• Title/Summary/Keyword: Masticatory force

Search Result 98, Processing Time 0.023 seconds

THE EFFECT OF SUPPORTING BONE DESIGNED BY STRESS BREAKER TYPE IMPLANT DENTURE IN EXPERIMENTAL ANIMAL (Implant denture 에서 Stress breaker type가 주위골조직에 미치는 영향)

  • Suh, Chang-Hwan
    • The Journal of the Korean dental association
    • /
    • v.15 no.8
    • /
    • pp.623-626
    • /
    • 1977
  • The author made two implant blades of gold alloy metal, and applied CEKA attachment to one blade. These two blades were implanted at the sockets resulting from removal of both 3rd premolar of experimental dog. Simple crown and tooth supporting denture was constructed on the implanted blades the author observed above mentioned procedures for 8 weeks. The obtained results were as follows; 1) There is no remarkable necrosis of supporting alveolar bone on both sides So, metal reaction was favourable. 2) Masticatory force which is loaded on each tooth was not effective on the alveolar bone.

  • PDF

Functional evaluation of orthopedic and orthodontic treatment in a patient with unilateral posterior crossbite and facial asymmetry

  • Kwak, Yoon-Young;Jang, Insan;Choi, Dong-Soon;Cha, Bong-Kuen
    • The korean journal of orthodontics
    • /
    • v.44 no.3
    • /
    • pp.143-153
    • /
    • 2014
  • An 8-years old boy with facial asymmetry and unilateral posterior crossbite on the left side received orthopedic and orthodontic treatment. During the first phase of treatment, the narrow maxillary arch was expanded using an acrylic plate. Then, the acrylic plate was used as a bite block with occlusal indentations from the construction bite that was obtained with the incisors in a coincident dental midline. After the position of the mandible was stabilized, the second phase of orthodontic treatment was initiated using fixed appliances for detailing of the occlusion. Skeletal symmetry, ideal occlusion, and coincident dental midlines were thus achieved. Functionally, occlusal force balance and masticatory muscle activity were improved, and the chewing patterns were normalized.

THE TRANSMANDIBULAR IMPLANT SYSTEM (The Transmandibular Implant System)

  • Moon, Hong-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.3
    • /
    • pp.435-444
    • /
    • 1997
  • Many of the problems which are faced to the edentulous patients are related to a minimal amount of available mandibular bone volume and height. Most of the patients with mild atrophy of the mandible are treated using endosseous implant prosthodontics. TMI(Trans-mandibular Implant) can be used in case of severe mandibular atrophy, poor bone quality, atrophy of the mandible with exposed of inferior alveolar nerve, osteoporosis and the fracture of the atrophic mandible. Also it can eliminate the need for bone grafting and vestibuloplasty. The TMI is a rigid box frame structure which controls and distribute the masticatory force over the severely resorbed mandible. The box frame structure consist of a superstructure, baseplate, 4 transosseous posts, and 5 cortical screws. This is a case report that also describes about the transmandibular implant reconstruction system.

  • PDF

Analysis of Stress Contour Plot of Implant Depending on Masticatory Force, Length, and Diameter (저작압, 직경, 길이 변화에 따른 임플란트 응력 분포 분석)

  • Nam, Young Jun;Yoon, Seung Hyun
    • Proceeding of EDISON Challenge
    • /
    • 2016.03a
    • /
    • pp.240-245
    • /
    • 2016
  • In this paper, stress contour plots depending on length, load, and diameter of the implant are presented. Depending on the condition and amount of cortical bone, process of implanting can be difficult and stress becomes important. Therefore deciding the right length and diameter of implant is critical. When analyzing stress in the implant, Von-mises yield criterion is often used; however, due to hardship of acquiring the actual material property of surrounding bones, simplified model of a implant was adapted in finite element analysis program of EDISON. The result acquired from EDISON program was then compared with results of different research papers.

