• Title/Summary/Keyword: Material and Contamination

Search Result 450, Processing Time 0.029 seconds

Contamination measurement, Analysis & Control for Satellite (인공위성의 오염 측정, 분석 및 관리)

  • Lee, Sang-Hoon;Hong, Seok-Jong;Cho, Hyok-Jin;Seo, Hee-Jun;Moon, Guee-Won
    • Aerospace Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.116-122
    • /
    • 2010
  • It is necessary to be careful about contamination control to minimize the accumulation of the contamination material on satellite surface during the I&T phase. In the space environment which characterized by high vacuum, high and very low temperature, contamination material causes satellite to lose its own performance. Especially, contamination material can accumulate on critical surfaces such as lenses, mirrors, and sensors. KARI(Korea Aerospace Research Institute) conducts the clean room to control and minimize the contamination effect. This paper introduces the principle of contamination and the method of measure and analysis for the contamination.

A Estimation of Contamination Degree by the Measurement of Phase Difference on the Outdoor Insulator (옥외절연물의 오손도 파악을 위한 위상차 측정)

  • 심규일;이원영;한상옥;박강식
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.443-446
    • /
    • 2002
  • In this paper, a phase difference of liveline insulator was measured and analyzed to estimate the contamination degree. The probability of accident rises according to the increase of the contamination. So the estimation of contamination degree is very important in design and maintenance of outdoor insulator. There are many methods to measure the contamination degree, but those methods use the spacial sense to measure the contamination degree. So, we have no information about the contamination from the liveline insulator, but there is a measurement of phase difference to estimate the contamination degree. The phase difference is varied with the increase of ESDD, so the contamination degree could be estimated by using those characteristics. The experiment is performed to analyze the interrelationship between contamination degree and phase difference. The variable condition is relative humidity that increases from 30 to 100 % in a chamber. We use the DAS program to measure and analyze the data. From the result, the variation of phase difference is different by the contamination degree, so we can confirm the possibility of estimating the contamination degree by the phase difference.

  • PDF

Automatic Measurement of the Degree of Contamination with Electric Conductivity and Oscillating Frequency (발진주파수 및 전도도를 통한 오손도 자동측정)

  • 최남호;구경완;이명섭;한상옥;정재기
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.153-156
    • /
    • 2000
  • To reduce the maintenance expense, and the possibility of electric outage and accident, we should optimize the outdoor insulation system. And for the optimization, accurate measurement for the degree of contamination with climatic conditions, such as wind, rain, and drought, should be carried. However the classical measuring method, brush wiping, has some problems in the aspect of man power, reliability, and expense. In this paper, we propose two type apparatus, which could detect the degree of contamination on insulators in outdoor insulation system, such as transmission and distribution line insulator and bushing. One use the leakage current, and the other use the oscillating frequency to check the degree of contamination. To avoid the oxidation of electrode AC source, and the low degree of contamination was applied. From the result of this investigation we could get the good relationship between the degree of contamination and the leakage current and oscillating frequency

  • PDF

The Ingredient and the Properties of Contaminants (염진해 오손물질의 성분 및 특성)

  • 최남호;박강식;조성배;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.51-54
    • /
    • 1999
  • In this paper, the relativities, and the properties of various contaminants, which could give significant decrease in electrical insulation strength were investigated. For this investigation, the contamination degree was manually measured with brush-wiping method, and the ingredient of some specific sample was analyzed with ICP/MS. With the result, the influence of distance from sea, climatic condition contamination was investigated. And the difference in electrical properties of various salts in aquous solution was determined. Finally, we could get several significant result on the relativity and properties of contamination in various conditions

  • PDF

The Distribution of Salt Contamination with the Influence of Geographical Condition (지리적 영향에 따른 염해 오손물질의 분포에 관한 연구)

  • 최남호;국연호;조성인;박강식;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.695-698
    • /
    • 2000
  • This paper present the result of the investigation, the distribution of salt contamination with the influence of geographical condition. To get the ESDD data, a conventional brush washing method was adapted, and IC(ion chromatography) was used to measure the quantity of anions, such as Cl$\^$-/ and SO$_4$$\^$2-/. And we make an analysis on the distribution of salt contamination with the increase of distance from shore. With 10 month ESDD data, we seek the 95% ESDD value with interpolation method. With these analyses, we had obtained the formulation concerned with the distance from sea. And could know the composition of contamination.

