• Title/Summary/Keyword: Matching thickness

Search Result 202, Processing Time 0.019 seconds

A Astudy on Bandwidth Enhancement of a Ultrasonic Transducer with a Taper (Taper형 초음파 진동자의 대역폭 개선에 관한 연구)

  • 정봉규
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.3
    • /
    • pp.312-322
    • /
    • 1999
  • A ultrasonic transduce with a single acoustic matching layer has been designed as an attempt to increase the bandwidth of underwater transducer. The wideband resonance condition was accomplished by attaching a single matching layer on the front face of a ceramic resonator composed of a piezoelectric bar, a taper part and a head part. A modified Mason's model was used for the performance analysis and the design of transducers, and the constructed transducers were tested experimentally and numerically by changing the impedance and thickness of the matching layer in the water tank.The obtained results are summarized as follows:1. Measured resonant and antiresonant frequencies of the piezoelectric transducer with no matching layer in air were 24.7 kHz and 25.6 kHz, respectively. 2. Two resonant frequencies of the piezoelectric transducer with a single matching layer were 21.7 kHx and 26.9 kHz, respectively, in air and 21.4 kHz and 22.7 kHz, respectively, with a water load.3. Two distinct resonance peaks in the transmitting voltage response(TVR) of the developed transducer were observed at 22.0 kHz and 25.8 kHz, respectively, with center frequency of 24.0 kHz. The values of TVR at these frequencies were 130.1 dB re $1 \muPa$/V at 22.0 kHz and 128.5 dB re $1 \muPa$/V at 25.8 kHz, respectively.Reasonable agreement between the experimental results and the numerical values was achieved.

  • PDF

Consideration of the Effect of Artifact during the Image Guided Radiation Therapy Using the Fiducial Marker (영상 유도 방사선치료 시 Fiducial Marker의 Artifact에 관한 연구)

  • Kim, Jong-Min;Kim, Dae-Sup;Back, Geum-Mun;Kang, Tae-Yeong;Hong, Dong-Ki;Yun, Hwa-Yong;Kwon, Kyeong-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.1-10
    • /
    • 2010
  • Purpose: The effect of artifact was analyzed, which occurs from fiducial marker during the liver Image Guided Radiation Therapy (IGRT) using the fiducial marker. Materials and Methods: The size of artifact of fixed fiducial marker and length of mobile fiducial marker locus were measured using the On-Board Imager system (OBI) and CT simulator, and 2D-2D matching and 3D-3D matching were carried out, respectively, and at this time, the coordinates transition value of couch was analyzed. Results: The measurement of fixed fiducial marker artifact size indicated CT 4.90, 8.10, 12.90, 19.70 mm and OBI 5.60, 10.60, 14.70, 29.40 mm based on the reference CT slice thickness of 1.25, 2.50, 5.00, and 10.00 mm. Meanwhile, the measurement of mobile fiducial marker locus length indicated CT 42.00, 43.10, 46.50 mm, and OBI 43.40, 46.00, 49.30 mm. The coordinates transition of 1.00, 2.00, and 8.00 mm occurred between 2D-2D matching and 3D-3D matching. Conclusion: It was confirmed that the therapy error increased during IGRT due to the influence of artifact when CT slice thickness increased. Thus, it may be desirable to acquire the image less than 2.50 mm in slice thickness when IGRT is implemented using the fiducial marker.

  • PDF

Design of Wideband Electromagnetic Wave Absorber Using Magnetic Materials (자성재료를 이용한 광대역 전자파 흡수체 설계 연구)

  • Kim, Dong Young;Yoon, Seok Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.6
    • /
    • pp.210-215
    • /
    • 2012
  • The absorption performance of a metal-backed single layered electromagnetic wave absorber is optimized at matching conditions of thickness and frequency indicating the maximum returns loss of incidence electromagnetic wave in the contour map. These matching conditions are obtained by applying the electromagnetic impedance to the transmission line theory, which depend on the complex permeability and complex permittivity of absorber material. The magnetic materials with high permeability can enhance the matching thickness condition to the wide frequency range based on the decrease of permeability with frequency and it can be used as a wideband electromagnetic wave absorber material. Therefore, the magnetic materials with higher saturation magnetization and lower permittivity than NiZn ferrite can be applied to the wideband electromagnetic wave absorber in order to satisfy the newly enforcing the electromagnetic compatibility regulation in the future.

A Study on the Development and Characteristics of PZT-EPOXY Ultrasonic Probe (PZT-EPOXY계 초음파프루브 제작과 특성에 관한 연구)

  • 이덕출;육재호;김진수;이용혁;이동렬
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.2
    • /
    • pp.192-198
    • /
    • 1992
  • The electrical properties of the ultrasonic probes and the piezoelectric composite materials with 1-3 connectivity by the extrusion method have been studied. The relative permittivity and piezoelectric coefficient increase linearly as PZT volume% increases and resonance frequency moves to low frequency as the sample thickness increases. The acoustic impedance matching with body and water is better than PZT ceramics' and the reception sensitivity is fine as the thickness thins down.

A 20 GHz low-loss dual - mode channel filter using mode matching method (모드정합법을 이용한 20GHz 저손실 이중모드 채널여파기)

  • 정근욱;이재현;유경완;강성춘
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.10
    • /
    • pp.53-59
    • /
    • 1997
  • In this paper, we present a 20 GHz low-loss dual-mode channel filter designed by using mode matching method. The performance of dual-mode channel filter mainly depends on iris characteristics. Therefore the exact design of iris is the key point to get good frequncy response of the filter. MOde matching technique is widely used ot design several kinds of waveguide filters because it is simple in theory and can easily calculate the scattering matrices at the discontinuities with simple structure like iris coupled filters. Additionally the effect for finite thickness of the iris in the dual-mode cavity iflter is analyzed by te full-wave method, providing the exact filter implementation without trial and error.