  • PDF

Rehabilitation of Partial Edentulism with a Crown-type Implant-assisted Removable Partial Denture through Guided Implant Surgery: A Case Report with a 12-month Follow-up

  • Jun, Ji Hoon;Oh, Kyung Chul;Li, Jiayi;Moon, Hong Seok
    • Journal of Korean Dental Science
    • /
    • v.15 no.1
    • /
    • pp.75-83
    • /
    • 2022
  • Crown-type implant-assisted removable partial dentures (CIRPDs) can be a feasible treatment option for partially edentulous patients. Here we report a case with remaining unilateral mandibular teeth. Two implants were placed in the posterior portion of the mandible using a surgical guide, and a distal-extension removable partial denture with implant-supported surveyed crowns was fabricated. After 12 months, both the abutment teeth and implants were in good condition. The treatment outcomes were satisfactory in terms of masticatory function and esthetics. The advantages of CIRPDs and considerations for obtaining successful clinical outcomes with these dentures are also discussed.

Full-mouth rehabilitation of a patient with reduced occlusal vertical dimension due to severe wear: a clinical report (심한 마모로 인하여 교합 고경이 감소된 환자의 완전 구강 회복술)

  • Kim, Min-Jung;Kim, Hyeong-Seob;Woo, Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.39-46
    • /
    • 2013
  • The loss of posterior support may cause attrition of anterior teeth, and loss of occlusal vertical dimension (OVD). The collapse of the posterior support will eventually cause the pathologic change of the TMJ and masticatory muscles, unesthetic facial appearance and decreased masticatory function. Patients with destroyed dentition need extensive prosthetic treatments. Proper diagnosis and treatment planning are necessary for the stability of the neuromuscular system and the TMJ, and esthetic and functional definitive restorations. In this case, 63 year-old male presented with decreased masticatory force and esthetic problems due to pathologic destruction of teeth structure on entire dentition. Based on assessment of OVD including intraoral findings, radiographic examination and diagnostic cast, full-mouth rehabilitation with increase of OVD was planned using fixed partial denture and removable partial denture. Diagnostic wax-up was done after 4 mm increase of OVD determined by assessment of OVD. The OVD was maintained with the overlay type removable interim prostheses for 12 weeks to ascertain his comfort and adaptation to the new OVD. After the adaptation period, second interim prostheses with tooth preparation maintaining the established OVD was delivered. After 4 weeks, final prostheses were fabricated and delivered. After 7 month follow-up period, occlusal stability is maintained. Through this procedure, satisfactory outcomes were achieved both in functional and esthetic aspects.

Fracture Resistance of Incisal Tooth Fragment reattached with different Materials and Preparation (레진재료와 치아형성 방법에 따른 파절편 재부착치아의 파절저항성)

  • Kim, Jongsung;Kim, Gimin;Lee, Jaesik;Kim, Hyunjung;Nam, Soonhyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.1
    • /
    • pp.104-112
    • /
    • 2022
  • The purpose of this study is to analyze the fracture resistance of reattached tooth according to the resin materials and tooth preparation type under physiological conditions. Uncomplicated crown fracture in the oblique direction was reproduced on the extracted 64 anterior teeth. Depending on the composite resin material, reattachment was performed using a flowable resin and a packable resin. Depending on retentive forms, reattachment was performed using simple reattachment, 1.0 mm × 1.0 mm labial chamfer bevel, 1.0 mm × 1.0 mm lingual chamfer bevel and 1.0 mm × 1.0 mm circumferential bevel. A load was applied to the palatal surface of the tooth using a universal testing machine at an angle of 125 degree, which is the interincisal angle of normal children. Under the masticatory pressure condition, fracture resistance of lingual chamfer groups was 28.28 ± 7.41 MPa and 27.54 ± 4.45 MPa, which was significantly higher than those of simple reattachment groups, 17.21 ± 5.87 MPa and 20.10 ± 6.00 MPa, in both flowable and packable resin groups. When considering the lingual force similar to masticatory pressure, the fragment retention was significantly improved when the lingual chamfer was formed compared to the simple reattachment. Clinicians may consider the design of the lingual chamfer in order to improve fracture resistance to masticatory pressure during fragment reattachment.