  • PDF

The prediction of contamination degree through the relationship analysis between the climatic factor and ESDD (기후인자와 ESDD간의 상관관계 분석통한 오손도 예측)

  • Lee, W.Y.;Kim, D.Y.;Park, H.S.;Han, S.O.;Park, K.S.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.440-443
    • /
    • 2003
  • Recently, with the rapid growth of industry, environmental condition became worse. With the mix of the various contaminants, such as, salts, dust and industrial pollutants, synergy effect could be happened. So, many researches have been focused on the issue. The cause of natural accident could be classified as, lightning, rainstorm and contamination. However, the accident by contamination influences on the larger area than that by lightning, and, in the case of rapid contamination, it takes a shorter time than rainstorm. The salt contaminant is one of the most representative pollutants, and known as the main source of the accident by contamination. So, in this investigation we make a research on the prediction of contamination degree through the relationship analysis between the climatic factor and ESDD.

  • PDF

A Detection of Salt Contamination on the Transmission Line Insulator Using Conductivity Sensor (전도도 센서를 이용한 송전선용 애자의 염분량 검출)

  • Kang, Y.W.;Shim, E.B.;Kweon, D.J.;Kwak, J.S.;Jung, C.S.;Lee, O.B.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.189-193
    • /
    • 2002
  • Outage caused by contaminated insulator on high voltage transmission line and in substation is major concern for utility world-wide. To prevent these outages, it is necessary to develop an automatic salt contamination detecting device which provide the information about contamination level on utility for engineer to meet the emergency in advance. For that purpose, we have been developing an automatic salt contamination detecting device to monitor a salt amount on operating power utility area. In the salt contamination detecting device development, the most important thing is the sensor which can detect a salt amount and the understanding of sensor' s detecting principle. This paper describes the operating principle of the sensor and the experimental results about the detecting of salt amount. The results of this experiment wi1l be useful for detecting the contamination level.

  • PDF

Technical Approaches for Assessment of Ground Water Contamination with TCE in an Industrial Area

  • Jeon, Kweonho;Yu, Soonyoung;Jeong, Jangsik;Son, Yanglae
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.10a
    • /
    • pp.70-86
    • /
    • 2003
  • Despite its usability, TCE has been managed as a hazardous material due to the toxicity and many contamination cases were surveyed in some developed countries. U.S.EPA(Kram et al., 2001) suggested DNAPL characterization methods and approaches based on survey experiences at several sites. However, Korea has not the least assessment of contamination and trial of remediation, although there are a lot of doubtable areas where ground water would be contaminated with TCE. In this study, we try to assess the volume and extent of ground water contamination with TCE and delineate the contamination source zones in an industrial area. Ground water in this area flows through fractures and the contaminant TCE has the properties of high volatility, high density and low partitioning to soil material. Thus, we applied a variety of technical approaches to identify the contamination status; documentary, hydrogeochemical, hydrogeological and geological surveys. In addition, additional survey was performed based on the interim findings, which showed that ground water contamination was limited to the relatively small area with high concentrations to the deep place. The contamination source zone is estimated to be the asphalt test institute where a great deal of TCE has been used to analyze the amount of asphalt soluble in TCE since 1984. Based on the contamination characterization and a myriad of documents about ground water remediation, appropriate site remediation management options will be recommended later. This study is now under way and this paper was focused on describing the technical approaches used to achieve the goals of this study.

  • PDF

The Effect of the Wind Direction and Velocity on the Salt Contamination of the Distribution Facilities (풍향 및 풍속이 배전설비의 염분오손에 미치는 영향)

  • Kim, Chan-Young;Kim, Dong-Myung;Kwon, Tae-Ho;Chun, Sung-Nam
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.499-500
    • /
    • 2006
  • The salt contamination on the distribution facilities was investigated with the wind direction and velocity. Most previous researches were concentrated on the measurement of The Equivalent Salt Deposit Density(ESDD) without environmental consideration. The wind direction and velocity of the many environmental conditions are the most important factors to analyze salt contamination. Pohang area which is located on the south and east of the Korean Peninsula was chosen to do this research. This research will present the result of ESDD depending on the wind direction and velocity.

  • PDF

A Study on Measurement of ESDD and Contamination Performance of Polymeric Outdoor Insulators (옥외용 절연체 표면에서의 ESDD 측정과 내오손특성에 관한 연구)

  • 연복희;유형철;이현진;송정용;이태호;허창수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.427-430
    • /
    • 2002
  • This paper presents on contamination performance of polymeric outdoor insulator with different contaminant accumulation. The ESDD (equivalent salt deposit density), tracking resistance and clean-fog test were performed to investigate the characteristics of contamination performance on polymeric outdoor insulator. Furthermore, we evaluated together with the porcelain samples for its comparison. It is found that ESDD of polymeric and porcelain insulator depends on the installation position. This surface accumulation of contaminant lead to the loss of surface hydrophobicity, expecially upper shed part of polymeric insulator. In addition, the effect of an artificial contaminant on the tracking resistance by inclined-plane method and leakage suppression ability under clean fog was surveyed. The time of tracking failure did not appear to change significantly with a much contaminant accumulation, while leakage current under clean-fog increased.

  • PDF