor, might be prevent fouling/blocking in the water treatment.

Development of High Pressure Membrane-Based Associated Gas Separation System for DME Synthesis (DME 합성을 위한 고압 유휴가스 분리용 Membrane 시스템 개발)

  • Kim, Hackeun;Bae, Myongwon;Lee, Sangjin;Ha, Seongyong;Lee, Chungseop;Mo, Yonggi
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.26 no.1
    • /
    • pp.45-53
    • /
    • 2015
  • The objective of this study is to develop a gas pro-treatment system for DME synthesis, wherein this system separates $CO_2$ from Flaring gas as Membrane, in order to save raw material ($CH_4$) cost of DME. In this study, hollow fiber membrane is developed, which is able to separate high-pressure gas, supported by polysulfone and coated with amorphous fluorinated polymer. Throughout the evaluation of the membrane's separation characteristics, the membrane is applied to this system. The membrane is designed by 2 stages for over 90% removal rate of $CO_2$ and over 90% recovery rate of $CH_4$. The bench scale of pro-treatment system is developed as $25Nm^3/hr$.

Selective leaching of valuable metals (Au, Ag etc.) from waste printed circuit boards (PCB)

  • Oh, Chi-Jung;Lee, Sung-Oh;Song, Jin-Kon;Kook, Nam-Pyo;Kim, Myong-Jun
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.193-197
    • /
    • 2001
  • This study was carried out to recover gold, silver and other valuable metals from the printed circuit boards (PCB) of waste computers. PCB samples were crushed to under 1mm by a shredder and initially separated into 30% conducting and 70% non-conducting materials by an electrostatic separator. The conducting materials, which contained the valuable metals, were then used as the feed material for magnetic separation where it was found that 42% was magnetic and 58% non- magnetic. The non-magnetic materials contained 0.227mg/g Au and 0.697mg/g Ag. Further leaching of the non-magnetic component using 2.0M sulfuric acid and 0.2M hydrogen peroxide at 85$^{\circ}C$ extracted more than 95% copper, iron, zinc, nickel and aluminium. Au and Ag were not extracted in this solution, however, more than 95% of Au and 100% of Ag were selectively leached with a mixed solvent (0.2M ammonium thiosulfate, 0.02M copper sulfate, 0.4M ammonium hydroxide). Finally, the residues were reacted with a NaCl solution to leach out Pb while sulfuric acid was used to leach out Sn. Recoveries reached 95% and 98% in solution, respectively.

  • PDF

Performance Test of Silicone Rubber Membrane by Gas Permeation Method (기체투과에 의한 Silicone Rubber Membrane의 기능성 시험)

  • Lee, Seung-Bum;Hong, In-Kwan
    • Elastomers and Composites
    • /
    • v.33 no.1
    • /
    • pp.37-43
    • /
    • 1998
  • The permeation of gas through polymer membrane at temperatures above its glass transition, generally occurs by a solution-diffusion mechanism. This mechanism is performed by the affinity difference between polymeric materials and gas molecules, and various technologies, such as copolymerization, impregnation and so on, have been researched to improve the affinity of polymeric material for the gases. In this study, permeability and selectivity for some gases were obtained from steady-state rates of gas permeation through silicone rubber membrane which is prepared by supercritical fluid extraction method. The permeability was measured by the volumetric method proposed by Barrer. Permeability was increased generally with temperature and permeation pressure. Silicone rubber membrane shows a higher permeability to $CO_2$ than to $O_2$, $N_2$. This results probably reflect the relatively high solubility of CO_2 in silicone rubber membrane, which is due to the affinity of $CO_2$ molecules. Since separation powers of $CO_2/N_2$, $CO_2/O_2$ were more than 200, and 100, respectively, it is able to separate $CO_2$ from the air, and the optimum temperature and pres-sure was 328.15 K, 60 cmHg respectively. In future, it is possible that the silicone rubber membrane can be used for separation or concentration of $CO_2$ through experiment for mixed gas separation.

  • PDF

Study on the separation of large ionic-molecules by electrofiltration (전기여과에 의한 거대이온성 분자체 분리현상연구)

  • Park Young-Gyu
    • Journal of the Korean Electrochemical Society
    • /
    • v.1 no.1
    • /
    • pp.18-23
    • /
    • 1998
  • Theoretical model has been derived in the electrophoretic separation system where an electric potential is applied to the system in the axial direction. The effect of electrophoretic convection in the polymeric media is significantly contributed to separate large ionic-molecules because the conformation of large ionic-molecule quickly orients in the field direction. The dependence of the transport in the polymeric media upon field intensity and molecular size aids in understanding the transport of large ionic-molecule in the system, since the convective velocity of large ionic-molecule is accelerated inside a porous material. The separation of two different large ionic-molecules is predicted with a value of $(Pe_t/Pe_g)$ of individual large ionic-molecule using an operator and the reptation theories.

Magnetic Particle Separation by an Optimized Coil: A Graphical User Interface

  • Rouhi, Kasra;Hajiaghajani, Amirhossein;Abdolali, Ali
    • Journal of Magnetics
    • /
    • v.22 no.2
    • /
    • pp.214-219
    • /
    • 2017
  • Magnetic separators that clean the fluid stream from impurities, protect the installations in numerous industries. This paper introduces a graphical user interface (GUI) which proposes an optimized coil separating magnetic particles with a radius from 1 up to 500 µm. High gradient magnetic fields are employed in an arbitrary user defined fluidic channel which is made of a nonmetallic material. The effects of coil parameters are studied and adjusted to design an optimum coil with a minimum Ohmic loss. In addition, to design the coil scheme based on the particle movements, a mathematical particle-tracing model within the fluid channels has been utilized. In comparison to conventional magnetic separators, this model is reconfigurable by the user, produces a weaker magnetic field, allows for continuous purifying and is easy to install, with high separation efficiency. The presented GUI is simple to use, where the coil's manufacturing limitations can be specified.

Separation of Light Rare Earth Elements by Solvent Extraction with a Mixture of Cationic and Tertiary Amine (양이온 추출제와 아민의 혼합추출제에 의한 경희토류금속의 분리)

  • Lee, Man-Seung;Son, Seong Ho
    • Resources Recycling
    • /
    • v.26 no.2
    • /
    • pp.3-10
    • /
    • 2017
  • Rare earth elements with high purity are demanded for the manufacture of advanced materials. Light rare earth elements are contained in domestic monazite and Ni-MH batteries. In this paper, solvent extraction to separate the light rare earth elements from hydrochloric acid leaching solutions of these resources was discussed. A mixture of cationic and tertiary amine shows synergistic effect on the extraction of LREEs and the extent of pH decrease during extraction is reduced. The effect of solution pH on the extraction and synergism was reviewed. Acquisition of the operation data with mixer-settler on the separation of LREEs by this mixture is necessary to develop a process.