  • PDF

Broad-Band Underwater Acoustic Transducer for Doppler Velocity Log (도플러 속도계(DVL)를 위한 광대역 수중 음향 트랜스듀서)

  • Yun, Cheol-Ho;Lee, Yeoung-Pil;Ko, Nak Yong;Moon, Yong-Seon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.9
    • /
    • pp.755-759
    • /
    • 2013
  • A broad-band underwater acoustic transducer that uses thickness vibration mode, derived from a disk type piezoelectric ceramic, has been proposed and designed for DVL (Doppler Velocity Log). Three different types of acoustic transducer were evaluated with respect to the transmitting voltage response, receiving voltage sensitivity and bandwidth of the transducer. The effect of the acoustic impedance matching layer and backing layer is discussed. The results demonstrated that three matching layer with lossy backing layer is the best configuration for underwater transducer. The trial underwater acoustic transducer with three matching layer has a frequency bandwidth of 55%, maximum transmitting voltage response of 200 dB and a maximum receiving voltage sensitivity of -187.3 dB.

Design Method for the Optimized Acoustic Matching Layers of UT Probes (비파괴 검사용 초음파 탐촉자에서의 정합층 최적 설계법)

  • Park, Chi-seung;Kim, Seon-Jin
    • Korean Journal of Materials Research
    • /
    • v.13 no.10
    • /
    • pp.658-662
    • /
    • 2003
  • In this study, we have tried to find the optimized design variables of the matching layer which is important part of thickness mode ultrasonic transducer and finally reach the conclusion that the electrical property of piezo-element must be under consideration when the optimized acoustic impedance is estimated. Proper expression of the effective impedance of front load at free resonant frequency(: $Z_{f}$ $^{(0)}$ /) has been induced by introducing the principle of binomial multilayer transformer and gradient based numerical method is utilized to find the most acceptable value of $Z_{ f}$/$^{(0)}$ . Optimized point of acoustic impedance can be calculated directly from $Z_{f}$ $^{(0)}$ using some simple formula which we propose. We also verify our result by both numerical and experimental method and get a good enhancement especially it concern to the bandwidth of ultrasonic transducer.

Characteristic Analysis of the Asymmetric Coupled microstrip Lines with finite Metalization Thickness in the Multilayered Structure (다층구조에서 도체 두께를 고려한 비대칭 결합선로의 특성해석)

  • 윤남일;홍익표;박한규
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.3A
    • /
    • pp.424-429
    • /
    • 2000
  • In this paper, the characteristics of the asymmetric coupled microstrip(ACM) lines with finite metalization thickness are investigated using the quasi-static analysis in the multilayered structure. By mode-matching method as the quasi-static analysis. the characteristic impedances and effective dielectric constants in ACM lines are obtained as a function of metalization thickness. The numerical results show that the propagation characteristics of ACM lines in the single and multilayered structure will be changed by the variation of metalization thickness.

  • PDF

Study on Electrical Impedance Matching for Broadband Ultrasonic Transducer (광대역 초음파 변환기를 위한 전기 임피던스 정합 연구)

  • Kim, Geonwoo;Kim, Ki-Bok;Baek, Kwang Sae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.37 no.1
    • /
    • pp.37-43
    • /
    • 2017
  • Ultrasonic transducers with high resolution and resonant frequency are required to detect small defects (less than hundreds of ${\mu}m$) by ultrasonic testing. The resonance frequency and resolution of an ultrasonic transducer are closely related to the thickness of piezo-electric materials, backing materials, and the electric impedance matching technique. Among these factors, electrical impedance matching plays an important role because it can reduce the loss and reflection of ultrasonic energy differences in electrical impedance between an ultrasonic transducer and an ultrasonic defects detecting system. An LC matching circuit is the most frequently used electric matching method. It is necessary for the electrical impedance of an ultrasonic transducer to correspond to approximately $50{\Omega}$ to compensate the difference in electrical impedance between both connections. In this study, a 15 MHz immersion ultrasonic transducer was fabricated and an LC electrical impedance circuit was applied to that for having broad-band frequency characteristic.

Properties of Three Kinds of Ferrite/Rubber Composite Microwave Absorbers with Various Composition Ratio (조성비에 따른 3종 페라이트/고무 복합형 전파흡수체의 특성)

  • Ryu, Young-Jun;Jun, Hong-Bae;Kim, Cheol-Han;SaGong, Geon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1680-1682
    • /
    • 1999
  • In this study, three kinds of Mn-Zn ferrite/Ni-Zn ferrite/$Ni_2Y$ ferroxplana prepared by the coprecipitation method were compounded with the silicon rubber, and the ring-shaped specimens with various compositional ratio were made. The material constant of ferrite/rubber composite absorbers was obtained by the 2-port method. The material constants of the ferrite/rubber composite microwave absorber made of three kinds of ferrite with various compositional ratio were utilized in design the matching conditions (frequency and thickness) on the impedance matching map. We were able to predict the matching condition from the matching map. On all three kinds of ferrite/rubber composite microwave absorber with less than compositional ratio 60[wt.%] of ferroxplana, we have found that the reflection losses were over than 20[dB] at the S-Band $(2\sim4[GHz])$ and C-Band$(4\sim8[GHz])$.

  • PDF