Occlusal Analysis in the Policemen with Temporomandibular Disorders Using T-scan II System (경찰 종사자의 측두하악장애환자에서 T-scan II System을 이용한 교합분석)

  • Lim, Hyun-Dae;Jung, Seung-Ah;Lee, You-Mee
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.4
    • /
    • pp.365-373
    • /
    • 2006
  • This study suggested correction of excessive mouth opening or maximum occlusal contact to analyse occlusal contact time, occlusal contact number and force through evaluation of occlusal pattern in policemen with temporomandibular disorders. The community of policemen influence on temporomandibular disorder's development and progress due to other condition of mouth opening and maximal occlusal contact. Repeated training or changes of usual life style may cause imbalance of stomatognathic system including the masticatory muscle, then develop or aggravate pain of temporomandibular joints and associated structures. This study uses T-scan II system(Tekscan Co., USA) for evaluation on occlusal pattern may influence temporomandibular disorders, and then the subjects take a sensor at 20 mm opening for maximal occlusal contact force. The policemen with temporomandibualr disorders get more long time on maximum contact timing, more short on end contact timing, and more force on end contact force than general society's. So they get closure of mouth with more short time and more force, then transfer remaining load to temporomandibular joint. There are no statistically significances between affected side and occlusal pattern of occlusal contact time and force. There are Left -right dental arch imbalances seems on Rt. dental arch if affected side is right and Lt. dental arch if affected side is left. In above results, It's worth due consideration that policemen with temporomandibular disorders get more smooth mandibualr movement and less force on maximal occlusal contact position.

FINITE ELEMENT ANALYSIS OF STRESS PATTERNS ON PERIODONTIUM OF SPLINTED ABUTMENTSFOR DISTAL EXTENSION REMOVABLE PARTIAL DENTURE (후방연장 국소의치에서 지대치의 splinting에 따른 치주조직의 응력 변화에 관한 유한요소법적 연구)

  • Hwang, Jae-Woong;Chang, Ik-Tae;Kim, Kwang-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.2
    • /
    • pp.241-268
    • /
    • 1995
  • Splint therapy, the immobilization of teeth, has been done for patient's masticatory comforts and an adjunctive aid in periodontal therapy. Mandibular premolars are frequently splinted in many distal extension removable partial denture cases. But splinting is an extensive restoration that may not be conservative of tooth structure and may prove to be quite costly to the patient. The two dimensional finite element analysis method was used to determine the magnitude and mode of distribution of the stresses of the periodontal ligament and supporting alveolar bone when abutments with different periodontal supports were splinted and distal-extension removable partial denture was subjected to different loading schemes. The results were as follows : 1. When abutments were splinted, stresses moved from apico-distal to apico-mesial of terminal abutment on a vertical force and from disto-alveolar crest to apex on a distally directed force. But stresses were generally diminished on a mesially directed force. 2. As vertical bone loss was proceeding, most of stresses were transmitted to residual ridge and the rest of stresses were concentrated on apex of distal abutment. But these apical stresses were minimized when abutments were splinted. 3. As mesially inclined bone loss was proceeding, it seemed to be dangerous that many stresses were concentrated on the distal alveolar crest, especially in the distally directed load case. Abutments splinting decreased the alveolar crestal stresses but not enough. 4. For all vertical stresses were effectively decreased on splinting, stresses were concentrated as highly on apico-mesial area of distal abutment in distally directed load cases as the distal inclination of bone level was severe. 5. The directions and magnitudes of abutment movements were decreased with teeth splinting.

  • PDF

The Effect of a Shock-Absorbable Polymer(Chitosan) on the Initial Stability and Dynamic Behavior of Dental Implant (충격흡수용 고분자재료의 이용이 Implant 초기안정성과 동적거동에 미치는 영향)

  • Joo, W.;Choi, K.;Kwon, I.C.;Choi, J.B.;Moon, H.J.;Shin, J.W.;Lee, Y.C.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.337-342
    • /
    • 1997
  • Dental implant has been increasingly used to recover the masticatory unction of tooth. It has been well known that the success of dental implant is heavily dependent on initial stability and long-term osseointegration due to optimal stress distribution in the surrounding bones. The role of periodontal ligament, removed during operation, is to absorb impact force and to distribute them to alveolar bone. or this reason, the study for artificial periodontal ligament has become an important issue in this field. In this study, chitosan was coated on dental implant or the purpose of replacing the role of intact periodontal ligament. The results by experiment and FEM analysis showed : I) Initial stability of dental implant was significantly increased(35%) when the implant was coated with chitosan. II) The coated implant showed higher impact absorption, more even stress distribution and lower stress magnitude under impact force than uncoated implant. Accordingly, the micro-fracture of the surrounding bones due to impact force would be lessened by chitosan coating on dental implant.

  • PDF