• Title/Summary/Keyword: Material Flow

Search Result 3,371, Processing Time 0.036 seconds

Study on the Consequence Effect Analysis & Process Hazard Review at Gas Release from Hydrogen Fluoride Storage Tank (최근 불산 저장탱크에서의 가스 누출시 공정위험 및 결과영향 분석)

  • Ko, JaeSun
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.4
    • /
    • pp.449-461
    • /
    • 2013
  • As the hydrofluoric acid leak in Gumi-si, Gyeongsangbuk-do or hydrochloric acid leak in Ulsan, Gyeongsangnam-do demonstrated, chemical related accidents are mostly caused by large amounts of volatile toxic substances leaking due to the damages of storage tank or pipe lines of transporter. Safety assessment is the most important concern because such toxic material accidents cause human and material damages to the environment and atmosphere of the surrounding area. Therefore, in this study, a hydrofluoric acid leaked from a storage tank was selected as the study example to simulate the leaked substance diffusing into the atmosphere and result analysis was performed through the numerical Analysis and diffusion simulation of ALOHA(Areal Location of Hazardous Atmospheres). the results of a qualitative evaluation of HAZOP (Hazard Operability)was looked at to find that the flange leak, operation delay due to leakage of the valve and the hose, and toxic gas leak were danger factors. Possibility of fire from temperature, pressure and corrosion, nitrogen supply overpressure and toxic leak from internal corrosion of tank or pipe joints were also found to be high. ALOHA resulting effects were a little different depending on the input data of Dense Gas Model, however, the wind direction and speed, rather than atmospheric stability, played bigger role. Higher wind speed affected the diffusion of contaminant. In term of the diffusion concentration, both liquid and gas leaks resulted in almost the same $LC_{50}$ and ALOHA AEGL-3(Acute Exposure Guidline Level) values. Each scenarios showed almost identical results in ALOHA model. Therefore, a buffer distance of toxic gas can be determined by comparing the numerical analysis and the diffusion concentration to the IDLH(Immediately Dangerous to Life and Health). Such study will help perform the risk assessment of toxic leak more efficiently and be utilized in establishing community emergency response system properly.

Analytical Validation of Rosmarinic Acid in Water Extract of Perilla frutescens Britton var. acuta Kudo as Functional Health Ingredient (건강기능식품 기능성 원료로써 장흥 차조기 열수 추출물의 지표성분인 로즈마린산 분석법 검증)

  • Park, Sung-Yong;Kim, Jung-Eun;Choi, Chul-Yung;Lee, Dong-Wook;Kim, Ki-Man;Yoon, Goo;Yoon, In-Su;Moon, Hong-Seop;Cho, Seung-Sik
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.1
    • /
    • pp.85-88
    • /
    • 2015
  • This study attempted to establish an HPLC analysis method for determination of marker compounds as a part of material standardization for the development of health functional food materials from Perilla frutescens Britton var. acuta Kudo. The quantitative determination method of rosmarinic acid as a marker compound of P. frutescens Britton var. acuta Kudo extract (PFE) was optimized by HPLC analysis using a C18 column ($4.6{\times}150mm$, $5{\mu}m$) with 0.1% acetic acid as the elution gradient and methanol as the mobile phase at a flow rate of 1 mL/min and detection wavelength of 280 nm. The HPLC/UV method was applied successfully to quantification of the marker compound in PFE after validation of the method with linearity, accuracy, and precision. The method showed high linearity in the calibration curve at a coefficient of correlation ($R^2$) of 0.9995, and the limit of detection and limit of quantitation were $0.36{\mu}g/mL$ and $1.2{\mu}g/mL$, respectively. Relative standard deviation (RSD) values of data from intra- and inter-day precision were less than 3.21% and 1.43%, respectively. Recovery rate test at rosmarinic acid concentrations of 12.5, 25 and $50{\mu}g/mL$ scored between 97.04~98.98% with RSD values from 0.25~1.97%. These results indicate that the established HPLC method is very useful for the determination of marker compound in PFE to develop a health functional material.

