• 제목/요약/키워드: Matching frequency

검색결과 940건 처리시간 0.028초

철계 연자성 합금 분말을 함유한 고무 복합재의 전파흡수특성 (Microwave Absorbing Properties of Rubber Composites Containing Soft Magnetic Fe-Alloy Particles)

  • 조한신;김성수
    • 한국분말재료학회지
    • /
    • 제20권2호
    • /
    • pp.125-128
    • /
    • 2013
  • Magnetic and dielectric properties of rubber composites are controlled by using two kinds of high-permeability metal particles with different electrical conductivity (Sendust, Permalloy), and their effect on microwave absorbance has been investigated, focusing on the quasi-microwave frequency band (0.8-2 GHz). Noise absorbing sheets are composite materials of magnetic flake particles of high aspect ratio dispersed in polymer matrix with various filler amount of 80-90 wt.%. The frequency dispersion and magnitude of complex permeability is almost the same for Sendust and Permalloy composite specimens. However, the complex permittivity of the Permalloy composite (${{\varepsilon}_r}^{\prime}{\simeq}250$, ${{\varepsilon}_r}^{{\prime}{\prime}}{\simeq}50$) is much greater than that of Sendust composite (${{\varepsilon}_r}^{\prime}{\simeq}70$, ${{\varepsilon}_r}^{{\prime}{\prime}}{\simeq}0$). Due to the large dielectric permittivity of Permalloy composite, the absorbing band is shifted to lower frequency region. However, the investigation of impedance matching reveals that the magnetic permeability is still small to satisfy the zero-reflected condition at the quasi-microwave frequency band, resulting in a small microwave absorbance lower than 10 dB.

임의유전체 기판을 이용한 주파수 혼합기의 소형화 (Size-Reduction of Frequency Mixers Using Artificial Dielectric Substrate)

  • 권경훈;임종식;정용채;안달
    • 전기학회논문지
    • /
    • 제62권5호
    • /
    • pp.657-662
    • /
    • 2013
  • A size-reduced high frequency mixer designed by adopting artificial dielectric substrate is described in this work. The artificial dielectric substrate is composed by stacking the lower substrate in which a lot of metalized via-holes exist, and upper substrate on which microstrip lines are realized. The effective dielectric constant increases due to the inserted lots of via-holes, and this may be applied to size-reduction of high frequency circuits. In this work, in order to present an application example of size-reduction for active high frequency circuits using the artificial dielectric substrate, a 8GHz single gate mixer is miniaturized and measured. It is described that the basic circuit elements for mixers such as hybrid, low pass filter, and matching networks can be replaced by the artificial dielectric substrate for size-reduction. The final mixer has 55% of size compared to the normal one. The measured average conversion gain is around 3dB which is almost similar result as the normal circuit.

DGS 구조를 이용한 자기발진혼합형 주파수 하향변환기 설계 (Design of A Self Oscillating and Mixing Frequency Down-Converter Using A DGS)

  • 정명섭;박준석;김형석;임재봉
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권11호
    • /
    • pp.536-543
    • /
    • 2003
  • In this paper, we describe a unique self oscillating and mixing (SOM) down-converter design using a modified defected ground structure (DGS). The proposed SOM converter is consisted of self-oscillator, which can produce negative resistance and select resonance frequency, RF matching circuit, and IF low pass filter. As the advantage of this SOM converter can mix LO and RF signals as well as inducing LO signal with only one active device. it is designed as a simple structure and the low cost. Also, there is easy advantage to be applied in RFIC/MMIC technology because it offers excellent phase noise performance in spite of using micro-strip structure. The LO signal for the proposed SOM converter is designed at 1㎓ and RF frequency was chosen to be 800MHz. The achieved conversion loss and phase noise performances of the implemented SOM converter are 15㏈ and -95dBc/Hz at 100KHz offset frequency respectively. The equivalent circuit parameters for DGS are extracted by using a three dimensional EM simulator and simple circuit analysis method.