Study on the Lubricity Characteristics of Bio-heavy Oil for Power Generation by Various feedstocks (다양한 원료에 따른 발전용 바이오중유의 윤활 특성 연구)

  • Kim, Jae-Kon;Jang, Eun-Jung;Jeon, Cheol-Hwan;Hwang, In-Ha;Na, Byung-Ki
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.4
    • /
    • pp.985-994
    • /
    • 2018
  • Bio-heavy oil for power generation is a product made by mixing animal fat, vegetable oil and fatty acid methyl ester or its residues and is being used as steam heavy fuel(B-C) for power generation in Korea. However, if the fuel supply system of the fuel pump, the flow pump, the injector, etc., which is transferred to the boiler of the generator due to the composition of the raw material of the bio-heavy oi, causes abrasive wear, it can cause serious damage. Therefore, this study evaluates the fuel characteristics and lubricity properties of various raw materials of bio-heavy oil for power generation, and suggests fuel composition of biofuel for power generation to reduce frictional wear of generator. The average value of lubricity (HFRR abrasion) for bio-heavy oil feedstocks for power generation is $137{\mu}m$, and it varies from $60{\mu}m$ to $214{\mu}m$ depending on the raw materials. The order of lubricity is Oleo pitch> BD pitch> CNSL> Animal fat> RBDPO> PAO> Dark oil> Food waste oil. The average lubricity for the five bio-heavy oil samples is $151{\mu}m$ and the distribution is $101{\mu}m$ to $185{\mu}m$. The order of lubricity is Fuel 1> Fuel 3> Fuel 4> Fuel 2> Fuel 5. Bio-heavy oil samples (average $151{\mu}m$) show lower lubricity than heavy oil C ($128{\mu}m$). It is believed that bio-heavy oil for power generation is composed of fatty acid material, which is lower in paraffin and aromatics content than heavy oil(B-C) and has a low viscosity and high acid value, resulting in inhibition of the formation of lubricating film by acidic component. Therefore, in order to reduce friction and abrasion, it is expected to increase the lubrication of fuel when it contains more than 60% Oleo pitch and BD pitch as raw materials of bio-heavy oil for power generation.

A review on the design requirement of temperature in high-level nuclear waste disposal system: based on bentonite buffer (고준위폐기물처분시스템 설계 제한온도 설정에 관한 기술현황 분석: 벤토나이트 완충재를 중심으로)

  • Kim, Jin-Seop;Cho, Won-Jin;Park, Seunghun;Kim, Geon-Young;Baik, Min-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.5
    • /
    • pp.587-609
    • /
    • 2019
  • Short-and long-term stabilities of bentonite, favored material as buffer in geological repositories for high-level waste were reviewed in this paper in addition to alternative design concepts of buffer to mitigate the thermal load from decay heat of SF (Spent Fuel) and further increase the disposal efficiency. It is generally reported that the irreversible changes in structure, hydraulic behavior, and swelling capacity are produced due to temperature increase and vapor flow between $150{\sim}250^{\circ}C$. Provided that the maximum temperature of bentonite is less than $150^{\circ}C$, however, the effects of temperature on the material, structural, and mineralogical stability seems to be minor. The maximum temperature in disposal system will constrain and determine the amount of waste to be disposed per unit area and be regarded as an important design parameter influencing the availability of disposal site. Thus, it is necessary to identify the effects of high temperature on the performance of buffer and allow for the thermal constraint greater than $100^{\circ}C$. In addition, the development of high-performance EBS (Engineered Barrier System) such as composite bentonite buffer mixed with graphite or silica and multi-layered buffer (i.e., highly thermal-conductive layer or insulating layer) should be taken into account to enhance the disposal efficiency in parallel with the development of multilayer repository. This will contribute to increase of reliability and securing the acceptance of the people with regard to a high-level waste disposal.

A study on inspection methods for waste treatment facilities(I): Derivation of impact factor and mass·energy balance in waste treatment facilities (폐기물처리시설의 세부검사방법 마련연구(I): 공정별 주요인자 도출 및 물질·에너지수지 산정)

  • Pul-Eip Lee;Eunhye Kwon;Jun-Ik Son;Jun-Gu Kang;Taewan Jeon;Dong-Jin Lee
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.31 no.1
    • /
    • pp.69-84
    • /
    • 2023
  • Despite the continuous installation and regular inspection of waste treatment facilities, complaints about excessive incineration and illegal dumping stench continue to occur at on-site treatment facilities. In addition, field surveys were conducted on the waste treatment facilities currently in operation (6 type) to understand the waste treatment process for each field, to grasp the main operating factors applied to the inspection. In addition, we calculated the material·energy balance for each main process and confirmed the proper operation of the waste disposal facility. As a result of the site survey, in the case of heat treatment facilities such as incineration, cement kilns, and incineration heat recovery facilities, the main factors are maintenance of the temperature of the incinerator required for incineration and treatment of the generated air pollutants, and in the case of landfill facilities Retaining wall stability, closed landfill leachate and emission control emerged as major factors. In the case of sterilization and crushing facilities, the most important factor is whether or not sterilization is possible (apobacterium inspection).In the case of food distribution waste treatment facilities, retention time and odor control during fermentation (digestion, decomposed) are major factors. Calculation results of material balance and energy resin for each waste treatment facility In the case of incineration facilities, it was confirmed that the amount of flooring materials generated is about 14 % and the amount of scattering materials is about 3 % of the amount of waste input, and that the facility is being operated properly. In addition, among foodwaste facilities, in the case of an anaerobic digestion facility, the amount of biogas generated relative to the amount of inflow is about 17 %, and the biogas conversion efficiency is about 81 %, in the case of composting facility, about 11 % composting of the inflow waste was produced, and it was comfirmend that all were properly operated. As a result, in order to improve the inspection method for waste treatment facilities, it is necessary not only to accumulate quantitative standards for detailed inspection methods, but also to collect operational data for one year at the time of regular inspections of each facility, Grasping the flow and judging whether or not the treatment facility is properly operated. It is then determined that the operation and management efficiency of the treatment facility will increase.

The formal and intrinsic characteristics of the Changgeuk album (1971) and the meaning of the material (음반 창극 <사명대사>(1971)의 형식적·내용적 특징과 자료의 의미)

  • Song, So-Ra
    • (The) Research of the performance art and culture
    • /
    • no.39
    • /
    • pp.457-507
    • /
    • 2019
  • The purpose of this study is to explore the formal and content features of the material for the Changgeuk album , which was produced and released in 1971. Changgeuk album was produced and published as a headword for "Changgeuk". However, it differs from the style of Changgeuk which is treated as a stage drama in that the narrative is developed around the commentary and dialogue in the formal aspect and the Pansori is only partially used. The styles of Changgeuk, implemented through gramophone record, radio broadcasts and television broadcasts, varied widely, unlike those of Changgeuk established in the 1930s. Pansori music wasn't the only center, and traditional performers weren't even the main members of the play. The characteristic form of the Changgeuk album is an experiment of Changgeuk that emerged naturally with radio reading and the advent of radio dramas in the 1950s and 1960s. So it is necessary to pay attention to the Changgeuk album in that it shows diverse forms of experiments conducted by Changgeuk in the newly introduced culture and media in the middle and late 20th century As for the contents of the Changgeuk album , the work embraces Lee Jong ik 's novel (1957), but develops the narrative centering on the life of Saint Sa-myung(四溟大師). And it is faithfully portraying the life of a Buddhist monk and the national salvation hero who pursued the original work. This content composition can be understood in the will of singer Lee Yong bae, the soundman who produced the album, and in the flow of historical dramas that summon the historical hero of the old country of the time to the stage. Singer Lee Yong bae reflects on his life in the past when he was full of greed and conceit through his life as a monk of Saint Sa-myung(四溟大師) and is greatly impressed by the personal aspect of Saint Sa-myung(四溟大師), and these emotions encouraged his creative will. Also, the Changgeuk record is meaningful in that it is one of the specific materials that embodies the national hero as a record and a traditional play under the discourse of the people, the nation in the 1970s.