케이블 내 근접 결함 추정을 위한 영상 처리 기반의 시간 주파수 영역 반사파 계측법 (Image Processing Based Time-Frequency Domain Reflectometry for Estimating the Fault Location Close to the Applied Signal Point)

  • 정종민;이춘구;윤태성;박진배
    • 전기학회논문지
    • /
    • 제63권12호
    • /
    • pp.1683-1689
    • /
    • 2014
  • In this paper, we propose an image processing based time-frequency domain reflectometry(TFDR) in order to estimate the fault location of a cable. The Wigner-Ville distribution is used for analysis in both the time domain and the frequency domain when the conventional TFDR estimates the fault location in a cable. However, the Winger-Ville distribution is a bi-linear function, and hence the cross-term is occurred. The conventional TFDR cannot estimate the accurate fault location due to the cross-term in case the fault location is close to the position where the reference signal is applied to the cable. The proposed method can reduce the cross-term effectively using binarization and morphological image processing, and can estimate the fault location more accurately using the template matching based cross correlation compared to the conventional TFDR. To prove the performance of the proposed method, the actual experiments are carried out in some cases.

CATV 및 MATV 시스템용 2분배기의 보상방법에 관한 연구 (A Study on Compensating Method of 2-way Power Splitter for CATV and/or MATV Systems)

  • 민경식;김동일;정세모
    • 한국통신학회논문지
    • /
    • 제18권4호
    • /
    • pp.499-508
    • /
    • 1993
  • 이 논문에서 CATV 및 MATV시스템용으로 널리 쓰이는 전력분배기의 설계법과 주파수특성해석을 다루고 있다. 즉, 윌킨슨형 파워디바이더를 집중정수회로화하여 CATV주파수대에 적합한 2분배기의 설계법을 이론적으로 고찰하고, 주파수특성을 해석하고 있다. 윌킨슨형 파워디바이더의 분배특성을 향상시키기 위해 보상회로를 부가한 최적설계법을 제시하여 특성평가를 하였으며, 그 결과 특성이 크게 향상됨을 이론적인 고찰과 실험을 통하여 증명하였다.

  • PDF

운동과 음악을 이용한 노래부르기가 노인의 생리적 변화, 인지기능 및 우울에 미치는 효과 (The Effects of Singing Program Combined with Physical Exercise of Physiologic Changes, Perception Function and Degree of Depression in the Elderly Women)

  • 정영주;민순
    • Journal of Korean Biological Nursing Science
    • /
    • 제3권2호
    • /
    • pp.35-50
    • /
    • 2001
  • This study was conducted for the evaluation of the effects of singing program combined with physical exercise on the physiologic changes, perception function and degree of depression. The subjects were the members of elderly women's glee club in D care center for the elderly, who have been singing for more than 6 months. 30 members were allocated to study group and 30 to control group. The singing program designed for both physical therapy and music therapy was consisted of initial physical exercise, singing art songs and classical song and the finishing physical exercise. This program was performed twice a week and about forth minutes was consumed for one session. We checked the heart rate, peripheral arterial oxygen saturation, perception function and degree of depression before and after the program. We used a pulse oxymeter to check the heart rate to oxygen saturation and a questionnaire for the evaluation of perception function and degree of depression. We need SPSS program for data analysis. The results of the investigated personnel complying with general characteristics were analyzed by frequency, two groups by t-test, data before and after the program by paired t-test, respectively. The results were as follows. 1) Heart rate after the program was significantly lower than that before program in test group(p<0.05). 2) Peripheral oxygen saturation after the program was significantly higher than that before the program(p<0.05). 3) Ability to match the right sign with a certain predetermined number was improved after the program. The frequency of wrong matching the sign with number before program was 30. But the frequency was decreased to 8 after the program. 4) Ability to calculate was improved after the program. The frequency of wrong calculation before the program was $1.10{\pm}1.94$. But the frequency after the program was decreased to $0.97{\pm}1.84$. 5) The degree of depression after the program($2.07{\pm}0.49$) was significantly lower than that before program(p<0.001). These results show that singing program combined with physical exercise improves the oxygen delivery to peripheral circulation, stability of heart function, the perception function(calculating and matching ability) and decreases the degree of depression. In conclusion, singing program combined with physical exercise can be used for the effective measure to improve the health of elderly and prevent dementia.