Steroid Effect on the Brain Protection During OPen Heart Surgery Using Hypothermic Circulatory Arrest in the Rabbit Cardiopulmonary bypass Model (저체온순환정지법을 이용한 개심술시 스테로이드의 뇌보호 효과 - 토끼를 이용한 심폐바이패스 실험모델에서 -)

  • Kim, Won-Gon;Lim, Cheong;Moon, Hyun-Jong;Chun, Eui-Kyung;Chi, Je-Geun;Won, Tae-Hee;Lee, Young-Tak;Chee, Hyun-Keun;Kim, Jun-Woo
    • Journal of Chest Surgery
    • /
    • v.30 no.5
    • /
    • pp.471-478
    • /
    • 1997
  • Introduction: The use of rabbits as a cardiopulmonary bypass(CPB) animal model is extremely dif%cult mainly due to technical problems. On the other hand, deep hypothermic circulatory arrest(CA) is used to facilitate surgical repair in a variety of cardiac diseases. Although steroids are generally known to be effective in the treatment of cerebral edema, the protective effects of steroids on the brain during CA are not conclusively established. Objectives of this study are twofold: the establishment of CPB technique in rabbits and the evaluation of preventive effect of steroid on the development of brain edema during CA. Material '||'&'||' Methods: Fifteen New Zealan white rabbits(average body weight 3.5kg) were divided into three experimental groups; control CA group(n=5), CA with Trendelenberg position group(n=5), and CA with Trendelenberg position + steroid(methylprednisolone 30 mglkg) administration group(n=5). After anesthetic induction and tracheostomy, a median sternotomy was performed. An aortic cannula(3.3mm) and a venous ncannula(14 Fr) were inserted, respectively in the ascending aorta and the right atrium. The CPB circuit consisted of a roller pump and a bubble oxygenator. Priming volume of the circuit was approximately 450m1 with 120" 150ml of blood. CPB was initiated at a flow rate of 80~85ml/kg/min, Ten min after the start of CPB, CA was established with duration of 40min at $20^{\circ}C$ of rectal temperature. After CA, CPB was restarted with 20min period of rewarming. Ten min after weaning, the animal was sacrif;cod. One-to-2g portions of the following tissues were rapidly d:ssected and water contents were examined and compared among gr ups: brain, cervical spinal cord, kidney, duodenum, lung, heart, liver, spleen, pancreas. stomach. Statistical significances were analyzed by Kruskal-Wallis nonparametric test. Results: CPB with CA was successfully performed in all cases. Flow rate of 60-100 mlfkgfmin was able to be maintained throughout CPB. During CPB, no significant metabolic acidosis was detected and aortic pressure ranged between 35-55 mmHg. After weaning from CPB, all hearts resumed normal beating spontaneously. There were no statistically significant differences in the water contents of tissues including brain among the three experimental groups. Conclusion: These results indicate (1) CPB can be reliably administered in rabbits if proper technique is used, (2) the effect of steroid on the protection of brain edema related to Trendelenburg position during CA is not established within the scope of this experiment.

  • PDF

The Clinical Effects of Normocapnia and Hypercapnia on Cerebral Oxygen Metabolism in Cardiopulmonary Bypass (체외순환 시 뇌대사에 대한 정상 탄산분압과 고 탄산분압의 임상적 영향에 관한 비교연구)

  • 김성룡;최석철;최국렬;박상섭;최강주;윤영철;전희재;이양행;황윤호
    • Journal of Chest Surgery
    • /
    • v.35 no.10
    • /
    • pp.712-723
    • /
    • 2002
  • Substantial alterations in cerebral blood flow(CBF) are known to occur during cardiopulmonary bypass(CPB). Many investigators have speculated that these changes may be responsible for both minor and major cerebral damages after CPB. More recently, these changes in CBF have been observed to be intimately related to the arterial carbon dioxide tension(Pa$CO_2$) maintained during CPB. The present study was prospectively designed to investigate the clinical effects of normocapnic and hypercapnic CPB on the cerebral oxygen metabolism in cardiac surgery Material and Method: Thirty-six adult patients scheduled for elective cardiac surgery were randomized to either normocapnic group (Pa$CO_2$35~40 mmHg, n=18) or hypercapnic group(Pa$CO_2$, 45~55 mmHg, n=18) with moderately hypothermic nonpulsatile CPB(nasopharyngeal temperature of 29~3$0^{\circ}C$). In each patient, middle cerebral artery blood flow velocity( $V_{MCA}$), cerebral arteriovenous oxygen content difference (C(a-v) $O_2$), cerebral oxygen extraction(COE), cerebral metabolic rate for oxygen(CMR $O_2$), cerebral oxygen transport( $T_{E}$ $O_2$), $T_{E}$ $O_2$/CMR $O_2$ ratio, cerebral desaturation(internal jugular bulb blood oxygen saturation $\leq$ 50%), and arterial and jugular bulb blood gas were evaluated throughout the operation. Postoperative neuropsychologic complications were assessed in all patients. All variables were compared between the two groups. Result: VMCA(169.13 $\pm$ 8.32 vs 153.11 $\pm$8.98%), TE $O_2$(1,911.17$\pm$250.14 vs 1,757.40$\pm$249.56), $T_{E}$ $O_2$,/CMR $O_2$ ratio(287.38$\pm$28.051 vs 246.77$\pm$25.84), $O_2$ tension in internal jugular bulb (41.66$\pm$9.19 vs 31.50$\pm$6.09 mmHg), and $O_2$saturation in internal jugular bulb(68.97$\pm$10.96 vs 58.12$\pm$12.11%) during CPB were significantly lower in normocapnic group(p=0.03), whereas hypercapnic group had lower C(a-v) $O_2$(3.9$\pm$0.3 vs 4.9$\pm$0.3 mL/dL), COE(0.3$\pm$0.03 vs 0.4$\pm$0.03), CMR $O_2$(5.8 $\pm$0.5 vs 6.8$\pm$0.6), and arterial blood pH(7.36$\pm$0.09 vs 7.46$\pm$0.07, p=0.04) during CPB. Hypercapnic group had lower incidence of cerebral desaturation than normocapnic group(3 vs 9 patients, p=0.03). Duration of the neuropsychologic complication(delirium) were shorter in hypercapnic group than in normocapnic group(36 vs 60 hrs, p=0.009). Conclusion: These findings suggest that hypercapnic CPB may have salutary effects on the cerebral oxygen metabolism and postoperative neurologic outcomes in cardiac surgery.surgery.

The Experimental Study for Myocardial Preservation Effect of Ischemic Preconditioning (허혈성 전조건화 유발이 심근보호에 미치는 영향에 관한 실험적 연구)