  • PDF

각속도계 적용을 위한 이중 질량 시스템의 주파수 응답에 관한 연구 (A study on frequency response of two-mass system for gyroscope applications)

  • 황영석;정형균;송은석;백창욱;김용권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.154-155
    • /
    • 2007
  • This paper describes frequency response of two-mass system for gyroscope applications. The two-mass system of the proposed device is adapted to the sensing part of the gyroscope in this research. Two-mass system has two resonant peaks and wide flat region between two resonant peaks. The resonant frequency of driving part is in this flat region. Therefore, frequency tuning is not necessary for mode matching. In the proposed device, resonant frequency is designed as 7183 Hz in driving part. Mass ratio of two masses in sensing part is 0.1 and device size is 6 mm $\times$ 6 mm. The device is fabricated by SiOG process. The fabricated spring width is increased from $4{\mu}m$ to $4.5{\sim}4.7{\mu}m$, and the measured resonant frequency is 8392 Hz in driving mode. We operated the sensing part using parallel plate of proof mass to verify the sensing part. It is confirmed the device has a wide fiat region in frequency response curve and the resonant frequency of the driving part is in the wide flat region of sensing mode.

  • PDF

Analysis of LSI Circuits Coupled with RCG Interconnects - Asymptotic Method

  • A.Ushida;Ha, A.ttori;H.Sakaguchi;Y.Yamagami;Y.Nishio
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -1
    • /
    • pp.70-73
    • /
    • 2002
  • High frequency digital LSI circuits are usually composed of many sub-circuits coupled with interconnects. They sometimes causes serious problems of the fault switching by time-delays, crosstalks, reflections of signals and so on. Therefore, it is very important to develop a user-friendly simulator for solving these problems. Although a moment matching method is widely used as the reduction technique of interconnects, it may happen to arise erroneous results for evaluating the poles far from the origin. In this paper, we show an asymptotic method in the complex frequency-domain, where we calculate the exact poles and residues giving large effect to the transient responses. Then, the interconnects are replaced by the asymptotic equivalent circuits using the poles and residues. Thus, we can develop a users-friendly simulator using the equivalent circuits.

  • PDF

PHEMT소자를 이용한 K-band MMIC 발진 설계 (K-band MMIC Oscillator Design Using the PHEMT)

  • 이지형;채연식;조희철;윤용순;이진구
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(2)
    • /
    • pp.88-91
    • /
    • 2000
  • An MMIC oscillator operating at the 24.55 GHz has been designed using 0.2 ${\mu}{\textrm}{m}$AlGaAs/InGaAs/GaAs Pseudomorphic HEMT technology. The active device used in the oscillator design has a 0.2 ${\mu}{\textrm}{m}$ gate length PHEMT with 4$\times$80 ${\mu}{\textrm}{m}$ gate width. We obtained 4.08 dB of S$_{21}$ gain and 317 mS/mm of transconductance, and extrapolated unit current gain cut-off frequency (f$_{T}$) and maximum oscillation frequency (fmax) were 62 GHz and 120 GHz, respectively. The circuit are based on a series feedback and negative resistance topology. Microstrip line open stub is used to terminating. The oscillator circuits has designed for delivering maximum power to load and conjugated matching. The simulated small signal negative resistance was 50 Ω. We obtained 1.002 of loop gain and 0.0005$^{\circ}$angle from the simulation by HP libra 6.1. The layout for oscillator is 1.2$\times$1.8 $\textrm{mm}^2$.>.

  • PDF

캐비티 동조에 의한 마이크로파 트란지스터 발진기 (Microwave Transistor Oscillator by Cavity Rexsonator)

  • 장익수;김병철
    • 대한전자공학회논문지
    • /
    • 제19권5호
    • /
    • pp.20-25
    • /
    • 1982
  • 무조건 안정한 트란지스터를 요구하는 주파수에서 케비티 공진궤환 루우프를 이용하여 마이크로파 발진기를 설계하는 방법을 제시한다. 필요한 주파수로 공진하는 높은 Q의 공진기를 궤환 루우프로 걸어줌으로써 그 주파수에서만 트란지스터치 출력 임피던스의 실수부가 부저항 특성을 갖게 할 수 있으므로, 주파수가 안정한 발진기를 구성한다. 본 연구에서는 실리콘 바이폴라 TR HXTR 2101과 Q가 크며, 실제 크기가 작은 리엔트런트 캐비티를 이용하여 발진 주파수 2.33GHz, 발진출력 10mW의 발진기를 실현하여 보았다.

  • PDF