  • 이종국;박일환;이상헌
    • Journal of Chest Surgery
    • /
    • v.37 no.2
    • /
    • pp.119-130
    • /
    • 2004
  • Decrease in cardiac function after open heart surgery is due to an ischemia induced myocardial damage during surgery, and ischemic preconditioning, a condition in which the myocardial damage does not accumulate after repeated episodes of ischemia but protects itself from damage after prolonged ischemia due to myocytes tolerating the ischemia, is known to diminish myocardial damage, which also helps the recovery of myocardium after reperfusion, and decreases incidences of arrythmia. Our study is performed to display the ischemic preconditioning and show the myocardial protective effect by applying cardioplegic solution to the heart removed from rat. Material and Method: Sprague-Dawley male rats were used, They were fixed on a modified isolated working heart model after cannulation. The reperfusion process was according to non-working and working heart methods and the working method was executed for 20 minutes in which the heart rate, aortic pressure, aortic flow and coronary flow were measured and recorded. The control group is the group which the extracted heart was fixed on the isolated working heart model, recovered by reperfusion 60 minutes after infusion and preserved in the cardioplegic solution 20 minutes after the working heart perfusion and aortic cross clamp, The thesis groups were divided into group I, which ischemic hearts that were hypoxia induced were perfused by cardioplegic solution and preserved for 60 minutes; group II, the cardioplegic solution was infused 45 seconds (II-1), 1 minutes (II-2), 3 minutes (II-3), after the ischemia induction, 20 minutes after working heart perfusion and aortic cross clamp; and group III, hearts were executed on working heart perfusion for 20 minutes and aortic cross clamp was performed for 45 seconds (III-1), 1minute (III-2), 3 minutes (III-3), reperfused for 2 minutes to recover the heart, and then aortic cross clamping was repeated for reperfusion, all the groups were compared based on hemodynamic performance after reperfusion of the heart after preservation for 60 minutes. Result: The recovery time until spontaneous heart beat was longer in groups I, II-3, III-2 and III-3 to control group (p<0.01). Group III-1 (p<0.05) had better results in terms of recovery in number of heart rates compared to control group, and recovered better compared to II-1 (p<0.05). The recovery of aortic blood pressure favored group III-1 (p<0.05) and had better outcomes compared with II-1 (p<0.01). Group III-1 also showed best results in terms of cardiac output (p<0.05) and group III-2 was better compared to II-2 (p<0.05). Group I (p<0.01) and II-3 (p<0.05) showed more cardiac edema than control group. Conclusion: When the effects of other organs are dismissed, protecting the heart by infusion of cardioplegic solution after enforcing ischemia for a short period of time before the onset of abnormal heart beats for preconditioning has a better recovery effect in the cardioplegic group with preconditioning compared to the cardioplegic solution itself. we believe that further study is needed to find a more effective method of preconditioning.

A Study of Radon Reduction using Panel-type Activated Carbon (판재형 활성탄을 이용한 라돈 저감 연구)

  • Choi, Il-Hong;Kang, Sang-Sik;Jun, Jae-Hoon;Yang, Seung-Woo;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.297-302
    • /
    • 2017
  • Recently, building materials and air purification filters with eco-friendly charcoal are actively studying to reduce the concentration of radon gas in indoor air. In this study, radon reduction performance was assessed by designing and producing new panel-type activated carbon filter that can be handled more efficiently than conventional charcoal filters, which can reduce radon gas. For the fabrication of our panel-type activated carbon filter, first the pressed molding product after mixing activated carbon powder and polyurethane. Then, through diamond cutting, the activated carbon filter of 2 mm, 4 mm and 6 mm thickness were fabricated. To investigate the physical characteristics of the fabricated activated carbon filter, a surface area and flexural strength measurement was performed. In addition, to evaluate the reduction performance of radon gas in indoor, the radon concentration of before and after the filter passes from a constant amount of air flow using three acrylic chambers was measured, respectively. As a result, the surface area of the fabricated activated carbon was approximately $1,008m^2/g$ showing similar value to conventional products. Also, the flexural load was found to have three times higher value than the gypsum board with 435 N. Finally, the radon reduction efficiency from indoor gas improved as the thickness of the activated carbon increases, resulting in an excellent radon removal rate of more than 90 % in the 6 mm thick filter. From the experimental results, the panel-type activated carbon is considered to be available as an eco-friendly building material to reduce radon gas in an enclosed indoor environment.